Scanning electron microscope dimensional metrology using a model-based library
Surface and Interface Analysis, 2005
The semiconductor electronics industry places significant demands upon secondary electron imaging to obtain dimensional measurements that are used for process control or failure analysis. Tolerances for measurement uncertainty and repeatability are smaller than the spatial resolution of edges in the scanning electron microscope (SEM) that is used to perform the measurements. Image processing techniques, historically used to identify edge locations, are inadequate under these conditions. An alternative approach, based upon Monte Carlo electron transport modeling to assign edge positions, has been developed. The specimen shape is parameterized, and parameters are iteratively adjusted to produce the best least squares fit to the measured image. Because Monte Carlo simulators are too slow to be used directly in such an iterative calculation, the Monte Carlo technique is used relatively few times to construct a library of results for parameters spanning the process space of interest. A function that interpolates the library then becomes a surrogate that is used to rapidly compute the model function as needed. This procedure has yielded measurement results from top-down SEM images that are in good agreement with cross-section measurements and that have as much as a factor of 3 better same-site repeatability than the more traditional techniques. Published in 2005 by John Wiley & Sons, Ltd.
The Scanning Confocal Electron Microscope
Microscopy Today
Imaging of sub-micron , sub-surface features of thick optically dense materials at high resolution has always been a difficult and/or time consuming task in materials research. For the most part this role has been relegated to technologically complex and expensive instrumentation having highly penetrating radiation, such as the synchrotron- based Scanning Transmission X-ray Microscope (STXM) or involves the careful preparation of thin cross-section slices for study using the Transmission/Scanning Transmission Electron Microscope (TEM/STEM).
Magnification-continuous static calibration model of a scanning-electron microscope
Journal of Electronic Imaging, 2012
We present a new calibration model of both static distortion and projection for a scanning-electron microscope (SEM). The proposed calibration model depends continuously on the magnification factor. State-of-the-art methods have proposed models to solve the static distortion and projection model but for a discrete set of low and high magnifications: at low magnifications, existing models assume static distortion and perspective projection. At high magnifications, existing models assume an orthogonal projection without presence of static distortion. However, a magnification-continuous model which defines continuous switch from low to high magnifications has not yet been proposed. We propose a magnification-continuous static calibration model of the SEM. The static distortion and intrinsics of the projection matrix are modeled by partial differential equations (PDEs) with respect to magnification. The approach is applied with success to the JEOL-JSM 820 in a secondary electron imaging mode for magnification ranging from 100× to 10k×. The final RMS reprojection error is about 0.9 pixels. This result together with two application-based experiments: the consistent measurements of the bending of a cantilever and a 3-D reconstruction of a nano-ball emphasize the relevance of the proposed approach.
Microscopy and Microanalysis, 2013
A method is presented for determining the point spread function (PSF) of an electron beam in a scanning electron microscope for the examination of near planar samples. Once measured, PSFs can be used with two or more low-resolution images of a selected area to create a high-resolution reconstructed image of that area. As an example, a 4× improvement in resolution for images is demonstrated for a fine gold particle sample. Since thermionic source instruments have high beam currents associated with large probe sizes, use of this approach implies that high-resolution images can be produced rapidly if the probe diameter is less of a limiting factor. Additionally, very accurate determination of the PSFs can lead to a better understanding of instrument performance as exemplified by very accurate measurement of the beam shape and therefore the degree of astigmatism.
Optimizing the environment for sub-0.2 nm scanning transmission electron microscopy
Journal of electron microscopy, 2001
Sub-0.2 nm probes can now be readily obtained on Schottky field-emission microscopes. However, environmental instabilities are proving to be the limiting factors for atomic resolution spectroscopy and distortion-free annular-dark field imaging. This is a result of the long acquisition times and the serial nature of the scanning system where instabilities result in image distortions rather than reductions in contrast. Troubleshooting the most common environmental problems is discussed here. In addition to the expected sensitivity to mechanical vibration, electromagnetic interference and temperature variations, air-pressure fluctuations are found to have a significant impact on microscopes with side-entry goiniometers.
Scanning probe microscopy as a metrology method in micro- and nanostructure investigations
2000
Evolution of many high technologies such as microelectronics, microsystem technology and nanotechnology involves design, application and testing of technical structures, whose size is being decreased continuously. Scanning probe microscopes (SPM) are therefore increasingly used as diagnostic and measurement instruments. Consequently the demand for standardized calibration routines for this kind of equipment rises. Up to now, there has been no in
Simulations and measurements in scanning electron microscopes at low electron energy
Scanning, 2016
The advent of new imaging technologies in Scanning Electron Microscopy (SEM) using low energy (0-2 keV) electrons has brought about new ways to study materials at the nanoscale. It also brings new challenges in terms of understanding electron transport at these energies. In addition, reduction in energy has brought new contrast mechanisms producing images that are sometimes difficult to interpret. This is increasing the push for simulation tools, in particular for low impact energies of electrons. The use of Monte Carlo calculations to simulate the transport of electrons in materials has been undertaken by many authors for several decades. However, inaccuracies associated with the Monte Carlo technique start to grow as the energy is reduced. This is not simply associated with inaccuracies in the knowledge of the scattering cross-sections, but is fundamental to the Monte Carlo technique itself. This is because effects due to the wave nature of the electron and the energy band structu...
Physics of Advanced Materials Winter School 2008 Electron Microscopy: The Basics
Since its invention, electron microscope has been a valuable tool in the development of scientific theory and it contributed greatly to biology, medicine and material sciences. This wide spread use of electron microscopes is based on the fact that they permit the observation and characterization of materials on a nanometer (nm) to micrometer (µm) scale. This paper presents the basic theory for electron microscopy, focusing on the two basic types of Ems; SEM, TEM.
Spatiotemporal Calibration of Electron Microscopes
Modern Electron Microscopy in Physical and Life Sciences, 2016
This chapter presents a method of calibration for scanning electron microscopes (SEMs). The described calibration method is a twofold step. The first step evaluates the dynamical drift parameters. The second step estimates the parameters of the geometric projection and the static distortion. Both steps process the calibration parameters across the range of magnification scales, thanks to a representation with partial differential equations. The chapter is provided with an example of calibration of the JEOL JSM 820 and an example of application in metrology. The presented method is not the unique way of calibrating an SEM and can be a good start to inspire other methods of calibration.