In-situ diagnostic of polypropylene degradation by electrical discharge induced luminescence at room temperature (original) (raw)
Related papers
Using heated probes in plasma polymerising discharges
Surface & Coatings Technology, 2004
Using a heated probe, a technique has been developed to measure the spatial variation of the electron temperature (T ) plasma e density (N ), floating (V ), and plasma potentials (V ), and the electron energy distribution function (eedf) in low-pressure e f p polymerising plasma. During the non-data acquisition times, the probe was heated using an external current, so minimising deposition of an insulating layer on its surface. Typically the insulating film deposition rate was between 2 and 4 nm s y1 depending on the discharge conditions. To obtain a Langmuir probe characteristic (and derive the quantities N , T , V and eedf), e e f the heating current was switched off and the data collected over a short time (10 to 30 s). By heating the probe to strong electron emission, it was also possible to obtain an accurate measurement of V . The technique has been applied to a new two-stage p reactor (source and diffusion chambers separated by a mesh) in which acrylic acid is plasma polymerised to form thin films with functional surface chemistry at low pressure (5.2 Pa). The probe results show that in the polymerising chamber, with increasing distance from the mesh, (15 to 70 mm), N fall from 1.7=10 to 2=10 m and T falls from 3.7 to 1.3 eV. However, at a 14 13 y3 e e fixed distance of 70 mm, with increasing discharge power, T remains constant, while N increases over an order of magnitude. e e
Characterisation of plasma polymers by thermoluminescence
Surface & Coatings Technology, 2006
Thin plasma polymer films were deposited using the pulsed plasma mode. These plasma polymers should possess a more regular structure than those produced by the conventional continuous-wave (cw) mode, because of lower monomer fragmentation caused by the plasma pulses and the chemical chain propagation during the plasmaless (free!) periods. The thermoluminescence method was applied to functional groups carrying plasma polymer layers which are used in medical technology. Examples are formation of biocompatible, biosensoric and bioactive coatings or in metal polymer composites such as adhesion-promoting interlayers.
1998
Recently, a glow like dielectric controlled barrier discharge (GDBD) working at atmospheric pressure has been observed. Such a discharge could replace a filamentary dielectric controlled barrier discharge (FDBD) used in corona treatment systems to improve the wettability or the adhesion of polymers. So it is of interest to compare these two types of discharges and their respective effect on a polymer surface. This is the aim of an extensive study we have undertaken. The first step presented here is the comparison of a filamentary discharge in air with a glow discharge in helium. Helium is the most appropriate gas to realize a glow discharge at atmospheric pressure. Air is the usual atmosphere for a corona treatment. The plasma was characterized by emission spectroscopy and current measurements. The surface transformations were indicated by the water contact angle, the leakage current measurement and the X-ray photoelectron spectroscopy. Results show that the helium GDBD is better than air FDBD to increase polypropylene wettability without decreasing the bulk electrical properties below a certain level. Contact angle scattering as well as leakage current measurements confirm that the GDBD clearly results in more reproducible and homogeneous treatment than the FDBD.
Surface and Interface Analysis, 2010
This study focuses on the surface treatment of polymer films (polypropylene and polyethylene terephthalate) with a remote atmospheric pressure d.c. glow discharge operating in ambient air. The set-up used can be easily upgraded to industrial dimensions and simulates in-line processing due to the rotating drum used to mount the samples on. The discharge was characterized by measuring the voltage-current curve. From this curve, three regimes can be distinguished: corona regime, glow regime and spark regime. The voltage is adjusted so that the plasma operates in the glow regime and the treatment effects are analyzed by water contact angle and XPS measurements. It is shown that the remote plasma source is capable of reducing the contact angle and making the surface of the polymers more hydrophilic. The influence of the distance of the sample to the electrodes and the power is studied. By XPS measurements, the chemical composition of the surface after treatment is determined for different operating conditions. On none of the analyzed samples, nitrogen was detected. The main effect of the treatment is the incorporation of oxygen. Angle-resolved XPS measurements show that the composition of the top atomic layers is significantly different from that of the underlying layers. The functional groups grafted by the plasma treatment were identified by the deconvolution of the C1s peak.
Journal of Applied Physics, 1997
The light emitted by an insulating material once its surface has been submitted to a cold plasma, plasma-induced luminescence is investigated on polypropylene films at low temperature. An analysis of the integral and wavelength resolved light is carried out. The kinetical evolution of the spectrum after plasma interaction are reported and analyzed. Investigation of the photo-and chemiluminescence spectra of the material shows that plasma-induced luminescence has three spectral components, each having different excitation mechanisms and thus different kinetics. The fastest is due to the ultraviolet irradiation during plasma contact, the second is dominated by radical chemistry producing carbonyl groups, and the third, with the slowest kinetics, is due to carrier recombination on the most conjugated chromophores which are preferentially charged by the plasma. To confirm the interpretation of plasma induced luminescence spectrum, the first results concerning short and long plasma interaction are considered.
Luminescence of plasma-treated polymer surfaces: a tool for investigating surface modifications
Journal of Physics D: Applied Physics, 1993
The aim of this wmmunication is to present the possibilities offered by luminescence techniques of pointing out polymer surface transformations induced by wld-plasma treatments. The surface modifications can be monnored in situ inside the plasma reactor. Measurements are carried out as a function d time, wavelength and temperature. Results obtained for polypropylene films treated with an atmospheric pressure glow discharge show that this technique Is sensniie to newly ueated chemical functions as well as uoss linking and Carrier implantations, that is to say, to all surface transformations induced by a wid plasma.
Diagnostics and application of the high frequency plasma pencil
Plasma Chemistry and Plasma Processing, 2001
The so called high frequency plasma pencil is a source of highly actiûe enûironment (electrons, ions, reactiûe radicals, excited atoms, and molecules) which can be generated at atmospheric, reduced or increased pressure, preserûing a good control of the performance. The discharge can be either unipolar or bipolar. The properties of unipolar atmospheric pressure discharges are discussed on the basis of simple theoretical considerations and electric probe measurements. The plasma pencil discharge is studied by optical emission spectroscopy in the gas phase at atmospheric pressure as well as immersed in liquid using argon as a working gas. From the emission spectra the electron, ûibrational and rotational temperatures are calculated for ûarious distances from the plasma pencil electrode. Seûeral technological applications like restoration of archaeological glass and metal artifacts, fragmentation of molecules for microelectrophoresis and plasma polymerization are summarized. An adûantage of the plasma pencil is that it can be easily operated and controlled.
2007
Electrical and temporally and spatially resolved emission studies of the 340mm x 300mm Dow Corning Plasma Solutions LabLine™ system discharge are reported. Measurements were made with discharges created in both flowing helium and in helium with oxygen and also with and without PET in the inter-electrode gap. Probes measured the time dependence of the discharge current and applied voltage. Time and space resolved plasma emission was observed by imaging specific plasma regions onto the entrance of an ICCD, triggered to open, at well defined phases of the applied voltage cycle, for times of typically100 ns. The results show that large scale, spatially inform discharges can be created under conditions used for polymer film processing.