Practical Implications of using Nanoelectrodes for Bioanalytical Measurements (original) (raw)
Related papers
Advanced data acquisition for emerging nano-electrochemical sensors
2018
This paper describes a low cost portable point of test data acquisition system, made of commercial components, that was developed to interface to electrochemical sensors. The proposed system has demonstrated that it can support cyclic voltammetry, square wave voltammetry and collector generator voltammetry, with dual electrode control. The system has demonstrated its capability to detect a range of ferrocene monocarboxylic acid concentrations using nanowire electrochemical sensors, while benchmarking the results against dedicated laboratory based equipment. This work has identified and highlighted the unique challenges of interfacing to electrochemical sensors.
Voltammetry of redox analytes at trace concentrations with nanoelectrode ensembles
Talanta, 2004
Gold nanoelectrodes ensembles (NEEs) have been prepared by electroless plating of Au nanoelectrode elements within the pores of a microporous polycarbonate template membrane. Cyclic voltammograms recorded in (ferrocenylmethyl) trimethylammonium hexafluorophosphate (FA + PF 6 − ) solutions showed that these NEEs operate in the "total-overlap" response regime, giving well resolved peak shaped voltammograms. Experimental results show that the faradaic/background currents ratios at the NEE are independent on the total geometric area of the ensemble, so that NEE can be enlarged or miniaturized at pleasure without influencing the very favorable signal/noise ratio. Differential pulse voltammetry (DPV) at the NEE is optimized for direct determinations at trace levels. DPV at NEE allowed the determination (with no preconcentration) of trace amounts of FA + , with a detection limit of 0.02 M. The use of NEE and DPV in cytochrome c (cyt c) solutions showed the possibility to observe the direct electrochemistry of submicromolar concentration of the protein, even without the need of adding any promoter or mediator.
In the current study, a novel electrode array and integrated microfluidics have been designed and characterised in order to create a sensor chip which is not only easy, rapid and cheaper to produce but also have a smaller imprint and good electrochemical sensing properties. The current study includes the assessment of the effects of an Au quasi-reference electrode and the use of shared reference/counter electrodes for the array, in order to obtain a small array that can be produced using a fine metal mask. In the study, it is found that when Au is used as the quasi-reference electrode, the arrays with shared reference and counter electrodes result in faster electron transfer kinetics and prevent the potential change with respect to scan rate, and hence is advantageous with respect to conventional electrodes. In addition, the resulting novel electrode array has been shown to result in higher current density (10.52 µA/cm2; HRP detection assay) and measured diffusion coefficient (14.40×10−12 cm2/s; calculated from the data of cyclic voltammetry with 1 mM potassium ferricyanide) with respect to conventional electrodes tested in the study. Using the new electrode arrays, the detection limits obtained from horse radish peroxidase (HRP) and bisphenol A assays were 12.5 ng/ml (2.84×10−10 M ) and 10 ng/ml (44×10−9 M), respectively. Performing the HRP detection assay in a flow injection system using array integrated microfluidics provided 25 times lower detection limit (11.36×10−12 M), although Ti has been used as electrode material instead of Au. In short, incorporation of this new electrode array to lab-on-a-chip or MEMs (micro-electro mechanic systems) technologies may pave the way for easy to use automated biosensing devices that could be used for a variety of applications from diagnostics to environmental monitoring, and studies will continue to move forward in this direction.
