Clinical introduction of Monte Carlo treatment planning: A different prescription dose for non-small cell lung cancer according to tumor location and size (original) (raw)

Dosimetric Verification of Stereotactic Body Radiotherapy Treatment Plans For Early Stage Non-Small Cell Lung Cancer Using Monte Carlo Simulation

Sri Herwiningsih

View PDFchevron_right

Optimizing dose prescription in stereotactic body radiotherapy for lung tumours using Monte Carlo dose calculation

Joachim Widder, Johannes Langendijk

Radiotherapy and Oncology, 2010

View PDFchevron_right

The influence of beam model differences in the comparison of dose calculation algorithms for lung cancer treatment planning

Daniel McShan

Physics in Medicine and Biology, 2005

View PDFchevron_right

Commissioning a fast Monte Carlo dose calculation algorithm for lung cancer treatment planning

Matt Mulligan

Journal of Applied Clinical Medical Physics, 2008

View PDFchevron_right

Stereotactic, Single-Dose Irradiation of Lung Tumors: A Comparison of Absolute Dose and Dose Distribution Between Pencil Beam and Monte Carlo Algorithms Based on Actual Patient CT Scans

Frederik Wenz

International Journal of Radiation Oncology*Biology*Physics, 2010

View PDFchevron_right

Clinical impact of dose overestimation by effective path length calculation in stereotactic ablative radiation therapy of lung tumors

Neville Eclov

Practical Radiation …, 2012

View PDFchevron_right

Evaluation of Uncertainty-Based Stopping Criteria for Monte Carlo Calculations of Intensity-Modulated Radiotherapy and Arc Therapy Patient Dose Distributions

Barbara Vanderstraeten, Nick Reynaert

International Journal of Radiation Oncology*Biology*Physics, 2007

View PDFchevron_right

The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage

Lena Specht

Radiotherapy and Oncology, 2009

View PDFchevron_right

Radiation Dose Prescription for Non–Small-Cell Lung Cancer According to Normal Tissue Dose Constraints: An In Silico Clinical Trial

Angela Van Baardwijk, Geert Bosmans

International Journal of Radiation Oncology*Biology*Physics, 2008

View PDFchevron_right

Advanced proton beam dosimetry part II: Monte Carlo vs. pencil beam- based planning for lung cancer

Stephen Bowen

View PDFchevron_right

Influence of dose calculation algorithms on isotoxic dose-escalation of non-small cell lung cancer radiotherapy

Alan E Nahum, Chinnamani Eswar

Radiotherapy and Oncology, 2010

View PDFchevron_right

Dose distributions in SBRT of lung tumors: Comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions

Maria Duch

Acta Oncologica, 2006

View PDFchevron_right

Comparison between the ideal reference dose level and the actual reference dose level from clinical 3D radiotherapy treatment plans

Giorgio Arcangeli

Radiotherapy and Oncology, 2009

View PDFchevron_right

Evaluation of heterogeneity dose distributions for Stereotactic Radiotherapy (SRT): comparison of commercially available Monte Carlo dose calculation with other algorithms

Akihiro Haga

Radiation Oncology, 2012

View PDFchevron_right

Dosimetric differences between local failure and local controlled non-small cell lung cancer patients treated with stereotactic body radiotherapy: A matched-pair study

Chandana Reddy

Journal of medical imaging and radiation oncology, 2018

View PDFchevron_right

Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy

Bahar Dirican

Journal of Applied Clinical Medical Physics

View PDFchevron_right

An overview of Monte Carlo treatment planning for radiotherapy

Emiliano Spezi

Radiation Protection Dosimetry, 2008

View PDFchevron_right

Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches

Lei Dong

2006

View PDFchevron_right

Influence of Calculation Algorithm on Dose Distribution in Irradiation of Non-Small Cell Lung Cancer (NSCLC)

Otto Sauer

Strahlentherapie und Onkologie, 2004

View PDFchevron_right

A Dose Distribution Approach Using Monte Carlo Simulation In Dosimetric Accuracy Calculation For Treating The Lung Tumor

Tapan Kumar Godder

2018

View PDFchevron_right

Correlation of dose computed using different algorithms with local control following stereotactic ablative radiotherapy (SABR)-based treatment of non-small-cell lung cancer

Suneetha Devpura

Radiotherapy and Oncology, 2013

View PDFchevron_right

Dosimetric Comparisons of Lung SBRT with Multiple Metastases by Two Advanced Planning Systems

Jack Yang

View PDFchevron_right

Monte Carlo characterization of target doses in stereotactic body radiation therapy (SBRT)

Bill Salter

Acta Oncologica, 2006

View PDFchevron_right

Dosimetric verification of PENSSART, a new Monte Carlo dose calculation system based on PENELOPE and dedicated to patient-specific treatment quality control in radiotherapy

C. Le Loirec

View PDFchevron_right

Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

Giovanni Storto, Alba Fiorentino

Medical Dosimetry, 2014

View PDFchevron_right

Application of Monte Carlo Simulation in Treatment Planning for Radiation Oncology

Soo min

Applications of Monte Carlo Methods in Biology, Medicine and Other Fields of Science, 2011

View PDFchevron_right

Independent calculation‐based verification of volumetric‐modulated arc therapy–stereotactic body radiotherapy plans for lung cancer

Takamasa Mitsuyoshi

Journal of Applied Clinical Medical Physics, 2020

View PDFchevron_right

Dose escalation in the radiotherapy of non-small-cell lung cancer with aperture-based intensity modulation and photon beam energy optimization for non-preselected patients

Luc Beaulieu

Radiotherapy and Oncology, 2009

View PDFchevron_right

Clinical implementation, validation and use of the DPM Monte Carlo code for radiotherapy treatment planning

Alex Roșu

Ann …, 2003

View PDFchevron_right

A comparison of 18-MV and 6-MV treatment plans using 3D dose calculation with and without heterogeneity correction

Kenneth Hogstrom

Medical Dosimetry, 1999

View PDFchevron_right

Monte Carlo based dose estimation in intraoperative radiotherapy

Jacobo Cal_González

… Record (NSS/MIC), …, 2010

View PDFchevron_right