Comparison of an Industry-Derived LCx Chlamydia pneumoniae PCR Research Kit to In-House Assays Performed in Five Laboratories (original) (raw)

Replicate PCR Testing and Probit Analysis for Detection and Quantitation of Chlamydia pneumoniae in Clinical Specimens

Journal of Clinical Microbiology, 2001

Nucleic acid amplification of clinical specimens with low target concentration has variable sensitivity. We examined whether testing multiple aliquots of extracted DNA increased the sensitivity and reproducibility of Chlamydia pneumoniae detection by PCR. Nested and non-nested C. pneumoniae PCR assays were compared using 10 replicates of 16 serial dilutions of C. pneumoniae ATCC VR-1310. The proportion positive versus the C. pneumoniae concentration was modeled by probit regression analysis. To validate the model, 10 replicates of 26 previously positive patient specimens of peripheral blood mononuclear cells (PBMC), sputum, or nasopharyngeal swabs (NPS) were tested. The proportion of replicates that were positive varied with the concentration of C. pneumoniae in the sample. At concentrations above 5 infection-forming units (IFU)/ml, both nested and non-nested PCR assay sensitivities were 90% or greater. The nested PCR was more sensitive (median detection, 0.35 versus 0.61 IFU/ml; relative median detection, 0.58; 95% confidence interval, 0.31 to 0.99; P ‫؍‬ 0.04). In clinical specimens, replicate PCR detected 15 of 26 (nested) versus 1 of 26 (non-nested, P < 0.001). For PBMC specimens, testing 1, 3, or 5 replicates detected 3, 5, or 9 of 10 positive specimens, respectively. Median C. pneumoniae concentrations were estimated at 0.07 IFU/ml for PBMC and at <0.03 IFU/ml for NPS specimens. We conclude that performing 5 or 10 replicates considerably increased the sensitivity and reproducibility of C. pneumoniae PCR and enabled quantitation for clinical specimens. Due to sampling variability, PCR tests done without replication may miss a large proportion of positive specimens, particularly for specimens with small amounts of target C. pneumoniae DNA present.

Comparison of a New Quantitative ompA-Based Real-Time PCR TaqMan Assay for Detection of Chlamydia pneumoniae DNA in Respiratory Specimens with Four Conventional PCR Assays

Journal of Clinical Microbiology, 2003

Chlamydia pneumoniae, an important respiratory pathogen, is difficult to culture, and detection rates by conventional PCRs vary considerably. A new quantitative ompA-based real-time PCR assay based on TaqMan technology for detection of C. pneumoniae in respiratory samples is described, and its performance in terms of sensitivity and reproducibility is compared with those of four published conventional PCRs (one single-step PCR targeting a cloned PstI fragment; two nested PCRs, one targeting the 16S rRNA gene followed by hybridization and the other targeting the ompA gene; and a touchdown enzyme time-release [TETR] PCR also targeting the 16S rRNA gene). Both ompA-based PCRs showed the best analytical sensitivity. All five assays could detect even lower target levels from spiked sputum, with the 16S rRNA assays performing better than the ompA-based nested PCR (10 ؊6 inclusion-forming units [IFU] were detected in four of four and two of four replicates by the 16S rRNA TETR PCR and the 16S rRNA nested PCR, respectively). In general, the ompAbased real-time protocol produced the most consistent positive results for all replicates tested down to 10 ؊6 IFU. Eight of 45 patient sputum specimens (18%) were C. pneumoniae DNA positive in at least one of four replicates tested by at least one assay. Without taking into consideration the analytical sensitivity or the reproducibility of the test results, the numbers of C. pneumoniae DNA-positive sputum specimens (n ‫؍‬ 8) were four, three, two, two, and one for the 16S rRNA TETR assay, the PstI-based single-step PCR, the ompA-based real-time PCR, the ompA-based nested touchdown PCR, and the 16S rRNA-based nested PCR, respectively. However, the overall rate of concordance of positive results was low. Only one cell culture-positive sputum specimen was positive by four of five assays (14 of 16 replicates; mean cycle threshold value, 25; 10 8 particles/ml of sputum). Thirty-seven specimens were C. pneumoniae negative by all five assays for all replicates tested, as were all negative controls (n ‫؍‬ 65 to 100 per testing panel). No PCR inhibitors were detected by real-time PCR or by the 16S rRNA-based nested assay. We confirm that the analytical sensitivity of an assay for the detection of C. pneumoniae does not necessarily predict its ability to detect its target in sputum. A quantitative, fast, and easy-to-handle diagnostic approach such as the ompA-based real-time TaqMan PCR described here might improve the detection of C. pneumoniae in respiratory samples.

