Preliminary Determination of the Optimal Parameters When Using an Ultrasonic Probe to Measure Cavern Geometry Where a Metal Borehole Pipe Is Present (original) (raw)

In order to determine the optimal parameters when using an ultrasonic probe to measure cavern geometry when a metal borehole pipe is present, an investigation was firstly carried out on influence of a vertical metal plates with a thickness from 1 mm to 15 mm immersed in water on transmitted and reflected ultrasonic waves. The results obtained will be used as an indicator for the measurement of underground geometry in which the ultrasonic probe is placed inside a metal pipe lining a borehole. These studies were performed both by experiment and computer simulation. The results show that the wavelength of the incident ultrasonic signals should be equal to half the thickness of the metal plate or an integer times smaller than this thickness. When the thickness of the barrier is unknown, an ultrasonic signal with linear frequency modulation (LFM) should be used. Due to the reverberation of the ultrasonic waves inside the pipe for caverns filled with water, the distance from the transduce...

Loading...

Loading Preview

Sorry, preview is currently unavailable. You can download the paper by clicking the button above.