OUTDOOR TESTING OF PHOTOVOLTAIC MODULES DURING SUMMER IN TAXILA, PAKISTAN (original) (raw)
Related papers
This paper presents the comparative performance evaluation of three commercially available photovoltaic modules (monocrys-talline, polycrystalline, and single junction amorphous silicon) in Taxila, Pakistan. The experimentation was carried out at outdoor conditions for winter months. Power output, module efficiency, and performance ratio were calculated for each module and the effect of module temperature and solar irradiance on these parameters was investigated. Module parameters showed strong dependence on the solar irradiance and module temperature. Monocrystalline and polycrystalline modules showed better performance in high irradiance condition whereas it decreased suddenly with decrease in irradiance. Amorphous solar module also showed good performance in low irradiance due to its better light absorbing characteristics and thus showed higher average performance ratio. Monocrystalline photovoltaic module showed higher monthly average module efficiency and was found to be more efficient at this site. Module efficiency and performance ratio showed a decreasing trend with increase of irradiance and photovoltaic module back surface temperature.
Indonesian Journal of Electrical Engineering and Computer Science, 2022
This work is based on a comparative study of the impact of meteorological conditions as well as the assessment of the production performance of two identical photovoltaic stations installed in two Moroccan cities, the stations are based on three different technologies. The measures of one year of operation from January 2017 to December 2017 were evaluated. The annual average performance ratios were found to be 82.42%, 79.99% and 78.74% in Beni Mellal, and 85.29%, 84.61% and 70.41% in El Jadida for the polycrystalline (pc-Si), monocrystalline (mc-Si), and amorphous (a-Si) respectively. The photovoltaic efficiency was calculated at 12.24%, 11.89%, and 11.71% in Beni Mellal; and 12.59%, 12.49%, and 10.42% in El Jadida by the same order. Statistical analysis was carried out to establish the correlation with photovoltaic (PV) production showed that after irradiation, the temperature is the most influencing meteorological factor for PV production, revealing a degradation in the performanc...
Performance Evaluation of Various Photovoltaic Module Technologies at Nawabshah Pakistan
International Journal of Renewable Energy Development
The purpose of this study was to evaluate the influence of module temperature on the efficiency of polycrystalline (p-Si), monocrystalline (m-Si), amorphous (a-Si) and thin film photovoltaic modules at outdoor environment of Nawabshah city Pakistan. The experimental setup was made and installed over the top roof of departmental building. Weather conditions, such as global solar radiation, ambient temperature, wind speed and relative humidity, power output and temperature of all selected four types of module technologies were measured at the site by logging data. Then, the logged data was normalized because of different rated power of photovoltaic modules for comparison purpose. Results revealed that less temperature impact was noted from thin film module and thus it gave more normalized power with 45.6% among other examined modules. On the basis of overall efficiency, p-Si, m-Si, a-Si and thin film modules gave 92.4%, 93.7%, 94.4% and 95.4% yearly average normalized efficiencies res...
Sustainability
The objective of this study is to investigate the effect of temperature and wind speed on the performance of five photovoltaic (PV) module technologies for different climatic zones of Pakistan. The PV module technologies selected were mono-crystalline silicon (MC); poly-crystalline silicon (PC); heterogeneous intrinsic thin-film (TFH); copper–indium–allium–selenide (TFC); and thin-film amorphous silicon (TFA). The module temperature and actual efficiency were calculated using measured data for one year. The actual efficiency of MC, PC, TFH, TFC, and TFA decreases by 3.4, 3.1, 2.2, 3.7, and 2.7%, respectively, considering the effect of temperature only. The actual efficiency of MC, PC, TFH, TFC, and TFA increases by 9.7, 9.0, 6.5, 9.5, and 7.0% considering the effect of both temperature and wind speed. The TFH module is the most efficient (20.76%) and TFC is the least efficient (16.79%) among the five materials. Under the effect of temperature, the actual efficiency of TFH is the lea...
2017
In this paper we present an experimental and modeling study of three photovoltaic modules. The influence of weather conditions on the performances of the 3 modules is assessed. Some characterization tools have been developed to interpret functioning of photovoltaic cells while determining the limiting parameters. Our study is focusing on the assessment of the performance of three photovoltaic modules available in the market: Monocrystalline, polycrystalline and amorphous silicon. We have adopted a single diode model to determine the series resistance, the shunt resistance, diode ideality factor and the photo current. This is compared to our experimental data taken in conditions of the region of Agadir, a city in southwestern Morocco.
