EXPERIMENTAL STUDY ON BEHAVIOR OF REINFORCED CONCRETE BEAM SUBJECTED TO CYCLIC LOADING (original) (raw)
Related papers
MATEC Web of Conferences
Structures are expected to have ductile behavior under major earthquakes. One requirement to achieve this ductile behavior is when the structures have no shear failures in their elements. This paper discusses a new method by using the embedded steel truss in the flexural plastic hinges of beam to avoid shear failure. As already known that the shear strength provided by the concrete will be decreased when the ductility of flexural plastic hinges develop in a member. Therefore, a conservative procedure by ignoring the role of concrete in flexural plastic hinges in resisting the shear demand is adopted by some codes. This will increase the demand for shear reinforcement provided by the stirrup or transverse reinforcement in the plastic hinge; yet it still does not ensure that the shear failure does not come to happen. From the laboratory test results under cyclic loading in this study, it can be noted that the beam with embedded steel truss in the plastic hinge has better hysteretic be...
Cyclic Flexural Behavior of Reinforced Concrete Beams
E3S Web of Conferences
The present study aims at investigating the cyclic flexural behavior of reinforced concrete beams with varying depths. Five reinforced concrete beams with beam depth ranging from 250 mm to 750 mm were tested under reversed cyclic loading and the influence of beam depth on the flexural strength and ductility of reinforced concrete beams was investigated. In addition, OpenSees was used to model the test specimens and the analytical results were compared with the experimental reuslts. It is shown that there is no apparent size effect on the normalized ultimate flexural strength of the tested beams, while for the displacement ductility factor, a significant size effect is observed. Load-deflection hysteric curves of test specimens obtained by the fiber-based element of OpenSees with Concrete03 and Hysteric models are in good agreement with those from experimental tests.
Theoretical and numerical analysis of reinforced concrete beams with confinement reinforcement
Revista IBRACON de Estruturas e Materiais, 2008
This paper discusses the use of confinement in over-reinforced concrete beams. This reinforcement consists of square stirrups, placed in the compression zone of the beam cross-section, in order to improve its ductility. A parametric numerical study is initially performed, using a finite element computational program that considers the material nonlinearities and the confinement effect. To investigate the influence of the transverse reinforcing ratio on the beam ductility, an experimental program was also conducted. Four over-reinforced beams were tested; three beam specimens with additional transverse reinforcement to confine the beams, and one without it. All specimens were fabricated with a concrete designed for a compressive strength of 25 MPa. The experimental results show that the post-peak ductility factor is proportional to the confining reinforcement ratio, however the same is not observed for the pre-peak ductility factor, which varied randomly with changes in the confining...
Magazine of Concrete Research, 2004
Compared with normal concrete, high-strength concrete has higher strength but is generally more brittle. Its use in a reinforced concrete structure, if not properly controlled, could lead to an unsustainable reduction in ductility. However, confinement could be provided to improve the ductility of the structure. In this study, the effects of concrete strength and confinement on the flexural ductility of reinforced concrete beams have been evaluated by means of complete moment–curvature analysis of beam sections cast in different concretes and provided with different confinements. The results reveal that the use of high-strength concrete at a constant tension steel ratio would increase the flexural ductility, but at a constant tension to balanced steel ratio would decrease the flexural ductility. In contrast, the provision of confinement would always increase the flexural ductility. It does this in two ways: first, it increases the balanced steel ratio so that, at the same tension st...
Reinforced concrete beams under cyclic loads
1994
An experimental and analytical study program was carried out to investigate the behaviour of reinforced concrete beams subjected to cyclic loadings which incorporated a softening region. The study focused on vibrational characteristics of which softening is the post-elastic behaviour of the critical region in reinforced concrete members which takes place simultaneously at advanced curvature and decreasing moment capacity. Cyclic loadings resulting from earthquake motions include repeated or reversed loads; however, this investigation was restricted to repeated loadings. The analytical behaviour of dynamic elements was conceived with the use of slope-deflection method (Kolousek, 1938); and the advantages of the frequency functions made possible to evaluate natural frequency, deflection due to a dynamic load, dynamic shear force and normal force. In addition to analytical phase, the response of the specimen was analysed using high-quality computer software program, ALGOR. The program ...
