The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved? - PubMed (original) (raw)
Review
The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved?
Jeffrey A Kraut et al. Clin J Am Soc Nephrol. 2013 Nov.
Abstract
The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8-10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3(-)] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested.
Similar articles
- Low anion gap.
Jurado RL, del Rio C, Nassar G, Navarette J, Pimentel JL Jr. Jurado RL, et al. South Med J. 1998 Jul;91(7):624-9. doi: 10.1097/00007611-199807000-00004. South Med J. 1998. PMID: 9671832 Review. - Serum anion gap: its uses and limitations in clinical medicine.
Kraut JA, Madias NE. Kraut JA, et al. Clin J Am Soc Nephrol. 2007 Jan;2(1):162-74. doi: 10.2215/CJN.03020906. Epub 2006 Dec 6. Clin J Am Soc Nephrol. 2007. PMID: 17699401 Review. - Mixed acid-base disorders.
Adams LG, Polzin DJ. Adams LG, et al. Vet Clin North Am Small Anim Pract. 1989 Mar;19(2):307-26. doi: 10.1016/s0195-5616(89)50032-9. Vet Clin North Am Small Anim Pract. 1989. PMID: 2494782 Review. - Acid-base disturbances in nephrotic syndrome: analysis using the CO2/HCO3 method (traditional Boston model) and the physicochemical method (Stewart model).
Kasagi T, Imai H, Miura N, Suzuki K, Yoshino M, Nobata H, Nagai T, Banno S. Kasagi T, et al. Clin Exp Nephrol. 2017 Oct;21(5):866-876. doi: 10.1007/s10157-017-1387-8. Epub 2017 Mar 13. Clin Exp Nephrol. 2017. PMID: 28289910 Free PMC article. - [The magnitude of the 'anion gap'].
de Keijzer MH, Koene RA, Baadenhuijsen H, Willems JL. de Keijzer MH, et al. Ned Tijdschr Geneeskd. 1999 Mar 27;143(13):666-7. Ned Tijdschr Geneeskd. 1999. PMID: 10321298 Clinical Trial. Dutch.
Cited by
- Treatment of acute non-anion gap metabolic acidosis.
Kraut JA, Kurtz I. Kraut JA, et al. Clin Kidney J. 2015 Feb;8(1):93-9. doi: 10.1093/ckj/sfu126. Epub 2014 Dec 1. Clin Kidney J. 2015. PMID: 25852932 Free PMC article. - A comparison of random survival forest and Cox regression for prediction of mortality in patients with hemorrhagic stroke.
Wang Y, Deng Y, Tan Y, Zhou M, Jiang Y, Liu B. Wang Y, et al. BMC Med Inform Decis Mak. 2023 Oct 13;23(1):215. doi: 10.1186/s12911-023-02293-2. BMC Med Inform Decis Mak. 2023. PMID: 37833724 Free PMC article. - Association between anion gap and the 30-day mortality of patients with ventilator-associated pneumonia: a study of the MIMIC-III database.
Yu H, Chen S. Yu H, et al. J Thorac Dis. 2024 May 31;16(5):2994-3006. doi: 10.21037/jtd-23-1735. Epub 2024 May 20. J Thorac Dis. 2024. PMID: 38883665 Free PMC article. - Disorders of Acid-Base Balance: New Perspectives.
Seifter JL, Chang HY. Seifter JL, et al. Kidney Dis (Basel). 2017 Jan;2(4):170-186. doi: 10.1159/000453028. Epub 2016 Dec 10. Kidney Dis (Basel). 2017. PMID: 28232934 Free PMC article. Review. - Anion Gap Was Associated with Inhospital Mortality and Adverse Clinical Outcomes of Coronary Care Unit Patients.
Sun T, Cai C, Shen H, Yang J, Guo Q, Zhang J, Zhang B, Ding Y, Zhou Y. Sun T, et al. Biomed Res Int. 2020 Aug 27;2020:4598462. doi: 10.1155/2020/4598462. eCollection 2020. Biomed Res Int. 2020. PMID: 32908890 Free PMC article.
References
- Lolekha PH, Lolekha S: Value of the anion gap in clinical diagnosis and laboratory evaluation. Clin Chem 29: 279–283, 1983 - PubMed
- Emmett M, Narins RG: Clinical use of the anion gap. Medicine (Baltimore) 56: 38–54, 1977 - PubMed
- Kraut JA, Madias NE: Serum anion gap: Its uses and limitations in clinical medicine. Clin J Am Soc Nephrol 2: 162–174, 2007 - PubMed
- Emmett M: Anion gap interpretation: The old and the new. Nat Clin Pract Nephrol 2: 4–5, 2006 - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous