Environmental monitoring in four European museums (original) (raw)

Abstract

In a European multidisciplinary research project concerning environmental diagnostics, museums have been selected, having di!erent climate and pollution conditions, i.e.: Correr Museum, Venice (Italy); Kunsthistorisches Museum, Vienna (Austria); Royal Museum of Fine Arts, Antwerp (Belgium); Sainsbury Centre for Visual Arts, Norwich (UK). Some "eld tests investigated the microclimate, the gaseous and particulate air pollution and the biological contamination to suggest mitigative techniques that may reduce the potential for damage in the long run. Potential risk factors are generated by imbalance in temperature and humidity, generated by heating, air conditioning or ventilating system (HVAC), or the building structures, exchange of outside air, or large visitor numbers. HVAC may also enhance indoor gaseous pollution. Plants and carpets represent potential niches for bacterial colonisation. Pollutants and particles have been recognised having partly external and partly internal origin. Tourism has a direct negative impact, i.e. transport of external particles, release of heat, vapour and CO , as well as generation of turbulence, which increases the deposition rate of particulate matter. However, the main problem is that the microclimate has been planned for the well being of visitors during only the visiting time, disregarding the needs of conservation that requires a constant climate by day and by night. In some of these cases, better environmental niches have been obtained with the help of showcases. In other cases, showcases worsened the situation, especially when incandescent lamps were put inside.

Loading...

Loading Preview

Sorry, preview is currently unavailable. You can download the paper by clicking the button above.

References (31)

