Imaging of molecular probe activity with Born-normalized fluorescence optical projection tomography (original) (raw)

Mapping molecular agents distributions in whole mice hearts using born-normalized optical projection tomography

PloS one, 2012

To date there is a lack of tools to map the spatio-temporal dynamics of diverse cells in experimental heart models. Conventional histology is labor intensive with limited coverage, whereas many imaging techniques do not have sufficiently high enough spatial resolution to map cell distributions. We have designed and built a high resolution, dual channel Born-normalized near-infrared fluorescence optical projection tomography system to quantitatively and spatially resolve molecular agents distribution within whole murine heart. We validated the use of the system in a mouse model of monocytes/macrophages recruitment during myocardial infarction. While acquired, data were processed and reconstructed in real time. Tomographic analysis and visualization of the key inflammatory components were obtained via a mathematical formalism based on left ventricular modeling. We observed extensive monocyte recruitment within and around the infarcted areas and discovered that monocytes were also exte...

OptiJ: Open-source optical projection tomography of large organ samples

The three-dimensional imaging of mesoscopic samples with Optical Projection Tomography (OPT) has become a powerful tool for biomedical phenotyping studies. OPT uses visible light to visualize the 3D morphology of large transparent samples. To enable a wider application of OPT, we present OptiJ, a low-cost, fully open-source OPT system capable of imaging large transparent specimens up to 13 mm tall and 8 mm deep with 50 μm resolution. OptiJ is based on off-the-shelf, easy-to-assemble optical components and an ImageJ plugin library for OPT data reconstruction. The software includes novel correction routines for uneven illumination and sample jitter in addition to CPU/GPU accelerated reconstruction for large datasets. We demonstrate the use of OptiJ to image and reconstruct cleared lung lobes from adult mice. We provide a detailed set of instructions to set up and use the OptiJ framework. Our hardware and software design are modular and easy to implement, allowing for further open micr...

In vivo fluorescence lifetime optical projection tomography

Biomedical optics express, 2011

We demonstrate the application of fluorescence lifetime optical projection tomography (FLIM-OPT) to in vivo imaging of lysC:GFP transgenic zebrafish embryos (Danio rerio). This method has been applied to unambiguously distinguish between the fluorescent protein (GFP) signal in myeloid cells from background autofluorescence based on the fluorescence lifetime. The combination of FLIM, an inherently ratiometric method, in conjunction with OPT results in a quantitative 3-D tomographic technique that could be used as a robust method for in vivo biological and pharmaceutical research, for example as a readout of Förster resonance energy transfer based interactions.

Increased depth of cellular imaging in the intact lung using far-red and near-infrared fluorescent probes

International journal of biomedical imaging, 2006

Scattering of shorter-wavelength visible light limits the fluorescence imaging depth of thick specimens such as whole organs. In this study, we report the use of four newly synthesized near-infrared and far-red fluorescence probes (excitation/emission, in nm: 644/670; 683/707; 786/814; 824/834) to image tumor cells in the subpleural vasculature of the intact rat lungs. Transpelural imaging of tumor cells labeled with long-wavelength probes and expressing green fluorescent protein (GFP; excitation/emission 488/507 nm) was done in the intact rat lung after perfusate administration or intravenous injection. Our results show that the average optimum imaging depth for the long-wavelength probes is higher (27.8 ± 0.7 μm) than for GFP (20 ± 0.5 μm; p = 0.008; n = 50), corresponding to a 40% increase in the volume of tissue accessible for high-resolution imaging. The maximum depth of cell visualization was significantly improved with the novel dyes (36.4 ± 1 μm from the pleural surface) ...