Analysis of Confinement Effect on Strength and Ductility in Reinforced Concrete Structures
2014
The lateral confinement in reinforced concrete structural components is an essential parameter to allow designer to use a sufficient percentage of transverse reinforcement in order to ensure the required strength and ductility for the structure. This paper deals mainly with the influence of lateral confinement on strength and ductility in reinforced concrete structures designed according to Algerian standards. An overview of the non-linear static analysis method is described below to better understand this analysis. Two different representative structures designed according to Algerian code for the design of earthquake resistant buildings (RPA99/v2003) are identified for the purpose of this study. This analysis provides the capacity curves for each structure with regard to the compressive strength and the volume percentage of the transverse reinforcement. The results obtained show that the lateral confinement improves widely the strength and the local ductility of the structure elem...
Strength deterioration of reinforced concrete beam–column joints subjected to cyclic loading
Engineering Structures, 2009
This paper proposes a method to predict the ductile capacity of reinforced concrete beam-column joints failing in shear after the development of plastic hinges at both ends of the adjacent beams. After the plastic hinges occur at both ends of the beams, the longitudinal axial strain at the center of the beam section in the plastic hinge region is expected to increase abruptly because the neutral axis continues to move toward the extreme compressive fiber and the residual strains of the longitudinal bars continue to increase with each cycle of additional inelastic loading cycles. An increase in the axial strain of the beam section after flexural yielding contributes to a widening of the cracks in the beam-column joints, thus leading to a reduction in the shear strength of the beam-column joints. The proposed method includes the effect of longitudinal axial strain of a beam in the plastic hinge region of the beam on the joint longitudinal strain and the strength deterioration of the joint. In order to verify the shear strength and the corresponding deformability of the proposed method, test results of RC beam-column assembly were compared. Comparisons between the observed and calculated shear strengths and their corresponding deformability of the tested assemblies showed reasonable agreement.
Analytical Model for Unconfined and Confined High Strength Concrete Under Cyclic Loading
A previously proposed model for uniaxial loading of confined high strength concrete (HSC) is extended in this paper to include cyclic loading. Parameters such as, compressive strength, volumetric ratio of transverse reinforcement, yield strength of ties, tie spacing, and tie pattern, dissipation of energy through the hysteresis loops, stiffness degradation as damage progresses, degree of confinement, and ductility are all taken into account. Comparison of the results from finite element analysis using ADAPTIC, in which the proposed material model is implemented, against experimental results demonstrated good agreement, thus paving the way for much needed parametric studies on the behavior of structures made of HSC.
Nucleation and Atmospheric Aerosols, 2017
This research is to investigate the behaviour of overbalanced High Strength Reinforced Concrete Beams with the compression zone confined with spiral / helical steel reinforcements. The study covered beam behaviour with respect to flexural strength, shear strength, deflection and cracking related to confined concrete. Six 200mm (width) X 300mm (depth) X 3000mm (length) Reinforced Concrete (RC) Beams, the first three beams incorporating steel ratio of 1.42ρb and the remaining 1.64ρb were tested under a four point static load test. The confinement of the concrete was carried out using spiral reinforcements of diameter 6mm and yield stress of 406N/mm2 with pitches of 50mm and 100mm. Measurements of deflection, cracking, and strains on both main reinforcements and concrete of the beams were taken. At the same level of stress, beams with confined concrete strained less than control beams without confinement for both tensile strain at the main steel reinforcement and compressive strain across the compression zone of concrete. Deflections of beams with helical confinement were less than the control beams.All beams failed in shear / flexural mode and gave fair warning against failure, more specifically beams with 1.42ρb, which is not normally associated with shear-type failure of beams which are over reinforced. The early shear failure prevented the beams from achieving its full utilisation of the ultimate strength. It is recommended that for over-reinforced confined concrete beams, the shear strength of beams should be based on using the diagonal compressive strut angle (θ) of more than 22 degrees recommended in Eurocode 2 (EC2), hence giving the beam higher safety factor against shear failure. All samples exhibited flexure and shear cracks in a manner which gave a good warning against failure. The ratio of the failure load to the theoretical ultimate load for shear ranged between 0.98 and 1.25 while the ratio of the failure load to the ultimate flexural load ranged between 1.00 and 1.25. Because of the early shear failure, the effects of spiral spacing could not be well identified.