Evaluation of Microporous Polysaccharide Hemospheres for Parenchymal Hemostasis During Laparoscopic Partial Nephrectomy in the Porcine Model (original) (raw)
JSLS: Journal of the Society of Laparoendoscopic Surgeons / Society of Laparoendoscopic Surgeons
We evaluated the efficacy of Microporous Polysaccharide Hemospheres (MPH) for parenchymal hemostasis during laparoscopic partial nephrectomy (LPN) in the porcine model. Six female farm pigs underwent a transperitoneal right lower-pole LPN during occlusion of the renal hilum. Renal parenchyma was excised using cold Endoshears. MPH was applied to the defect and the hilar clamp released. Animals were kept alive for one week. Before sacrifice, left LPN was similarly performed using MPH. Study variables included blood loss, number of MPH applications, hilar clamp time, hemostasis time, perioperative complications, and abnormalities noted at sacrifice. Hemostasis was achieved in all kidneys solely by using MPH. The average excised specimen represented 5.6% (range, 3.6 to 8.5) of renal weight. Mean hilar clamp and hemostatic times were 12.8 minutes (range, 6 to 18) and 2 minutes (range, 1 to 3), respectively. Hemostasis occurred after one MPH application in 8 kidneys (67%). In 3 kidneys, a...