Spectroscopic Diagnostics of High Pulse Discharge in the Helium-Nitrogen Gas Mixtures (original) (raw)
Related papers
The effect of electrode heating on the discharge parameters in complex plasma experiments
Plasma Sources Science and Technology, 2011
Thermophoresis is a tool often applied in complex plasma experiments. One of the usual stated benefits over other experimental tools is that electrode temperature changes required to induce thermophoresis do not directly influence the plasma parameters. From electronic data, plasma emission profiles in the sheath, and Langmuir probe data in the plasma bulk, we conclude that this assumption does not hold. An important effect on the levitation of dust particles in argon plasma is observed as well. The reason behind the changes in plasma parameters seems to be the change in neutral atom density accompanying the increased gas temperature while running at constant pressure.
Investigation of a -discharge plasma under an increased pressure of Ar and in narrow tubes
Journal of Physics D: Applied Physics, 1998
The electrokinetic characteristics (the electron energy distribution function, the strength of the longitudinal electric field and the concentration and average energy of electrons) are measured and calculated in a (Hg + Ar)-discharge plasma under a high pressure of argon (up to 30 Torr) and in narrow tubes (the tube radius is less than 1.0 cm). A simple method of treating the second derivative of the probe current with respect to the probe potential is proposed for a straightforward way to obtain the electron energy distribution function under a high pressure of a gas. It is shown that the main assumptions on which modelling of the plasma of mercury luminescent lamps is based are also valid for the plasma in question. This leads to the existence of special similarity laws and gives a new possibility for diagnostics based on the similarity properties of the plasma. The approach proposed in the work can be easily extended to the mixtures of mercury vapour and other rare gases.
Methods for spectroscopic measurement of electric field in atmospheric pressure helium discharges
European Physical Journal-applied Physics, 2017
A short overview of the emission spectroscopy methods for measuring the macroscopic electric field in high pressure discharges with helium is given. The occurrence of macroscopic electric field is a consequence of the space charge buildup. It is a common feature of discharge sheaths, streamer heads and double layers. The spectroscopic methods are based on polarization-dependent Stark splitting and shifting of atomic lines in the presence of a relatively strong electric field. For high pressure discharges Stark shifting of helium lines and their forbidden counterparts is used. The advantage of Stark methods is their ab initio basis which makes them independent on other plasma parameters. A different method for field measurement, based on the helium line ratio, can be applied in cases where the Stark method cannot be used.
Plasma Science and Technology
In a steady-state plasma, the loss rate of plasma particles to the chamber wall and surfaces in contact with plasma is balanced by the ionization rate of background neutrals in the hot-filament discharges. The balance between the loss rate and ionization rate of plasma particles (electrons and ions) maintains quasi-neutrality of the bulk plasma. In the presence of an external perturbation, it tries to retain its quasi-neutrality condition. In this work, we studied how the properties of bulk plasma are affected by an external DC potential perturbation. An auxiliary biased metal disk electrode was used to introduce a potential perturbation to the plasma medium. A single Langmuir probe and an emissive probe, placed in the line of the discharge axis, were used for the characterization of the bulk plasma. It is observed that only positive bias to the auxiliary metal disk increases the plasma potential, electron temperature, and plasma density but these plasma parameters remain unaltered ...
In this study, a systematic spectroscopic characterization of a low-temperature plasma (LTP) probe operated with He/N 2 gas mixtures is carried out. The influence of several experimental parameters (e.g., different He/N 2 gas mixtures, discharge voltage, and gas flow rate) on the dielectric-barrier discharge afterglow was studied. It was found that an increase of the nitrogen concentration in the helium discharge gas (to values higher than 0.5% N 2) leads to a significant decay of N 2 + , He, and O emission intensities. At 1% N 2 and 99% He, oxygen emission bands were not detectable and intensity of He and N 2 + emission bands were reduced by approximately five times compared to features in a 100% He discharge. Interestingly, the opposite trend was observed for NO, OH, and N 2 species. Here, increasing the N 2 fraction in the discharge gas mixture led to an enhancement of emission intensities. Maximum emission bands intensities of OH, NO, and N 2 were detected at N 2 concentrations of 0.5, 0.6, and 1.0%, respectively. A further increase of the N 2 fraction leads to a decrease of emission intensities for all observed species (OH, NO, N 2 , He, and N 2 +). In general, an increase in discharge gas flow rate resulted in a significant increase of NO emission band intensities for all N 2 /He mixtures tested. However, only a minor effect was observed for N 2 emission bands. Increasing the discharge voltage resulted in an increase of emission intensities of all detected species. Combined with spatially resolved investigations of the afterglow, these results are considered helpful to further optimize LTP performance. This is especially important for portable and direct analysis instrumentation, where LTP can be used as the ionization source and lower helium gas consumption is desirable because of cost and availability.
Diagnostic of plasma discharge parameters in helium filled dielectric barrier discharge
Journal of Theoretical and Applied Physics, 2012
This paper reports the plasma discharge analysis of a dielectric barrier discharge (DBD) source. Helium is used as a working gas. The analysis is performed at fixed working pressure and operating frequency. The investigations are carried out using sinusoidal supply for the generation of discharges where two current pulses have been observed with different polarities in one period. A homogeneous type of discharge has been observed for different operating conditions in this DBD source. Since in situ diagnostics are not possible due to the small geometries in the used DBD source, the electrical measurements and spectroscopic analysis of the discharge have been performed to analyse the plasma discharge. The electrical analysis has been carried out using equivalent electrical circuit model. The plasma density and temperature within the discharge have been estimated using line ratio technique of the observed visible neutral helium lines. The estimated electron plasma density is found to be in close proximity with the plasma simulation code 'OOPIC Pro'.
In this work the determination of plasma parameters of a pulsed-arc discharge by using an electrostatic double probe is presented. The system to generate the plasma is composed mainly of a reaction chamber, where the electrodes of different materials Ti, Zr, Al were placed in order to identify the variation of the plasma parameters when the cathode material is changed. An automatic system has been implemented for acquiring data starting from the bias of a double electrostatic probe. This system allowed registering complete curves of current-voltage in relatively short times 30 ms. The electron density n e and electron temperature T e can be extracted from the I-V characteristic curves obtained. The advantage of this technique is its facility to provide the whole quantity of " in situ " information, which can be compared with the theoretical results using numeric methods for the I-V curves simulation. By means of a suitable fit this allowed the determination of the plasma parameters. The values obtained for T e were in the order of 1 eV and for n e of about 10 13 cm −3. A significant variation for n e was not found.
Diagnostics and application of the high frequency plasma pencil
Plasma Chemistry and Plasma Processing, 2001
The so called high frequency plasma pencil is a source of highly actiûe enûironment (electrons, ions, reactiûe radicals, excited atoms, and molecules) which can be generated at atmospheric, reduced or increased pressure, preserûing a good control of the performance. The discharge can be either unipolar or bipolar. The properties of unipolar atmospheric pressure discharges are discussed on the basis of simple theoretical considerations and electric probe measurements. The plasma pencil discharge is studied by optical emission spectroscopy in the gas phase at atmospheric pressure as well as immersed in liquid using argon as a working gas. From the emission spectra the electron, ûibrational and rotational temperatures are calculated for ûarious distances from the plasma pencil electrode. Seûeral technological applications like restoration of archaeological glass and metal artifacts, fragmentation of molecules for microelectrophoresis and plasma polymerization are summarized. An adûantage of the plasma pencil is that it can be easily operated and controlled.