Titanium surface functionalization with coatings of chitosan and polyphenol-rich plant extracts (original) (raw)
Related papers
Chitosan coating as an antibacterial surface for biomedical applications
PloS one, 2017
A current public health issue is preventing post-surgical complications by designing antibacterial implants. To achieve this goal, in this study we evaluated the antibacterial activity of an animal-free chitosan grafted onto a titanium alloy. Animal-free chitosan binding on the substrate was performed by covalent link via a two-step process using TriEthoxySilylPropyl Succinic Anhydride (TESPSA) as the coupling agent. All grafting steps were studied and validated by means of X-ray Photoelectron Spectroscopy (XPS), Time-of-Flight secondary ion mass spectrometry (ToF-SIMS) analyses and Dynamic-mode Secondary Ion Mass Spectrometry (DSIMS). The antibacterial activity against Escherichia coli and Staphylococcus aureus strains of the developed coating was assessed using the number of colony forming units (CFU). XPS showed a significant increase in the C and N atomic percentages assigned to the presence of chitosan. A thick layer of polymer deposit was detected by ToF-SIMS and the results o...
Biomaterials, 2004
Implanted biomaterials are coated immediately with host plasma constituents, including extracellular matrix (ECM); this reaction may be undesirable in some cases. Poly(l-lysine)-grafted-poly(ethylene glycol) (PLL-g-PEG) has been shown to spontaneously adsorb from aqueous solution onto metal oxide surfaces, effectively reducing the degree of non-specific adsorption of blood and ECM proteins, and decreasing the adhesion of fibroblastic and osteoblastic cells to the coated surfaces. Cell adhesion through specific peptide-integrin receptors could be restored on surfaces coated with PLL-g-PEG functionalized with peptides of the RGD (Arg-Asp-Gly) type. To date, no study has examined the effect of surface modifications by PLL-g-PEG-based polymers on bacterial adhesion. The ability of Staphylococcus aureus to adhere to the ECM and plasma proteins deposited on biomaterials is a significant factor in the pathogenesis of medical-device-related infections. This study describes methods for visualizing and quantifying the adhesion of S. aureus to smooth and rough (chemically etched) titanium surfaces without and with monomolecular coatings of PLL-g-PEG, PLL-g-PEG/PEG-RGD and PLL-g-PEG/PEG-RDG: The different surfaces were exposed to S. aureus cultures for 1-24 h and bacteria surface density was evaluated using scanning electron microscopy and fluorescence microscopy. Coating titanium surfaces with any of the three types of copolymers significantly decreased the adhesion of S. aureus to the surfaces by 89-93% for PLL-g-PEG, and 69% for PLL-g-PEG/PEG-RGD. Therefore, surfaces coated with PLL-g-PEG/PEG-RGD have the ability to attach cells such as fibroblasts and osteoblasts while showing reduced S. aureus adhesion, resulting in a selective biointeraction pattern that may be useful for applications in the area of osteosynthesis, orthopaedic and dental implantology. r
PLoS ONE, 2012
Complications in dentistry and orthopaedic surgery are mainly induced by peri-implant bacterial infections and current implant devices do not prevent such infections. The coating of antibacterial molecules such as chitosan on its surface would give the implant bioactive properties. The major challenge of this type of coating is the attachment of chitosan to a metal substrate. In this study, we propose to investigate the functionalization of titanium with chitosan via a silanation. Firstly, the surface chemistry and mechanical properties of such coating were evaluated. We also verified if the coated chitosan retained its biocompatibility with the peri-implant cells, as well as its antibacterial properties. FTIR and Tof-SIMS analyses confirmed the presence of chitosan on the titanium surface. This coating showed great scratch resistance and was strongly adhesive to the substrate. These mechanical properties were consistent with an implantology application. The Chitosancoated surfaces showed strong inhibition of Actinomyces naeslundii growth; they nonetheless showed a non significant inhibition against Porphyromonas gingivalis after 32 hours in liquid media. The chitosan-coating also demonstrated good biocompatibility to NIH3T3 fibroblasts. Thus this method of covalent coating provides a biocompatible material with improved bioactive properties. These results proved that covalent coating of chitosan has significant potential in biomedical device implantation.
Chitosan patterning on titanium implants
Titanium and its alloys are widely used in medical implants because of their excellent properties. However, bacterial infection is a frequent cause of titanium-based implant failure and also compromises its osseointegration. In this study, we report a new simple method of providing titanium surfaces with antibacterial properties by alternating antibacterial chitosan domains with titanium domains in the micrometric scale. Surface microgrooves were etched on pure titanium disks at intervals of 60 μm using a modified 3D printer and were then coated with chitosan antibacterial polysaccharide. The dimensions of the patterned microgrooves made it possible to fix the chitosan domains to the titanium substrate without the need for covalent bonding. These domains were stable after 5 days of immersion in water and reduced the surface contact angle. Preliminary cell adhesion assays demonstrated that MC3T3-E1 pre-osteoblasts preferentially adhered to the titanium regions, while C2C12 myoblasts were uniformly distributed over the whole surface.