Evaluation of real-time quantitative PCR for identification and quantification of Chlamydia pneumoniae by comparison with immunohistochemistry

Journal of Microbiological Methods, 2001

Chlamydia pneumoniae is a common cause of community-acquired pneumonia and it has been associated with atherosclerosis. C. pneumoniae has usually been diagnosed by serology using a microimmunofluorescence test, but more Ž . recently polymerase chain reaction PCR has been viewed as an advantageous alternative. We developed a quantitative real-time PCR for detection of C. pneumoniae. Primers were targeted for the pmp4 gene, and the PCR fragment was detected real-time with a fluorescence resonance energy transfer probe set using a LightCycler instrument. The PCR was used on DNA released from 50 mm sections of paraffin-embedded formalin-fixed lung tissue from experimentally infected mice. Thereby, the number of C. pneumoniae genomes was determined. To our knowledge this is the first time quantification of C. pneumoniae DNA has been attempted on paraffin-embedded formalin-fixed tissue. C. pneumoniae-Ž . specific immunohistochemistry IHC was done on 5 mm sections adjacent to the sections used in PCR, and the number of inclusions were counted in each section. Good correlation was found when comparing results from PCR and IHC, which is in contrast to many previous studies. q

Rapid detection of Chlamydia pneumoniae by PCR-enzyme immunoassay

Journal of clinical microbiology, 1998

Chlamydia pneumoniae is an important human respiratory pathogen. Laboratory diagnosis of infection with this organism is difficult. To facilitate the detection of C. pneumoniae by PCR, an enzyme immunoassay (EIA) for analysis of PCR products was developed. Biotin-labeled PCR products generated from the 16S rRNA gene of C. pneumoniae were hybridized to a digoxigenin-labeled probe and then immobilized to streptavidin-coated microtiter plates. Bound PCR product-probe hybrids were detected with antidigoxigenin peroxidase conjugate and a colorimetric substrate. This EIA was as sensitive as Southern blot hybridization for the detection of PCR products and 100 times more sensitive than visualization of PCR products on agarose gels. The diagnostic value of the PCR-EIA in comparison to cell culture was assessed in throat swab specimens from children with respiratory tract infections. C. pneumoniae was isolated from only 1 of 368 specimens tested. In contrast, 15 patient specimens were repeat...

Determination of PCR efficiency in chelex-100 purified clinical samples and comparison of real-time quantitative PCR and conventional PCR for detection of Chlamydia pneumoniae

BMC microbiology, 2002

Chlamydia pneumoniae infection has been detected by serological methods, but PCR is gaining more interest. A number of different PCR assays have been developed and some are used in combination with serology for diagnosis. Real-time PCR could be an attractive new PCR method; therefore it must be evaluated and compared to conventional PCR methods. We compared the performance of a newly developed real-time PCR with a conventional PCR method for detection of C. pneumoniae. The PCR methods were tested on reference samples containing C. pneumoniae DNA and on 136 nasopharyngeal samples from patients with chronic cough. We found the same detection limit for the two methods and clinical performance was equal for the real-time PCR and for the conventional PCR method, although only three samples tested positive. To investigate whether the low prevalence of C. pneumoniae among patients with chronic cough was caused by suboptimal PCR efficiency in the samples, PCR efficiency was determined based...