  1. Alten, H., 2000. Collection Caretaker. How temperature and relative humidity a!ect collection deterioration rates, North- ern States Conservation Center Publications, available on the World Wide Web: (http://www.collectioncare.org/ pubs/v2n2p1.html'.
  2. Altenburger, P., Kampfer, P., Makristathis, A., Lubitz, W., Busse, H.-J., 1996. Classi"cation of bacteria isolated from a medieval wall painting. Journal of Biotechnology 47, 39}52.
  3. Bernardi, A., Camu!o, D., 1995a. U$zi Gallery in Florence: a comparison between two di!erent air conditioning sys- tems. Science and Technology for Cultural Heritage 4 (2), 11}22.
  4. Bernardi, A., Camu!o, D., 1995b. Microclimate in the Chiericati Palace Municipal Museum, Vicenza. Museum Management and Curatorship 14, 5}18.
  5. Blades, N.W., Cassar, M., Oreszczyn, T., Croxford, B., 2000. Preventive conservation strategies for sustainable urban pol- lution control in museums, In: Roy, A., Smith, P. (Eds), IIC 18th International Congress, Melbourne 2000, Tradition and Innovation: Advances in Conservation. IIC, London, pp. 24}28.
  6. Bondarenko, I., Treiger, B., Van Grieken, R., Van Espen, P., 1996. IDAS: a Windows based software package for cluster analysis. Spectrochimica Acta 51B, 441}456.
  7. Brimblecombe, P., 1994. The balance of environmental factors attacking artifacts. In: Krumbein, W.E., Brimblecombe, P., Cosgrove, D.E., Staniforth, S. (Eds), Durability and Change*The Science, Responsibility and Cost of Sustaining Cultural Heritage. Wiley, Chichester, pp. 67}79.
  8. Brimblecombe, P., Blades, N., Camu!o, D., Sturaro, G., Valen- tino, A., Gysels, K., Van Grieken, R., Busse, H.J, Wieser, M., Kim, O., Ulrych, U., 1999. The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK. Indoor Air 9, 146}164.
  9. Camu!o, D., 1983. Indoor dynamic climatology: investigations on the interactions between walls and indoor environment. Atmospheric Environment 17, 1803}1809.
  10. Camu!o, D., 1998. Microclimate for Cultural Heritage. Elsevier, Amsterdam, 415pp.
  11. Camu!o, D., Bernardi, A., 1995. The microclimate of the Sistine Chapel. Joint edition Bollettino Geofosico and European Cultural Heritage Newsletter on Research, Vol. 9, pp. 7}33.
  12. Camu!o, D., Bernardi, A., Cocheo, C., Da!ara, C., Sturaro, G., Valentino, A., 1998. 1 relazione annuale sottoprogetto 5.2.2, Progetto Finalizzato Beni Culturali, SP5, CNR, Roma, pp. 31}34.
  13. Camu!o, D., Brimblecombe, P., Van Grieken, R., Busse, H.J., Sturaro, G., Valentino, A., Bernardi, A., Blades, N., Shooter, D., De Bock, L., Gysels, K., Wieser, M., Kim, O., 1999. Indoor air quality at the Correr Museum, Venice, Italy. Science of the Total Environment 236, 135}152.
  14. Camu!o, D., Sturaro, G., Valentino, A., 2000. Showcases: a really e!ective mean for protecting artworks? Ther- mochimica Acta 365 (1}2), 65}77.
  15. Davies, T.D., Ramer, B., Kaspyzok, G., Delany, A.C., 1984. Indoor/outdoor ozone concentrations at a contemporary art gallery. Journal of the Air Pollution Control Association 31 (2), 135}137.
  16. De Bock, L.A., Van Grieken, R.E., Camu!o, D., Grime, G.W., 1996. Microanalysis of museum aerosols to elucidate the soiling of paintings: case of the Correr Museum, Venice, Italy. Environmental Science and Technology 30, 3341}3350.
  17. Erhardt, D., Mecklenburg, M., 1994. Relative humidity re-exam- ined. In: Roy, A., Smith, P. (Eds), IIC Preprints of the Contributions to the Ottawa Congress, 12}16 September 1994, Preventive Conservation Practice, Theory and Re- search, IIC, London, pp. 32}38.
  18. Grzywacz, C.M., Tennent, N.H., 1994. Pollution monitoring in storage and display cabinets: carbonyl pollution in relation to artefact deterioration. In: Roy, A., Smith, P. (Eds.), IIC Preprints of the Contributions to the Ottawa Congress, 12}16 September 1994, Preventive Conservation Practice, Theory and Research, IIC, London, pp. 164}170.
  19. Gysels, K., Deutsch, F., Van Grieken, R., Camu!o, D., Bernardi, A., Sturaro, G., Busse, H.J., Wieser, M., 2001. Characterisa- tion of the indoor environment of the Royal Museum of Fine Arts, Antwerp, Belgium. Atmospheric Environment, submit- ted. Hargaves, K.J., Atkins, D.H.F., Bennett, S.L., 1991. The measurement of sulphur dioxide in the outdoor environment using passive di!usion tube samplers: a "rst report. AERE R12569.
  20. Osterhout, G.J., Shull, V.H., Dick, J.D., 1991. Identi"cation of clinical isolates of Gram-negative nonfermentative bacteria by an automated cellular fatty acid identi"cation system. Journal of Clinical Microbiology 29, 1822}1830.
  21. Mecklenburg, M.F., Tumosa, C.S., 2000. Temperature and rela- tive humidity e!ects on the mechanical and chemical stabil- ity of collections. ASHRAE Journal April (4), 77}82.
  22. Nazaro!, W.W., Ligocki, M.P., Salmon, L.G., Cass, G.R., Fall, T., Jones, M.C., Liu, H.I.H., Ma, T., 1993. Airborne Particles in Museums, Research in Conservation 6. Getty Conserva- tion Institute, Los Angeles.
  23. Odlyha, M., Boon, J.J., van der Brink, O., Bacci, M., 1997a. Project EV5VCT94-0548 ERA: Environmental research for art conservation. European Cultural Heritage Newsletter on Research 10, 67}77.
  24. Odlyha, M., Boon, J.J., van der Brink, O., Bacci, M., 1997b. Environmental research for art conservation (ERA). Journal of Thermal Analysis 49 (3), 1571}1584.
  25. Park, S.C., 1999. HVAC for historic buildings. ASHRAE Jour- nal April (4), 91}98.
  26. Rainey, F.A., Dorsch, M., Morgan, H.W., Stackebrandt, E., 1992. 16S rDNA analysis of Spirocheata thermophila: its phylogenetic position and implication for the systematics of the Order Spirochaetales. Systematics Applications in Microbiology 15, 197}201.
  27. Shooter, D., 1993. Nitrogen dioxide and its determination in the atmosphere. Journal of Chemical Education 70 (5), A133}A140.
  28. Sierra, G., 1957. A simple method for the detection of lipolytic activity of microorganisms and some observations on the in#uence of the contact between cells and substrates. Anto- nie van Leeuwenhoek Journal of Microbiological Serology 23, 15}22.
  29. Thomson, G., 1986. The Museum Environment 2nd Edition.. Butterworths, London.
  30. Whitmore, P.M., Cass, G.R., 1989. The fading of artists' colora- nts by exposure to atmospheric nitrogen dioxide. Studies in Conservation 34, 85}97.
  31. Yoon, Y.H., Brimblecombe, P., 2000. Contribution of dust at #oor level to particle deposit within the Sainsbury Centre for Visual Arts. Studies in Conservation 45 (2), 127}137.