Analysis on Methods to obtain Lumped Parameters for an Inductive Coupling Device (original) (raw)
Related papers
Modeling and Measurements of Properties of Coupled Inductors
Energies, 2021
This paper proposes a model of a coupled inductor which takes into account the influence of frequency, temperature, and a constant component, IDC, of currents in the windings on the parameters of the considered element. A description of the model and methods of measuring parameters of the inductor using an impedance analyzer and a chamber for thermal measurements is given. The obtained results of measurements are compared with the results of calculations proving a satisfactory match.
A novel method to improve the measurement accuracy of mutual inductance transmission line parameters
2012 IEEE 15th International Conference on Harmonics and Quality of Power, 2012
In this paper, a novel method of adaptive singleended sweep measurement can be used for measurement the mutual inductance transmission line parameters is presented. The principle of this method is based on non-linear frequency response analysis of transmission line parameters. The measurement accuracy is significantly improved by using adaptive signal processing technology to eliminate the power frequency induced voltage and current. In addition, the traditional methods based on series R-L transmission line model, the shunt capacitive effect is ignored. Obviously, these algorithms are not accurate enough, particularly for medium and long transmission line. The proposed optimal algorithm is based on differential equation using the distributed parameter π-model and thus fully considers the effects of shunt capacitance and distributed parameter effects of long lines. This paper presents the theory of the technique, the design of hardware platform and software. The results of the simulation experiments are demonstrate its reliable performance.
Energies
In this paper, we propose a measurement method with a simple procedure based on the definition of the impedance parameter using a two-port network analyzer. The main advantage of the proposed measurement method is that there is no limit on the number of measuring coils, and the method has a simple measurement procedure. To verify the proposed method, we measured the coupling coefficient among three coils with respect to the distance between the two farthest coils at 6.78 and 13.56 MHz, which are frequencies most common for a wireless power transfer (WPT) system in high-frequency band. As a result, the proposed method showed good agreement with results of the conventional S-parameter measurement methods.
Evaluation Of Coupling Factor In Rf Inductively Coupled Systems
2012
This work presents an approach for the measurement of mutual inductance on near field inductive coupling. The mutual inductance between inductive circuits allows the simulation of energy transfer from reader to tag, that can be used in RFID and powerless implantable devices. It also allows one to predict the maximum voltage in the tag of the radio-frequency system.
A Compensation Method to Measure the Mutual Inductance at Low Frequency
IEEE Transactions on Instrumentation and Measurement, 2011
Traditionally, the most precise way to get the mutual inductance value is by a Campbell calculable mutual inductor. Here, an approach of measuring the mutual inductance at low frequency with compensation method is described. A multi-channel direct digital frequency synthesis source is developed to provide stable and precise phase. The mutual inductance is traced to the value of the frequency and resistance directly. The measurement uncertainty is 0.43 ppm at present and could be improved further.
Mapping Methodology for Self and Mutual Inductance Profiles in IPT Systems
Energies
Magnetic couplers (MC) are the key element that enable the power transfer over large air gaps in inductive power transfer (IPT) systems. Numerous designs with different coil and core arrangements have been proposed in the literature. However, the MC sizing process still involves several trial and error iterations to meet the desired specifications. This paper presents a profile methodology that uses fitting equations to extrapolate the coupling profiles and minimize the required number of finite element analysis (FEA) simulation results. A non-polarized circular coupler (FLCP) can be characterized as function of the air gap and lateral displacements using only six charging positions, whereas polarized couplers, such as the bipolar (BPP) or double-D pad (DDP), can be characterized using 18 charging positions. The methodology is validated experimentally using the FLCP, and an average error of 3% was found under different charging positions.
Electronics, 2021
Inductive power transfer (IPT) applications, such as stationary charging of electric vehicles (EVs), at least moderate coupling between the coils to achieve high efficiency, but the coefficient k typically varies between of 0.1 to 0.4, depending on the displacement of the coils according to SAE J2954. Thus, accurate and reliable methods for estimation of k are required for positioning of the EV to achieve optimal alignment with the charging pad. Additionally, in IPT, numerous control strategies are available for regulating output power and optimizing system efficiency that require an accurate estimate of the mutual inductance or k. However, existing estimation methods tend to require detailed a-priori information of a large number of circuit parameters, or they need measurement of currents or voltages in both primary and secondary sides. This paper presents a preliminary evaluation of a novel, primary-side method to estimate k, which is based solely on the frequency response of the ...
IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Wide band gap devices have enabled miniaturization of the magnetic components to enhance the power density of the converter. However, parasitic components become dominant at higher switching frequencies that actuate unwanted electromagnetic interference issues. Therefore, it is critical to model and evaluate them in compact magnetic structures. Since multiwinding coupled inductive structures are essential part of multiphase converters, this paper introduces a measurement method to compute the parasitic elements of a three-winding coupled inductor. Results of the proposed method are verified by measuring the high-frequency emissions of the high stepup converter with two inductor structures. Both inductors had similar inductances but different physical dimensions. With application of the proposed measurement methodology, parasitic capacitances of both inductors were computed. Results showed that one inductor structure has higher parasitic capacitance than the other. Since, high-frequency emissions of the converter directly depends on the parasitic capacitance of the inductor structure, emission profile of the converter showed that converter indeed had lower noise peaks when inductor with lower capacitance was employed. Hence, these results validate the capacitance trend as predicted by the proposed modeling technique. This method can be employed to any multiwinding coupled inductor to compute its parasitics to optimize the required EMI filters.
A Multi-MHz IPT-link Developed for Load Characterisation at Highly Variable Coupling Factor
2018 IEEE Wireless Power Transfer Conference (WPTC)
This paper presents the development and characterisation of an inductive link to assess and compare inductive power transfer (IPT) systems that operate at 6.78 or 13.56 MHz. First, the properties of two equal air-core coils were obtained from simulations and corroborated experimentally. Then, the coupling factor between the coils was calculated in function of separation and misalignment. A receiving-end circuit, comprised of a capacitance and a resistive load, was also characterised in order to reflect different loads to the transmitter at different tunings and couplings, and therefore represent the effects produced by changes in coupling and variations in the rectifier's input impedance. The link was tested, firstly using a Class E inverter and then a load-independent Class EF inverter, both at power levels lower than 200 W. The reflected load was changed by altering coupling, and the tuning capacitance. A comparison between these inverter topologies handling highly reactive loads is shown here for the first time.