An integrated system for Peripherally Inserted Central Catheter tip confirmation in oncology and haematology patients (original) (raw)

Professioni infermieristiche, 2020

Abstract

INTRODUCTION Although there are many methods to confirm vascular device tip, chest x-ray represents the recommended procedure to verify the correct positioning of a central device, but it exposes patients to x-rays, delays treatment, and permits device length to be checked post-procedure. AIM To evaluate the efficacy of Peripherally Inserted Central Catheter positioning through an Integrated System (ultrasound-guided and electrocardiogram confirmation). METHODS A case-control study was conducted on a randomized sample of 165 patients, requiring Peripherally Inserted Central Catheter placement for chemotherapy treatment. The case group was composed of patients with vascular device placed through the Integrated System and the control group devices' length was anthropometrically estimated. Chest radiography was performed on both groups to verify tip location. RESULTS No cases of primary malposition related to the Integrated System were registered. The vascular devices positioned wi...