Comparison of universal detectors for high-temperature micro liquid chromatography (original) (raw)
Related papers
Investigation of the analytical performance of aerosol-based detectors in liquid chromatography
2015
A non-discriminating, robust and economical detection system, which can be easily coupled with different modes of separation, is highly desirable in the field of liquid chromatography. While the evaporative light scattering detector (ELSD) and the corona-charged aerosol detector (C-CAD) hold great promise to meet these requirements, the widespread applicability of these techniques has been hindered due to lower sensitivity and solvent dependency of the detection response. This work presents an investigation into different experimental approaches to overcome these limitations, so as to extend the field of applicability of ELSD and C-CAD. Hyphenation of high temperature liquid chromatography (HTLC) using waterrich mobile phases with ELSD / C-CAD is an attractive solution to the solvent dependency limitations of these detectors and also offers a better detection alternative for HTLC. Therefore, experiments were conducted to investigate the effect of HTLC conditions using water-rich mob...
Journal of Chromatography A, 1985
The mass detector, a light scattering detector for use with high-performance liquid chromatography systems, was studied in order to determine which factors might affect sensitivity and quantification in the determination of triglycerides and other lipid materials. The detector response was found to be non-linear for triglycerides. The sensitivity was not only affected by evaporation temperatures and atomiser inlet air pressures within the detector, but also by the mobile phase flow-rate, and its composition. Detection limits of less than 1 pg were achieved for non-volatile, saturated triglycerides, by direct injection, and the reproducibility of responses was about f 6% with isocratic elution (excluding tributyrin which was too volatile to be quantified accurately), but somewhat greater (f 16%) with gradient elution.
Universal Response in Liquid Chromatography Using Charged Aerosol Detection
Analytical Chemistry, 2006
A new, empirical approach is introduced to correct for the varying response of aerosol-based detectors with the varying composition of the mobile phase during gradient elution in HPLC. A Corona charged aerosol detector was used in the experiments. The detector is characterized by a nearly universal response at a given, constant mobile-phase composition for sufficiently nonvolatile analytes. A second pump was used to deliver an exactly inverse gradient compared to the analytical HPLC system, and both flows were mixed in a tee piece before introduction to the Corona detector. The approach proposed made it possible to extend the universal response from isocratic to gradient elution conditions in HPLC, vastly improving the usefulness of this detection technique. The constant response of the detector obtained in this way was first demonstrated in flow injection analysis. Very similar calibration curves were obtained for six sulfonamide drugs after mobile-phase compensation. The approach was also applied to gradient elution with excellent results. The data were characterized by good precision ranging from 4% RSD at 10 mg/L to 1.6% RSD at 780 mg/L. The average limit of detection with a 2-microL injection was 0.5 mg/L, corresponding to 1 ng injected on the column. The approach proposed allows quantification of unknown compounds, e.g., in pharmaceutical mixtures. Measurement of analytes at a relative concentration of 0.05% versus the main component is demonstrated.
Capillary liquid chromatography?microchip atmospheric pressure chemical ionization?mass spectrometry
Lab on a Chip, 2006
A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l 21). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.
HPLC analysis of nonvolatile analytes using charged aerosol detection
2005
There continues to be strong demand for improvements in sensitivity, selectivity, throughput, qualitative content and many other performance characteristics of high performance liquid chromatography (HPLC). A major need is for methods that provide both universal detection and quantitative analysis. It is widely recognized that no single HPLC detector is capable of distinguishing all possible analytes from a given chromatographic eluent and the term "universal" is often used to describe detection of a diverse range of analytes. A primary goal for most analyses that seek universal detection is to obtain a consistent relationship between the magnitude of response and quantity injected for a range of analytes. This "consistency of response factors" allows the use of global mathematical relationships to estimate quantity (for example, use of parent drug response factor to quantify metabolites and degradants). This characteristic is useful in many applications, where it is impractical or impossible to use individual standards to calibrate the response for each analyte such as drug library QC, pharmaceutical impurity testing, complex lipid analyses and many applications requiring mass balance assessment. Currently, performing such an analysis is difficult with available technologies.
Developments of micro liquid chromatography—mass spectrometry with gradient elution
Journal of Chromatography A, 1989
Fused-silica columns (I.D. 0.22 mm) packed with ordinary small particle liquid chromatographic material were used in direct connection to an electron impact ion source. The electrostatic field between the column end and an extraction-focusing plate, located close to the ion source inlet, was used for nebulization of the solvent. The ion source was modified to obtain higher efficiency and to reduce the thermal decomposition of labile compounds. A system for micro flow gradients (less than 2 pl/min) has been developed. The flow of a pumping medium (glycerol) is divided into two parallel streams and the flow distribution is controlled using the temperature dependence of the viscosity. The glycerol flow is changed by two "media converters" to the chromatographic solvents. Applications of micro liquid chromatography-mass spectrometry are shown for a plant allelochemical, dhurrin, obtained from Sorghum leaf extract. Mass spectra of glucose, sucrose, neral, geranial, chlorsulphuron, myoinositol, 3,5dinitrobenzoic acid, amitriptyline, IO-hydroxyamitriptyline and omeprazole after liquid chromatography are shown.
Instrumentation and Applications of Micro-Liquid Chromatography/Mass Spectrometry
Journal of Chromatography Library, 1985
Chromatography is a separation technique used to separate the individual compound from a mixture using a stationary and mobile phase. Discovery of chromatography is a millstone event in biomedical research. Chromatographic separation is based on the principles of adsorption, partition, ion exchange, molecular exclusion, affinity and Chirality. There are many types of chromatography available for quantitative and qualitative analysis of pharmaceutical agents, which includes Liquid Chromatography-Mass Spectrometry (LC-MS). Combination of chromatography with spectrometry is first reported in 1967 and first LC-MS system was introduced in 1980s. LC-MS is an analytical chemistry technique that combines the physical separation capabilities of liquid chromatography with the mass analysis and mass spectrometry. Mainly the LC-MS contains liquid chromatography assembly, ion generation unit/ ionization source, mass analyzer and mass spectrometric data acquisition. LC-MS is most commonly used in biomedical sciences for pharmacokinetic analysis, genetic analysis, structural elucidation, etc. The main objective of this review is to overview the principle, instrumentation and application of LC-MS.
Rapid Communications in Mass Spectrometry, 1998
An atmospheric pressure chemical ionization liquid chromatography/mass spectrometry (APCI-LC/MS) system was evaluated for the analysis of cholesterol oxidation products (COPs). High performance liquid chromatography separation of these compounds was performed under reversed-phase chromatographic conditions at 1 mL/min flow rate. Useful mass spectra for confirmation and quantitation purposes were obtained with positive-ion detection. The influence of several parameters, such as the temperature of the heated nebulizer interface, the voltage applied to the orifice and to the ring electrode on the mass spectra of the analytes, was studied and optimized in order to obtain the best sensitivity. Linearity, sensitivity and precision of the method were determined operating in the selected-ion monitoring mode. Detection limits were in the range 0.2-0.8 ng for all the compounds with linear calibration graphs in the 0.1-10 mg/L concentration range. The method was applied to the quantitative analysis of COPs in lyophilized beef preparations, and results were compared with those obtained using LC/UV and LC/MS with particle beam interface. #