Aortic valve prosthesis-patient mismatch and long-term outcomes: 19-year single-center experience (original) (raw)
Impact of Valve Prosthesis-Patient Mismatch on Left Ventricular Mass Regression Following Aortic Valve Replacement
Giovanni Troise, Marco Cirillo
The Annals of Thoracic Surgery, 2005
View PDFchevron_right
Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients
Abid Iqbal
Indian Journal of Thoracic and Cardiovascular Surgery, 2018
View PDFchevron_right
Impact of Prosthesis-Patient Mismatch on Cardiac Events and Midterm Mortality After Aortic Valve Replacement in Patients With Pure Aortic Stenosis
Giovanni Troise, Marco Cirillo
Circulation, 2006
View PDFchevron_right
Effect of Prosthesis-Patient Mismatch on Long-Term Survival With Aortic Valve Replacement: Assessment to 15 Years
Samuel Lichtenstein
The Annals of Thoracic Surgery, 2010
View PDFchevron_right
EFFECT OF PATIENT PROSTHESIS MISMATCH ON LEFT VENTRICLAR FUNCTION AND REGRESSION AFTER AORTIC VALVE REPLACEMENT FOR AORTIC STENOSIS
Husain H Jabbad
View PDFchevron_right
Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis: Impact of Prosthesis-Patient Mismatch
Ian Burwash
Circulation, 2006
View PDFchevron_right
Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆
Ardawan Rastan, S. Lehmann
European Journal of Cardio-Thoracic Surgery, 2006
View PDFchevron_right
Impact of Patient–Prosthesis Mismatch Following Aortic Valve Replacement on Short-Term Survival: A Retrospective Single Center Analysis of 632 Consecutive Patients with Isolated Stented Biological Aortic Valve Replacement
Georg Lutter
The Thoracic and Cardiovascular Surgeon, 2014
View PDFchevron_right
Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant
George Christakis
The Annals of Thoracic Surgery, 2002
View PDFchevron_right
Does patient–prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients?
Tommaso Regesta, Giancarlo Passerone
Journal of Cardiovascular Medicine, 2015
View PDFchevron_right
Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival
Jorge Mascaro
The Annals of Thoracic Surgery, 2010
View PDFchevron_right
Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prostheses
Luca Testa
JACC: Cardiovascular Interventions, 2019
View PDFchevron_right
Long-Term Survival Following Aortic Valve Replacement: the Influence of Age, Prosthesis-Patient Mismatch and Indexed Effective Orifice Area
Liberato Camilleri
ICF journal, 2017
View PDFchevron_right
Prosthesis-Patient Mismatch After Aortic Valve Replacement: Impact of Age and Body Size on Late Survival
Spencer Melby, Ian Burwash
The Annals of Thoracic Surgery, 2006
View PDFchevron_right
Influence of Prosthesis–Patient Mismatch on Diastolic Heart Failure After Aortic Valve Replacement
Shahab Nozohoor, Johan Sjögren
The Annals of Thoracic Surgery, 2008
View PDFchevron_right
Patient‐Prosthetic Aortic Valve Mismatch: Role of the Echocardiographer
Edmund Kerut
Echocardiography, 2005
View PDFchevron_right
Patient-prosthesis mismatch after minimally invasive aortic valve replacement
Maciej Brzezinski
Kardiologia Polska, 2018
View PDFchevron_right
No clinical effect of prosthesis–patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis of the NOTION trial
henrik nissen
European Journal of Cardio-Thoracic Surgery, 2016
View PDFchevron_right
Patient-prosthesis mismatch and strategies to prevent it during aortic valve replacement
Efstratios Apostolakis
Hellenic journal of cardiology : HJC = Hellēnikē kardiologikē epitheōrēsē
View PDFchevron_right
Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly
Riccardo Sinatra
European Journal of Cardio-Thoracic Surgery, 2006
View PDFchevron_right
Patient Prosthesis Mismatch in Aortic Valve Replacement - Size Does Not Matter
Radu Deac
ASAIO Journal, 2005
View PDFchevron_right
Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient–Prosthesis Mismatch a Relevant Phenomenon?
Vincenzo Montericcio
Annals of Thoracic Surgery, 2011
View PDFchevron_right
Ejection fraction/velocity ratio identifies prosthesis-patient mismatches in patients with aortic bioprosthetic valves and left ventricular dysfunction
Massimo Baravelli
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, 2009
View PDFchevron_right
Impact of Patient Prosthesis Mismatch on Short And Long-Term Mortality Outcomes After Aortic Valve Replacement
waleed ahmed
Heart, Lung and Circulation, 2010
View PDFchevron_right
Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures
Diego Gaia
JACC. Cardiovascular interventions, 2018
View PDFchevron_right
Patient-prosthesis mismatch in aortic valve replacement: really tolerable
sergio lopez
European Journal of Cardio-thoracic Surgery, 2005
View PDFchevron_right
The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement
Anders Roijer
The Journal of heart valve disease
View PDFchevron_right
Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis
Mario Gaudino
The Journal of Thoracic and Cardiovascular Surgery, 2005
View PDFchevron_right