High-frequency percussive ventilation: a new strategy for separation from extracorporeal membrane oxygenation (original) (raw)
A & A case reports, 2015
Abstract
We report the case of a 48-year-old woman who developed severe septic shock and lung injury after community-acquired pneumonia. She was supported on arteriovenous extracorporeal membrane oxygenation (ECMO) for 19 days. To facilitate decannulation and separation from ECMO, we began trials of high-frequency percussive ventilation (HFPV) using the volumetric diffusive respiration ventilator VDR-4 (Percussionaire Corp, Sandpoint, Idaho) for 4 consecutive days (1 before and 3 after). Decannulation was achieved successfully, and the patient was transferred to the floor 3 months later. During the 4 days of HFPV, the chest radiograph improved, as did gas exchange and clearance of pulmonary secretions. HFPV may be a promising strategy for improving lung recruitment and airway clearance during separation from ECMO in the critically ill patient.
Fabio Baratto hasn't uploaded this paper.
Let Fabio know you want this paper to be uploaded.