Effective platform for the generation of aerosol droplets and application in evaluating the effectiveness of a MEMS-based nanoparticle trapping device (original) (raw)
Related papers
A System to Create Stable Nanoparticle Aerosols from Nanopowders
Journal of visualized experiments : JoVE, 2016
Nanoparticle aerosols released from nanopowders in workplaces are associated with human exposure and health risks. We developed a novel system, requiring minimal amounts of test materials (min. 200 mg), for studying powder aerosolization behavior and aerosol properties. The aerosolization procedure follows the concept of the fluidized-bed process, but occurs in the modified volume of a V-shaped aerosol generator. The airborne particle number concentration is adjustable by controlling the air flow rate. The system supplied stable aerosol generation rates and particle size distributions over long periods (0.5-2 hr and possibly longer), which are important, for example, to study aerosol behavior, but also for toxicological studies. Strict adherence to the operating procedures during the aerosolization experiments ensures the generation of reproducible test results. The critical steps in the standard protocol are the preparation of the material and setup, and the aerosolization operatio...
Japanese Journal of …, 2010
The state of electrostatically deposited aerosol particles from a suspension that contains TiO 2 particles on the surface of a solid substrate using electrospray was demonstrated. The particles were initially electrosterically stable in 7.5 wt % aqueous solution with a mean particle size of 50 nm. During deposition, the particles were pumped with different flow rates between 0.6 and 1.2 mL/h through a stainless steel capillary tube of 0.1 mm inner diameter. The particles were emitted at the tip of the capillary tube as an electrified liquid cone before forming into a highly charged droplet. For comparison, two types of substrate surfaces with and without chemical treatment were prepared. Atomic force microscopy (AFM) scanning and contact angle measurements showed that surface treatment increased the substrate roughness and created a hydrophilic surface. Raman analysis also showed the existence of an oxide layer and a P-O network on the treated substrate. Field emission scanning electron microscopy FE-SEM image analysis showed that more TiO 2 particles were deposited on the treated substrate than on the untreated substrate. #
Development of a Compact Electrostatic Nanoparticle Sampler for Offline Aerosol Characterization
MAPAN, 2013
A compact electrostatic nanoparticle sampler has been developed to support the offline analysis of nanoparticles via electron microscopy. The basic operational principle of the sampler is to electrically charge particles by mixing nanoparticles and unipolar ions produced by DC corona discharge, and electrostatically collecting charged particles. A parametric study was first performed to identify the optimal operating condition of the sampler: a total flow rate (i.e., the sum of the particle and ion carrier flow rates) of 1.0 lpm, an aerosol/ion carrier flow rate ratio of 1.0, and a collection voltage of 4.5 kV. Under the above condition, the sampler achieved a collection efficiency of more than 90 % for particles ranging from 50 to 500 nm. The effect of particle material on the sampler's performance was also studied. The prototype had lower collection efficiencies for oleic acid particles than for sodium chloride particles in the size range from 50 to 150 nm, while achieving a comparable efficiency in the size range large than 150 nm. Effects of particle diameter, particle material, and total flow rate on the sampler's collection efficiency are explained by the particle charging data, i.e., charging efficiencies and average charges per particle.
From electrostatic precipitation to nanoparticle generation
Journal of Aerosol Science, 2012
This work demonstrated that an electrostatic precipitator (ESP), originally designed for dust collection, could become a nanoparticle generator under specific operating conditions. A lab-scale wire-plate positive ESP was built for measuring aerosol penetration and generation rate. The carrier air was filtered by activated charcoal, silica gel and HEPA filters to remove potential contaminants. The data, obtained in both power-on and power-off modes, were utilized to calculate penetration and generation rate of aerosol. The results showed that air temperature appeared to have a strong effect on ESP nanoparticle generation. At temperature above 37 1C and flow rate below 9 L/min, the nanoparticle penetration of ESP exceeded 100%, indicating that the ESP was generating aerosol particles. Sputtering on the corona discharger appeared to be the key mechanism of aerosol generation. The ozone concentration increased with increasing corona current. The ESP reached a maximum number concentration at the electric field strength of 4.8 kV/cm when the air flow and temperature were fixed at 6 L/min and 40 1C, respectively. The particle size ranged from 5 to 40 nm, with a mode around 12 nm. Elementary components of the discharge wire were detected on the filter samples collected downstream the ESP and ground plates, indicating that nanoparticles were generated from the discharge wire.
2019
The reduction of particles in ultrapure water (UPW) systems is driven primarily by the semiconductor industry. Particles that can produce defects in chip manufacturing and potentially reduce yield, are now identified to be 10 nm and smaller. Isolating and collecting particles in this size range using the classical filtration technique of sieving is limited, time consuming and in many cases, ineffective. Additionally, locating 10 nm particles on a 25 mm filter with a total surface area of more than 500 mm (500,000,000 nm) is highly labor intensive. Focused Aerosol Deposition (FAD) is a technique that combines extraction of nanoparticles from UPW via aerosolization with focused droplet deposition on an SEMready stub. This provides an extremely localized collection of particles as small as 5 nm. Improvements in aerosol focusing, evaporation management and direct deposition on scanning electron microscope ready media has resulted in a focal point as small as 0.04 mm with repeatable posi...
