Diagnostic performance of anti-Zika virus IgM, IgAM and IgG ELISAs during co-circulation of Zika, dengue, and chikungunya viruses in Brazil and Venezuela (original) (raw)
Related papers
2020
Accurate diagnostics underpin effective public health responses to emerging viruses. For viruses, such as Zika virus (ZIKV), where the viremia clears quickly, antibody-based (IgM or IgG) diagnostics are recommended for patients who present seven days after symptom onset. However, cross-reactive antibody responses can complicate test interpretation among populations where closely related viruses circulate.We examined the accuracy (proportion of samples correctly categorized as Zika-positive or negative) for antibody-based diagnostics among Brazilian residents (Rio de Janeiro) during the ZIKV outbreak. Four ZIKV ELISAs (IgM and IgG Euroimmun, IgM Novagnost and CDC MAC), two dengue ELISAs (IgM and IgG Panbio), and the ZIKV plaque reduction neutralization test (PRNT) were evaluated. Positive samples were ZIKV PCR confirmed clinical cases collected in 2015-2016 (n=169); Negative samples (n=236) were collected before ZIKV was present in Brazil (≤2013).Among serum samples collected ≥7 days...
Virology journal, 2018
Serologic detection of Zika virus (ZIKV) infections is challenging because of antigenic similarities among flaviviruses. To evaluate the sensitivity and specificity of commercial ZIKV IgM and IgG enzyme-linked immunoassay (ELISA) kits. We used sera from febrile patients with RT-PCR-confirmed ZIKV infection to determine sensitivity and sera from RT-PCR-confirmed dengue cases and blood donors, both of which were collected before ZIKV epidemics in Brazil (2009-2011 and 2013, respectively) to determine specificity. The ZIKV IgM-ELISA positivity among RT-PCR ZIKV confirmed cases was 0.0% (0/14) and 12.5% (1/8) for acute- and convalescent-phase sera, respectively, while its specificity was 100.0% (58/58) and 98.3% (58/59) for acute- and convalescent-phase sera of dengue patients, and 100.0% (23/23) for blood donors. The ZIKV IgG-ELISA sensitivity was 100.0% (6/6) on convalescent-phase sera from RT-PCR confirmed ZIKV patients, while its specificity was 27.3% (15/55) on convalescent-phase s...
Evaluation of Two Serological Assays for Diagnosing Zika Virus Infection
Diagnostics, 2021
Zika virus (ZIKV) emerged and spread rapidly in South American countries during 2015. Efforts to diagnose ZIKV infection using serological tools were challenging in dengue-endemic areas because of antigenic similarities between both viruses. Here, we assessed the performance of an in-house developed IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and the plaque reduction neutralization test (PRNT) to diagnose ZIKV infection. Acute and convalescent paired serum samples from 51 patients who presented with clinical symptoms suggestive of an arbovirus illness in dengue-endemic areas of Honduras, Venezuela, Colombia and Peru were used in the assessment. Samples were tested for ZIKV, dengue and chikungunya virus using a variety of laboratory techniques. The results for the ZIKV-RNA screening and seroconversion detected by the microneutralization test were used to construct a composite reference standard. The overall sensitivity and specificity for the MAC-ELISA were 93....
The American Journal of Tropical Medicine and Hygiene
Serological cross-reactivity has proved to be a challenge to diagnose Zika virus (ZIKV) infections in dengue virus (DENV) endemic countries. Confirmatory testing of ZIKV IgM positive results by plaque reduction neutralization tests (PRNTs) provides clarification in only a minority of cases because most individuals infected with ZIKV were previously exposed to DENV. The goal of this study was to evaluate the performance of a ZIKV/DENV DUO IgM antibody capture ELISA (MAC-ELISA) for discriminating between DENV and ZIKV infections in endemic regions. Our performance evaluation included acute and convalescent specimens from patients with real-time reverse transcription polymerase chain reaction (RT-PCR)-confirmed DENV or ZIKV from the Sentinel Enhanced Dengue Surveillance System in Ponce, Puerto Rico. The ZIKV/DENV DUO MAC-ELISA specificity was 100% for DENV (N = 127) and 98.4% for ZIKV (N = 275) when specimens were tested during the optimal testing window (days post-onset of illness [DP...
Eurosurveillance, 2016
Serological diagnosis of Zika virus (ZIKV) infections is challenging due to high cross-reactivity between flaviviruses. We evaluated the diagnostic performance of a novel anti-ZIKV ELISA based on recombinant ZIKV non-structural protein 1 (NS1). Assay sensitivity was examined using sera from 27 patients with reverse transcription (RT)-PCR-confirmed and 85 with suspected ZIKV infection. Specificity was analysed using sera from 1,015 healthy individuals. Samples from 252 patients with dengue virus (n = 93), West Nile virus (n = 34), Japanese encephalitis virus (n = 25), chikungunya virus (n = 19) or Plasmodium spp. (n = 69) infections and from 12 yellow fever-vaccinated individuals were also examined. In confirmed ZIKV specimens collected ≥ 6 days after symptom onset, ELISA sensitivity was 58.8% (95% confidence interval (CI): 36.0–78.4) for IgM, 88.2% (95% CI: 64.4–98.0) for IgG, and 100% (95% CI: 78.4–100) for IgM/IgG, at 99.8% (95% CI: 99.2–100) specificity. Cross-reactivity with hig...
