Using Dynamic Facade for Indoor Air Quality, Thermal Comfort and Energy Efficient Air Conditioning (original) (raw)
Related papers
Evaluation of Dynamic Insulation for Zone Ventilation and Air Conditioning in the Gulf Region
Buildings, new and old, account for 50% of global energy consumption and related emissions. This figure rises to more than 70% for the Gulf Region. Estimates of the cut in carbon emissions needed within our lifetime to avert catastrophic climate change range from 60% to 80% of current demand. Buildings thus present both a major impediment to reducing our reliance on the burning of dwindling reserves of fossil fuel and a real opportunity for achieving significant reduction in global carbon emissions. Dynamic Insulation (DI) is an energy-efficient method of supplying pre-tempered, filtered ventilation air to a building through an air-permeable, dynamically insulated envelope or facade. One of the important features of DI is that it effectively decouples ventilation rate from energy use. In theory, it should work well with all buildings, including homes, schools, offices and sports facilities where high occupancy is the norm. Our paper investigates the use of DI in a building facade fo...
Dynamic Insulation for Energy Conservation and Improved Indoor Air Quality in Hot Humid Climates
2006
Conventional energy sources continue to diminish, but the voracious demand for energy by a growing global population continues to increase. The accompanying CO 2 and other green house gas emissions have been identified as primary causes of global warming. As a consequence, the demand for cooling in buildings is expected to rise sharply within two decades. New energyefficient, environmentally friendly cooling systems are therefore urgently required to ensure a sustainable built environment and also to meet high indoor air quality standards. Dynamic insulation provides a means of supplying abundant quantities of fresh tempered air to a building that saves energy and at the same time improves the built environment.
The application of dynamic insulation in buildings
Renewable Energy, 1998
insulation, a form of 'Breathing Wall' construction which allows the movement of air and moisture through the external walls of a building, was seen as one possible method for reducing building envelope heat losses and achieving high indoor air quality.
Energy Efficiency of Ventilated Façades: Residential Buildings, Alicante, Spain
Structural Studies, Repairs and Maintenance of Heritage Architecture XV
Ventilated façades with external thermal insulation contribute to the construction, in certain climatologies, of a great energetic efficiency in the thermal envelope of the building. This façade allows to eliminate the thermal bridges, reduce the energy demand and improve the level of comfort. These pages describe the research carried out in an isolated residential block in the city centre of Alicante. The house has two façades with different orientation: a ventilated façade (north) and a conventional façade (south). The first one is solved with two sheets of brick, the air camera, the external continuous insulation, the ventilated chamber and the pieces of porcelain stoneware to the outside. The conventional one consists of two sheets with intermediate thermal insulation. The outer sheet is composed of facing brick and the inner sheet by hollow brick of minor thickness with plaster. This system was correct according to the norm NBE-CT-79, but it has been shown that it is insufficient to reach the levels of habitability and the comfort of the current society. The two façades, as well as their adjacent living spaces, have been monitored over a period of two years. Internal and external temperature and humidity, solar radiation, air velocity in the ventilated chamber and surface temperature of each of the material layers of the sections have been obtained. A thermographic study of the two chambers was carried out to determine the thermal bridges and the air infiltration. Through the use of energy simulation tools, comparative results of some parameters have been obtained in both constructive solutions, such as thermal transmissions, average radiant temperatures, operating temperatures or energy demands. By that, we can obtain the conclusions of thermal comfort levels and energy savings of ventilated façades.
Dynamic breathing buildings to combat global warming
Dynamic breathing building (DBB) is a new, innovative approach to construction that effectively reduces heat loss / gain through the fabric of a building, delivers pre-tempered ventilation air that has been filtered of Particulate Matter (PM) and reduces the operating and capital costs of the building. By drawing ventilation air in through a permeable Dynamic Insulation (DI) layer it is possible to capture the heat / coolth that flows out of the building and bring it back in to dramatically reduce the energy consumption associated with heating / cooling indoor spaces -i.e., the skin of the building effectively acts as a heat exchanger.
The effect of the ventilated facade on the thermal control and energy consumption of buildings
International Meeting on Advanced Technologies in Energy and Electrical Engineering, 2019
The facade of buildings is a heat exchange interface between the internal environment and the external environment. It represents the area where large thermal losses occur through convection, conduction and radiation. These modes of transfer have a considerable influence on the thermal operation of the building. This study presents an experimental study of the impact of natural convection of the air cavity of a ventilated facade on its thermal and energy efficiency during the cold period in the city of Biskra (hot and arid zones). The research was based on an experimental study by taking indoor and outdoor ambient and surface temperature measurements in cells tested on a reduced scale and then by numerical simulation using the dynamic thermal software TRNSYS. The results confirmed that the natural convection of the air cavity of a ventilated facade has a positive influence on the thermal operation and energy performance of the building during the winter period with the improvement of the ambient temperature (Ta above 20 °C) and the reduction of the energy consumption used for heating by up to 15%.
Opaque Ventilated Façades: Thermal and energy performance review
Renewable and Sustainable Energy Reviews, 2017
The use of Opaque Ventilated Façades (OVF) has considerably increased in recently years as an envelope solution in a variety of building types, climates, and design configurations. It is considered an appropriate solution not only for renovation of existing buildings but also for new buildings. The influence of ventilated façades in buildings is a constantly current issue in research always concluding the importance of the envelope in the reduction of energy needs in the whole building, and the importance of an accuracy model for the deep knowledge of the façade performance. Currently, the main interest in OVFs is their ability to reduce cooling thermal loads in Southern European locations. Although reference literature recognizes energy savings associated to the use of OVFs in comparison with traditional solutions, previous energy studies consider a limited number of locations and standard solutions. Trying to fill in an existing gap, this article includes information from different studies carried out in recent years which address the thermal and energy performance of OVFs. It also explains the implications of both external ambient conditions and design decision (external layer material, joints, air cavity width…) in terms of the energy and thermal performance of OVFs. This paper also provides some key strategies for customizing the façade design according to specific climate conditions.
Solar Energy, 2020
Nowadays, there is continuing worrying about energy efficiency and the reduction of GHG emissions in the building sector. It has been claimed that ventilated building envelopes help to reduce energy use in buildings and improve occupant comfort. This study proposes a comprehensive comparison of the thermal behaviour between an Opaque Ventilated Façade (OVF) and a conventional unventilated Façade (UF) considering two reference days for the winter and summer period. The analysis is developed investigating different façade orientations and two states of windiness, which are a state of calm wind and a state with wind velocity higher than zero (i.e. 5.0 m/s at 10 m of height) are taken into account. These analyses were developed utilizing fluid-dynamic calculation under dynamic conditions. Thus for the two façades were calculated: (I) the hourly surface temperatures of the most external, (II) the temperature profiles for all the facade's layers; (III) the airflow profiles inside the cavity and near the façade; (IV) the hourly thermal fluxes that cross the façade. Finally, the daily energy fluxes and the energy-saving, achievable through the adoption of the OVF, is calculated for the different façade exposures and the conditions of windiness. The outcomes of this study highlight that the OVF guarantees an energy-saving ranging from 20 to 55%, with the highest rate during the summer day for the façade facing East/West.