Detection and estimation of magnetization induced resonances in unilateral nuclear magnetic resonance (NMR) sensors (original) (raw)
Related papers
Unilateral NMR with a barrel magnet
Journal of Magnetic Resonance, 2017
Unilateral NMR can examine samples without regard to sample size. It is also an easy path to mobile or portable NMR as well as inexpensive NMR. The objective of this work was to develop unilateral NMR with an improved performance in a sample region that was remote from the apparatus. This was accomplished with the creation of a saddle point where all second derivatives of the main component of the field were nulled. A ∼10cm diameter ∼5cm thick magnet combined with a gradiometer coil on the surface detected signals from a sensitive region that extended ∼2cm from the magnet. The relatively homogeneous field of these unilateral NMR devices allows the measurement of rapidly diffusing spins as well as the use of smaller RF amplifiers, which enhances system mobility.
Remote detection of nuclear magnetic resonance with an anisotropic magnetoresistive sensor
Proceedings of the National Academy of Sciences, 2008
We report the detection of nuclear magnetic resonance (NMR) using an anisotropic magnetoresistive (AMR) sensor. A ''remotedetection'' arrangement was used in which protons in flowing water were prepolarized in the field of a superconducting NMR magnet, adiabatically inverted, and subsequently detected with an AMR sensor situated downstream from the magnet and the adiabatic inverter. AMR sensing is well suited for NMR detection in microfluidic ''lab-on-a-chip'' applications because the sensors are small, typically on the order of 10 m. An estimate of the sensitivity for an optimized system indicates that Ϸ6 ؋ 10 13 protons in a volume of 1,000 m 3 , prepolarized in a 10-kG magnetic field, can be detected with a signal-to-noise ratio of 3 in a 1-Hz bandwidth. This level of sensitivity is competitive with that demonstrated by microcoils in superconducting magnets and with the projected sensitivity of microfabricated atomic magnetometers.
Theory, Instrumentation and Applications of Magnetoelastic Resonance Sensors: A Review
Sensors, 2011
Thick-film magnetoelastic sensors vibrate mechanically in response to a time varying magnetic excitation field. The mechanical vibrations of the magnetostrictive magnetoelastic material launch, in turn, a magnetic field by which the sensor can be monitored. Magnetic field telemetry enables contact-less, remote-query operation that has enabled many practical uses of the sensor platform. This paper builds upon a review paper we published in Sensors in 2002 (Grimes, C.A.; et al. Sensors 2002, 2, 294-313), presenting a comprehensive review on the theory, operating principles, instrumentation and key applications of magnetoelastic sensing technology.
Geophysical Research Letters, 2014
The noninvasive detection and characterization of subsurface aquifer structures demands geophysical techniques. Surface nuclear magnetic resonance (surface NMR) is the only technique that is directly sensitive to hydrogen protons and, therefore, allows for unambiguous detection of subsurface water. Traditionally, surface NMR utilizes large surface coils for both transmitting excitation pulses and recording the groundwater response. Recorded data is thus a voltage induced by the time derivative of the secondary magnetic field. For the first time, we demonstrate that the secondary magnetic field in a surface NMR experiment can be directly detected using a SQUID magnetometer. Conducting measurements at a test site in Germany, we demonstrate not only the ability to detect surface NMR signals on the order of femtoTesla, but that we are able to satisfy the observed data by inverse modeling. This is expected to open up completely new applications for this exciting technology.
Sensors and Actuators A: Physical, 2008
The presented paper describes a magnetic field sensor system for the real-time monitoring of magnetic resonance (MR) image encoding in the presence of gradient and main magnetic field imperfections. For this purpose, a novel simplified design for nuclear magnetic resonance (NMR) probes has been developed. The design fulfills the requirements of providing below ppm measurement accuracy in combination with long readout times. To this end, NMR is performed with a nanoliter water volume, which together with the radiofrequency (RF) solenoid coil is cast into an Epoxy holder. Based on the Larmor relation (i.e. the proportionality between the NMR resonance frequency and the local B 0 ), time varying magnetic field information is extracted from the phase evolution of the detected RF signals. Susceptibility matching techniques are applied to homogenize the B 0 field across the NMR sample and in this way to extend the readout time of the NMR probes. The presented design of NMR probe is significantly simpler compared to previous presented ones by De Zanche et al. in the sense that it omits the glass capillary plus additional matching fluidics. The optimization of the susceptibility for the Epoxy is described and results of the probe characterization measurements are presented. The feasibility of magnetic field monitored MRI is demonstrated for ultra-fast single-and multishot data acquisition schemes. (P. Sipilä). between the two spin states:
The NMR sensitivity achievable with a slotted-tube resonator
MAGMA Magnetic Resonance Materials in Physics, Biology, and Medicine, 1993
The signal-to-noise ratio achievable with the slotted-tube resonator (STR), a fundamental type of high radiofrequency coil for nuclear magnetic resonance (NMR) experiments, was formulated in an equation. This equation is based on formulae presented by Hour and Richards UMagn Reson 24, 71 (1976)] and Hoult and Lauterbur [JMagn Reson 34, 425 (1979)]. The equation assumes that the sample is positioned within the homogeneous region of magnetic flux B1 generated by the STR, and involves no unknown factors. The.NMR sensitivity of an experiment with an STR can therefore be predicted, and the equation is applicable to any nuclear species, static field strength, and dimensions of the sample and STR.
