Influence of Different Maintenance Times of Torque Application on the Removal Torque Values to Loosen the Prosthetic Abutment Screws of External Hexagon Implants. (original) (raw)

Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections

Altair Cury, Noéli Boscato

Revista Odonto Ciência (Online), 2010

View PDFchevron_right

Implant Abutment Screw Loosening: A Review of Effective Factors

azam mostafavi

JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019

View PDFchevron_right

Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading

Behnaz Ebadian

International Journal of Dentistry, 2021

View PDFchevron_right

Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections Avaliação do pré-aparafusamento em pilares e parafusos protéticos em diferentes conexões de implante

Altair Cury, Noéli Boscato

View PDFchevron_right

An In Vitro Analysis of Implant Screw Torque Loss With External Hex and Internal Connection Implant Systems

Allyn Luke

Implant Dentistry, 2006

View PDFchevron_right

Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study

Eduardo J V Lourenço

Clinical Oral Implants Research, 2012

View PDFchevron_right

S ABSTRACT PRELOAD AND TORQUE REMOVAL EVALUATION OF THREE DIFFERENT ABUTMENT SCREWS FOR SINGLE STANDING IMPLANT RESTORATIONS

Marco Bascialla

View PDFchevron_right

Influence of Different Implant Abutment Connection Designs on Abutment Screw Loosening in Dental Implant Systems – a Systematic Review

Shalu Mondal

International Journal of Medical and Biomedical Studies

View PDFchevron_right

Effect of Misfit on Preload Maintenance of Retention Screws of Implant-Supported Prostheses

Valentim Barão

Journal of Materials Engineering and Performance, 2009

View PDFchevron_right

Effect of Abutment Screw Design and Crown/Implant Ratio on Preload Maintenance of Single-Crown Screw-Retained Implant-Supported Prostheses

Newton Sesma

The International Journal of Oral & Maxillofacial Implants, 2019

View PDFchevron_right

Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study

Kangwon Shin

Journal of The Korean Association of Oral and Maxillofacial Surgeons, 2020

View PDFchevron_right

Guidelines for Positioning External Hexagon Implants in Screw-Retained Multiple Prostheses Using Rotational Abutment-Type Components

Waldimir Carvalho

Implant Dentistry, 2014

View PDFchevron_right

Evaluation of Torque Maintenance of Abutment and Cylinder Screws With Morse Taper Implants

Valentim Barão

Journal of Craniofacial Surgery, 2012

View PDFchevron_right

The Relationship Between Time of Retightening and Preload Loss of Abutment Screws for Two Different Implant Designs: An In Vitro Study

Antonio Scarano

Journal of Oral Implantology, 2020

View PDFchevron_right

Cyclic Loading Impact on Screw Loosening of Internally Connected Implants: An Experimental Study

mohamed fahmi

International Journal of Prosthodontics and Restorative Dentistry, 2018

View PDFchevron_right

Manual closing torque in five implant abutment systems: An in vitro comparative study

Martin Gross

The Journal of Prosthetic Dentistry, 1999

View PDFchevron_right

Effectiveness of Sealing Gel on Vertical Misfit at the Implant-Abutment Interface and Preload Maintenance of Screw-Retained Implant-Supported Prostheses

Wirley Assunção

The International Journal of Oral & Maxillofacial Implants, 2020

View PDFchevron_right

Mechanical Comparison of Experimental Conical-Head Abutment Screws with Conventional Flat-Head Abutment Screws for External-Hex and Internal Tri-Channel Implant Connections: An In Vitro Evaluation of Loosening Torque

Renata David N Rodrigues

The International Journal of Oral & Maxillofacial Implants, 2013

View PDFchevron_right

The Evaluation of Unscrewing Torque Values of Implant-Abutment Connections: An In Vitro Study

Andrea Fabianelli

The International journal of prosthodontics

View PDFchevron_right

Evaluation of the effectiveness of a technique to prevent screw loosening

Paul Binon

The Journal of Prosthetic Dentistry, 1998

View PDFchevron_right

Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system

A. Khraisat

The Journal of Prosthetic Dentistry, 2004

View PDFchevron_right

The effect of different implant-abutment connection on screw joint stability

Konstantinos Michalakis

Journal of Oral Implantology, 2012

View PDFchevron_right

Comparison of "Look-Alike" Implant Prosthetic Retaining Screws

David Gratton

Journal of Prosthodontics, 1995

View PDFchevron_right

In vitro integrity of implant external hexagon after application of surgical placement torque simulating implant locking

Flavio Neves

Brazilian Oral Research, 2008

View PDFchevron_right

Mechanical Complications Related to the Retention Screws of Prefabricated Metal Abutments With Different Angulations: A Retrospective Study With 916 Implants

Cesar Augusto Magalhães Benfatti

Implant dentistry, 2018

View PDFchevron_right

A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants

Eduardo J V Lourenço

Journal of Applied Oral Science, 2011

View PDFchevron_right

Effect of cement washout on loosening of abutment screws and vice versa in screw-and cement-retained implant-supported dental prosthesis

No Body

View PDFchevron_right