Related papers
Monitoring system of an energy efficient school building
ITM Web of Conferences
The paper presents details regarding the implemented monitoring system of heat loss, interior comfort and energy consumption particularities of an energy efficient school building in Romania. Despite the fact that there is an emphasis on energy saving and sustainability in the building industry legislation and policies, there are still too few examples of good practice at local level. Recent trends have brought changes in how designers solve specific details like thermal insulation thicknesses and use of renewable energy but further improvement is required for a more detailed understanding of the entire building's energy balance behaviour both on overall and specific details level. Therefore, a complex monitoring system was built in a carefully designed and constructed school building in order to collect relevant real-time data of every specific part of the thermal envelope, the HVAC systems and interior comfort parameters. The main purpose of the system is to highlight the orde...
Development of a Real Time Energy Monitoring Platform User-Friendly for Buildings
Procedia Technology, 2013
This study introduces the development of a user-friendly and quite effective energy monitoring system installed in the building of School Engineering at the Universidad Autónoma de Querétaro since 2008. The metering and control software, that processes and analyzes the digitalized signals, has been developed in Integrated Development Environment (IDE) primarily MonoDevelop designed for C#, under the Linux embedded server operating system with a real time kernel. This system allows the measurement of the electric energy parameters of within a building, where the main power source has been divided into several sections for individual analysis. Measuring electric energy in sections allows the identification of higher consumption areas, the detection of abnormal conditions in voltage and current of the building. The consumption of electric energy parameters are displayed by means of an easily understood graphic interface which can be consulted via the Internet. Users who know exactly when energy consumption occurs and where it takes place are able to take more informed decisions about how to lower their energy consumption.
An Intelligent Energy Management System for Educational Buildings
International Journal of Distributed Sensor Networks, 2013
There is a wide variation in the energy consumption between different educational institutions due to the adoption of different management strategies and different levels of occupants' environmental understanding. The presence of large amounts of information and communication technology (ICT) equipment and heating, ventilation, and air conditioning (HVAC) system causes a major consumption of energy in higher education institution (HEI) buildings. The main objective of this research is to investigate the use of ICT to optimize the energy consumption in HEI buildings and reduce carbon dioxide (CO 2) emission. The first phase of the system has been implemented at King Saud University to measure energy consumption through sensors that read energy consumption of electrical appliances and devices every 10 seconds. The analysis of collected data allows us to develop and employ energy saving strategies that lead to a reduction in total energy consumption. Our preliminary results show that up to 17% of energy consumption can be reduced by simply dealing with standby energy loss of labs' computers. The novelty of this research comes from the use of a functional database approach to deal with high volume of data and query performance and the incorporation of a timetabling system in energy management system.
Use of Web Based Meters to Improve Energy Efficiency and Power Quality in Buildings
Technological Innovation for Cloud-Based Engineering Systems, 2015
During the work conducted, several buildings were analysed, in terms of energy efficiency and power quality. Two case studies are here presented: an educational building and a museum. Most of the studies were conducted recurring to traditional measurement equipment, forcing the person to travel to the site to install equipment and every time he wanted to collect data. But one of the case studies, the museum, comprised the development of an analyser (hardware and software) able to measure electric energy, temperature and humidity. This analyser has the capability to register values on a database available in the internet and issue warnings to the building manager. This allows real-time information, supporting some energy efficiency actions. The objective is to improve this model and expand its use for several buildings, providing savings in terms of time and other resources, taking advantage of cloud-based systems.
The Scientific Bulletin of Electrical Engineering Faculty
A desideratum of the society, not only in Romania, is the efficiency of the electricity consumption and its passage on green energy in a bigger proportion. This can be achieved by research on various topics chosen from different areas of the economy. One of the most widespread public institutions is education, which is why the results obtained from the research of such a subject can bring major benefits to the entire society. In general, the structure of pre-university education institutions is similar, with classrooms, laboratories equipped with the same types of electric consumers, and very close heating systems. This article proposes a method of monitoring the electrical energy and consumption parameters of a pre-university education institution in Romania. The results obtained are compared to the energy quality standards and will be the basis for a PV system that will be designed to ensure the entire energy consumption of the institution.
Smart Building: Energy Efficiency Monitor
This paper proposes the way to reduce the wastage of electricity in Universiti Tenaga Nasional (UNITEN) and mainly emphasizes in UNITEN campus such as student accommodation and colleges. The studies carried out in major places that hold the highest electricity bill which is College of Engineering, Residence Hotel@UNITEN and Student Accommodation (Amanah and Cendikiawan).
This paper presents the current state of the art regarding work performed related to the electric energy consumption for Information and Communication Technologies (ICTs) and Miscellaneous Electric Loads (MELs), in office and commercial buildings. Techniques used for measuring the energy consumption of office plug loads, and efforts for saving energy by using this equipment more rationally and efficiently are identified and categorized. Popular methods and techniques for energy metering are discussed, together with efforts to classify and benchmark office equipment. Our study reveals that many issues are still open in this domain, including more accurate, diverse and meaningful energy audits for longer time periods, taking into account device profiles, occupant behavior and environmental context. Finally, there is a need for a global consensus on benchmarking and performance metrics, as well as a need for a coordinated worldwide activity for gathering, sharing, analyzing, visualizing and exposing all the silos of information relating to plug loads in offices and commercial buildings.