Low-frequency NMR with a non-resonant circuit
Journal of Magnetic Resonance, 2011
Nuclear magnetic resonance typically utilizes a tuned resonance circuit with impedance matching to transmit power and receive signal. The efficiency of such a tuned coil is often described in terms of the coil quality factor, Q. However, in field experiments such as in well-logging, the circuit Q can vary dramatically throughout the depth of the wellbore due to temperature or fluid salinity variations. Such variance can result in erroneous setting of NMR circuit parameters (tuning and matching) and subsequent errors in measurements. This paper investigates the use of a non-resonant transmitter to reduce the circuit sensitivity on Q and demonstrates that such circuits can be efficient in delivering power and current to the coil. We also describe a tuned receiver circuit whose resonant frequency can be controlled digitally. Experimental results show that a range of common NMR experiments can be performed with our circuits.The illustration shows a non-resonant NMR transmitter circuit based on four switches. Waveforms used to control the switches are also shown.► We use a non-resonant NMR transmitter to reduce the circuit sensitivity to coil Q. ► We show that this circuit can efficiently deliver current to the NMR coil. ► We describe a digitally-tunable low-noise receiver circuit. ► A range of common NMR measurements has been performed with these circuits.
Force-detected magnetic resonance without field gradients
Solid State Nuclear Magnetic Resonance, 1998
. A novel method of nuclear magnetic resonance NMR is described which promises to be preferable to known general methods at sample length scales below ; 100 mm. Its advantages stem from the seemingly paradoxical combination of a homogeneous static magnetic field and detection of a mechanical force between a spin-bearing sample and a magnet Ž . assembly. In contrast to other methods of force-detected nuclear magnetic resonance FDNMR , the method is characterized Ž . by better observation of magnetization, enhanced resolution, and no g radient BOOMERANG , and it is generally applicable with respect to sample composition, pulse sequence, and magnetic field strength. Further advantages of portability and low cost stem from the small instrument volume and mass and promise to extend the use of NMR to new applications and environments. A sensitivity analysis, relevant to spectroscopy or imaging, quantifies the advantage of BOOMERANG relative to magnetic induction using microcoils and to FDNMR methods that rely on large gradients of the magnetic field at the sample. q 1998 Elsevier Science B.V.
Wireless Magnetoelastic Resonance Sensors: A Critical Review
Sensors, 2002
This paper presents a comprehensive review of magnetoelastic environmental sensor technology; topics include operating physics, sensor design, and illustrative applications. Magnetoelastic sensors are made of amorphous metallic glass ribbons or wires, with a characteristic resonant frequency inversely proportional to length. The remotely detected resonant frequency of a magnetoelastic sensor shifts in response to different physical parameters including stress, pressure, temperature, flow velocity, liquid viscosity, magnetic field, and mass loading. Coating the magnetoelastic sensor with a mass changing, chemically responsive layer enables realization of chemical sensors. Magnetoelastic sensors can be remotely interrogated by magnetic, acoustic, or optical means. The sensors can be characterized in the time domain, where the resonant frequency is determined through analysis of the sensor transient response, or in the frequency domain where the resonant frequency is determined from the frequency-amplitude spectrum of the sensor.
First Evidence of Surface-NMR Signals Detected Using a B-Field Sensor
Symposium on the Application of Geophysics to Engineering and Environmental Problems 2014, 2014
Key Points:• First detection of surface NMR signal using a compact B-field 3 sensor • Demonstrated use of forward and inverse modelling for surface NMR 4 signals • Discussion of new uses of compact B-field sensors for surface NMR 5 measurements 6 Abstract: The noninvasive detection and characterization of subsurface aquifer 7 structures demands geophysical techniques. Surface nuclear magnetic reso-8 nance (SNMR) is the only technique that is directly sensitive to hydrogen 9