Current focussing in cochlear implants: An analysis of neural recruitment in a computational model (original) (raw)

Current focusing sharpens local peaks of excitation in cochlear implant stimulation

David Landsberger

Hearing Research, 2010

View PDFchevron_right

Stimulation strategies and electrode design in computational models of the electrically stimulated cochlea: An overview of existing literature

Jeroen Briaire

Network: Computation in Neural Systems, 2016

View PDFchevron_right

Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents

Andrej Kral

Hearing Research, 1998

View PDFchevron_right

Probing the Electrode-Neuron Interface With Focused Cochlear Implant Stimulation

Julie Bierer

2010

View PDFchevron_right

Current Distributions in Cochlear Stimulation

J. Patrick

Annals of the New York Academy of Sciences, 1983

View PDFchevron_right

Modeling the electrode–neuron interface of cochlear implants: Effects of neural survival, electrode placement, and the partial tripolar configuration

Julie Bierer

Hearing Research, 2010

View PDFchevron_right

Modeling potential distributions inside the cochlea caused by electrical stimulation

Andras Katai

2013

View PDFchevron_right

Spread of Excitation and Channel Interaction in Single- and Dual-Electrode Cochlear Implant Stimulation

J. Frijns

Ear & Hearing, 2012

View PDFchevron_right

Numerical Modeling and Experimental Measurements of the Electric Potential Generated by Cochlear Implants in Physiological Tissues

Sandro Burdo, A. Pesatori

IEEE Transactions on Instrumentation and Measurement, 2007

View PDFchevron_right

Place pitch versus electrode location in a realistic computational model of the implanted human cochlea

J. Frijns

Hearing Research, 2014

View PDFchevron_right

Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea

J. Frijns

Hearing Research, 1996

View PDFchevron_right

Auditory cortical images of cochlear-implant stimuli: coding of stimulus channel and current level

Julie Bierer

Journal of Neurophysiology, 2002

View PDFchevron_right

Reducing current spread using current focusing in cochlear implant users

David Landsberger

Hearing Research, 2012

View PDFchevron_right

Auditory Cortical Images of Cochlear-Implant Stimuli: Dependence on Electrode Configuration

Julie Bierer

Journal of Neurophysiology, 2002

View PDFchevron_right

Cortical Responses to Cochlear Implant Stimulation: Channel Interactions

Julie Bierer

JARO - Journal of the Association for Research in Otolaryngology, 2004

View PDFchevron_right

Field patterns in a 3D tapered spiral model of the electrically stimulated cochlea

Jeroen Briaire

Hearing Research, 2000

View PDFchevron_right

Current Focusing to Reduce Channel Interaction for Distant Electrodes in Cochlear Implant Programs

Julie Arenberg

Trends in Hearing, 2018

View PDFchevron_right

Measurements of Generated Potentials by the Electrodes of a Cochlear Implant

Sandro Burdo

2007 IEEE International Workshop on Medical Measurement and Applications, 2007

View PDFchevron_right

Integrated use of volume conduction and neural models to simulate the response to cochlear implants

Jeroen Briaire

Simulation Practice and Theory, 2000

View PDFchevron_right

Direct current measurements in cochlear implants: an in vivo and in vitro study

Bruce Tabor

Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269), 1998

View PDFchevron_right

Virtual channel discrimination is improved by current focusing in cochlear implant recipients

David Landsberger

Hearing Research, 2009

View PDFchevron_right

Effects of Electrode Position on Spatiotemporal Auditory Nerve Fiber Responses: A 3D Computational Model Study

Tanmoy Chowdhury

Computational and Mathematical Methods in Medicine, 2015

View PDFchevron_right

Estimation of stimulus attenuation in cochlear implants

Jacoba Smit

Journal of Neuroscience Methods, 2009

View PDFchevron_right

Current Distribution Measurements Within the Human Cochlea

J. Patrick

IEEE Transactions on Biomedical Engineering, 2000

View PDFchevron_right

Simultaneous and non-simultaneous dual electrode stimulation in cochlear implants: evidence for two neural response modalities

J. Frijns

Acta Oto-Laryngologica, 2009

View PDFchevron_right

Spatial distribution of neural activity evoked by electrical stimulation of the cochlea

Nigel Woolf

Hearing Research, 1990

View PDFchevron_right

Cochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array

Arun Badi MD PhD

Otology & Neurotology, 2003

View PDFchevron_right

Effects of stimulus level on electrode-place discrimination in human subjects with cochlear implants

T. Zwolan

Hearing Research, 1999

View PDFchevron_right

An Instrumented Cochlea Model for the Evaluation of Cochlear Implant Electrical Stimulus Spread

Iwan Roberts

IEEE Transactions on Biomedical Engineering, 2021

View PDFchevron_right

Validation of a Cochlear Implant Dead Region Model Using Monopolar and Tripolar Threshold Data

Julie Bierer

View PDFchevron_right

Phenomenological model of auditory nerve population responses to cochlear implant stimulation

Norbert Dillier

Journal of Neuroscience Methods, 2021

View PDFchevron_right

Perceptual Interactions Between Electrodes Using Focused and Monopolar Cochlear Stimulation

Colette McKay

Journal of the Association for Research in Otolaryngology, 2015

View PDFchevron_right

Signal Processing Strategies for Cochlear Implants Using Current Steering

Leonid Litvak

EURASIP Journal on Advances in Signal Processing, 2009

View PDFchevron_right

Measurement of electrode current pulses from cochlear implants

Sandro Burdo

IEEE Transactions on Instrumentation and Measurement, 2005

View PDFchevron_right