Markerless Camera System vs. Marker Based System: Which is the most repeatable? (original) (raw)
Related papers
Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software
BioMed research international, 2018
The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information ...
Enhancing the Measurement of Clinical Outcomes Using Microsoft Kinect
2016 International Conference on Interactive Technologies and Games (ITAG), 2016
There is a growing body of applications leveraging Microsoft Kinect and the associated Windows Software Development Kit in health and wellness. In particular, this platform has been valuable in developing interactive solutions for rehabilitation including creating more engaging exercise regimens and ensuring that exercises are performed correctly for optimal outcomes. Clinical trials rely upon robust and validated methodologies to measure health status and to detect treatment-related changes over time to enable the efficacy and safety of new drug treatments to be assessed and measured. In many therapeutic areas, traditional outcome measures rely on subjective investigator and patient ratings. Subjective ratings are not always sensitive to detecting small improvements, are subject to inter-and intra-rater variability and limited in their ability to record detailed or subtle aspects of movement and mobility. For these reasons, objective measurements may provide greater sensitivity to detect treatment-related changes where they exist. In this review paper, we explore the use of the Kinect platform to develop low-cost approaches to objectively measure aspects of movement. We consider published applications that measure aspects of gait and balance, upper extremity movement, chest wall motion and facial analysis. In each case, we explore the utility of the approach for clinical trials, and the precision and accuracy of estimates derived from the Kinect output. We conclude that the use of games platforms such as Microsoft Kinect to measure clinical outcomes offer a versatile, easy to use and low-cost approach that may add significant value and utility to clinical drug development, in particular in replacing conventional subjective measures and providing richer information about movement than previously possible in large scale clinical trials, especially in the measurement of gross spatial movements. Regulatory acceptance of clinical outcomes collected in this way will be subject to comprehensive assessment of validity and clinical relevance, and this will require good quality peer-reviewed publications of scientific evidence.
Journal of Medical Engineering & Technology
Human motion tracking is widely used for assessment of movement dysfunction in orthopaedic patients. Currently, most clinical motion analysis centres use marker based three-dimensional (3D) systems as they are deemed to be the most accurate method. However, due to space, costs and logistics they are not available in many clinical settings. This study compared joint angles measured in functional tests using the novel low-cost Microsoft Kinect Perfect Phorm system with the established marker based Nexus VICON system. When measuring right and left knee flexion, the average difference between the VICON and Kinect Perfect Phorm measurement was 13.2%, with a SD of 19.6. Both overestimation and underestimation of the joint angle was recorded in different participants. Although the average percentage difference during hip abduction tests was lower at-3.9%, the range of error was far greater (SD=75). From this, it can be concluded that the level of accuracy presented in the new low cost Kinect Perfect Phorm system is not yet suitable for clinical assessments. However, for general tests of performance, and for tracking cases where absolute accuracy is less critical, future versions of this software may have a place.
Improving between-day kinematic reliability using a marker placement device
Journal of Orthopaedic Research, 2010
3D motion analysis is commonly used to measure clinical outcomes, involving repeated measures over time. However, the day-to-day reliability of these measurements has been questioned and few attempts have been made to improve this reliability. Our purpose was to determine if a marker placement device (MPD) could improve day-to-day kinematic reliability as compared to manual marker placement. Ten healthy runners participated. Day-to-day comparisons of peak angles were made between manual marker placement and the use of an MPD. Reliability of each method was determined with intraclass correlation coefficients (ICC) and standard errors of measurement (SEM). The ICC and SEM values improved with the MPD. With the MPD, 7 out of 9 ICC values were >0.9 compared to only 3 when using manual marker placement. Additionally, the largest reduction in SEM values was in the transverse plane. Use of the MPD increases the power to detect smaller differences in studies of where gait is assessed over time. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1405–1410, 2010
BioMedical Engineering OnLine, 2015
Using virtual reality systems for stroke rehabilitation is a flourishing field in physical and neurological rehabilitation. Such systems can help patients have a more intensive and entertaining training. They are commonly composed of a sensory device to capture the patient's movements, and a computer interface to communicate with the patient and Abstract Background: Performance indices provide quantitative measures for the quality of motion, and therefore, assist in analyzing and monitoring patients' progress. Measurement of performance indices requires costly devices, such as motion capture systems. Recent developments of sensors for game controllers, such as Microsoft Kinect, have motivated many researchers to develop affordable systems for performance measurement applicable to home and clinical care. In this work, the capability of Kinect in finding motion performance indices was assessed by analyzing intra-session and intersession test-retest reliability.
Sensors (Basel, Switzerland), 2021
Advancements in motion sensing technology can potentially allow clinicians to make more accurate range-of-motion (ROM) measurements and informed decisions regarding patient management. The aim of this study was to systematically review and appraise the literature on the reliability of the Kinect, inertial sensors, smartphone applications and digital inclinometers/goniometers to measure shoulder ROM. Eleven databases were screened (MEDLINE, EMBASE, EMCARE, CINAHL, SPORTSDiscus, Compendex, IEEE Xplore, Web of Science, Proquest Science and Technology, Scopus, and PubMed). The methodological quality of the studies was assessed using the consensus-based standards for the selection of health Measurement Instruments (COSMIN) checklist. Reliability assessment used intra-class correlation coefficients (ICCs) and the criteria from Swinkels et al. (2005). Thirty-two studies were included. A total of 24 studies scored “adequate” and 2 scored “very good” for the reliability standards. Only one s...
Journal of NeuroEngineering and Rehabilitation, 2023
Background Markerless motion capture (MMC) technology has been developed to avoid the need for body marker placement during motion tracking and analysis of human movement. Although researchers have long proposed the use of MMC technology in clinical measurement-identification and measurement of movement kinematics in a clinical population, its actual application is still in its preliminary stages. The benefits of MMC technology are also inconclusive with regard to its use in assessing patients' conditions. In this review we put a minor focus on the method's engineering components and sought primarily to determine the current application of MMC as a clinical measurement tool in rehabilitation.
Gait & Posture, 2009
During the last decade markerless motion capture techniques have gained an increasing interest in the biomechanics community. In the clinical field, however, the application of markerless techniques is still debated. This is mainly due to a limited number of papers dedicated to the comparison with the state of the art of marker based motion capture, in term of repeatability of the three dimensional joints' kinematics. In the present work the application of markerless technique to data acquired with a marker-based system was investigated. All videos and external data were recorded with the same motion capture system and included the possibility to use markerless and marker-based methods simultaneously. Three dimensional markerless joint kinematics was estimated and compared with the one determined with traditional marker based systems, through the evaluation of root mean square distance between joint rotations. In order to compare the performance of markerless and marker-based systems in terms of clinically relevant joint angles estimation, the same anatomical frames of reference were defined for both systems. Differences in calibration and synchronization of the cameras were excluded by applying the same wand calibration and lens distortion correction to both techniques. Best results were achieved for knee flexion-extension angle, with an average root mean square distance of 11.75 deg, corresponding to 18.35% of the range of motion. Sagittal plane kinematics was estimated better than on the other planes also for hip and ankle (root mean square distance of 17.62 deg e.g. 44.66%, and 7.17 deg e.g. 33.12%), meanwhile estimates for hip joint were the most incorrect. This technique enables users of markerless technology to compare differences with marker-based in order to define the degree of applicability of markerless technique.