Diagnostic utility of PCR-enzyme immunoassay, culture, and serology for detection of Chlamydia pneumoniae in symptomatic and asymptomatic patients

Journal of Clinical Microbiology, 1994

To assess the utility of PCR-enzyme immunoassay (EIA) for diagnosis of acute infection with Chlamydia pneumoniae, we compared tissue culture, PCR-EIA, direct fluorescent-antibody (DFA) stain, and serology in studies with 56 patients with respiratory symptoms and 80 asymptomatic persons. Thirty-five patients were positive by either culture or PCR-EIA, and 101 were negative by both assays. Thirty specimens from symptomatic patients and one from an asymptomatic patient were culture positive; 23 of these were also PCR-EIA positive. Of the eight culture-positive, PCR-EIA-negative specimens, five were DFA negative and three were DFA positive. Four additional specimens were culture negative and PCR-EIA positive; of these, three were DFA positive and one was DFA negative. When we used culture-and/or DFA-positive results as a reference or "gold standard," the sensitivity and specificity of PCR were 76.5 and 99.0%, respectively. When we used PCRand/or DFA-positive results as the reference, the sensitivity of culture was 87.5%. On the basis of single acute serum specimens, only 8 of these 35 patients had diagnostic antibody titers. Of the asymptomatic patients, 75% had immunoglobulin G or immunoglobulin M antibody to C. pneumoniae; 15 (18.8%) of these had antibody levels considered to be diagnostic of acute infection. This multicenter study indicates that culture and/or PCR-EIA is more reliable for prompt diagnosis of C. pneumoniae infection than single-point serology alone.

Diagnostic Utility of PCR-Enzyme Imunoassay, Culture, and Serology for Detection of Chlamydia pneumoniae in Symptomatic and Asymptomatic Patients

Journal of Clinical Microbiology

To assess the utility of PCR-enzyme immunoassay (EIA) for diagnosis of acute infection with Chlamydia pneumoniae, we compared tissue culture, PCR-EIA, direct fluorescent-antibody (DFA) stain, and serology in studies with 56 patients with respiratory symptoms and 80 asymptomatic persons. Thirty-five patients were positive by either culture or PCR-EIA, and 101 were negative by both assays. Thirty specimens from symptomatic patients and one from an asymptomatic patient were culture positive; 23 of these were also PCR-EIA positive. Of the eight culture-positive, PCR-EIA-negative specimens, five were DFA negative and three were DFA positive. Four additional specimens were culture negative and PCR-EIA positive; of these, three were DFA positive and one was DFA negative. When we used culture-and/or DFA-positive results as a reference or "gold standard," the sensitivity and specificity of PCR were 76.5 and 99.0%, respectively. When we used PCRand/or DFA-positive results as the reference, the sensitivity of culture was 87.5%. On the basis of single acute serum specimens, only 8 of these 35 patients had diagnostic antibody titers. Of the asymptomatic patients, 75% had immunoglobulin G or immunoglobulin M antibody to C. pneumoniae; 15 (18.8%) of these had antibody levels considered to be diagnostic of acute infection. This multicenter study indicates that culture and/or PCR-EIA is more reliable for prompt diagnosis of C. pneumoniae infection than single-point serology alone.

Single-Run, Parallel Detection of DNA from Three Pneumonia-Producing Bacteria by Real-Time Polymerase Chain Reaction