American Journal of Applied Sciences, 2009
The temperature dependence coefficients of amorphous silicon and crystalline photovoltaic (PV) modules using Malaysian field data have been obtained using linear regression technique. This is achieved by studying three test stand-alone PV-battery systems using 62 Wp a-Si, 225 Wp multicrystalline and 225 Wp mono-crystalline PV modules. These systems were designed to provide electricity for rural domestic loads at 200 W, 500 W and 530 W respectively. The systems were installed in the field with data monitored using data loggers. Upon analysis, the study found that the normalized power output per operating array temperature for the amorphous silicon modules, multicrystalline modules and mono-crystalline modules were: +0.037 per°C, +0.0225 per °C and +0.0263 per °C respectively. In addition, at a solar irradiance value of 500 Wm −2 , the current, voltage, power and efficiency dependence coefficients on operating array temperatures obtained from linear regression were: +37.0 mA per °C,-31.8 mV per °C,-0.1036 W per °C and-0.0214% per °C, for the a-Si modules, +22.5 mA per °C,-39.4 mV per °C,-0.2525 W per °C,-0.072 % per °C for the multi-crystalline modules and +26.3 mA per °C,-32.6 mV per °C,-0.1742 W per °C,-0.0523 % per °C for the mono-crystalline modules. These findings have a direct impact on all systems design and sizing in similar climate regions. It is thus recommended that the design and sizing of PV systems in the hot and humid climate regions of the globe give due address to these findings.
Outdoor Performance Characterization of the Poly-crystalline Silicon Solar Module
Journal of Science Foundation, 2018
The outdoor performance characterization of the poly-crystalline silicon solar PV module was studied. Daily solar illumination data were measured using two pyranometers and analyzed together with the module output power. The present paper reports the temperature dependencies of full-spectrum photovoltaic parameters for poly-crystalline PV module. The measurements were performed under outdoor environment conditions. The most interesting feature that was observed for these devices is that above a cell temperature of 20 0 C the positive temperature coefficient observed for the short-circuit current exceeds in magnitude the negative temperature coefficient that was found for the open-circuit voltage. This means that, unlike the situation for conventional PV module, these cells actually exhibit decrease in efficiency with increasing temperature.
International Journal of Physical Research, 2018
There is need to always obtain the realistic outdoor performance variables of Photovoltaic (PV) module in a location for efficient PV power system sizing and design. Outdoor performance evaluation was carried out on three types of commercially available silicon PV modules rated 10 W each, using CR1000 software-based Data Acquisition System (DAS). The PV modules under test and meteorological sensors were installed on a metal support structure at the same test plane.The data monitoring was from 08.00 to 18.00 hours each day continuously for a period of one year, from December 2014 to November 2015. Maximum values of module efficiencies of 5.86% and 10.91% for the monocrystalline and polycrystalline modules were respectively recorded at irradiance of 375 W/m2, while the amorphous efficiency peaked at 3.61 % with irradiance of 536.5 W/m2. At 1000 W/m2 the efficiencies reduced to 3.30 %, 6.20 % and 2.25 % as against manufacturer's specifications of 46 %, 48 % and 33 % for the monocrystalline, polycrystalline and amorphous modules respectively. The maximum power output achieved for the modules at irradiance of 1000 W/m2 were 0.711 W, 1.323 W and 0.652 W for the monocrystalline, polycrystalline and amorphous PV modules, respectively. Accordingly, Module Performance Ratios for the PV modules investigated were 0.07, 0.13 and 0.07, respectively. The rate of variation of module response variables with irradiance and temperature was determined using a linear statistical model given as Y= a + bHg+ c Tmod. The approach performed creditably when compared with measured data.
Studies realized on the performance of photovoltaic modules have shown that analysis of the effect of meteorological parameters is crucial in prediction and evaluation of performances; and production of solar systems. This paper highlights the performing analysis of a monocrystalline silicon photovoltaic module. The aim of this work is to study the effect of irradiance and temperature on module performance in a real environment. The variation of the exergy efficiency as a function of the module temperature on a day is presented. The electrical exergy rate and the thermal exergy losses rate of the module were examined. The findings of this study show that the exergetic efficiency depends on the variation of the irradiance and temperature during the day. Results give an exergetic efficiency of the module varying from 14.87 to 17.93% per day for monocrystalline 30 Wp PV module. The results also show a variation of exergetic efficiency for the same irradiance and decrease in efficiency with increasing module operating temperature. This decrease is 17.5% for an increase of 10 K (irradiance = 900 /² Wm). The thermal exergy losses rate increases with the difference between the module's operating temperature and the ambient temperature. It reaches its maximum (3.36 W) for a temperature difference equal to 28.9 K.
Renewable Energy, 2017
Highlights The study is focused on the performance assessment of five different kind of photovoltaic (PV) module technologies including thin film technology and a meteorological station, installed at the city of Saida, in Algeria. The PV modules are three thin film modules: copper indium selenide (CIS), monocrystalline heterojunction with intrinsic thin layer (HIT) and tandem structure of amorphous silicon and microcrystalline silicon (a-Si_μc-Si) with two crystalline silicon modules: multi-crystalline and mono-crystalline back contact. The assessment is based on the performance parameters, which are calculated according to IEC standard 61724.