Reproducibility of coronary atherosclerotic plaque characteristics in populations with low, intermediate, and high prevalence of coronary artery disease by multidetector computer tomography: a guide to reliable visual coronary plaque assessments (original) (raw)

2016, The International Journal of Cardiovascular Imaging

y CAD, and determination of coronary stenosis) showed good agreement among the four readers, (ICC = 0.66, κ = 0.73, ICC = 0.74, respectively). When accounting for heart rate, body mass index, plaque location, and coronary stenosis above/below 50 %, interobserver agreement for plaque composition, presence of CAD, and coronary stenosis improved to either good or excellent, (κ = 0.61, κ = 0.81, ICC = 0.78, respectively). Spotty calcification was the least reproducible parameter investigated (κ = 0.33). Across subpopulations, reproducibility of coronary plaque characteristics generally decreased with increasing CAD prevalence except for plaque composition, (limits of agreement: ±2.03, ±1.96, ±1.79 for low, intermediate and high CAD prevalence, respectively). 320-slice MDCT can be used to assess coronary plaque characteristics, except for spotty calcification. Reproducibility estimates are influenced by heart rate, body size, plaque location, and degree of luminal stenosis.