A protein-based biointerfacing route toward label-free immunoassays with long period gratings in transition mode (original) (raw)
Related papers
Highly sensitive label-free antibody detection using a long period fibre grating sensor
Sensors and Actuators B: Chemical, 2018
An optical fibre long period grating (LPG) biosensor is appealing in the detection of biomolecules because of the high sensitivity, label-free and real-time measurement. The miniaturized size, ability of remote sensing and immunity to electromagnetic interference of the LPG biosensor provide various possibility of single-point sensing in situations such as point of care diagnostics and in vivo measurement. Two optical fibre LPG based biosensors are reported for detection of streptavidin (SV) and immunoglobulin M (IgM) respectively. The LPG is coated with a film containing three layers of Poly(allylamine hydrochloride)/gold coated silica nanoparticles via the layerby-layer method. Biotin is covalently bonded to the surface of the gold shell by means of the formation of an amide bonds for detection of streptavidin. The concentration of SV in water for detection varied from 1.25 nM to 2.7 μM. The LPG sensor, operating close to the phase matching condition shows a high sensitivity of 3.88 (ng/ mm 2) −1 and a detection limit of 0.86 pg/mm 2 for the detection of SV. The limit of detection is 22 times lower than previously demonstrated with this type of sensor. The developed IgM sensor has the same configuration of film but has anti-IgM embedded on the LPG instead of biotin, demonstrating versatility of the sensing platform. This was used for the detection of human IgM with concentrations from 15.6 μg/ml to 1 mg/ml. The LPG sensor exhibits a sensitivity of 11 nm (ng/mm 2) −1 for the detection of IgM with a detection limit of 15 pg/mm 2. The developed highly sensitive IgM sensor shows the potential application of clinical point of care for detection of lower concentration of IgM in vitro. The proposed biosensor exhibits high sensitivity and rapid detection of low concentrations biomolecules from the small size of SV to the large size of IgM.
Biosensors and Bioelectronics, 2009
Traditionally, the integration of sensing gel layers in Surface Plasmon Resonance (SPR) is achieved via "bulk" methods, such as precipitation, spin-coating or in-situ polymerization onto the total surface of the sensor chip, combined with covalent attachment of the antibody or receptor to the gel surface. This is wasteful in terms of materials as the sensing only occurs at the point of resonance interrogated by the laser. By isolating the sensing materials (antibodies, enzymes, aptamers, polymers, MIPs etc.) to this exact spot a more efficient use of these recognition elements will be achieved. Here we present a method for the in-situ formation of polymers, using the energy of the evanescent wave field on the surface of an SPR device, specifically localized at the point of interrogation. Using the photo-initiator couple of methylene blue (sensitizing dye) and sodium p-toluenesulfinate (reducing agent) we polymerized a mixture of N,N-methylene-bis-acrylamide and methacrylic acid in water at the focal point of SPR. No polymerization was seen in solution or at any other sites on the sensor surface. Varying parameters such as monomer concentration and exposure time allowed precise control over the polymer thickness (from 20 -200 nm). Standard coupling with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide
Biosensors
A methodology to enhance the sensitivity of long-period fiber gratings (LPFGs) based on the combination of three different enhancement approaches is presented; the methods here adopted are the working near mode transition (MT) of a cladding mode (CM), working near the turn-around point of a CM and the enhancement of the evanescent field of CMs by reducing the cladding diameter or by increasing the order number of CMs. In order to combine these enhancement methodologies, an electrostatic self-assembly (ESA) process was used to deposit a polymeric overlay, with a chosen thickness, onto the etched fiber. The add-layer sensitivity of the sensor was theoretically calculated, and the demonstration of the real applicability of the developed LPFG as a biosensor was performed by means of an IgG/anti-IgG immunoassay in human serum in a thermostated microfluidic system. The limits of detection (LODs) calculated by following different procedures (three times the standard deviation of the blank ...
Long-period gratings in photonic crystal fiber as an optofluidic label-free biosensor
Biosensors & Bioelectronics
Using long-period gratings (LPG) inscribed in photonic crystal fiber (PCF) and coupling this structure with an optically aligned flow cell, we have developed an optofluidic refractive index transduction platform for label-free biosensing. The LPG-PCF scheme possesses extremely high sensitivity to the change in refractive index induced by localized binding event in different solution media. A model immunoassay experiment was carried out inside the air channels of PCF by a series of surface modification steps in sequence that include adsorption of poly(allylamine hydrochloride) monolayer, immobilization of anti-rat bone sialoprotein monoclonal primary antibody, and binding interactions with non-specific goat anti-rabbit IgG (H+L) and specific secondary goat anti-mouse IgG (H+L) antibodies. These adsorption and binding events were monitored in situ using the LPG-PCF by measuring the shift of the core-to-cladding mode coupling resonance wavelength. Steady and significant resonance chang...
Immunosensing with photo-immobilized immunoreagents on planar optical wave guides
Biosensors and Bioelectronics, 1995
Immunocomplexation at wave guiding TiO2/SiO 2 surfaces was investigated using an integrated optical grating coupler. For extended application of this label-free monitoring system, F(ab')2 fragments of monoclonal antibodies were photo-immobilized by photolinker polymer-mediated procedures that do not require functionalization of either the immunoreagent or the TiO2/SiO2 surface. Covalent, light-dependent binding of photolinker polymer and F(ab')2 fragments was achieved using a single-step photo-reaction. Bovine serum albumin derivatized with aryldiazirines (T-BSA) served as a photolinker polymer. T-BSA suppressed the non-specific adsorption of analytes to wave guide surfaces. Immunoreagent binding and immunological activity were analyzed and modified surfaces were investigated by scanning force microscopy. Apparent immunoreagent surface densities were 16.7 fmol F(ab')2 per mm 2 sensor surface. Optical analyses revealed linear, dose-dependent antigen binding with label free analytes. Immunocompetent surfaces were regenerable by treatment at pH 2.3, rendering the immunosensing system applicable for repetitive use.
2007
Ionic self-assembled multilayers (ISAMs) adsorbed on long period fiber gratings (LPGs) can serve as an inexpensive, robust, portable, biosensor platform. The ISAM technique is a layer-by-layer deposition technique that creates thin films on the nanoscale level. The combination of ISAMs with LPGs yields exceptional sensitivity of the optical fiber transmission spectrum. We have shown theoretically that the resonant wavelength shift for a thin-film coated LPG can be caused by the variation of the film's refractive index and/or the ...