In vivo measurement of stent length by using intravascular ultrasound (original) (raw)
Quantitative measurements of in-stent restenosis: A comparison between quantitative coronary ultrasound and quantitative coronary angiography
Jurgen Ligthart
Catheterization and Cardiovascular Interventions, 1999
View PDFchevron_right
Comparison of Intracoronary Ultrasound Expansion Parameters in Coronary Stents Implanted With or Without Balloon Predilatation. A Randomized Intravascular Ultrasound Study
Ramón López Palop
Revista Española de Cardiología (English Edition), 2004
View PDFchevron_right
Coronary Stents : In Vitro Aspects of an Angiographic and Ultrasound Quantification With In Vivo Correlation
Simon Stertzer
Circulation, 1998
View PDFchevron_right
Intraluminal ultrasound assessment of vascular stent deployment
Rodney White
Annals of vascular surgery, 1991
View PDFchevron_right
Quantitative videodensitometric technique for verification of optimal coronary stent implantation1Supported by a research grant from Dr. Herbert J Berman foundation.1
Morris Mosseri
International Journal of Medical Informatics, 1998
View PDFchevron_right
Coronary stent implantation technique: prolonged inflation time maximizes stent expansion
Stephen Holmberg
The Journal of invasive cardiology, 2013
View PDFchevron_right
StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions
Lucio Padilla
Cardiology and Therapy, 2013
View PDFchevron_right
Relative importance of the components of stent geometry to stretch induced in-stent neointima formation
Nadine Arnold
Heart, 2005
View PDFchevron_right
Serial Angiography and Intravascular Ultrasound: Results of the SISC Registry (Stents In Small Coronaries)
Robert Whitbourn
JACC: Cardiovascular Interventions, 2010
View PDFchevron_right
The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems
Kaoru Tanaka
The International Journal of Cardiovascular Imaging, 2007
View PDFchevron_right
Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses: Final Results of a Randomized Comparison With Angiographic Guidance (TULIP Study)
Pranobe Oemrawsingh
Circulation, 2003
View PDFchevron_right
Enhanced stent imaging improves the diagnosis of stent underexpansion and optimizes stent deployment
Elias Sanidas
Catheterization and Cardiovascular Interventions, 2012
View PDFchevron_right
Three-dimensional intravascular ultrasonic volumetric quantification of stent recoil and neointimal formation of two new generation tubular stents
Pedro Antonio Otero Serrano
The American Journal of Cardiology, 2000
View PDFchevron_right
Computer-assisted quantitative evaluation of coronary stent platforms by different intracoronary imaging methods
Klaudia Proniewska
2013
View PDFchevron_right
Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses
Enno van der Velde
Circulation, 2002
View PDFchevron_right
Better stent expansion by two-time inflation of stent balloon and its responsible mechanism
Yasuki Kihara
Journal of Cardiology, 2012
View PDFchevron_right
Balloon to Artery Ratio, Not Inflation Pressure, Correlates with Adequate Stent Deployment: Size Is More Important than Pressure
OSCAR DANIEL MAQUEDA ROSALES
Journal of Interventional Cardiology, 2000
View PDFchevron_right
Quantitative Coronary Angiographic and Intravascular Ultrasound Assessment of a New Nonarticulated Stent: Report From the Advanced Cardiovascular Systems MultiLink Stent Pilot Study
Larry Dean
Journal of the American College of Cardiology, 1998
View PDFchevron_right
Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE trial
Peter Fitzgerald
Journal of The American College of Cardiology, 2001
View PDFchevron_right
Nonrandomized Comparison of Coronary Stenting Under Intravascular Ultrasound Guidance of Direct Stenting Without Predilation Versus Conventional Predilation With a Semi-Compliant Balloon Versus Predilation With a New Scoring Balloon
Yingbo Na
The American Journal of Cardiology, 2007
View PDFchevron_right
Overestimation of stent delivery balloon diameters by manufacturers' compliance tables: A quantitative coronary analysis of Duet and NIR stent implantation
Christoph Hehrlein
Catheterization and Cardiovascular Interventions, 2001
View PDFchevron_right
Intravascular ultrasound and quantitative coronary angiography assessment of late in-stent restenosis: In vivo human correlation and methodological implications
Alessandro Manzoli
New Directions for Community Colleges, 2002
View PDFchevron_right
Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes
Fermin Tio
Journal of the American College of Cardiology, 1998
View PDFchevron_right
Effect of Plaque Volume on Subsequent Vessel Remodeling at Edges of Sirolimus-Eluting Stents
Yoshio Kobayashi
The American Journal of Cardiology, 2006
View PDFchevron_right
Effect of Stent Length on Clinical Outcome in.pdf
Ranjan Modi
View PDFchevron_right
Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study
Ahmad Farshid, Bruce Shadbolt
IJC Heart & Vessels, 2014
View PDFchevron_right
Prevalence and Clinical Impact of Tissue Protrusion After Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy
Bernhard Witzenbichler
JACC. Cardiovascular interventions, 2016
View PDFchevron_right
Comparison of Quantitative Coronary Angiography, Intravascular Ultrasound, and Coronary Pressure Measurement to Assess Optimum Stent Deployment
Jacques Koolen
Circulation, 1999
View PDFchevron_right