Diagnostics
Serological diagnosis of Zika virus (ZIKV) infection is challenging because of antigenic cross-reactivity with dengue virus (DENV). This study evaluated the accuracy of the Zika IgM antibody capture enzyme-linked immunosorbent assay (CDC Zika IgM MAC-ELISA) in differentiating between ZIKV and DENV infections. To determine sensitivity, we used acute- and convalescent-phase sera from 21 patients with RT-PCR-confirmed ZIKV infection. To determine specificity, we used acute- and convalescent-phase sera from 60 RT-PCR-confirmed dengue cases and sera from 23 blood donors. During the acute-phase of the illness, the assay presented a sensitivity of 12.5% (2/16) for samples collected 0–4 days post symptoms onset (DPSO), and of 75.0% (3/4) for samples collected 5–9 DPSO. During the convalescent-phase of the illness, the test sensitivity was 90.9% (10/11), 100% (2/2), and 0% (0/2) for samples obtained 12–102, 258–260, and 722–727 DPSO, respectively. Specificity for acute- and convalescent-phas...
Antibody-based assay discriminates Zika virus infection from other flaviviruses
Zika virus (ZIKV) is a mosquito-borne flavivirus that emerged recently as a global health threat, causing a pandemic in the Americas. ZIKV infection mostly causes mild disease, but is linked to devastating congenital birth defects and Guillain-Barré syndrome in adults. The high level of cross-reactivity among flaviviruses and their cocircula-tion has complicated serological approaches to differentially detect ZIKV and dengue virus (DENV) infections, accentuating the urgent need for a specific and sensitive serological test. We previously generated a ZIKV nonstructural protein 1 (NS1)-specific human monoclo-nal antibody, which we used to develop an NS1-based competition ELISA. Well-characterized samples from RT-PCR-confirmed patients with Zika and individuals exposed to other flavivirus infections or vaccination were used in a comprehensive analysis to determine the sensitivity and specificity of the NS1 blockade-of-binding (BOB) assay , which was established in laboratories in five countries (Nicara-gua, Brazil, Italy, United Kingdom, and Switzerland). Of 158 sera/ plasma from RT-PCR-confirmed ZIKV infections, 145 (91.8%) yielded greater than 50% inhibition. Of 171 patients with primary or secondary DENV infections, 152 (88.9%) scored negative. When the control group was extended to patients infected by other flaviviruses, other viruses, or healthy donors (n = 540), the specificity was 95.9%. We also analyzed longitudinal samples from DENV-immune and DENV-naive ZIKV infections and found inhibition was achieved within 10 d postonset of illness and maintained over time. Thus, the Zika NS1 BOB assay is sensitive, specific, robust, simple, low-cost, and accessible , and can detect recent and past ZIKV infections for surveillance, seroprevalence studies, and intervention trials. Zika | serology | flaviviruses | dengue | ELISA
Comparison of four serological methods and two RT-PCR assays for diagnosis and surveillance of Zika
Journal of clinical microbiology, 2018
Zika virus (ZIKV) is a mosquito-borne flavivirus that is responsible for recent explosive epidemics in the Americas. Notably, ZIKV infection during pregnancy has been found to cause congenital birth defects, including microcephaly, and ZIKV has been associated with Guillain Barré Syndrome in adults. Diagnosis and surveillance of Zika in the Americas have been challenging due to similar clinical manifestations and extensive antibody cross-reactivity with endemic flaviviral diseases, like dengue. We evaluated four serological and two RT-PCR methods in acute (mean day 1.8), early convalescent (mean day 16.7), and late convalescent (∼7 months) samples from the same individuals in a long-term pediatric cohort study in Nicaragua. Well-characterized samples from 301 cases of Zika, dengue, or non-Zika, non-dengue febrile illnesses were tested. Compared to a composite reference, an in-house MAC-ELISA and the NIAID-BEI MAC-ELISA measuring IgM yielded sensitivities of 94.5% and 70.1% and speci...
The American Journal of Tropical Medicine and Hygiene
Zika virus (ZIKV) serological diagnostics are compromised in areas where dengue viruses (DENV) cocirculate because of their high levels of protein sequence homology. Here, we describe the characterization of a Zika blockade-of-binding ELISA (Zika BOB) and a Zika microneutralization assay (Zika MN) for the detection of ZIKV nonstructural protein 1 (NS1)-specific antibodies and ZIKV neutralizing antibodies, respectively. Zika BOB and Zika MN cutoffs were established as 10 and 100 endpoint titers, respectively, using samples collected pre-and post-virologically confirmed ZIKV infection from subjects living in DENV-endemic areas. Specificity of the assays was equally high, whereas sensitivity of Zika BOB was lower than that of Zika MN, especially in samples collected > 6 months post-infection. Immunosurveillance analysis, using combined results from both Zika BOB and Zika MN, carried out also in DENVendemic regions in Colombia, Honduras, Mexico, and Puerto Rico before (2013-2014) and after (2017-2018) ZIKV introduction in the Americas suggests unapparent ZIKV seroprevalence rates ranged from 25% to 80% over the specified period of time in the regions investigated.
Journal of Clinical Microbiology, 2017
Serologic evaluation for Zika virus (ZIKV) infection currently includes an initial screen using an anti-ZIKV IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) followed by supplemental testing of specimens with nonnegative results by a plaque reduction neutralization test (PRNT). We compared the performance characteristics of three ELISAs for the detection of IgM class antibodies to ZIKV, including the Centers for Disease Control and Prevention (CDC) Zika MAC-ELISA, the InBios ZIKV Detect MAC-ELISA, and the Euroimmun anti-Zika Virus IgM ELISA. Additionally, we present our initial experiences with ZIKV serologic testing from a national reference laboratory perspective. Using both retrospectively and prospectively collected specimens from patients with possible ZIKV infection, we show that the CDC and InBios MAC-ELISAs perform comparably to each other, with positive agreement, negative agreement, and interrater kappa values ranging from 87.5% to 93.1%, 95.7% to 98.5%, ...