An Evaluation of a Low Dose Rate (LDR) Brachytherapy Procedure Using a “Systems Engineering & Error Analysis Methodology for Health Care (original ) (raw )2012 Symposium on Human Factors and Ergonomics in Health Care An Evaluation of a Low Dose Rate (LDR) Brachytherapy Procedure using a "Systems Engineering & Error Analysis Methodology for Health Care" (SEABH)
Liam Chadwick
View PDFchevron_right
Implementation of failure mode and effective analysis for high dose rate brachytherapy at Tata Memorial Hospital, Mumbai, India
jamema swamidas
Cancer/Radiothérapie, 2018
View PDFchevron_right
Methodology for Health Care " (SEABH)
Enda Fallon
2016
View PDFchevron_right
Electronic Intracavitary Brachytherapy Quality Management based on Risk Analysis: The Report of AAPM TG 182
Zoubir Ouhib
Medical Physics
View PDFchevron_right
Patient safety program and incident review of high-dose-rate brachytherapy at an academic center in Thailand
kantarat rojanapan
Journal of Contemporary Brachytherapy
View PDFchevron_right
Evaluation of Safety in a Radiation Oncology Setting Using Failure Mode and Effects Analysis
Lilly Engineer
International Journal of Radiation Oncology*Biology*Physics, 2009
View PDFchevron_right
The American Brachytherapy Society prostate brachytherapy LDR/HDR simulation workshops: Hands-on, step-by-step training in the process of quality assurance
Peter Orio
Brachytherapy, 2020
View PDFchevron_right
Is it necessary to perform week three dosimetric analysis in low-dose rate brachytherapy for prostate cancer when day 0 dosimetry is done? A quality assurance assessment
Richard Greenberg , Nicholas G Zaorsky
Brachytherapy, 2014
View PDFchevron_right
Physics aspects of safety assurance in high dose rate brachytherapy: quality control testing and implementation of dosimetry audit
Antony Palmer
View PDFchevron_right
A single institution analysis of low-dose-rate brachytherapy: 5-year reported survival and late toxicity outcomes
Damien Bolton
Journal of contemporary brachytherapy, 2018
View PDFchevron_right
Potential role of various dosimetric quality indicators in prostate brachytherapy
Gregory Merrick
International Journal of Radiation Oncology*Biology*Physics, 1999
View PDFchevron_right
Real-time in vivo dosimetry in high dose rate prostate brachytherapy
Arielle Mamo
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, 2016
View PDFchevron_right
Independent brachytherapy plan verification software: improving efficacy and efficiency
Joseph Killoran
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, 2014
View PDFchevron_right
A review of safety, quality management, and practice guidelines for high-dose-rate brachytherapy: executive summary
Beth Erickson , Mark Rivard
Practical radiation oncology
View PDFchevron_right
A simple analytical method for heterogeneity corrections in low dose rate prostate brachytherapy
Frank-André Siebert
Physics in Medicine and Biology, 2015
View PDFchevron_right
Results from the Quality Research in Radiation Oncology (QRRO) survey: Evaluation of dosimetric outcomes for low-dose-rate prostate brachytherapy
Lisa Morikawa , Phillip Devlin
Brachytherapy, 2013
View PDFchevron_right
Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM
Mark Rivard
Radiotherapy and Oncology, 2014
View PDFchevron_right
Independent evaluation of an in-house brachytherapy treatment planning system using simulation, measurement and calculation methods
Zahra Siavashpour
Journal of applied clinical medical physics / American College of Medical Physics, 2012
View PDFchevron_right
Initial analysis of Pro-Qura: A multi-institutional database of prostate brachytherapy dosimetry
Wayne Butler
Brachytherapy, 2007
View PDFchevron_right
Initial clinical assessment of "center-specific" automated treatment plans for low-dose-rate prostate brachytherapy
Don Yee
Brachytherapy, 2017
View PDFchevron_right
Validation of automated post-adjustments of HDR prostate brachytherapy treatment plans by quantitative measures and oncologist observer study
Frida Dohlmar
Brachytherapy
View PDFchevron_right
Doses to Organs at Risk Calculated Using Plato and Oncentra Softwares in Intracavitary Brachytherapy
reduan abdullah
Jurnal Sains Kesihatan Malaysia, 2021
View PDFchevron_right
Using failure mode and effects analysis (FMEA) to generate an initial plan check checklist for improved safety in radiation treatment
Prema Rassiah
Journal of Applied Clinical Medical Physics, 2020
View PDFchevron_right
A Review of Healthcare Failure Mode and Effects Analysis (HFMEA) in Radiotherapy
E. Tomarchio
Health Physics, 2016
View PDFchevron_right