The Changed of Behaviour of MR Fluid in MR Damper after a Long-Term Operation (original) (raw)
Abstract
Magnetorheological (MR) fluid devices are now applied in various applications. Although a lot of studies have been discussed in long-term implementation of MR devices, only few studies have concerned on MR fluid application in valve operation mode, such as at MR valve. The experiments were conducted on a dynamic test machine in a custom MR damper with meandering MR valve. The experiment test was applied at continuous-load in long term-operation with parameters of 20 mm length of stroke, 0.4 Hz of frequency, 0.5 A of applied current and 175,000 cycles. The rheological properties of MR fluid were characterized using rotational and oscillatory shear rheometer. The result showed that the rheological properties of MR fluid changed after applied in long-term operation. The changed of MR fluid also investigated through morphological characteristics using SEM and EDX.