2015
The University of Washington (UW) is aiming to reduce the overall electricity consumption on campus as part of its Climate Action Plan launched in 2009. To achieve this goal, UW installed 216 smart grid meters and automatic heating, ventilation, and cooling control systems across the entire campus and acquired over 200 sets of plug-load monitoring equipment. The university used the smart grid data and the monitored plug-load data to test how occupants in selected residence halls responded to receiving detailed information about their energy usage patterns, its environmental impacts, and associated costs. The experiment demonstrated that in residence halls, plug-load monitoring did not have any significant impact on the occupants' electricity consumption. Hence, there is still a need to further assess which strategies are effective in achieving long-term electricity reduction goals for the university. The goal of this study was to conduct a comparative analysis by replicating the...
Building Energy Monitoring and Analysis
2013
U.S. and China are the world's top two economics. Together they consumed one-third of the world's primary energy. It is an unprecedented opportunity and challenge for governments, researchers and industries in both countries to join together to address energy issues and global climate change. Such joint collaboration has huge potential in creating new jobs in energy technologies and services. Buildings in the US and China consumed about 40% and 25% of the primary energy in both countries in 2010 respectively. Worldwide, the building sector is the largest contributor to the greenhouse gas emission. Better understanding and improving the energy performance of buildings is a critical step towards sustainable development and mitigation of global climate change. This project aimed to develop a standard methodology for building energy data definition, collection, presentation, and analysis; apply the developed methods to a standardized energy monitoring platform, including hardware and software, to collect and analyze building energy use data; and compile offline statistical data and online real-time data in both countries for fully understanding the current status of building energy use. This helps decode the driving forces behind the discrepancy of building energy use between the two countries; identify gaps and deficiencies of current building energy monitoring, data collection, and analysis; and create knowledge and tools to collect and analyze good building energy data to provide valuable and actionable information for key stakeholders. Key research findings were summarized as follows: 1. Identified the need for a standard data model and platform to collect, process, analyze, and exchange building performance data due to different definitions of energy use and boundary, difficulty in exchanging data, and lack of current standards. 2. Compared energy monitoring systems to identify gaps, including iSagy, Pulse Energy, SkySpark, sMap, EPP, ION, and Metasys. 3. Contributed to develop a standard data model to represent energy use in buildings (ISO standard 12655 and a Chinese national standard) 4. Determined that buildings in the United States and China are very different in design, operation, maintenance, occupant behavior: U.S. buildings have more stringent comfort standards regarding temperature, ventilation, lighting, and hot-water use and therefore higher internal loads and operating hours, and China buildings having higher lighting energy use, seasonal HVAC operation, more operators, more use of natural ventilation, less outdoor ventilation air, and wider range of comfort temperature. 5. Completed data collection for six office buildings, one in UC Merced campus, one in Sacramento, one in Berkeley, one in George Tech campus, and two in Beijing. 6. Compiled a source book of 10 selected buildings in the United States and China with detailed descriptions of the buildings, data points, and monitoring systems, and containing energy analysis of each building and an energy benchmarking among all buildings. 7. Recognized limited availability of quality data, particularly with long periods of time-interval data, and general lack of value for good data and large datasets. 8. Compiled a building energy database, with detailed energy end use at 1-hour or 15-minute time interval, of six office buildings-four in the U.S. and two in China. The database is available to the public and is a valuable resource for building research. 9. Developed methods and used them in data analysis of building performance for the five buildings with adequate data, including energy benchmarking, profiling (daily, weekly, monthly), and diagnostics. 10. Recommended energy efficiency measures for building retrofit in both countries. U.S. buildings show more potential savings by reducing operation time, reducing plug-loads, expanding comfort temperature range, and turning off lights or equipment when not in use; while Chinese buildings can save energy by increasing lighting system efficiency, and improving envelope insulation and HVAC equipment efficiency. The research outputs from the project can help better understand energy performance of buildings, improve building operations to reduce energy waste and increase efficiency, identify retrofit opportunities for existing buildings, and provide guideline to improve the design of new buildings. The standardized energy monitoring and analysis platform as well as the collected real building data can also be used for other CERC projects that need building energy measurements, Research Team and Collaboration The joint research team (Table 1) includes the LBNL team, the ORNL team, the U.S. industry partners, the Tsinghua team and the China industry partners. Tianzhen Hong of LBNL led the U.S. side research and Jianjun Xia of Tsinghua University led the China side research. Richard Karney and Yi Jiang served as the senior technical advisors for the project. The research team had biweekly conference calls to discuss project progress and resolve issues. The team organized a series of workshops (Appendix B) to exchange research findings, seek inputs and comments from researchers, practitioners, industry partners, HVAC manufacturers, government agencies, and other stakeholders. The joint research work also made significant contribution to the IEA Annex 53. Exchanged students from Tsinghua University stayed at LBNL for a few months to work on joint technical tasks.
2014
This paper presents the current state of the art regarding work performed related to the electric energy consumption for Information and Communication Technologies (ICT) and Miscellaneous Electric Loads (MELs), in office and commercial buildings. Techniques used for measuring the energy consumption of office plug loads, and efforts for saving energy by using this equipment more rationally and efficiently are identified and categorized. Popular methods and techniques for energy metering are discussed, together with efforts to classify and benchmark office equipment. Our study reveals that many issues are still open in this domain, including more accurate, diverse and meaningful energy audits for longer time periods, taking into account device profiles, occupant behavior and environmental context. Finally, there is a need for a global consensus on benchmarking and performance metrics, as well as a need for a coordinated worldwide activity for gathering, sharing, analyzing, visualizing...