Journal of Aerosol Science, 2014
The effect of chemical treatment of a metallic substrate on the deposition behavior of charged aerosol particles derived from spraying droplets was investigated. A single substrate with areas having different hydrophilic levels was prepared as target surface. The treated (i.e., higher hydrophilic level) area, measured using a surface potential meter, showed a higher negative potential. A numerical simulation predicted that positively charged aerosol particles tended to approach and were subsequently immobilized on the high hydrophilic area. The area with higher hydrophilicity could collect particles with higher number concentration (density) than the other areas. The relationships were demonstrated in (i) the electrostatic surface potential, (ii) the hydrophilicity of surface, and (iii) the enhancement of adhesive force between the deposited particles and the surface.
Nanotechnology, 2010
Carbon nanotubes are difficult to aerosolize in a controlled manner. We present a method for generating aerosols not only of carbon nanotubes, but also of many reference and proprietary materials including quantum dots, diesel particulate matter, urban dust, and their mixtures, using electrospraying. This method can be used as a teaching tool, or as the starting point for advanced research, or to deliver nanomaterials in animal exposure studies. This electrospray system generates 180 µg of nanotubes per m 3 of carrier gas, and thus aerosolizes an occupationally relevant mass concentration of nanotubes. The efficiency achievable for single-walled carbon nanotubes is 9.4%. This system is simple and quick to construct using ordinary lab techniques and affordable materials. Since it is easy to replace soiled parts with clean ones, experiments on different types of nanomaterial can be performed back to back without contamination from previous experiments. In this paper, the design, fabrication, operation and characterization of our versatile electrospray method are presented. Also, the morphological changes that carbon nanotubes undergo as they make the transition from dry powders to aerosol particles are presented.
Nanoparticle aerosol science and technology: an overview
China Particuology, 2005
As a new scientific discipline, nanoparticle aerosol science and technology (NAST) deals with the formation, properties and behavior of nanoparticles in gases. Driven by its practical applications in many different fields, NAST has been undergoing rapid development. A conceptual framework of the discipline, with its own basic principles, experimental methods and computational techniques, is now taking shape. This paper presents an overview of the current status and research needs of the new discipline. The presentation begins with a discourse on the relationship among various particle systems, which occur frequently in nature and industry. The properties and behavior of nanoparticle aerosols are then discussed, with emphasis on the key roles played by particle size and morphology. Similar to fluid dynamics, NAST is an enabling discipline in the sense that it has provided the concepts and methodology needed for the development of many other fields. Applications of nanoparticle aerosol science and technology are highlighted in three important areas: (1) aerosol processes for synthesis of nanoparticles, (2) atmospheric nanoparticles and global climate, and (3) dosimetry of inhaled nanoparticles. These fields have features in common insofar as nanoparticle aerosols follow the same basic laws of physics and chemistry.
Development and Validation of a Novel Particle Source for Nano-sized Test Aerosols
Aerosol and Air Quality Research, 2018
In the EU, there is an increasing need for regulatory agencies to establish health-based threshold limits for airborne particles. A prerequisite for such projects is the validation and comparison of existing and newly developed particle analyzers. Corresponding proficiency tests have often been conducted with the help of inter-laboratory tests using test aerosols. Although test aerosols in the micro-and the nanoscale range were produced with different generator systems at the technical center of the Institute for the Research on Hazardous Substances (IGF) in Dortmund, a stable and reproducible method of producing a low number concentration for nano-sized particles was not achieved. Inspired by a method of monodisperse droplet generation, we coupled a flame generator with a droplet generator and examined the concentration and the diameter of the formed particles as a consequence of the precursor concentration and the droplet frequency. In addition, the reproducibility of the method was tested daily, and the nanoparticles were collected and characterized microscopically. Finally, the measurements of the particle size distribution were mathematically examined. The resulting fits enable the prediction of the median particle diameter as a function of the precursor concentration and the frequency of the droplets. Overall, the performed experiments confirm that this system meets all the requirements with regard to a low number concentration and long-term stability and reproducibility and should therefore be suitable for further inter-laboratory round robin tests.
A New Thermophoretic Precipitator for Collection of Nanometer-Sized Aerosol Particles
Aerosol Science and Technology, 2005
A new thermophoretic precipitator (TP) has been designed and used for the collection of nanosized aerosol particles. NaCl and Fe particles, with mean diameters of 55 nm and 3.6 nm, respectively, were used to determine the thermophoretic deposition efficiency as well as the uniformity of the deposition. When the average temperature gradients applied were 2200 K/cm and 2400 K/cm, a