In Situ Gelling Hydrogel with Anti-Bacterial Activity and Bone Healing Property for Treatment of Osteomyelitis (original) (raw)

Efficacy of antibiotics-loaded interpenetrating network (IPNs) hydrogel based on poly(acrylic acid) and gelatin for treatment of experimental osteomyelitis: in vivo study

Biomaterials, 2005

The safety and efficacy of gentamycin sulphate (GS)-or vancomycin hydrochloride (VCl)-loaded polymer devices based on poly(acrylic acid) and gelatin crosslinked selectively using 0.3 mol % N,N 0 -methylene bisacrylamide and 1 wt% glutaraldehyde were evaluated by varying the drug concentration onto the devices. The placebo and drug-loaded device of AxGx (acrylic acid:gelatin: 1:1 w/w) were employed for the treatment of experimental osteomyelitis in rabbit. Rabbits were categorized into four groups. Twelve rabbits in each group were treated with 1271mg of AxGx-1a (22% w/w GS), 1271mg of AxGx-1b (44% w/w GS), 1671mg of AxGx-1b (44% w/w GS) and 16 7 1 mg of AxGx-1c (44% w/w VCl). The drug concentration was measured following implantation in the adjacent tissue of femoral cavity, and serum. In femoral cavity maximum drug concentration was found on the 7th day with all the four types of devices. No drug was found after 21 days, at the local site with devices AxGx-1a and AxGx-1b (12 7 1 mg), whereas it was detected after 6 weeks with 1671 mg device (44% w/w GS or VCl). Macroscopic evaluation after treatment revealed that swelling, redness, local warmth and drainage decreased depending upon the drug loading of the implants. Sequential radiographs, histology, microbiologic assay and scanning electron micrography demonstrated devices AxGx-1b and AxGx-1c (16 7 1mg of 44% w/w drug loading) to be the most suitable device, which heals the infection after 6 weeks of treatment. No significant difference (p>0.05) in the rate of healing was observed between GS-and VCl-loaded devices. None of the implant showed toxic level of drug in serum at any given time.

Vancomycin-Loaded, Nanohydroxyapatite-Based Scaffold for Osteomyelitis Treatment: In Vivo Rabbit Toxicological Tests and In Vivo Efficacy Tests in a Sheep Model

Bioengineering

The treatment for osteomyelitis consists of surgical debridement, filling of the dead space, soft tissue coverage, and intravenous administration of antimicrobial (AM) agents for long periods. Biomaterials for local delivery of AM agents, while providing controllable antibiotic release rates and simultaneously acting as a bone scaffold, may be a valuable alternative; thus, avoiding systemic AM side effects. V-HEPHAPC is a heparinized nanohydroxyapatite (nHA)/collagen biocomposite loaded with vancomycin that has been previously studied and tested in vitro. It enables a vancomycin-releasing profile with an intense initial burst, followed by a sustained release with concentrations above the Minimum Inhibitory Concentration (MIC) for MRSA. In vitro results have also shown that cellular viability is not compromised, suggesting that V-HEPHAPC granules may be a promising alternative device for the treatment of osteomyelitis. In the present study, V-HEPHAPC (HEPHAPC with vancomycin) granule...

A self-assembled bilayer polypeptide-engineered hydrogel for spatiotemporal modulation of bactericidal and anti-inflammation process in osteomyelitis treatment

Journal of Nanobiotechnology

Background Drug resistance of pathogens and immunosuppression are the main causes of clinical stagnation of osteomyelitis. The ideal treatment strategy for osteomyelitis is to achieve both efficient antibacterial and bone healing through spatiotemporal modulation of immune microenvironment. Methods In this study, a bilayer hydrogel based on genetically engineered polypeptide AC10A and AC10ARGD was prepared by self-assembly. Ag2S QDs@DSPE-mPEG2000-Ce6/Aptamer (AD-Ce6/Apt) was loaded in the top layer AC10A hydrogel (AA) for antibacterial, and bone marrow-derived mesenchymal stem cells (BMSCs) were loaded in the lower layer AC10ARGD hydrogel (MAR) for bone healing. The AD-Ce6/Apt can be released from the AA hydrogel to target S. aureus before bacterial biofilm formation and achieved significant bactericidal effect under irradiation with a 660 nm laser. Moreover, AD-Ce6/Apt can induce M1 type polarization of macrophages to activate the immune system and eliminate residual bacteria. Subs...

