An Evaluation of a Low Dose Rate (LDR) Brachytherapy Procedure Using a “Systems Engineering & Error Analysis Methodology for Health Care (original) (raw)

2012 Symposium on Human Factors and Ergonomics in Health Care An Evaluation of a Low Dose Rate (LDR) Brachytherapy Procedure using a "Systems Engineering & Error Analysis Methodology for Health Care" (SEABH)

Liam Chadwick

View PDFchevron_right

Implementation of failure mode and effective analysis for high dose rate brachytherapy at Tata Memorial Hospital, Mumbai, India

jamema swamidas

Cancer/Radiothérapie, 2018

View PDFchevron_right

Methodology for Health Care " (SEABH)

Enda Fallon

2016

View PDFchevron_right

Electronic Intracavitary Brachytherapy Quality Management based on Risk Analysis: The Report of AAPM TG 182

Zoubir Ouhib

Medical Physics

View PDFchevron_right

Patient safety program and incident review of high-dose-rate brachytherapy at an academic center in Thailand

kantarat rojanapan

Journal of Contemporary Brachytherapy

View PDFchevron_right

Evaluation of Safety in a Radiation Oncology Setting Using Failure Mode and Effects Analysis

Lilly Engineer

International Journal of Radiation Oncology*Biology*Physics, 2009

View PDFchevron_right

The American Brachytherapy Society prostate brachytherapy LDR/HDR simulation workshops: Hands-on, step-by-step training in the process of quality assurance

Peter Orio

Brachytherapy, 2020

View PDFchevron_right

Is it necessary to perform week three dosimetric analysis in low-dose rate brachytherapy for prostate cancer when day 0 dosimetry is done? A quality assurance assessment

Richard Greenberg, Nicholas G Zaorsky

Brachytherapy, 2014

View PDFchevron_right

Physics aspects of safety assurance in high dose rate brachytherapy: quality control testing and implementation of dosimetry audit

Antony Palmer

View PDFchevron_right

A single institution analysis of low-dose-rate brachytherapy: 5-year reported survival and late toxicity outcomes

Damien Bolton

Journal of contemporary brachytherapy, 2018

View PDFchevron_right

Potential role of various dosimetric quality indicators in prostate brachytherapy

Gregory Merrick

International Journal of Radiation Oncology*Biology*Physics, 1999

View PDFchevron_right

Real-time in vivo dosimetry in high dose rate prostate brachytherapy

Arielle Mamo

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, 2016

View PDFchevron_right

Independent brachytherapy plan verification software: improving efficacy and efficiency

Joseph Killoran

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, 2014

View PDFchevron_right

A review of safety, quality management, and practice guidelines for high-dose-rate brachytherapy: executive summary

Beth Erickson, Mark Rivard

Practical radiation oncology

View PDFchevron_right

A simple analytical method for heterogeneity corrections in low dose rate prostate brachytherapy

Frank-André Siebert

Physics in Medicine and Biology, 2015

View PDFchevron_right

Results from the Quality Research in Radiation Oncology (QRRO) survey: Evaluation of dosimetric outcomes for low-dose-rate prostate brachytherapy

Lisa Morikawa, Phillip Devlin

Brachytherapy, 2013

View PDFchevron_right

Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM

Mark Rivard

Radiotherapy and Oncology, 2014

View PDFchevron_right

Independent evaluation of an in-house brachytherapy treatment planning system using simulation, measurement and calculation methods

Zahra Siavashpour

Journal of applied clinical medical physics / American College of Medical Physics, 2012

View PDFchevron_right

Initial analysis of Pro-Qura: A multi-institutional database of prostate brachytherapy dosimetry

Wayne Butler

Brachytherapy, 2007

View PDFchevron_right

Initial clinical assessment of "center-specific" automated treatment plans for low-dose-rate prostate brachytherapy

Don Yee

Brachytherapy, 2017

View PDFchevron_right

Validation of automated post-adjustments of HDR prostate brachytherapy treatment plans by quantitative measures and oncologist observer study

Frida Dohlmar

Brachytherapy

View PDFchevron_right

Doses to Organs at Risk Calculated Using Plato and Oncentra Softwares in Intracavitary Brachytherapy

reduan abdullah

Jurnal Sains Kesihatan Malaysia, 2021

View PDFchevron_right

Using failure mode and effects analysis (FMEA) to generate an initial plan check checklist for improved safety in radiation treatment

Prema Rassiah

Journal of Applied Clinical Medical Physics, 2020

View PDFchevron_right

A Review of Healthcare Failure Mode and Effects Analysis (HFMEA) in Radiotherapy

E. Tomarchio

Health Physics, 2016

View PDFchevron_right