Biologically Modified Titanium Substrates for Improved Surface Bioactivity
2018
Post-surgery infections and not effective integration represent a serious issue in the Titanium (Ti) based implants function for a long term stability. To reduce such issue various surface functionalization method including surface coating has been explored. Here we successfully coated Ti substrates with Graphene Oxide (GO), Chitosan (Cs), and nanocomposite of GO and Cs (GO/Cs) via spin coated method to evaluate the osteogenic properties of each coatings. Uncoated Ti substrates were used as control. Scanning electron microscopy was used to investigate the coating morphology. Surface roughness measurements were achieved from atomic force microscopy. To measure surface wettability, contact angels method was performed. Ti substrates coated with Cs (TiCs) and Cs/GO (TiCs/GO) showed the highest surface wettability compared to Ti substrates coated with GO (TiGO) and the control. The highest surface roughness was also observed in TiCs/GO. To test cellular attachment and proliferation the s...
Materials
Pure titanium and titanium alloys are widely used in dentistry and orthopedics. However, despite their outstanding mechanical and biological properties, implant failure mainly due to post-operative infection still remains a significant concern. The possibility to develop inherent antibacterial medical devices was here investigated by covalently inserting bioactive ammonium salts onto the surface of titanium metal substrates. Titanium discs have been functionalized with quaternary ammonium salts (QASs) and with oleic acid (OA), affording the Ti-AEMAC Ti-GTMAC, Ti-AUTEAB, and Ti-OA samples, which were characterized by ATR-FTIR and SEM-EDX analyses and investigated for the roughness and hydrophilic behavior. The chemical modifications were shown to deeply affect the surface properties of the metal substrates and, as a consequence, their bio-interaction. The bacterial adhesion tests against the Gram-negative Escherichia Coli and Gram-positive Staphylococcus aureus, at 1.5 and 24 h of ba...
Surface and Coatings Technology, 2019
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Role of chitosan in titanium coatings. trends and new generations of coatings
Frontiers in Bioengineering and Biotechnology
Survival studies of dental implants currently reach high figures. However, considering that the recipients are middle-aged individuals with associated pathologies, research is focused on achieving bioactive surfaces that ensure osseointegration. Chitosan is a biocompatible, degradable polysaccharide with antimicrobial and anti-inflammatory properties, capable of inducing increased growth and fixation of osteoblasts around chitosan-coated titanium. Certain chemical modifications to its structure have been shown to enhance its antibacterial activity and osteoinductive properties and it is generally believed that chitosan-coated dental implants may have enhanced osseointegration capabilities and are likely to become a commercial option in the future. Our review provided an overview of the current concepts and theories of osseointegration and current titanium dental implant surfaces and coatings, with a special focus on the in vivo investigation of chitosan-coated implants and a current...
Bacteria and cell cytocompatibility studies on coated medical grade titanium surfaces
Journal of Biomedical Materials Research Part A, 2006
Acute and chronic osteomyelitis caused by staphylococci can be difficult to treat by conventional means and often has marked consequences for the patient. Current methods of treatment involve the use of systemic antibiotics, the local implantation of nondegradable drug carriers, and surgical debridement. A possible solution that could prevent initial bacterial adhesion could be to modify the implant surface with an antimicrobial coating while maintaining biocompatibility to host cells. This study describes the cytocompatibility evaluation of different coatings (poly(d,l-lactide) (PDLLA), politerefate (PTF), calcium phosphate/anodic plasma-chemical treatment (CaP/APC), polyurethane (PU), and polyvinylpyrollidone (PVP) on titanium surfaces with and without chlorhexidine diacetate (CHA) to Staphylococcus aureus, Staphylococcus epidermidis, and hTERT human fibroblasts. Surface characterization of the coatings showed no significant variation in the roughness or hydrophobicity of the coated surfaces, except the CaP/APC surface that was porous yet the smoothest, and PVP, PVP ϩ CHA, and CaP/ APC ϩ CHA that were more hydrophilic in nature than the others. On the surfaces without CHA, both staphylococcal strains and spread fibroblasts were observed, but on the CHA impregnated surfaces few bacteria and no intact fibroblasts were seen. Flow cytometry found fewer bacteria in the media and on the surfaces containing CHA in comparison to the surfaces without CHA. The release kinetics varied from slow (over 200 h) to burst release: PDLLA Ͼ PTF Ͼ PU Ͼ CaP/APC ϭ PVP. This study showed that PDLLA and PTF have the best potential as coatings on implants for drug delivery, as they were cytocompatible to hTERT fibroblasts, eluted CHA effectively, and passed mechanical testing. The actual release kinetics of PDLLA and PTF are important, as the amount of CHA present should remain above the minimal inhibitory concentration value for a limited time before disappearing completely.
Clinical treatment of orthopaedic tissue injuries often involves the use of titanium and titanium alloys with considerable research focusing on the surface modification of these materials. Chitosan, the partly deacetylated form of chitin, is one of the materials under investigation as surface coating for orthopaedic implants in order to improve osteointegration and cellular attachment. In this study, we determined the effects of the degree of deacetylation (DD) of chitosan membranes on attachment, proliferation and osteogenic differentiation of MC3T3-E1 mouse preosteoblasts. Chitosan membranes were coated with fibronectin to promote biocompatibility and cellular attachment. Membranes were characterized in terms of wettability and surface topography using water contact angle measurements and atomic force micros-copy. The results in this study indicate that the surface roughness and fibronectin adsorption increase with increased DD. A higher DD also facilitates attachment and proliferation of cells, but no induction of spontaneous osteogenic differentiation was observed. Lower DD chitosan membranes were successfully prepared to sustain attachment and were modified by crosslinking with glutaraldehyde to promote longterm studies. The chitosan membranes used in this study are suitable as a potential coating for titanium implants. V C 2012