Aortic valve prosthesis-patient mismatch and long-term outcomes: 19-year single-center experience (original) (raw)

Impact of Valve Prosthesis-Patient Mismatch on Left Ventricular Mass Regression Following Aortic Valve Replacement

Giovanni Troise, Marco Cirillo

The Annals of Thoracic Surgery, 2005

View PDFchevron_right

Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients

Abid Iqbal

Indian Journal of Thoracic and Cardiovascular Surgery, 2018

View PDFchevron_right

Impact of Prosthesis-Patient Mismatch on Cardiac Events and Midterm Mortality After Aortic Valve Replacement in Patients With Pure Aortic Stenosis

Giovanni Troise, Marco Cirillo

Circulation, 2006

View PDFchevron_right

Effect of Prosthesis-Patient Mismatch on Long-Term Survival With Aortic Valve Replacement: Assessment to 15 Years

Samuel Lichtenstein

The Annals of Thoracic Surgery, 2010

View PDFchevron_right

EFFECT OF PATIENT PROSTHESIS MISMATCH ON LEFT VENTRICLAR FUNCTION AND REGRESSION AFTER AORTIC VALVE REPLACEMENT FOR AORTIC STENOSIS

Husain H Jabbad

View PDFchevron_right

Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis: Impact of Prosthesis-Patient Mismatch

Ian Burwash

Circulation, 2006

View PDFchevron_right

Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆

Ardawan Rastan, S. Lehmann

European Journal of Cardio-Thoracic Surgery, 2006

View PDFchevron_right

Impact of Patient–Prosthesis Mismatch Following Aortic Valve Replacement on Short-Term Survival: A Retrospective Single Center Analysis of 632 Consecutive Patients with Isolated Stented Biological Aortic Valve Replacement

Georg Lutter

The Thoracic and Cardiovascular Surgeon, 2014

View PDFchevron_right

Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant

George Christakis

The Annals of Thoracic Surgery, 2002

View PDFchevron_right

Does patient–prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients?

Tommaso Regesta, Giancarlo Passerone

Journal of Cardiovascular Medicine, 2015

View PDFchevron_right

Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival

Jorge Mascaro

The Annals of Thoracic Surgery, 2010

View PDFchevron_right

Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prostheses

Luca Testa

JACC: Cardiovascular Interventions, 2019

View PDFchevron_right

Long-Term Survival Following Aortic Valve Replacement: the Influence of Age, Prosthesis-Patient Mismatch and Indexed Effective Orifice Area

Liberato Camilleri

ICF journal, 2017

View PDFchevron_right

Prosthesis-Patient Mismatch After Aortic Valve Replacement: Impact of Age and Body Size on Late Survival

Spencer Melby, Ian Burwash

The Annals of Thoracic Surgery, 2006

View PDFchevron_right

Influence of Prosthesis–Patient Mismatch on Diastolic Heart Failure After Aortic Valve Replacement

Shahab Nozohoor, Johan Sjögren

The Annals of Thoracic Surgery, 2008

View PDFchevron_right

Patient‐Prosthetic Aortic Valve Mismatch: Role of the Echocardiographer

Edmund Kerut

Echocardiography, 2005

View PDFchevron_right

Patient-prosthesis mismatch after minimally invasive aortic valve replacement

Maciej Brzezinski

Kardiologia Polska, 2018

View PDFchevron_right

No clinical effect of prosthesis–patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis of the NOTION trial

henrik nissen

European Journal of Cardio-Thoracic Surgery, 2016

View PDFchevron_right

Patient-prosthesis mismatch and strategies to prevent it during aortic valve replacement

Efstratios Apostolakis

Hellenic journal of cardiology : HJC = Hellēnikē kardiologikē epitheōrēsē

View PDFchevron_right

Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly

Riccardo Sinatra

European Journal of Cardio-Thoracic Surgery, 2006

View PDFchevron_right

Patient Prosthesis Mismatch in Aortic Valve Replacement - Size Does Not Matter

Radu Deac

ASAIO Journal, 2005

View PDFchevron_right

Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient–Prosthesis Mismatch a Relevant Phenomenon?

Vincenzo Montericcio

Annals of Thoracic Surgery, 2011

View PDFchevron_right

Ejection fraction/velocity ratio identifies prosthesis-patient mismatches in patients with aortic bioprosthetic valves and left ventricular dysfunction

Massimo Baravelli

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, 2009

View PDFchevron_right

Impact of Patient Prosthesis Mismatch on Short And Long-Term Mortality Outcomes After Aortic Valve Replacement

waleed ahmed

Heart, Lung and Circulation, 2010

View PDFchevron_right

Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures

Diego Gaia

JACC. Cardiovascular interventions, 2018

View PDFchevron_right

Patient-prosthesis mismatch in aortic valve replacement: really tolerable

sergio lopez

European Journal of Cardio-thoracic Surgery, 2005

View PDFchevron_right

The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement

Anders Roijer

The Journal of heart valve disease

View PDFchevron_right

Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis

Mario Gaudino

The Journal of Thoracic and Cardiovascular Surgery, 2005

View PDFchevron_right