Robotically assisted laparoscopic repair of anterior vaginal wall and uterine prolapse by lateral suspension with mesh: initial experience and video (original) (raw)

Modified laparoscopic lateral suspension with a five-arm mesh in pelvic organ prolapse surgery

BMC Women's Health

Background Laparoscopic lateral suspension (LLS) is a laparoscopic technique used to treat pelvic organ prolapse (POP) in apical and anterior compartment defect with the use of a synthetic T-shaped mesh graft. The posterior compartment is repaired using a second mesh or a procedure along with LLS, such as posterior colporrhaphy. The aim of this study was to evaluate the clinical results of LLS for POP using a five-arm mesh instead of a T-shaped mesh graft to repair the defect of the posterior compartment in addition to the apical and anterior compartments. Methods Data from 37 patients with a diagnosis of advanced-stage (≥ 3) POP undergoing LLS with the use of a five-arm mesh were retrospectively analysed. Pre-operative and post-operative examinations and, surgical outcomes were determined. The results of measurements and examinations, reoperation rates, erosion rates, lower urinary tract symptoms, and complications were analysed. The Prolapse Quality of Life Questionnaire (P-QOL) w...

Correction of pelvic organ prolapse by laparoscopic lateral suspension with mesh: a clinical series

European Journal of Obstetrics & Gynecology and Reproductive Biology, 2019

Objective. Illustrating the outcomes of laparoscopic lateral suspension by mesh for pelvic organ prolapse repair. Study design. A retrospective observational study was conducted collecting medical records of 48 patients treated between May 2016 and April 2018 in two different centers in Italy. Pre-and post-operative clinical evaluations as well as patients' satisfaction scores were considered. Patients were followed for two years. Statistical analysis was determined using the chi-square test in intention-to-treat and per-protocol analyses, while Kaplan-Meier curves were built for assessing the prolapse recurrence and the symptoms recurrence. The Steel-Dwass test for pairwise comparisons was used to compare median scores from the King's General Health Perception Questionnaire answers. Results. Regarding the anatomical result, the outcome was either optimal or satisfactory (PoP-Q ≤ 1) at 12 months in 92% of patients for anterior compartment, in 100% for apical compartment, and in 75% for posterior compartment (intention-to-treat). Kaplan-Meier curves depicted a repair of prolapse in 70% of cases, with better outcomes for the anterior and the apical compartment. Patient self-perception of health was over 80% at each follow-up evaluation. Conclusion. Laparoscopic lateral suspension is a reasonable technique for treatment of pelvic organ prolapse. Further studies are needed to prove such a technique versus alternative surgeries.

Mini-Laparoscopic Repair of Apical Pelvic Organ Prolapse (POP) by Lateral Suspension with Mesh

Facts, Views & Vision in ObGyn, 2018

Background The aim of the present study is to analyze the feasibility, safety and learning curve of Mini- Laparoscopic Lateral suspension (LLS) for the treatment of apical and anterior defects following pelvic organ prolapse. Methods This is a cohort study on a retrospective series of 35 consecutive patients who underwent Mini-LLS for symptomatic POP between January 2014 and July 2016. All 35 patients were operated at the Gynaecological Unit in S. Chiara Hospital by two senior surgeons (S. Tateo and L. Mereu) and by a team with optimal skills in laparoscopic surgery. Patients were divided in two groups according to two different chronological phases: phase 1 identified the initial 12 cases, phase 2 the last 23 cases. We collected pre-, peri- and post-operative information to analyze the surgical outcomes and learning curve after Mini-LLS procedures. Results The mean LLS-Overall Time (OT) was 107.6 min (range, 185- 63 min). None of the patients had intra-operative complications. No c...

