Abstract

Currently, there are three remote automated eddy current inspection systems supplied in Ukraine under international cooperation agreements for examination of steam generators, collectors and steam generator tubing. Since 1966 the field experience in using eddy current testing (ET) for in-service inspection of VVER designed steam generators in Ukraine has shown several advantages over the previous inspection methodology which was an air bubble leakage technique. However, the field experience in using eddy current inspection technology has also shown that inspections are not always reliable. Some nuclear power plants have experienced unplanned shutdowns due to leaks in steam generator tubes, some of which were tested by ET prior to the leak. Therefore, eddy current inspection has shown significant improvement over previous testing techniques, field experience also shows the necessity to improve the ET inspection reliability as applied at Ukraine nuclear power plants. This paper presen...