A Simple Analog Interface for Capacitive Sensor with Offset and Parasitic Capacitance (original) (raw)
Related papers
A Capacitive Humidity Sensor Suitable for CMOS Integration
IEEE Sensors Journal, 2000
This paper describes the design, fabrication, and performance of a thin film humidity sensor fabricated in standard CMOS process, hence it may be combined with an integrated circuit. The sensor is based on a capacitance between interdigitated electrodes in the top metal layer and water adsorption in the polyimide layer. The design is optimized by analytical and then finite element models which show that, within the constraint of the CMOS structure, the sensitivity can be no greater than one third of the sensitivity of the polyimide alone. Experimental sensors were fabricated in-house before an improved design was fabricated in a commercial foundry. The different behavior of these sensors, despite their similar designs, leads to an investigation into the effects of fabrication process on the sensor linearity. Characterizing the polyimide film by contact angle, AFM and FTIR revealed that the difference in linearity of the response between the two sensors resulted from different etching techniques employed to pattern the film.
Procedia Engineering, 2012
We here propose a new uncalibrated read-out circuit suitable for both capacitance and resistance measurements. This solution, employing only two Operational Amplifiers (OAs) as active blocks and some passive components, is based on a square-wave oscillator which, instead of a voltage integration typically performed by other solutions in the literature, operates a voltage differentiation. The circuit, performing an impedance-to-period (Z-T) conversion, results to be suitable as first analog front-end for both wide variation capacitive (e.g., for relative humidity) and resistive (e.g., for gas) sensors. Circuit sensitivity and dynamic range can be easily set through some passive components. A suitable prototype PCB has been fabricated so to perform electrical and humidity measurements, through the use of sample components and a commercial capacitive humidity sensor. Experimentals have shown a linear behaviour and a satisfactory accuracy in the evaluation of both floating capacitive (in the range [pF÷ F]) and grounded resistive (in the range [kΩ ÷MΩ]) variations.
DESIGN OF HIGH SENSITIVITY AND FAST RESPONSE MEMS CAPACITIVE HUMIDITY SENSOR
TJPRC, 2013
This paper presents a model which predicts the temporal response of capacitive humidity sensors made of parallel electrodes and a polymer sensitive coating. This model is used for the simulation of the response of the sensor subjected to specific conditions. The model includes electrostatic and molecular diffusion calculation. As an application example, the model is used to simulate the response of several humidity sensor structures exposed to the conditions of a medical application related to breath analysis. The model may also be helpful to predict the effects of fabrication process uncertainties. Because the model used to describe water diffusion in Polyimide is based on Henry’s law and Fick’s law, it could be extended to the optimization of capacitive sensors for other vapours
An accurate interface for capacitive sensors
IEEE Transactions on Instrumentation and Measurement, 2002
A new smart interface based on a first-order chargebalanced SC-oscillator is presented for capacitive sensors, which are shunted by a parasitic conductance. In the novel interface, the effect of shunting conductance is reduced by using the charge/discharge method. The effect of the stray capacitances is eliminated by using the two-port measurement. Moreover, all multiplicative and additive errors of the interface are also eliminated by using the auto-calibration technique and the chopping technique.
Analysis of a Direct Interface Circuit for Capacitive Sensors
IEEE Transactions on Instrumentation and Measurement, 2000
We present the theoretical analysis and performance results of a direct microcontroller unit (MCU) interface circuit for capacitive sensors based on the charge-transfer method, when stray capacitances are considered. The interface circuit can implement two alternative two-point calibration techniques that reduce the effects of stray capacitance, temperature, and MCU parameters that depend on the power supply voltage. The best measurement deviation achieved from 0 • C to 50 • C and for power supply voltage from 4.0 to 5 V is below 0.01 full-scale range (FSR) for the two subranges from 10 to 100 pF and from 100 pF to 1 nF and 0.08 FSR for the subrange from 2 to 10 pF.
Capacitive Sensor Interfaced with Arduino
The present paper gives the detailed analysis of the relationship between Voltage and Capacitance. This conversion from capacitance to voltage is required for the interfacing of electronic microcontrollers. Detection of various dielectrics can be done by using an accurate low capacitance measurement system that can be used to measure small values of capacitances. This capacitance measurement system uses quad two-input NAND Schmitt trigger circuit for the measurement and this system is integrated with Arduino for data acquisition purpose. The Arduino interacts with software developed in the PC end through USB architecture and an attractive Graphical User Interface (GUI) based system is developed in the PC end to provide the user with real time, online display of capacitance under measurement.
Comparison of Two Low-Power Electronic Interfaces for Capacitive Mems Sensors
The paper discusses the importance and the issues of interfacing capacitive sensors. Two architectures applicable for interfacing capacitive sensors are presented. The first solution was designed to interface a capacitive humidity sensor designed and built for a humiditydependent monolithic capacitor developed at Budapest University of Technology and Economics. The second case presents the possible read-out solutions for a SOI-MEMS accelerometer. Both of the architectures were built and tested in a discrete implementation to qualify the methods before the integrated realization. The paper presents a detailed comparison of the two methods.
SOME ASPECTS CONCERNING THE RELATIVE HUMIDITY MEASUREMENT WITH CAPACITIVE SENSOR
In this paper it is presented a circuit for the relative humidity measurement. A humidity capacitive sensor of type HUMICOR 5000 (produced of CORECI Company) is used. This sensor transforms the humidity variations into capacitance variations. The measurement principle consists in the inclusion of sensor in a UA 555 oscillator, of which output frequency is dependent on the relative humidity. A frequency-voltage converter with Phase Locked Loop (PLL) is used to obtain a relative humidity dependent voltage. The PLL used for the frequency-voltage conversion is a simple solution, which presents the advantage of a very low noise sensibility that can affect the input signal. The simplicity of the proposed measurement circuit and the obtained results, a series of experimental results obtained by measurement and SPICE simulation presented in the paper, allows its use in different applications such as environment monitoring, pharmaceutical industry, tile and brick drying, etc.
Parametrically Amplified Low-Power MEMS Capacitive Humidity Sensor
We present the design, fabrication, and response of a polymer-based Laterally Amplified Chemo-Mechanical (LACM) humidity sensor based on mechanical leveraging and parametric amplification. The device consists of a sense cantilever asymmetrically patterned with a polymer and flanked by two stationary electrodes on the sides. When exposed to a humidity change, the polymer swells after absorbing the analyte and causes the central cantilever to bend laterally towards one side, causing a change in the measured capacitance. The device features an intrinsic gain due to parametric amplification resulting in an enhanced signal-to-noise ratio (SNR). 11-fold magnification in sensor response was observed via voltage biasing of the side electrodes without the use of conventional electronic amplifiers. The sensor showed a repeatable and recoverable capacitance change of 11% when exposed to a change in relative humidity from 25-85%. The dynamic characterization of the device also revealed a respon...