Transient Simulation of a Transcritical Carbon Dioxide Refrigeration System (original) (raw)
Related papers
Modeling and Simulation of Refrigeration Systems with the Natural Refrigerant CO 2
2002
This papers presents the current results of the development of a ModelicaTM library for CO2-Refrigeration systems based on the free Modelica library ThermoFluid. The development of the library is carried out in a research project of EADS Airbus and the TUHH and is focused on the aim to get a library for detailed numerical investigations of refrigeration systems with the rediscovered, natural refrigerant carbon dioxid (CO2). A survey of the CO2-Library is given and the modeling of CO2-Heat exchangers is described in detail. A comparison with steady state results of heat exchangers is presented and results of a transient simulation run are discussed with respect to plausibility.
Description and validation of a computer based refrigeration system simulator
Computers and Electronics in Agriculture, 2012
This paper describes and evaluates the validation of a novel software package which simulates the transient and steady-state operation of whole refrigeration systems of the type used for the storage and processing of food. This software allows practitioners to study the implications of design choices in terms of energy usage and carbon generation in the storage and processing of food stuff by refrigeration. The software can also provide refrigeration system owners and designers with information on how a system's energy consumption might be reduced.
Dynamic Modeling and Validation of a Carbon Dioxide Heat Pump System
Evergreen, 2020
The objective of the present manuscript is to develop a dynamic model to simulate the transient performance of a heat pump system that utilizes environmental-friendly refrigerant, Carbon Dioxide (R-744). Exploiting the high customizability of the modeling tools supporting acausal, equation-based, and object-oriented modeling approach, a dynamic model for a transcritical heat pump system was developed. The model was validated with the experimental results with particular attention to the refrigerant mass flow rate, cooling/heating capacity, compressor power, and the coefficient of performance.
Energetic and exergetic studies of modified CO2 transcritical refrigeration cycles
International Journal of Low-Carbon Technologies, 2020
Thermodynamic analysis including energetic and exergetic analysis is carried out employing Engineering Equation Solver for the five modified cycles: dual expansion cycle, internal heat exchanger cycle, work recovery cycle, work recovery with internal heat exchanger cycle and vortex tube expansion cycle. Contours are developed to study the effect of gas cooler temperatures and evaporator temperatures on the system performance and optimum gas cooler pressure. The modified cycle with work recovery turbine offers relatively higher COP and higher exergetic efficiency with lower compressor discharge pressure. The exergy loss in compressor, gas cooler, throttle valve and vortex tube (VT) are considerably higher than that in internal heat exchanger (IHX), evaporator and turbine. It is observed that COP of modified cycle with VT is slightly less than that with IHX, whereas the cycle with work recovery turbine brings the highest COP with the improvement of 25% at the gas cooler exit temperatu...
Implementation of a modelica library for simulation of refrigeration systems
The physical modelling and transient simulation of refrigeration systems can be useful within the spec-ification, development, integration and optimisation. Therefore, a model library for vapour compression cy-cles has been implemented. The library is based on the free Modelica library ThermoFluid and contains basic correlations for heat and mass transfer and pres-sure drop, partial components for control volumes and flow resistances and advanced ready-to-use models for all relevant components of refrigeration systems like pipes, heat exchangers, compressor, expansion devices and accumulator. The library currently enables the use of two refrigerants (CO 2 , R134a), but due to the struc-ture of the library the extension to other refrigerant medium models is quite easy to realise. The modelling approach, the structure of the library and some valida-tion results are presented in this paper.
International Journal of Refrigeration-revue Internationale Du Froid, 2007
Analysis of an endoreversible two-stage cascade cycle has been implemented and optimum intermediate temperature for maximum exergy and refrigeration effect have been obtained analytically. Further, the heat reservoir temperatures has been optimised independently. A comprehensive numerical model of a transcritical CO 2 eC 3 H 8 cascade system was developed with intent to verify the theoretical results. It is seen that the simulation results agree well for optimal T L but deviate modestly from the theoretical optimum of T H . It has also been observed that system performance improves as T H increases and unlike theoretical predictions, no optimal T H is present within feasible working temperatures.
Applied Energy, 2010
Carbon dioxide is an interesting solution for commercial refrigeration and in perspective for air-conditioning systems. In this paper a newly developed carbon dioxide transcritical air cooled chiller for refrigerating propylene glycol down to À8°C supply temperature is described. The aim of the project was at optimising the cycle energy efficiency while assuring reliable operation and simple management of the unit. The carbon dioxide optimal pressure issue is addressed with an innovate system architecture and control logic. Using a flash tanks and two electronic valves, the optimal cycle upper pressure was maintained in transcritical operation mode. The managing of the valves allows the refrigeration machine efficiency improvement when the gas cooler inlet air allows subcritical working conditions. A simulation model of the chiller was developed and its results validated with experimental data. A measurement campaign was carried out, testing the chiller at external temperatures ranging from 18 to 35°C, the unit energy efficiency ranging from 3.1 to 2.0.
2021
With increasing awareness of the adverse effects of carbon emissions on the environment, researchers within the heating, ventilation, air conditioning, and refrigeration (HVAC&R) community have been pushing for lower global warming potential (GWP) and natural working fluids as well as systems that are more efficient than the higher-GWP systems they replace. One such working fluid is carbon dioxide (CO2). While CO2 has the advantages of being lowcost, non-flammable, and possessing a high volumetric heat capacity, it has a high critical pressure associated with a low critical temperature, thus often necessitating transcritical operation that requires significant compressor input power. As such, numerous cycle modifications have been proposed that enable the transcritical CO 2 cycle to match, and in some cases surpass, the coefficient of performance (COP) of existing hydrofluorocarbon (HFC) cycles under the same operating conditions. This work provides an experimental comparison of four cycle architectures that utilize the same compressors and heat exchangers. This enables a meaningful comparison of these modifications, consisting of open economization with an evaporator bypass, as well as both electronic expansion valve (EXV) and ejector expansion strategies, along with a pump applied between the gas cooler outlet and the ejector motive nozzle inlet for control and increased recoverable pressure differential. Experimental parametric studies were conducted, and comparisons of architecture costs and benefits are presented. Design recommendations are provided along with future work.