In vivo efficiency of antimicrobial inorganic bone grafts in osteomyelitis treatments

Materials Science and Engineering: C, 2018

The purpose of the present work was to evaluate in vivo different antimicrobial therapies to eradicate osteomyelitis created in the femoral head of New Zealand rabbits. Five phosphate-based cements were evaluated: calcium phosphate cements (CPC) and calcium phosphate foams (CPF), both in their pristine form and loaded with doxycycline hyclate, and an intrinsic antimicrobial magnesium phosphate cement (MPC; not loaded with an antibiotic). The cements were implanted in a bone previously infected with Staphylococcus aureus to discern the effects of the type of antibiotic administration (systemic vs. local), porosity (microporosity, i.e. < 5 μm vs. macroporosity, i.e. > 5 μm) and type of antimicrobial mechanism (release of antibiotic vs. intrinsic antimicrobial activity) on the improvement of the health state of the infected animals. A new method was developed, with a more comprehensive composite score that integrates 5 parameters of bone infection, 4 parameters of bone structural integrity and 4 parameters of bone regeneration. This method was used to evaluate the health state of the infected animals, both before and after osteomyelitis treatment. The results show that the composite score allows to discern statistically significant differences between treatments that individual evaluations were not able to identify. Despite none of the therapies completely eradicated the infection, it was observed that 2 macroporous materials (CPF and CPFd, the latter loaded with doxycycline hyclate) and intrinsic antimicrobial MPC allowed a better containment of the osteomyelitis. This study provides novel insights to understand the effect of different antimicrobial therapies in vivo, and a promising comprehensive methodology to evaluate the health state of the animals was developed. We expect that the implementation of such methodology could improve the criteria to select a proper antimicrobial therapy.

Combining local antibiotic delivery with heparinized nanohydroxyapatite/collagen bone substitute: A novel strategy for osteomyelitis treatment

Materials Science and Engineering: C, 2021

Osteomyelitis is a major challenge in bone surgery and conventional treatment is frequently ineffective to control the infection, with an alternative approach being required. In the present work, a heparinized nanohydroxyapatite/collagen biocomposite was produced in granular form, and loaded with vancomycin, to work as a local drug delivery system for osteomyelitis and as a bone substitute. This strategy involves the local delivery of high concentrations of vancomycin, to eradicate the infection. Additionally, these granules work as a scaffold with regenerative properties, to induce bone regeneration after antibiotic release. The heparinized nanohydroxyapatite/collagen granular bone substitute was produced using two different sintering temperatures to study their effect on granules properties and on vancomycin release profile. Morphological, topographic, chemical and mechanical characterization were carried out for granules sintered at both temperatures and some relevant differences were found. The mechanical strength was increased by several orders of magnitude with increasing sintering temperature, being able to maintain their porous macrostructure and withstand important processes for their commercialization such as packaging, shipping and surgical manipulation. The nanohydroxyapatite/collagen granules were able to release high concentrations of vancomycin, always above MIC, for 19 days. The released antibiotic was able to eradicate both planktonic and sessile methicillin-resistant Staphylococcus aureus. The cytotoxicity was assessed according to ISO 10993-5:2009 and the granules sintered at higher temperature showed no cytotoxic effect. Considering these results nanohydroxyapatite/collagen biocomposite loaded with vancomycin is a promising solution for osteomyelitis treatment.

Controlled release of vancomycin from thin sol-gel films on implant surfaces successfully controls osteomyelitis

Journal of Orthopaedic Research, 2009

Peri-prosthetic infection remains a serious complication of joint replacement surgery. Herein, we demonstrate that a vancomycin-containing sol-gel film on Ti alloy rods can successfully treat bacterial infections in an animal model. The vancomycin-containing sol-gel films exhibited predictable release kinetics, while significantly inhibiting S. aureus adhesion. When evaluated in a rat osteomyelitis model, microbiological analysis indicated that the vancomycin-containing sol-gel film caused a profound decrease in S. aureus number. Radiologically, while the control side showed extensive bone degradation, including abscesses and an extensive periosteal reaction, rods coated with the vancomycin-containing sol-gel film resulted in minimal signs of infection. µCT analysis confirmed the radiological results, while demonstrating that the vancomycin-containing sol-gel film significantly protected dense bone from resorption and minimized remodeling. These results clearly demonstrate that this novel thin sol-gel technology can be used for the targeted delivery of antibiotics for the treatment of periprosthetic as well as other bone infections. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 701–709, 2009

