Utility of Asthma Control Questionnaire 7 in the assessment of asthma control (original) (raw)
Related papers
Our objective was to evaluate the reproducibility of Asthma Control Questionnaire 7 (ACQ-7) in asthma patients, comparing our results against those obtained with the Global Initiative for Asthma (GINA) criteria. We evaluated 52 patients. Patients completed the ACQ-7, underwent spirometry, and were clinically assessed to determine the level of asthma control according to the GINA criteria, in two visits, 15 days apart. The ACQ-7 cutoff for uncontrolled asthma was a score of 1.5. The ACQ-7 showed good reproducibility, with a correlation coefficient of 0.73. The ACQ-7 identified a greater number of patients with uncontrolled asthma than did the GINA criteria; according to the GINA criteria, 47 patients (90.4%) presented with partially controlled asthma.
Development of the asthma control test☆A survey for assessing asthma control
Journal of Allergy and Clinical Immunology, 2004
Background: Asthma guidelines indicate that the goal of treatment should be optimum asthma control. In a busy clinic practice with limited time and resources, there is need for a simple method for assessing asthma control with or without lung function testing. Objectives: The objective of this article was to describe the development of the Asthma Control Test (ACT), a patient-based tool for identifying patients with poorly controlled asthma. Methods: A 22-item survey was administered to 471 patients with asthma in the offices of asthma specialists. The specialist's rating of asthma control after spirometry was also collected. Stepwise regression methods were used to select a subset of items that showed the greatest discriminant validity in relation to the specialist's rating of asthma control. Internal consistency reliability was computed, and discriminant validity tests were conducted for ACT scale scores. The performance of ACT was investigated by using logistic regression methods and receiver operating characteristic analyses. Results: Five items were selected from regression analyses. The internal consistency reliability of the 5-item ACT scale was 0.84. ACT scale scores discriminated between groups of patients differing in the specialist's rating of asthma control (F = 34.5, P < .00001), the need for change in patient's therapy (F = 40.3, P < .00001), and percent predicted FEV 1 (F = 4.3, P = .0052). As a screening tool, the overall agreement between ACT and the specialist's rating ranged from 71% to 78% depending on the cut points used, and the area under the receiver operating characteristic curve was 0.77. Conclusion: Results reinforce the usefulness of a brief, easy to administer, patient-based index of asthma control. (J Allergy Clin Immunol 2004;113:59-65.)
Respiratory medicine, 2006
The 7-item Asthma Control Questionnaire (ACQ) has been validated to measure the goals of asthma management as defined by international guidelines (minimisation of day- and night-time symptoms, activity limitation, beta(2)-agonist use and bronchoconstriction). Responses are given on a 7-point scale and the overall score is the mean of the responses (0=totally controlled, 6=severely uncontrolled). The aim of this analysis was to determine the cut-point on the ACQ that best differentiates between 'well-controlled' and 'not well-controlled' for (a) clinical practice (low risk of missing 'not well-controlled') and (b) clinical trials (low risk of including 'well-controlled'). All 1323 patients who provided data sets at week 12 in the Gaining Optimal Asthma Control (GOAL) clinical trial were included in the analysis. The gold standard for 'well-controlled' was a composite based on the GINA/NIH guidelines and derived from data collected in the clinic...
Objective: To evaluate whether the Portuguese version of the Asthma Control Questionnaire (ACQ) is a valid instrument to measure asthma control in adult outpatients in Brazil. Methods: We selected 278 outpatients diagnosed with asthma. All of the patients completed the questionnaire, underwent spirometry and were clinically evaluated by a physician in order to characterize the control of the disease in the first visit. The questionnaire was evaluated in three versions, with 5, 6 and 7 questions, respectively, and scores of 0.75 and 1.50 were used as cut-off points. Results: Of the 278 patients, 77 (27.7%) had intermittent asthma, 39 (14.0%) had mild persistent asthma, 40 (14.4%) had moderate persistent asthma and 122 (43.9%) had severe persistent asthma. The sensitivity of ACQ to identify uncontrolled asthma ranged from 77% to 99%, and the specificity ranged from 36% to 84%. The positive predictive value ranged from 73% to 90%, and the negative predictive value ranged from 67% to 95%. The positive likelihood ratio ranged from 1.55 to 4.81, and the negative likelihood ratio ranged from 0.03 to 0.27. In the 5-and 6-question versions of the ACQ, the intraclass correlation coefficient was 0.92. These two versions were both responsive to clinical changes in the patients. Conclusions: All three versions of the ACQ satisfactorily discriminated between patients with uncontrolled asthma and those with controlled asthma. The 5-and 6-question versions also presented good reliability and responsiveness. Therefore, the ACQ is a valid tool for evaluating asthma control in adult outpatients in Brazil.
Journal of Asthma, 2020
Objective: To assess whether the content of the Asthma Control Test (ACT) served as a valid measure of asthma control (i.e., content validity) by mapping ACT items to the National Heart, Lung and Blood Institute (NHLBI) guideline asthma control definitions, and to language used by patients to describe their asthma. Data sources: PubMed and EMBASE databases were used for a structured literature analysis. Study selections: Full-text, English-language articles that reported findings from qualitative studies conducted in adults, focusing on patient descriptors of asthma symptoms, impacts, or severity, were included. Pediatric studies, studies conducted in patients without asthma, and studies that did not contain qualitative data were excluded. Results: ACT items reflected all domains of asthma impairment described in the NHLBI guidelines, except pulmonary function. Following the literature review, 28 full-text publications were identified that included patient descriptors that could be mapped to ACT items. For example, per ACT Item 1, patients described having trouble at work, school, and completing household chores; and, per ACT Item 2, patients used the phrase "short of breath" to describe asthma-associated symptoms. Conclusion: ACT item content corresponded well with the NHLBI guideline definitions of the impairment domain of asthma control (focused on asthma symptoms and impact), and we identified numerous examples in the literature indicating that ACT concepts and item content mirror the language patients use when discussing asthma symptoms and impact, and their degree of asthma control. This provides further evidence to support content validity of the ACT as a measure of asthma control.
Comparison of doctor and patient assessments of asthma control
Respiratory Medicine, 2010
The objective of asthma management is to control the condition. However, world-wide surveys reveal that only 5% of asthmatics are well controlled. One reason for this phenomenon is the fact that patients and doctors consistently over-estimate control. This study compared patient and doctor assessment of asthma control.