Laparoscopic repair of vaginal vault prolapse by lateral suspension with mesh

Archives of Gynecology and Obstetrics, 2012

Background To evaluate the long-term outcomes of laparoscopic lateral suspension using mesh reinforcement for symptomatic posthysterectomy vaginal vault prolapse. Materials and methods We analyzed in a prospective cohort study all the women treated by laparoscopic lateral suspension with mesh for symptomatic vaginal vault prolapse between January 2004 and September 2010. In this procedure, the mesh is laterally suspended to the abdominal wall, posterior to the anterior superior iliac spine. We performed systematic follow-up examinations at 4 weeks, 6 months and yearly postoperatively. Clinical evaluation of pelvic organ support was assessed by the pelvic organ prolapse quantification (POP-Q) grading system. Main outcome measures were recurrence rate, reoperation rate for symptomatic recurrence or de novo prolapse, mesh erosion rate, reoperation rate for mesh erosion, total reoperation rate. Observations and results Of the 73 patients seen at a mean 17.5 months follow-up, recurrent vaginal vault prolapse was registered in only one woman (success rate of 98.6 %). When considering all vaginal sites, we observed a total of 13 patients with recurrent or de novo prolapse (17.8 %). The non-previously treated posterior compartment was involved in eight cases (new appearance rate of 11 %). Of these 13 women, only 6 were symptomatic, requiring surgical management (reoperation rate for genital prolapse of 8.2 %). Four patients presented with mesh erosion into the vagina (5.5 %). Two required partial vaginal excision of the mesh in the operating room (2.7 %). There were no mesh-related infections. The total reoperation rate was 11 %. Conclusion Laparoscopic lateral suspension with mesh interposition is a safe and effective technique for the treatment of vaginal vault prolapse. This approach represents an alternative procedure to the laparoscopic sacrocolpopexy.

Robot-assisted laparoscopic pectouteropexy: an alternative uterus-sparing technique for pelvic organ prolapse surgery

International Urogynecology Journal, 2017

The aim of this video is to demonstrate the alternative technique of robot-assisted laparoscopic pectouteropexy for uterus preservation in obese patients with pelvic organ prolapse. We present the case report of a 44-year-old patient with apical pelvic organ prolapse. A pelvic examination was performed during a Valsalva maneuver in the dorsal lithotomy position and in the standing position, and the patient was diagnosed with stage III apical prolapse in accordance with the Pelvic Organ Prolapse Quantification system of the International Continence Society (POP-Q: Аа −1, Ва 0, Вр 0, С +2). We performed the procedure, which was developed as an alternative to sacrocolpopexy or sacrouteropexy, as described by Banerjee and Noé (Arch Gynecol Obstet 284:24-28, 2011). Pectouteropexy is a new method for prolapse surgery that uses the lateral parts of the iliopectineal ligament for bilateral mesh fixation of the descended structures and provides strong apical support. We believe that robot-assisted laparoscopic pectouteropexy is a valuable alternative approach for uterus-preserving pelvic organ prolapse surgery owing to its better robot maneuverability, reduced operating time, and better visualization in obese patients.

One-year functional and anatomic outcomes of robotic sacrocolpopexy versus vaginal extraperitoneal colpopexy with mesh

Female pelvic medicine & reconstructive surgery

This study aimed to evaluate and compare 1-year anatomic and functional outcomes in patients undergoing transvaginal versus transabdominal repair of pelvic organ prolapse (POP) with synthetic mesh reinforcement. We conducted a retrospective, matched cohort study of patients undergoing robotic-assisted laparoscopic sacrocolpopexy (RALSC) and vaginal extraperitoneal colpopexy (VEC) with synthetic mesh from December 2008 to March 2011. We compared the preoperative to postoperative changes in anatomic, quality of life, and functional outcomes between groups after 1 year of follow-up. One-year surgical satisfaction was also assessed. Thirty-eight RALSC patients met the inclusion criteria and were matched by age and month of surgery to 38 VEC patients. Of those, 31 RALSC and 30 VEC patients (80%) had complete 1-year data. Preoperative to postoperative outcomes were similar in both groups with similar improvement seen in anatomic Pelvic Organ Prolapse Quantification measures as well as fun...