Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector (original) (raw)

Radiation dose optimization in coronary angiography and percutaneous coronary intervention (PCI). II. Clinical evaluation

European Radiology

In a previous part of this study, the fluoroscopy dose rate was reduced in a cardiac catheterization laboratory. The objectives of the present study were to evaluate the effects in a clinical population undergoing percutaneous coronary intervention (PCI) of the dose-reducing measures detailed previously. Kerma area-product (KAP) values were first recorded for 154 patients undergoing PCI. Then, the fluoroscopy KAP rate was reduced from 44 to 16 mGy cm(2)/s by increasing filtration and reducing the image intensifier dose request. After this optimization, KAP was recorded for another 138 PCI procedures. After adjustment for differing proportions of combined procedures (coronary angiography+PCI), the total KAP was reduced to 67% of the original value with a 95% confidence interval from 57 to 78%, statistically significant. The mean total KAP values were 93.6 Gy cm(2) before and 69.1 Gy cm(2) after optimization. The KAP for digital acquisition did not change significantly. It is possible...

Radiation dose measurements in coronary CT angiography

World journal of cardiology, 2013

Coronary computed tomography (CT) angiography is associated with high radiation dose and this has raised serious concerns in the literature. Awareness of various parameters for dose estimates and measurements of coronary CT angiography plays an important role in increasing our understanding of the radiation exposure to patients, thus, contributing to the implementation of dose-saving strategies. This article provides an overview of the radiation dose quantity and its measurement during coronary CT angiography procedures.

Radiation dose optimization in coronary angiography and percutaneous coronary intervention (PCI). I. Experimental studies

European Radiology

The objectives of this study were to evaluate the influence on image quality and dose to the patient and operator of various equipment settings for percutaneous coronary intervention (PCI), and to optimize the set-up. With an Alderson phantom, different settings, such as projection, protective screens, filtration, image intensifier size and collimation, were evaluated. Kerma-area product (KAP) was recorded as a measure of patient dose and scattered radiation was measured with an ionization chamber. Effective dose for a standardized PCI procedure was measured with thermoluminescent dosimeters inside the phantom. Image quality was evaluated with a contrast-detail phantom. Based on these findings, the equipment set-up was optimized to a low fluoroscopy dose rate with a sufficient image quality. Several operating parameters affected dose, particularly scattered radiation. The optimization reduced the fluoroscopy KAP rate from 44 to 16 mGy cm(2)/s using 15 cm of acrylic. The effective do...