Secondary beam fragments produced by 200 MeV u −1 12 C ions in water and their dose contributions in carbon ion radiotherapy (original) (raw)
2008, New Journal of Physics
For applications in heavy-ion radiotherapy, the emission of secondary fragments from 200 MeV u −1 carbon ions was investigated using a 12.78 cm thick water absorber as a tissue-equivalent beam stopping target. Secondary light particles (n, p, d, t, 3 He and 4 He) produced by nuclear fragmentation and emerging from the target in forward direction were detected with a E − E-telescope consisting of NE102 and BaF 2 scintillation detectors. Energy spectra of the fragments at angles of 0 • , 5 • , 10 • , 20 • and 30 • to the beam axis were obtained from time-of-flight measurements. They show a broad maximum at about half of the projectiles energy per nucleon, the shape at high energies is exponential and extends up to the projectiles initial energy per nucleon-for neutrons and protons to about twice the energy of the projectile per nucleon. Comparison of the experimental data with calculations performed with the Monte-Carlo code (partide and heavy ion transport code system (PHITS)) shows fairly good agreement for neutrons, protons and deuterons, but some deviations for tritons and helium fragments. The neutron dose in patient treatments with carbon ions was estimated to be 8 mGy per treatment-Gy based on the measured neutron yield.
Sign up for access to the world's latest research
checkGet notified about relevant papers
checkSave papers to use in your research
checkJoin the discussion with peers
checkTrack your impact
Sign up for access to the world's latest research
Related papers
Experimental Investigation of Secondary Fast Neutrons Produced in Carbon Ion Radiotherapy
Proceedings of International Workshop on Fast Neutron Detectors and Applications — PoS(FNDA2006)
The radiation field of heavy-ion beams used for radiotherapy applications is significantly affected by nuclear fragmentation processes along the penetration path in tissue, causing an attenuation of the primary ion beam flux and the build-up of light fragments including fast neutrons. The emission of secondary fragments from 200 MeV/u carbon ions delivered from the synchrotron SIS-18 at GSI was investigated using a water absorber as tissue-equivalent beam stopping target. Energy spectra, angular distributions and yields of fast neutrons and charged particles emerging from the absorber downstream were investigated by using fast scintillation detectors and time-of-flight techniques. From the resulting yield of 0.54 neutrons (E n >10 MeV) per primary 12 C ion a neutron dose of 5.4 mSv per Cobalt Gray Equivalent (GyE) delivered to the target volume is estimated. Additional measurements employing a wide-energy neutron detector (WENDI-II) under identical irradiation conditions were found to be in fair agreement with the dose estimate based on the measured fast neutron fluences.
Nuclear fragmentation of high-energy heavy-ion beams in water
Advances in Space Research, 1996
As a part of the physical-tcchnica1 program of the heavy-ion therapy project at GSI WC have invcstigatcd the nuclear fragmentation of high-cncrgy ion beams dclivcrcd by the heavy-ion synchrotron SIS, using water as a tissue-cquivalcnt target. For a direct comparison of fragmcntation propcrtics, beams of l"B, t2C, 14N, and I60 wcrc produced simultaneously as sccondary hcams from a primary ' RO beam and scpamtcd in flight by magnetic beam analysis. 'l'hc %-distributions of beam fragments produced in the water target wcrc mcasurcd via cncrgy loss in a large ionisation chamber and a scintillator t&scope. I:rom thcsc data WC obtained both total and partial charge-changing cross sections. In addition WC have pcrformcd Bragg mcasurcmcnts using two parallel-plate ionization chambers and a water target of variable length. The detailed shape of the measured Bragg curves and the measured cross sections are in good agrecmcnt with model calculations based on semi-empirical formulae. IN1'KODUC'fION (2)@ D. Scbardt er al.
Measured neutron energy distributions emitted from a thick stopping target of natural carbon at 0°, 30°, 60° and 90° from nuclear reactions caused by 12 MeV/amu incident 12C5+ ions were converted to energy differential and total neutron absorbed dose as well as ambient dose equivalent H*(10) using the fluence to dose conversion coefficients provided by the ICRP. Theoretical estimates were accomplished using the Monte Carlo nuclear reaction model code PACE and a few existing empirical formulations for comparison. Results from the PACE code showed an underestimation of the high energy part of energy differential dose distributions at forward angles whereas the empirical formulation by Clapier et al approximated the energy integrated angular distribution of H*(10) satisfactorily. Using the measured data neutron doses received by some vital human organs were estimated for an anterior-posterior (AP) exposure. The estimated energy averaged quality factors were found to vary for different organs from about 7 to about 13. Emitted neutrons having energies above 20 MeV were found to contribute about 20% of the total dose at 0° while at 90° the contribution reduces to about 2%.
