An Array of On-Chip Integrated, Individually Addressable Capacitive Field-Effect Sensors with Control Gate: Design and Modelling (original) (raw)
Related papers
CMOS based capacitive sensor laboratory-on-chip: a multidisciplinary approach
Analog Integrated Circuits and Signal Processing, 2009
In this paper, we review the recent advances of CMOS-based capacitive sensors for Lab-on-chip (LoC) applications. LoC design is a multidisciplinary approach of adapting classical biochemical assays to a miniaturized platform by exploiting advances in microelectronic and microfluidic technologies. By offering low cost and integrated devices, CMOS based LoCs could be amenable to a large number of biological and biochemical assays for disease diagnostics and biotechnology in the near future. While an exhaustive, all-encompassing review of CMOSbased LoCs is beyond the scope of this review, we have focused on the design and implementation of CMOS-based capacitive sensor LoCs for the most important biochemical applications. For each application, the corresponding biochemical sensing layer, interface circuit and microfluidic packaging technique are discussed based on the recent literature studies.
Integrated microelectronic capacitive readout subsystem for lab-on-a-chip applications
A mixed-signal capacitive biosensor readout system is presented with its main readout functionality embedded in an integrated circuit, compatible with complementary metal oxide semiconductor-type biosensors. The system modularity allows its usage as a consumable since it eventually leads to a system-on-chip where sensor and readout circuitry are hosted on the same die. In this work, a constant current source is used for measuring the input capacitance. Compared to most capacitive biosensor readout circuits, this method offers the convenience of adjusting both the range and the resolution, depending on the requirements dictated by the application. The chip consumes less than 5 mW of power and the die area is 0.06 mm2. It shows a broad input capacitance range (capable of measuring bio-capacitances from 6 pF to 9.8 nF), configurable resolution (down to 1 fF), robustness to various biological experiments and good linearity. The integrated nature of the readout system is proven to be sufficient both for one-time in situ (consumable-type) bio-measurements and its incorporation into a point-of-care system.
Single chip interdigitated electrode capacitive chemical sensor arrays
In this paper the design considerations, fabrication and first evaluation results of a capacitive type single chip chemical sensor array based on interdigitated electrode structure is presented. The electrode arrays have been fabricated with conventional semiconductor processes. The final structure consists of four interdigital capacitive sensors each one coated with a different polymer sensitive film by using only successive lithographic steps. The array sensors have good response to controlled concentrations of volatile organic compounds (∼35fF, ∼7fF, ∼12fF for the PHEMA covered sensor when exposed to 100 ppm of water, methanol and ethanol vapors and ∼2.5fF, in the case of 100 ppm of toluene vapors for the PDMS covered sensor).
An array of field-effect nanoplate SOI capacitors for (bio-)chemical sensing
Biosensors and Bioelectronics, 2011
Silicon-on-insulator (SOI) Field-effect Nanoplate capacitive sensor array Penicillin biosensor Polyelectrolyte DNA a b s t r a c t An array of individually addressable nanoplate field-effect capacitive (bio-)chemical sensors based on an SOI (silicon-on-insulator) structure has been developed. The isolation of the individual capacitors was achieved by forming a trench in the top Si layer with a thickness of 350 nm. The realized sensor array allows addressable biasing and electrical readout of multiple nanoplate EISOI (electrolyte-insulator-silicon-on-insulator) capacitive biosensors on the same SOI chip as well as differential-mode measurements. The feasibility of the proposed approach has been demonstrated by realizing sensors for the pH and penicillin concentration detection as well as for the label-free electrical monitoring of polyelectrolyte multilayers formation and DNA (deoxyribonucleic acid)-hybridization event. A potential change of ∼120 mV has been registered after the DNA hybridization for the sensor immobilized with perfectly matched single-strand DNA, while practically no signal changes have been observed for a sensor with fully mismatched DNA. The realized examples demonstrate the potential of the nanoplate SOI capacitors as a new basic structural element for the development of different types of field-effect biosensors.
