Biomechanical analysis of different implant-abutments interfaces in different bone types: An in silico analysis (original) (raw)
Influence of prosthesis type and material on the stress distribution in bone around implants: A 3-dimensional finite element analysis
Ahmet Kurt
Journal of Dental Sciences, 2011
View PDFchevron_right
Comparison of Stress In Peri-Implant Bone of Anterior Maxilla on Loading of Straight and Angulated Platform Switched Implant Abutments - A 3D Finite Element Analysis
Shailesh Kumar
Archives of Clinical and Medical Case Reports, 2020
View PDFchevron_right
Finite Element Analysis Of Stress Behaviour In A Novel Implant Platform Under Axial and Non -Axial Loading Conditions -An In Vitro Study
International Journal of Dentistry and Oral Science (IJDOS)
SciDoc Publishers, 2021
View PDFchevron_right
The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study
Luigi Canullo
Medicina Oral Patología Oral y Cirugia Bucal, 2011
View PDFchevron_right
Stress-Strain Distribution at Bone-Implant Interface Using 3D Finite Element Analysis
Durmuş Ali Bircan
2016
View PDFchevron_right
Biomechanical Evaluation of Bone Quality Effect on Stresses at Bone-Implant Interface: A Finite Element Study
Rajshree Hillstrom
Applied and Computational Mechanics, 2020
View PDFchevron_right
Stress patterns on implants in prostheses supported by four or six implants: a three-dimensional finite element analysis
Janes Landre
The International Journal of Oral Maxillofacial Implants, 2010
View PDFchevron_right
Finite Element Analysis of Stress in Bone and Abutment-Implant Interface under Static and Cyclic Loadings
SAIED NOKAR
Frontiers in Dentistry, 2020
View PDFchevron_right
Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis
Özgür Öztürk
Bio-medical materials and engineering, 2018
View PDFchevron_right
Assessment of the stresses produced on the bone implant/tissue interface to the different insertion angulations of the implant - a three-dimensional analysis by the finite elements method
Juliana Ramacciato
Journal of Clinical and Experimental Dentistry
View PDFchevron_right
Analysis of the distribution of stress and deformation in single implant-supported prosthetic units in implants of different diameters
Bruno Sotto-Maior
Revista de Odontologia da UNESP, 2016
View PDFchevron_right
Effect of Implant Platform Switching on Strain Developed Around Implants with Straight and Angled Abutments
Hanaa Sallam
Egyptian Dental Journal
View PDFchevron_right
Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads
Hyeonjong Lee
The Journal of Advanced Prosthodontics
View PDFchevron_right
Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants
Priscilla Lazari
2016
View PDFchevron_right
Evaluation of Stress Distribution Among Two Different Preangled Abutments of Implants in Two Different Densities of Bone at Different Levels Along the Implant–In Vitro Study
Ramesh Tirnati
The Journal of Contemporary Dental Practice, 2018
View PDFchevron_right
Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysis
Wirley Assunção
Dental Materials, 2012
View PDFchevron_right
Biomechanical Behavior of Implants with a Sloped Marginal Configuration
Barış Güncü
The International Journal of Prosthodontics
View PDFchevron_right
Influence of Cusp Inclination on Stress Distribution in Implant-Supported Prostheses. A Three-Dimensional Finite Element Analysis
Rosse Mary Falcón
Journal of Prosthodontics, 2010
View PDFchevron_right
3D finite element non linear analysis on the stress state at bone-implant interface in dental osteointegrated implants
Alberto Barlattani
ORAL & implantology, 2010
View PDFchevron_right
A 3-D Finite Element Analysis of Stress Distribution on Implant-supported Fixed Prosthesis with Four Different Commercially Available Implant Systems
Ritwik Tyagi
2020
View PDFchevron_right
Investigation of the dental implant geometry effect on stress distribution at dental implant–bone interface
Sadegh Hemmati Salekdeh
Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2015
View PDFchevron_right
The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis
David C Watts
Dental Materials, 2021
View PDFchevron_right
Analyzing the Effects of the Platform-Switching Procedure on Stresses in the Bone and Implant-Abutment Complex by 3-Dimensional Fem Analysis
HAYDAR ÇİMEN
Journal of Oral Implantology, 2012
View PDFchevron_right
Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
Mauro Antonio de Arruda Nóbilo
Journal of Oral Implantology, 2015
View PDFchevron_right
Evaluation of Stress Distribution in Implant Body and Surrounding Bone with and without Splinting—A Three-Dimensional Finite Element Analysis: An In Vitro Study
Manjit Kumar
Dental Journal of Advance Studies
View PDFchevron_right
Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants - CT-Based Nonlinear, Three-Dimensional Finite Element Analysis
Jos Sloten
Clinical Implant Dentistry and Related Research, 2009
View PDFchevron_right
Influence of Implant Surface Topography and Loading Condition on Stress Distribution in Bone Around Implants: A Comparative 3D FEA
Jatin Agarwal
The Journal of Indian …, 2011
View PDFchevron_right
Stress Analysis in Platform-Switching Implants: A 3-Dimensional Finite Element Study
Fellippo Ramos Verri
Journal of Oral Implantology, 2012
View PDFchevron_right