Microdosimetry of radiation field from a therapeutic 12C beam in water: A study with Geant4 toolkit
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2013
We model the responses of Tissue-Equivalent Proportional Counters (TEPC) to radiation fields of therapeutic 12 C beams in a water phantom and to quasimonoenergetic neutrons in a PMMA phantom. Simulations are performed with the Monte Carlo model for Heavy Ion Therapy (MCHIT) based on the Geant4 toolkit. The shapes of the calculated lineal energy spectra agree well with measurements in both cases. The influence of fragmentation reactions on the TEPC response to a narrow pencil-like beam with its width smaller than the TEPC diameter is investigated by Monte Carlo modeling. It is found that total lineal energy spectra are not very sensitive to the choice of the nuclear fragmentation model used. The calculated frequency-mean lineal energyȳ f differs from the data on the axis of a therapeutic beam by less than 10% and by 10-20% at other TEPC positions. The validation of MCHIT with neutron beams gives us confidence in estimating the contributions to lineal energy spectra due to secondary neutrons produced in water by 12 C nuclei. As found, the neutron contribution at 10 cm distance from the beam axis amounts to ∼ 50% close the entrance to the phantom and decreases to ∼ 25% at the depth of the Bragg peak and beyond it. The presented results can help in evaluating biological out-of-field doses in carbon-ion therapy.
Radiotherapy with beams of carbon ions
Reports on Progress in Physics, 2005
In cancer treatment, the introduction of MeV bremsstrahlung photons has been instrumental in delivering higher doses to deep-seated tumours, while reducing the doses absorbed by the surrounding healthy tissues. Beams of protons and carbon ions have a much more favourable dose-depth distribution than photons (called 'x-rays' by medical doctors) and are the new frontiers of cancer radiation therapy. Section 2 presents the status of the first form of hadrontherapy which uses beams of 200-250 MeV protons. The central part of this review is devoted to the discussion of the physical, radiobiological and clinical bases of the use of 400 MeV u −1 carbon ions in the treatment of radio-resistant tumours. These resist irradiation with photon as well as proton beams. The following section describes the carbon ion facilities that are either running or under construction. Finally, the projects recently approved or proposed are reviewed here.
Progress in Nuclear Science and Technology, 2011
In the heavy-ion radiotherapy, considerable discussion has been attracted regarding the potential for second cancer induction by secondary neutrons produced in primary heavy-ion fragmentation. It is needed to develop a Monte-Carlo simulation tool to estimate neutron doses and the photon contribution. Since it is notoriously hard to reproduce the spectral cross sections of neutrons and photons by simulations, we have planned experiments to measure energy-angle double-differential cross sections of nuclear reactions. Several simulation studies have been conducted to realize experiments at the synchrotron HIMAC of NIRS, Japan. Expected spectral cross sections of neutrons and photons are discussed by using Monte-Carlo simulation codes, PHITS and EGS5.
IEEE Transactions on Radiation and Plasma Medical Sciences, 2020
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumour and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene (plastic scintillator, C b Ha) allowed to measure fragments production cross sections, exploiting a Time of Flight (ToF) technique. Plastic scintillator detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 and 60 degrees with respect to the beam direction. The measured proton, deuteron and triton differential production cross sections on C, O and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.
Neutrons from fragmentation of light nuclei in tissue-like media: a study with the GEANT4 toolkit
Physics in Medicine and Biology, 2005
We study energy deposition by light nuclei in tissue-like media taking into account nuclear fragmentation reactions, in particular, production of secondary neutrons. The calculations are carried out within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit. Experimental data on depth-dose distributions for 135A-400A MeV 12 C and 18 O beams are described very well without any adjustment of the model parameters. This gives confidence in successful use of the GEANT4 toolkit for MC simulations of cancer therapy with beams of light nuclei. The energy deposition due to secondary neutrons produced by 12 C and 20 Ne beams in a (40-50 cm) 3 water phantom is estimated to 1-2% of the total dose, that is only slightly above the neutron contribution (∼1%) induced by a 200 MeV proton beam.