The Journal of Molecular Diagnostics, 2005

A molecular assay for parallel detection of three bacteria, Chlamydia (C.) pneumoniae, Legionella (L.) spp., and Mycoplasma (M.) pneumoniae, in clinical specimens by a set of real-time polymerase chain reactions (PCRs) in a single run was evaluated. Bacterial DNAs were extracted by an automated DNA extraction protocol on the MagNA Pure LC System. Amplification and detection were done by real-time PCR on the LightCycler (LC) instrument. For amplification, specific oligonucleotides derived from the 16s rRNA genes of C. pneumoniae, L. spp., and M. pneumoniae were used. The three assays were complemented with an internal control (IC), a specially designed DNA fragment which contains the specific primer binding sites for the three PCRs. The IC was added to the samples, co-extracted, and co-amplified. Primers and hybridization probes were designed to suit one LC PCR program. LC PCRs were established, detection limits were determined, and clinical samples were tested. The detection limits were found between 5.0 and 0.5 IFU/CFU per PCR reaction for each of the bacteria. A total number of 100 clinical specimens were tested for validation of the molecular assay. Tested samples included 63 bronchoalveolar lavages (BALs) and 37 induced sputa specimens. The internal control was detected in all negative and lowpositive samples; no inhibition was found throughout the whole study. Additionally, samples underwent testing by culture for L. spp., and M. pneumoniae; for C. pneumoniae, the serological microimmunofluorescence (MIF) test was used. In conclusion, the developed set of LC PCR assays permits parallel detection of C. pneumoniae, L. spp., and M. pneumoniae in a single LC run. This molecular assay may lead to accurate and early diagnosis of pneumonia produced by these three types of bacteria. The assay proved to be suitable for the high-throughput routine diagnostic laboratory.

Simultaneous detection of Chlamydophila pneumoniae and Mycoplasma pneumoniae by use of molecular beacons in a duplex real-time PCR

Journal of clinical microbiology, 2008

A real-time PCR was designed for detection of Chlamydophila pneumoniae and Mycoplasma pneumoniae such that each pathogen could be detected in a single tube and differentiated using molecular beacons marked with different fluorochromes. This duplex PCR, targeting the P1 adhesion gene for M. pneumoniae and the ompA gene for C. pneumoniae, was compared with two conventional PCR assays targeting the 16S rRNA gene and the ompA gene. A total of 120 clinical throat and nasopharyngeal swab samples were tested. DNA extraction was performed using an alkali denaturation/neutralization method, and real-time amplification, detection, and data analysis were performed using a Rotor-Gene 2000 real-time rotary analyzer (Corbett Life Science, Sydney, Australia). Using conventional PCR as a reference in an analysis of 120 samples, 13 of 14 samples positive for C. pneumoniae were detected by the novel real-time PCR. In an analysis of M. pneumoniae, 22 samples were positive in the conventional PCR and the novel assay detected 24 positive samples. When using the conventional PCR as a reference, sensitivity and specificity were 93% and 100%, respectively, for C. pneumoniae and 100% and 98%, respectively, for M. pneumoniae. With an overall agreement of 98.8%, this suggests that performance of the new duplex real-time PCR is comparable to that of conventional PCR.

Two Quality Control Exercises Involving Nucleic Acid Amplification Methods for Detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae and Carried Out 2 Years Apart (in 2002 and 2004)

Journal of Clinical Microbiology, 2006

The quality performance of laboratories for the detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae by two quality control (QC) exercises with a 2-year interval was investigated. For the 2002 QC exercise, specimens were spiked with M. pneumoniae at concentrations of 5,000, 500, 50, and 0 color-changing units (CCU)/100 l. The limit of detectability was 50 CCU/100 l. Therefore, this concentration was omitted from the 2004 panel and was excluded from the analysis. In 2002, 2 out of 12 participants obtained 100% correct results, 2 out of 12 produced false-positive results, and 10 out of 12 had between 0 out of 9 and 8 out of 9 correct positive results. In 2004, correct results were obtained in 15 out of 18 tests, and no false-positive results were reported. In 2002, specimens were spiked with C. pneumoniae at concentrations of 490, 49, 4.9, and 0 inclusion-forming units/100 l (IFU/100 l). In the 2004 panel, samples spiked with a lower dilution of 0.49 IFU/100 l were added to the panel. For the C. pneumoniae QC, correct results were produced in 12 out of 16 and 13 out of 18 tests in 2002 and in 2004, respectively. Both multiplex PCR and nucleic acid sequence-based amplification (NASBA) formats scored a smaller number of samples positive than the monoplex reactions.