In vivo measurement of stent length by using intravascular ultrasound (original) (raw)

Quantitative measurements of in-stent restenosis: A comparison between quantitative coronary ultrasound and quantitative coronary angiography

Jurgen Ligthart

Catheterization and Cardiovascular Interventions, 1999

View PDFchevron_right

Comparison of Intracoronary Ultrasound Expansion Parameters in Coronary Stents Implanted With or Without Balloon Predilatation. A Randomized Intravascular Ultrasound Study

Ramón López Palop

Revista Española de Cardiología (English Edition), 2004

View PDFchevron_right

Coronary Stents : In Vitro Aspects of an Angiographic and Ultrasound Quantification With In Vivo Correlation

Simon Stertzer

Circulation, 1998

View PDFchevron_right

Intraluminal ultrasound assessment of vascular stent deployment

Rodney White

Annals of vascular surgery, 1991

View PDFchevron_right

Quantitative videodensitometric technique for verification of optimal coronary stent implantation1Supported by a research grant from Dr. Herbert J Berman foundation.1

Morris Mosseri

International Journal of Medical Informatics, 1998

View PDFchevron_right

Coronary stent implantation technique: prolonged inflation time maximizes stent expansion

Stephen Holmberg

The Journal of invasive cardiology, 2013

View PDFchevron_right

StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

Lucio Padilla

Cardiology and Therapy, 2013

View PDFchevron_right

Relative importance of the components of stent geometry to stretch induced in-stent neointima formation

Nadine Arnold

Heart, 2005

View PDFchevron_right

Serial Angiography and Intravascular Ultrasound: Results of the SISC Registry (Stents In Small Coronaries)

Robert Whitbourn

JACC: Cardiovascular Interventions, 2010

View PDFchevron_right

The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems

Kaoru Tanaka

The International Journal of Cardiovascular Imaging, 2007

View PDFchevron_right

Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses: Final Results of a Randomized Comparison With Angiographic Guidance (TULIP Study)

Pranobe Oemrawsingh

Circulation, 2003

View PDFchevron_right

Enhanced stent imaging improves the diagnosis of stent underexpansion and optimizes stent deployment

Elias Sanidas

Catheterization and Cardiovascular Interventions, 2012

View PDFchevron_right

Three-dimensional intravascular ultrasonic volumetric quantification of stent recoil and neointimal formation of two new generation tubular stents

Pedro Antonio Otero Serrano

The American Journal of Cardiology, 2000

View PDFchevron_right

Computer-assisted quantitative evaluation of coronary stent platforms by different intracoronary imaging methods

Klaudia Proniewska

2013

View PDFchevron_right

Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses

Enno van der Velde

Circulation, 2002

View PDFchevron_right

Better stent expansion by two-time inflation of stent balloon and its responsible mechanism

Yasuki Kihara

Journal of Cardiology, 2012

View PDFchevron_right

Balloon to Artery Ratio, Not Inflation Pressure, Correlates with Adequate Stent Deployment: Size Is More Important than Pressure

OSCAR DANIEL MAQUEDA ROSALES

Journal of Interventional Cardiology, 2000

View PDFchevron_right

Quantitative Coronary Angiographic and Intravascular Ultrasound Assessment of a New Nonarticulated Stent: Report From the Advanced Cardiovascular Systems MultiLink Stent Pilot Study

Larry Dean

Journal of the American College of Cardiology, 1998

View PDFchevron_right

Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE trial

Peter Fitzgerald

Journal of The American College of Cardiology, 2001

View PDFchevron_right

Nonrandomized Comparison of Coronary Stenting Under Intravascular Ultrasound Guidance of Direct Stenting Without Predilation Versus Conventional Predilation With a Semi-Compliant Balloon Versus Predilation With a New Scoring Balloon

Yingbo Na

The American Journal of Cardiology, 2007

View PDFchevron_right

Overestimation of stent delivery balloon diameters by manufacturers' compliance tables: A quantitative coronary analysis of Duet and NIR stent implantation

Christoph Hehrlein

Catheterization and Cardiovascular Interventions, 2001

View PDFchevron_right

Intravascular ultrasound and quantitative coronary angiography assessment of late in-stent restenosis: In vivo human correlation and methodological implications

Alessandro Manzoli

New Directions for Community Colleges, 2002

View PDFchevron_right

Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes

Fermin Tio

Journal of the American College of Cardiology, 1998

View PDFchevron_right

Effect of Plaque Volume on Subsequent Vessel Remodeling at Edges of Sirolimus-Eluting Stents

Yoshio Kobayashi

The American Journal of Cardiology, 2006

View PDFchevron_right

Effect of Stent Length on Clinical Outcome in.pdf

Ranjan Modi

View PDFchevron_right

Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study

Ahmad Farshid, Bruce Shadbolt

IJC Heart & Vessels, 2014

View PDFchevron_right

Prevalence and Clinical Impact of Tissue Protrusion After Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy

Bernhard Witzenbichler

JACC. Cardiovascular interventions, 2016

View PDFchevron_right

Comparison of Quantitative Coronary Angiography, Intravascular Ultrasound, and Coronary Pressure Measurement to Assess Optimum Stent Deployment

Jacques Koolen

Circulation, 1999

View PDFchevron_right