Mid- infrared uncooled sensor for the identification of pure fuel, additives and adulterants in gasoline (original) (raw)

Identifying constituents in commercial gasoline using Fourier transform-infrared spectroscopy and independent component analysis

Analytica Chimica Acta, 2006

A new method is proposed that enables the identification of five refinery fractions present in commercial gasoline mixtures using infrared spectroscopic analysis. The data analysis and interpretation was carried out based on independent component analysis (ICA) and spectral similarity techniques. The FT-IR spectra of the gasoline constituents were determined using the ICA method, exclusively based on the spectra of their mixtures as a blind separation procedure, i.e. assuming unknown the spectra of the constituents. The identity of the constituents was subsequently determined using similarity measures commonly employed in spectra library searches against the spectra of the constituent components. The high correlation scores that were obtained in the identification of the constituents indicates that the developed method can be employed as a rapid and effective tool in quality control, fingerprinting or forensic applications, where gasoline constituents are suspected.

Multivariate calibration in Fourier transform infrared spectrometry as a tool to detect adulterations in Brazilian gasoline

Fuel, 2008

In the present work, Fourier transform infrared spectroscopy (FTIR) in association with multivariate chemometrics classification techniques was employed to identify gasoline samples adulterated with diesel oil, kerosene, turpentine spirit or thinner. Results indicated that partial least squares (PLS) models based on infrared spectra were proven suitable as practical analytical methods for predicting adulterant content in gasoline in the volume fraction range from 0% to 50%. The results obtained by PLS provided prediction errors lower than 2% (v/v) for all adulterant determined. Additionally, Soft Independent Modeling of Class Analogy (SIMCA) was performed using all spectral data (650-3700 cm À1) for sample classification into adulterant classes defined by training set and the results indicated that undoubted adulteration detection was possible but identification of the adulterant was subject to misclassification errors, specially for kerosene and turpentine adulterated samples, and must be carefully examined. Quality control and police laboratories for gasoline analysis should employ the proposed methods for rapid screening analysis for qualitative monitoring purposes.

Determination of detergent and dispensant additives in gasoline by ring-oven and near infrared hypespectral imaging

Analytica Chimica Acta, 2014

A method using the ring-oven technique for pre-concentration in filter paper discs and near infrared hyperspectral imaging is proposed to identify four detergent and dispersant additives, and to determine their concentration in gasoline. Different approaches were used to select the best image data processing in order to gather the relevant spectral information. This was attained by selecting the pixels of the region of interest (ROI), using a pre-calculated threshold value of the PCA scores arranged as histograms, to select the spectra set; summing up the selected spectra to achieve representativeness; and compensating for the superimposed filter paper spectral information, also supported by scores histograms for each individual sample. The best classification model was achieved using linear discriminant analysis and genetic algorithm (LDA/GA), whose correct classification rate in the external validation set was 92%. Previous classification of the type of additive present in the gasoline is necessary to define the PLS model required for its quantitative determination. Considering that two of the additives studied present high spectral similarity, a PLS regression model was constructed to predict their content in gasoline, while two additional models were used for the remaining additives. The results for the external validation of these regression models showed a mean percentage error of prediction varying from 5 to 15%.

Near-Infrared Spectroscopy Coupled with Multivariate Methods for the Characterization of Ethanol Adulteration in Premium 91 Gasoline

Energy & Fuels, 2017

Ethanol, due to its high octane rating of 108, is often added as adulterant to premium 91 gasoline fuels to boost up their octane ratings to 96 or more but it does not provide the same power to engine as that of super-premium 96 gasoline fuels. In this study, a sensitive near infrared spectroscopy (NIRS) coupled with chemometrics was proposed for analysis of ethanol content in Premium 91 gasoline fuels. Standard samples of Premium 91 octane gasoline were collected from Oman's national refining and Petrochemicals Company commonly known as ORPIC. The Premium 91 samples were then intentionally spiked with ethanol at various levels. The nearinfrared spectroscopy was employed in the absorption mode to obtain the spectra of all samples scanning from 700 to 2500 nm. Then, partial least-squares (PLS) regression, partial least-squares discriminant analysis (PLS-DA) and principal component analysis (PCA), and were applied to model and interpret the near-infrared spectra. A PLS-DA model was developed to discriminate between the pristine gasoline samples and those intentionally mixed with ethanol, with excellent results (R 2 = 98% and RMSE = 0.049) by random cross validation. A PLS regression model was established to determine the ethanol content in Premium 91 gasoline samples, with values of R 2 = 99% and RMSECV = 1.88 and R 2 = 99% and RMSEP = 1.58 for cross-validation and test-set validation results, respectively. This newly developed method, is simple, rapid, and can quantify less than 2 % of ethanol adulteration in premium 91 gasolines.

Discrimination and Quantification of Moroccan Gasoline Adulteration with Diesel Using Fourier Transform Infrared Spectroscopy and Chemometric Tools

Journal of AOAC INTERNATIONAL, 2019

In this work, transform-infrared spectroscopy (FTIR) was associated with chemometric tools, especially principal component analysis (PCA) and partial least squares regression (PLSR), to discriminate and quantify gasoline adulteration with diesel. The method is composed of a total of 100 mixtures were prepared, and then FTIR fingerprints were recorded for all samples. PCA was used to verify that mixtures can be distinguished from pure products and to check that there are no outliers. As a result of using just PC1 and PC2, more than 98% of the general variability was explained. The PLSR model based on infrared spectra has shown its capabilities to be suitable for predicting gasoline adulteration in the concentration range of 0 to 98% (w/w), with a high significant coefficient of determination (R2 = 99.25%) and an acceptable calibration and prediction errors (root mean squared error of calibration = 0.63 and root mean square of external validation and/or prediction = 0.69).

