In-Vitro Simulation of the Blood Flow in an Axisymmetric Abdominal Aortic Aneurysm (original) (raw)
Effects of Intraluminal Thrombus on Patient-Specific Abdominal Aortic Aneurysm Hemodynamics via Stereoscopic Particle Image Velocity and Computational Fluid Dynamics Modeling
Prahlad Menon
Journal of Biomechanical Engineering, 2014
View PDFchevron_right
Experimental study of aortic flow in the ascending aorta via Particle Tracking Velocimetry
Utku Gülan, Wolfgang Kinzelbach, Alex Liberzon
2012
View PDFchevron_right
Simultaneous 3D-FLOW Field and Compliant Wall Measurements in a Abdominal Aortic Aneurysm Flow Using Scanning-PTV
Klaus Hoyer
View PDFchevron_right
Experimental investigation of steady flow in rigid models of abdominal aortic aneurysms
Edward Bluth
Annals of Biomedical Engineering, 1995
View PDFchevron_right
Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents
Y. Hoi
Medical Imaging 2004: Physiology, Function, and Structure from Medical Images, 2004
View PDFchevron_right
Quantification of Particle Residence Time in Abdominal Aortic Aneurysms Using Magnetic Resonance Imaging and Computational Fluid Dynamics
Janice Yeung, Andrea Les
Annals of Biomedical Engineering, 2011
View PDFchevron_right
Comparison of Flow Measurement by 4D Flow Magnetic Resonance Imaging and by Particles Image Velocimetry on Phantom of Abdominal Aortic Aneurysm
JF FONTAINE
2016
View PDFchevron_right
CFD and PTV Steady Flow Investigation in an Anatomically Accurate Abdominal Aortic Aneurysm
Evangelos Boutsianis
Journal of Biomechanical Engineering-transactions of The Asme, 2009
View PDFchevron_right
Experimental unsteady flow study in a patient-specific abdominal aortic aneurysm model
Dimitris Mathioulakis
2011
View PDFchevron_right
Development of Particle Image Velocimetry for In-Vitro Studies of Arterial Haemodynamics
Nicolas Buchmann
2010
View PDFchevron_right
Flow of a blood analogue fluid in a compliant abdominal aortic aneurysm model: Experimental modelling
Lucie Bailly, Eric Bertrand
Journal of Biomechanics, 2014
View PDFchevron_right
Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetry
Zahra Motamed
Experiments in Fluids, 2014
View PDFchevron_right
Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
Callum Atkinson, Julio Soria
Experiments in Fluids, 2011
View PDFchevron_right
Pulsatile Flow Investigation in Development of Thoracic Aortic Aneurysm: An In-Vitro Validated Fluid Structure Interaction Analysis
Fangsen Cui
Journal of Applied Fluid Mechanics, 2019
View PDFchevron_right
Steady Flow in an Aneurysm Model: Correlation Between Fluid Dynamics and Blood Platelet Deposition
Mrinal Dewanjee
Journal of Biomechanical Engineering, 1996
View PDFchevron_right
Particle Image Velocimetry (PIV) and Computational Fluid Dynamics (CFD) Modelling of Carotid Artery Haemodynamics under Steady Flow: A Validation Study
Nicolas Buchmann
Journal of Biomechanical Science and Engineering, 2010
View PDFchevron_right
Intra-Aneurysmal Flow Patterns: Illustrative Comparison among Digital Subtraction Angiography, Optical Flow, and Computational Fluid Dynamics
Karl Schaller, Philippe Bijlenga, Daniel Ruijters
2014
View PDFchevron_right
An Euler–Lagrange approach for studying blood flow in an aneurysmal geometry
Michalis Xenos
Proceedings of The Royal Society A: Mathematical, Physical and Engineering Sciences, 2017
View PDFchevron_right
In vitro pulsatile flow study in compliant and rigid ascending aorta phantoms by stereo particle image velocimetry
Mark Jermy
Medical Engineering & Physics, 2021
View PDFchevron_right
Wall-PIV as a near wall flow validation tool for CFD: Application in a pathologic vessel enlargement (aneurysm)
L. Goubergrits, Hans-Christian Hege
Journal of Visualization, 2009
View PDFchevron_right
Multi-time-lag PIV analysis of steady and pulsatile flows in a sidewall aneurysm
Mohamed Farhat, rafik ouared, Karl Lovblad
Experiments in Fluids, 2014
View PDFchevron_right
Axisymmetric and Non-Axisymmetric Flow and Wall Shear Stress in a Model Fusiform Abdominal Aortic Aneurysm
Rainald Lohner
2009
View PDFchevron_right
An in vitro investigation of the influence of stenosis severity on the flow in the ascending aorta
Beat Luethi
Medical Engineering & Physics, 2014
View PDFchevron_right
Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics
Paul Summers
NMR in Biomedicine, 2009
View PDFchevron_right
Dynamics of pulsatile flow through model abdominal aortic aneurysms
Shyam Sunder Gopalakrishnan
Journal of Fluid Mechanics, 2014
View PDFchevron_right
Impact of hemodynamics on lumen boundary displacements in abdominal aortic aneurysms by means of dynamic computed tomography and computational fluid dynamics
Pietro Biondetti
Biomechanics and Modeling in Mechanobiology, 2013
View PDFchevron_right
NUMERICAL INVESTIGATION OF BLOOD FLOW THROUGH ABDOMINAL ANEURYSMS
TJPRC Publication
View PDFchevron_right
PIV-Measured Versus CFD-Predicted Flow Dynamics in Anatomically Realistic Cerebral Aneurysm Models
Francis Loth
Journal of Biomechanical Engineering, 2008
View PDFchevron_right