Electroanalytical and Bioelectroanalytical Systems Based on Metal and Semiconductor Nanoparticles
Electroanalysis, 2004
Metal, semiconductor and magnetic particles act as functional units for electroanalytical applications. Metal nanoparticles provide three important functions for electroanalysis. These include the roughening of the conductive sensing interface, the catalytic properties of the nanoparticles permiting their enlargement with metals and the amplified electrochemical detection of the metal deposits and the conductivity properties of nanoparticles at nanoscale dimensions that allow the electrical contact of redox-centers in proteins with electrode surfaces. Also, metal and semiconductor nanoparticles provide versatile labels for amplified electroanalysis. Dissolution of the nanoparticle labels and the electrochemical collection of the dissolved ions on the electrode followed by the stripping-off of the deposited metals represents a general electroanalytical procedure. These unique functions of nanoparticles were employed for developing electrochemical gas sensors, electrochemical sensors based on molecular-or polymerfunctionalized nanoparticle sensing interfaces, and for the construction of different biosensors including enzymebased electrodes, immunosensors and DNA sensors. Semiconductor nanoparticles enable the photoelectrochemical detection of analytes. Several studies have revealed the photocurrent generation by enzyme-mediated processes and as a result of DNA hybridization. Magnetic particles act as functional components for the separation of biorecognition complexes and for the amplified electrochemical sensing of DNA or antigen/antibody complexes. Also, electrocatalytic and bioelectrocatalytic processes at electrode surfaces are switched by means of functionalized magnetic particles and in the presence of an external magnet.
2015
We have mounted 5 different biocatalysts on a sensor platform to examine the performance of this electrochemical sensing system for the detection of different biomolecules/metabolites and environmental important molecules, with such we also compared how this sensing system fares with literature results of similar measurements. The biocatalysts are LDH (lactate dehydrogenase), GDH (glutamate dehydrogenase), human IgG (human immunoglobulin G), Hb (hemoglobin), and PSA (prostatespecific antigen). The sensor platform constitutes of a layer of biocomposite mounted on different electrodes made out of Au, Ag, Pt, and glass carbon; the biocomposite is fabricated with polymers and sol-gel Au nanoparticles with or without an extra layer of biomolecules. The targeting species for measurements include NH4, NO3, CN, H2O2 and the biomolecules specific to the biomolecules/antigens coated on the surface of the biocomposites. In this report, we will provide a comprehensive analysis of this sensing s...
Nanoenabling electrochemical sensors for life sciences applications
Journal of Materials Research
Electrochemical sensing systems are advancing into a wide range of new applications, moving from the traditional lab environment into disposable devices and systems, enabling real-time continuous monitoring of complex media. This transition presents numerous challenges ranging from issues such as sensitivity and dynamic range, to auto-calibration and antifouling, to enabling multiparameter analyte and biomarker detection from an array of nanosensors within a miniaturized form factor. New materials are required not only to address these challenges, but also to facilitate new manufacturing processes for integrated electrochemical systems. This paper examines the recent advances in the instrumentation, sensor architectures and sensor materials in the context of developing the next generation of nano-enabled electrochemical sensors for life sciences applications, and identifies the most promising solutions based on selected well established application exemplars.
Electrochemical Nanosized Biosensors: Perspectives and Future of Biocatalysts
Journal of Analytical & Bioanalytical Techniques, 2013
Electrochemical biological sensor device unite the sensitivity of classic instrumental techniques with the inseparable selectivity of the biological agent. The bio-element of the sensing device identifies the analyte following in a biocatalytic way and definitely generates an electrical response recorded by a transducing element. The signal is proportional to concentration of the analyzed substance. Certain of developed modern biosensors are commercial available and are regularly applied in clinical, environmental, or industrial arrangements. The enzymatic electrode is often the principal element of electrochemical biosensors. The choice of suitable composition of agents, in example: biocatalyst, mediators, semiconducting elements, supports, for design of enzymatic sensors directs an electrode activity according to electron transport rate, its stability, and vitality. Presented article underlined also the variety of technologies for creation of sensors basing on carbon nanotubes and their application in detecting of a numerous of biological molecules.