Fast Detection of Adulterants/Contaminants in Biodiesel/Diesel Blend (B5) Employing Mid-Infrared Spectroscopy and PLS-DA

Energy & Fuels, 2015

This work presents the potentiality of partial least squares discriminant analysis (PLS-DA) associated with midinfrared spectroscopy to detect gasoline, residual automotive lubricant oil, soybean oil, and used frying oil, in biodiesel/diesel blend (B5). The samples of biodiesel/diesel blend unadulterated and adulterated were classified correctly in their respective groups; that is, the PLS-DA models showed 100% correct classification in samples of the test set with high levels of sensitivity and specificity to discriminate between adulterated and unadulterated samples. These results indicate that the methodology proposed is a viable alternative to detect these types of adulterants/contaminants in biodiesel/diesel blend (B5), commonly used in Brazil.

Gasoline classification using near infrared (NIR) spectroscopy data: Comparison of multivariate techniques

Analytica Chimica Acta, 2010

Near infrared (NIR) spectroscopy is a non-destructive (vibrational spectroscopy based) measurement technique for many multicomponent chemical systems, including products of petroleum (crude oil) refining and petrochemicals, food products (tea, fruits, e.g., apples, milk, wine, spirits, meat, bread, cheese, etc.), pharmaceuticals (drugs, tablets, bioreactor monitoring, etc.), and combustion products. In this paper we have compared the abilities of nine different multivariate classification methods: linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), regularized discriminant analysis (RDA), soft independent modeling of class analogy (SIMCA), partial least squares (PLS) classification, K-nearest neighbor (KNN), support vector machines (SVM), probabilistic neural network (PNN), and multilayer perceptron (ANN-MLP)-for gasoline classification. Three sets of near infrared (NIR) spectra (450, 415, and 345 spectra) were used for classification of gasolines into 3, 6, and 3 classes, respectively, according to their source (refinery or process) and type. The 14,000-8000 cm −1 NIR spectral region was chosen. In all cases NIR spectroscopy was found to be effective for gasoline classification purposes, when compared with nuclear magnetic resonance (NMR) spectroscopy or gas chromatography (GC). KNN, SVM, and PNN techniques for classification were found to be among the most effective ones. Artificial neural network (ANN-MLP) approach based on principal component analysis (PCA), which was believed to be efficient, has shown much worse results. We hope that the results obtained in this study will help both further chemometric (multivariate data analysis) investigations and investigations in the sphere of applied vibrational (infrared/IR, near-IR, and Raman) spectroscopy of sophisticated multicomponent systems.

Classification of Brazilian and foreign gasolines adulterated with alcohol using infrared spectroscopy

Forensic Science International, 2015

The smuggling of products across the border regions of many countries is a practice to be fought. Brazilian authorities are increasingly worried about the illicit trade of fuels along the frontiers of the country. In order to confirm this as a crime, the Federal Police must have a means of identifying the origin of the fuel. This work describes the development of a rapid and nondestructive methodology to classify gasoline as to its origin (Brazil, Venezuela and Peru), using infrared spectroscopy and multivariate classification. Partial Least Squares Discriminant Analysis (PLS-DA) and Soft Independent Modeling Class Analogy (SIMCA) models were built. Direct standardization (DS) was employed aiming to standardize the spectra obtained in different laboratories of the border units of the Federal Police. Two approaches were considered in this work: (1) local and (2) global classification models. When using Approach 1, the PLS-DA achieved 100% correct classification, and the deviation of the predicted values for the secondary instrument considerably decreased after performing DS. In this case, SIMCA models were not efficient in the classification, even after standardization. Using a global model (Approach 2), both PLS-DA and SIMCA techniques were effective after performing DS. Considering that real situations may involve questioned samples from other nations (such as Peru), the SIMCA method developed according to Approach 2 is a more adequate, since the sample will be classified neither as Brazil nor Venezuelan. This methodology could be applied to other forensic problems involving the chemical classification of a product, provided that a specific modeling is performed. ß

A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers

Analytica Chimica Acta, 2008

This work presents a comparative study of calibration transfer among three near infrared spectrometers for determination of naphthenes and RON (Research Octane Number) in gasoline. Seven transfer methods are compared: direct standardization (DS), piecewise direct standardization (PDS), orthogonal signal correction (OSC), reverse standardization (RS), piecewise reverse standardization (PRS), slope and bias correction (SBC) and model updating (MU). Two pre-treatment procedures, namely standard normal variate (SNV) and multiplicative scatter correction (MSC), are also investigated. The choice of an appropriate number of transfer samples for each technique, as well as the effect of window size in PDS/PRS and OSC components, are discussed. A broad set of gasoline samples representative of the Northeastern states of Brazil is employed in the investigation. The results show that the use of calibration transfer yields prediction errors comparable to those obtained with complete recalibration of the secondary instrument. Overall, the results point to RS as the best method for the analytical problem under consideration. When storage and/or physical transportation of transfer samples are impractical, MU is more appropriate. The comprehensive investigation carried out in the present work will be of value for practitioners involved in networks of fuel monitoring.