Vancomycin-Modified Implant Surface Inhibits Biofilm Formation and Supports Bone-Healing in an Infected Osteotomy Model in Sheep

The Journal of Bone and Joint Surgery (American), 2012

Implant-associated infections contribute to patient morbidity and health care costs. We hypothesized that surface modification of titanium fracture hardware with vancomycin would support bone-healing and prevent bacterial colonization of the implant in a large-animal model. A unilateral transverse mid-diaphyseal tibial osteotomy was performed and repaired with a titanium locking compression plate in nine sheep. Four control animals were treated with an unmodified plate and five experimental animals were treated with a vancomycin-modified plate. The osteotomy was inoculated with 2.5 × 106 colony-forming units of Staphylococcus aureus. The animals were killed at three months postoperatively, and implants were retrieved aseptically. Microbiologic and histologic analyses, scanning electron and confocal microscopy, and microcomputed tomography were performed. All animals completed the study. Compared with the treatment cohort, control animals exhibited protracted lameness in the operatively treated leg. Gross findings during necropsy were consistent with an infected osteotomy accompanied by a florid and lytic callus. Microcomputed tomography and histologic analysis of the tibiae further supported the presence of septic osteomyelitis in the control cohort. Thick biofilms were also evident, and bacterial cultures were positive for Staphylococcus aureus in three of four control animals. In contrast, animals treated with vancomycin-treated plates exhibited a healed osteotomy site with homogenous remodeling, there was no evidence of biofilm formation on the retrieved plate, and bacterial cultures from only one of five animals were positive for Staphylococcus aureus. Vancomycin-derivatized plate surfaces inhibited implant colonization with Staphylococcus aureus and supported bone-healing in an infected large-animal model.

Local application of a gentamicin-loaded thermo-responsive hydrogel allows for fracture healing upon clearance of a high Staphylococcus aureus load in a rabbit model

PubMed, 2018

Antibiotic-loaded biomaterials (ALBs) have emerged as a potential useful adjunctive antimicrobial measure for the prevention of infection in open fracture care. A biodegradable thermo-responsive poly(N-isopropylacrylamide) grafted hyaluronic acid (HApN) hydrogel loaded with gentamicin has recently been shown to prevent implant-related infection in a rabbit osteosynthesis model. The primary aim of this study was to determine the influence of this HApN hydrogel on bone healing at an early stage (4 weeks). A rabbit humeral osteotomy model with plating osteosynthesis was used to compare fracture healing in rabbits receiving the hydrogel as compared with control animals. The secondary aim was to observe fracture healing in groups treated with and without antibiotic-loaded hydrogel in the presence of bacterial contamination. In all groups, outcome measures were mechanical stability and histological score, with additional quantitative bacteriology in the inoculated groups. Application of the HApN hydrogel in non-inoculated rabbits did not significantly influence humeral stiffness or histological scores for fracture healing in comparison to controls. In the inoculated groups, animals receiving the bacterial inoculum without hydrogel were culture-positive at euthanasia and found to display lower humeral stiffness values and higher histopathological scores for bacterial presence in comparison with equivalents receiving the gentamicin-loaded HApN hydrogel, which were also infection-free. In summary, our data showed that HApN was an effective antibiotic carrier that did not affect fracture healing. This data supported its suitability for application in fracture care. Addition of osteopromotive compounds could provide further support for accelerating fracture healing in addition to successful infection prophylaxis.

Antibacterial activity of bone allografts: Comparison of a new vancomycin-tethered allograft with allograft loaded with adsorbed vancomycin

Bone, 2011

Bacterial contamination of bone allograft is a significant complication of orthopaedic surgery. To address this issue, we have engineered a method for covalently modifying bone allograft tissue with the antibiotic vancomycin. The goal of this investigation was to compare the biocidal properties of this new allograft material with those of vancomycin physisorbed onto graft material. The duration of antibiotic release from the vancomycin-modified allograft matrix was determined and no elution was observed. In contrast, the adsorbed antibiotic showed a peak elution at 24 h that then decreased over several days. We next used an S. aureus disk diffusion assay to measure the activity of the eluted vancomycin. Again we found that no active antibiotic was eluted from the covalently-modified allograft. Similarly, when the vancomycin-modified allograft morsel was used in the assay, no measurable elution was observed; amounts of antibiotic released from the adsorbed samples inhibited S. aureus growth for 4-7 days. Probably the most telling property of the allograft was that after two weeks, the tethered-allograft was able to resist bacterial colonization. Unlike the elution system in which vancomycin was depleted over the course of Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.