The modelling of a capacitive microsensor for biosensing applications
Sensors, MEMS and Electro-Optical Systems, 2014
Microsensing is a leading field in technology due to its wide application potential, not only in bio-engineering, but in other fields as well. Microsensors have potentially low-cost manufacturing processes, while a single device type can have various uses, and this consequently helps with the ever-growing need to provide better health conditions in rural parts of the world. Capacitive biosensors detect a change in permittivity (or dielectric constant) of a biological material, usually within a parallel plate capacitor structure which is often implemented with integrated electrodes of an inert metal such as gold or platinum on a microfluidic substrate typically with high dielectric constant. There exist parasitic capacitance components in these capacitive sensors, which have large influence on the capacitive measurement. Therefore, they should be considered for the development of sensitive and accurate sensing devices. An analytical model of a capacitive sensor device is discussed, which accounts for these parasitic factors. The model is validated with a laboratory device of fixed geometry, consisting of two parallel gold electrodes on an alumina (Al 2 O 3) substrate mounted on a glass microscope slide, and with a windowed cover layer of poly-dimethyl-siloxane (PDMS). The thickness of the gold layer is 1µm and the electrode spacing is 300µm. The alumina substrate has a thickness of 200µm, and the high relative permittivity of 11.5 is expected to be a significantly contributing factor to the total device capacitance. The 155µm thick PDMS layer is also expected to contribute substantially to the total device capacitance since the relative permittivity for PDMS is 2.7. The wideband impedance analyser evaluation of the laboratory device gives a measurement result of 2pF, which coincides with the model results; while the handheld RLC meter readout of 4pF at a frequency of 10kHz is acceptable within the measurement accuracy of the instrument. This validated model will now be used for the geometric design and simulation of efficient capacitive sensors in specific biological detection applications.
Nanoplate field-effect capacitive (bio-)chemical sensor array based on SOI structure
Procedia Chemistry, 2009
An array of individually addressable nanoplate field-effect capacitive (bio-)chemical sensors based on an SOI (silicon-oninsulator) structure has been developed for multi-parameter detection. An isolation of the individual capacitors was achieved by forming a trench in the top Si layer with various thicknesses of 30-350 nm. The feasibility of the proposed approach has been demonstrated by realising sensors for the detection of pH as well as for the label-free electrical monitoring of adsorption and binding of charged macromolecules.
A Reconfigurable Multichannel Capacitive Sensor Array Interface
IEEE Transactions on Instrumentation and Measurement, 2000
The design of a reconfigurable capacitive sensor array interface comprised of a subsystem able to read an array of capacitive-type sensors and an embedded processor is described. Each sensor is connected to a ring oscillator, which translates capacitive changes into a variable-frequency pulse train. An indepth analysis of the oscillator behavior including all parasitic elements has been performed, and the use of a Schmitt trigger at the inverter chain is proposed to assure oscillation for capacitance values ranging from 1 to 1500 pF. The oscillation frequency is estimated by using a 16-b counter and the appropriate userdefined counting interval ranging from a few microseconds to several seconds in order to achieve maximum accuracy within the entire capacitance range. The 2-B word thus produced can be sent to a host computer through a serial or parallel interface for further processing. To demonstrate the concept, a 16-channel interface has been described in a hardware description language and implemented on a complex programmable logic device. Measurement of two different capacitive pressure sensors developed in-house reveals frequency sensitivity values of −252.1 and −9.54 Hz/fF, which are in good agreement with the expected values derived by the analytic relations.
Biosensors and Bioelectronics, 2009
A simplified measurement scheme and device structure aiming at developing a low cost, label-free, pointof-care capacitive biosensor were investigated. The detection principle is the increase of low frequency capacitance between two planar Al electrodes observed after antibody-antigen interaction. The electrodes, deposited on oxidized Si wafers, were covered with an antibody layer, with and without using self-assembled thiol monolayer. Immunoglobulin G (IgG) and cardiac troponin T (TnT) were used as analytes to asses this proposal. The device was able to detect successfully TnT levels in the range 0.07 to 6.83 ng/mL in human serum from patients with cardiac diseases and in the range 0.01 ng/mL to 5 ng/mL for TnT in phosphate buffer saline. An equivalent circuit model able to reproduce the general behavior of experimental capacitance versus frequency curves was presented. The investigated features that have potential to reduce costs and simplify measurements were: use of single, low frequency (1 kHz) measurement signal, within the range of low cost portable capacitance meters; employment of a lower cost electrode material, aluminum, instead of gold electrodes; and use of simple and miniaturized planar two-electrodes arrangement, thus making a portable system for point-of-care applications.