In-Vitro Simulation of the Blood Flow in an Axisymmetric Abdominal Aortic Aneurysm (original) (raw)

Effects of Intraluminal Thrombus on Patient-Specific Abdominal Aortic Aneurysm Hemodynamics via Stereoscopic Particle Image Velocity and Computational Fluid Dynamics Modeling

Prahlad Menon

Journal of Biomechanical Engineering, 2014

View PDFchevron_right

Experimental study of aortic flow in the ascending aorta via Particle Tracking Velocimetry

Utku Gülan, Wolfgang Kinzelbach, Alex Liberzon

2012

View PDFchevron_right

Simultaneous 3D-FLOW Field and Compliant Wall Measurements in a Abdominal Aortic Aneurysm Flow Using Scanning-PTV

Klaus Hoyer

View PDFchevron_right

Experimental investigation of steady flow in rigid models of abdominal aortic aneurysms

Edward Bluth

Annals of Biomedical Engineering, 1995

View PDFchevron_right

Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents

Y. Hoi

Medical Imaging 2004: Physiology, Function, and Structure from Medical Images, 2004

View PDFchevron_right

Quantification of Particle Residence Time in Abdominal Aortic Aneurysms Using Magnetic Resonance Imaging and Computational Fluid Dynamics

Janice Yeung, Andrea Les

Annals of Biomedical Engineering, 2011

View PDFchevron_right

Comparison of Flow Measurement by 4D Flow Magnetic Resonance Imaging and by Particles Image Velocimetry on Phantom of Abdominal Aortic Aneurysm

JF FONTAINE

2016

View PDFchevron_right

CFD and PTV Steady Flow Investigation in an Anatomically Accurate Abdominal Aortic Aneurysm

Evangelos Boutsianis

Journal of Biomechanical Engineering-transactions of The Asme, 2009

View PDFchevron_right

Experimental unsteady flow study in a patient-specific abdominal aortic aneurysm model

Dimitris Mathioulakis

2011

View PDFchevron_right

Development of Particle Image Velocimetry for In-Vitro Studies of Arterial Haemodynamics

Nicolas Buchmann

2010

View PDFchevron_right

Flow of a blood analogue fluid in a compliant abdominal aortic aneurysm model: Experimental modelling

Lucie Bailly, Eric Bertrand

Journal of Biomechanics, 2014

View PDFchevron_right

Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetry

Zahra Motamed

Experiments in Fluids, 2014

View PDFchevron_right

Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation

Callum Atkinson, Julio Soria

Experiments in Fluids, 2011

View PDFchevron_right

Pulsatile Flow Investigation in Development of Thoracic Aortic Aneurysm: An In-Vitro Validated Fluid Structure Interaction Analysis

Fangsen Cui

Journal of Applied Fluid Mechanics, 2019

View PDFchevron_right

Steady Flow in an Aneurysm Model: Correlation Between Fluid Dynamics and Blood Platelet Deposition

Mrinal Dewanjee

Journal of Biomechanical Engineering, 1996

View PDFchevron_right

Particle Image Velocimetry (PIV) and Computational Fluid Dynamics (CFD) Modelling of Carotid Artery Haemodynamics under Steady Flow: A Validation Study

Nicolas Buchmann

Journal of Biomechanical Science and Engineering, 2010

View PDFchevron_right

Intra-Aneurysmal Flow Patterns: Illustrative Comparison among Digital Subtraction Angiography, Optical Flow, and Computational Fluid Dynamics

Karl Schaller, Philippe Bijlenga, Daniel Ruijters

2014

View PDFchevron_right

An Euler–Lagrange approach for studying blood flow in an aneurysmal geometry

Michalis Xenos

Proceedings of The Royal Society A: Mathematical, Physical and Engineering Sciences, 2017

View PDFchevron_right

In vitro pulsatile flow study in compliant and rigid ascending aorta phantoms by stereo particle image velocimetry

Mark Jermy

Medical Engineering & Physics, 2021

View PDFchevron_right

Wall-PIV as a near wall flow validation tool for CFD: Application in a pathologic vessel enlargement (aneurysm)

L. Goubergrits, Hans-Christian Hege

Journal of Visualization, 2009

View PDFchevron_right

Multi-time-lag PIV analysis of steady and pulsatile flows in a sidewall aneurysm

Mohamed Farhat, rafik ouared, Karl Lovblad

Experiments in Fluids, 2014

View PDFchevron_right

Axisymmetric and Non-Axisymmetric Flow and Wall Shear Stress in a Model Fusiform Abdominal Aortic Aneurysm

Rainald Lohner

2009

View PDFchevron_right

An in vitro investigation of the influence of stenosis severity on the flow in the ascending aorta

Beat Luethi

Medical Engineering & Physics, 2014

View PDFchevron_right

Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics

Paul Summers

NMR in Biomedicine, 2009

View PDFchevron_right

Dynamics of pulsatile flow through model abdominal aortic aneurysms

Shyam Sunder Gopalakrishnan

Journal of Fluid Mechanics, 2014

View PDFchevron_right

Impact of hemodynamics on lumen boundary displacements in abdominal aortic aneurysms by means of dynamic computed tomography and computational fluid dynamics

Pietro Biondetti

Biomechanics and Modeling in Mechanobiology, 2013

View PDFchevron_right

NUMERICAL INVESTIGATION OF BLOOD FLOW THROUGH ABDOMINAL ANEURYSMS

TJPRC Publication

View PDFchevron_right

PIV-Measured Versus CFD-Predicted Flow Dynamics in Anatomically Realistic Cerebral Aneurysm Models

Francis Loth

Journal of Biomechanical Engineering, 2008

View PDFchevron_right