Ultrasensitive Electrochemical Biomolecular Detection Using Nanostructured Microelectrodes
Accounts of Chemical Research, 2014
CONSPECTUS: Electrochemical sensors have the potential to achieve sensitive, specific, and low-cost detection of biomoleculesa capability that is ever more relevant to the diagnosis and monitored treatment of disease. The development of devices for clinical diagnostics based on electrochemical detection could provide a powerful solution for the routine use of biomarkers in patient treatment and monitoring and may overcome the many issues created by current methods, including the long sample-to-answer times, high cost, and limited prospects for lab-free use of traditional polymerase chain reaction, microarrays, and gene-sequencing technologies. In this Account, we summarize the advances in electrochemical biomolecular detection, focusing on a new and integrated platform that exploits the bottom-up fabrication of multiplexed electrochemical sensors composed of electrodeposited noble metals. We trace the evolution of these sensors from gold nanoelectrode ensembles to nanostructured microelectrodes (NMEs) and discuss the effects of surface morphology and size on assay performance. The development of a novel electrocatalytic assay based on Ru 3+ adsorption and Fe 3+ amplification at the electrode surface as a means to enable ultrasensitive analyte detection is discussed. Electrochemical measurements of changes in hybridization events at the electrode surface are performed using a simple potentiostat, which enables integration into a portable, cost-effective device. We summarize the strategies for proximal sample processing and detection in addition to those that enable high degrees of sensor multiplexing capable of measuring 100 different analytes on a single chip. By evaluating the cost and performance of various sensor substrates, we explore the development of practical lab-on-a-chip prototype devices. By functionalizing the NMEs with capture probes specific to nucleic acid, small molecule, and protein targets, we can successfully detect a wide variety of analytes at clinically relevant concentrations and speeds. Using this platform, we have achieved attomolar detection levels of nucleic acids with overall assay times as short as 2 min. We also describe the adaptation of the sensing platform to allow for the measurement of uncharged analytesa challenge for reporter systems that rely on the charge of an analyte. Furthermore, the capabilities of this system have been applied to address the many current and important clinical challenges involving the detection of pathogenic species, including both bacterial and viral infections and cancer biomarkers. This novel electrochemical platform, which achieves large molecular-to-electrical amplification by means of its unique redox-cycling readout strategy combined with rapid and efficient analyte capture that is aided by nanostructured microelectrodes, achieves excellent specificity and sensitivity in clinical samples in which analytes are present at low concentrations in complex matrices.
Recent Developments, Characteristics, and Potential Applications of Electrochemical Biosensors
Analytical Sciences, 2004
The modern concept of biosensors represents a rapidly expanding field of instruments to determine the concentration of substances and other parameters of biological interest since the invention of Clark and Lyons in 1962, for example, created the availability of a rapid, accurate, and simple biosensor for glucose. Biological sensors are analytical devices that detect biochemical and physiological changes. Transducers are essential to convert the particular biological and chemical (biochemical) change into electrical data which can identify different biochemical components of a complex compound to isolate the desired biochemical compounds, for instance, carbon monoxide and sulfur dioxide that contribute to the air pollution. Historically, Clark and Lyons first demonstrated the modern concept of biosensors, in which an enzyme was integrated into an electrode to form a biosensor. The developments of such simple detection tools and similar techniques have made considerable progress since then. Early techniques of biosensors in the analysis of chemical and biological species involved reactions that took place in a solution in addition to catalysts and samples. In recent years, however, the biosensor techniques have provided alternative systems that allowed the reactions without adding reagents to take place at a surface of an electrode. Since the reagents have been already immobilized in the systems, the biological and chemical sensor has performed the task of identifying composition of species with minimum human intervention. The recent improvement of biosensor techniques has continued to depend on and learn from the inefficiency of the early techniques. 1-6 The most common immobilization techniques are physical 1113
On-Chip Electrochemical Analysis System Using Nanoelectrodes and Bioelectronic CMOS Chip
IEEE Sensors Journal, 2006
An electrochemical microanalysis system for reversible redox species determination has been presented. This system consists of a nanoelectrochemical sensor and a complimentary metal-oxide-semiconductor (CMOS) chip for sensor signal interfacing and conditioning. The nanoelectrochemical sensor is an interdigitated array nanoelectrode fabricated using e-beam lithography and ultraviolet lithography. The CMOS chip is designed and fabricated to realize the electrochemical analysis method of sensing, which is a switch-based method. Using this switch-based method, the potential dynamics of the nanoelectrodes is recorded to evaluate the species concentration. Experimental results have shown that the detection limit of this microanalysis system on reversible redox species is in the range of 1-10 nM. Index Terms-Bioelectronic complimentary metal-oxidesemiconductor (CMOS) chip, electrochemical analysis, nanoelectrodes, reversible redox species.