G. Mrozynski | University of Paderborn (original) (raw)
Papers by G. Mrozynski
SIGLETechnische Informationsbibliothek Hannover: AC 5791. / FIZ - Fachinformationszzentrum Karlsr... more SIGLETechnische Informationsbibliothek Hannover: AC 5791. / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman
1986 IEEE International Symposium on Electromagnetic Compatibility, 1986
1985 IEEE International Symposium on Electromagnetic Compatibility, 1985
In the literature the magnetic shielding effect of a screen has been u s u a l ly treated in a ... more In the literature the magnetic shielding effect of a screen has been u s u a l ly treated in a simplified manner. In this paper, however, we show that the problem is more complicated. The object of investiga tion consists of a perturbing and a pertur bed line, both separated by a conducting screen, where the perturbing line carries an impressed current while the perturbed line is used to connect a load with a source of impressed voltage. The eddy currents in duced by the two lines in the screen as well as in the perturbed line depend on the load and on the geometry of the shielding system. For the description of the transient shield ing problem we use an integral equation, where the domain of integration extends over the cross-sections of the screen and of the perturbed line. The investigation of the system's shielding properties requires a solution to the eigenvalue problem of the integral equation which leads to a non-line ar matrix eigenvalue problem. In the case of alternating currents we replace the shielding system by an equivalent network model having frequency-dependent components. The paper contains the derivation of the general theory. Its results can be directly applied to the. treatment of special screens.
New technologies will give the chance to integrate a variety of servicesihto one system. This wil... more New technologies will give the chance to integrate a variety of servicesihto one system. This will lead to traffic flows with different bandwidth, different busy hours, and different local traffic distributions. As it will become more difficult to forecast traffic parameters reliably the flexibility of networks to traffic variations will become more and more important. The paper introduces a performance index D describing the degradation of grade of service in case of overload caused by a changing traffic matrix. Some simple examples show in which way D can be applied to describe the performance of a network.
IEEE Transactions on Electromagnetic Compatibility, 1999
International Journal of Applied Electromagnetics and Mechanics
Electrical Engineering, 1985
Electrical Engineering, 1986
Übersicht Der Beitrag beschreibt ein Verfahren zur Berechnung der Stromdichteverteilung in Kontak... more Übersicht Der Beitrag beschreibt ein Verfahren zur Berechnung der Stromdichteverteilung in Kontakten, wenn der vorgegebene Gesamtstrom einen beliebigen zeitlichen Verlauf hat. Die Erfüllung der Randbedingungen an den Bereichsgrenzen von Leitern unterschiedlicher Geometrie führt auf ein lineares Gleichungssystem mit im Grenzfall unendlich vielen Konstanten. Um den damit verbundenen Rechenaufwand zu vermeiden, wurde ein Näherungsverfahren entwickelt. Dabei wird der Feldverlauf durch Integration
Electrical Engineering, 1980
1999 IEEE International Symposium on Electromagnetic Compatability. Symposium Record (Cat. No.99CH36261), 2000
1999 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.99EX147), 2000
If thin walls have to be discretized in the numerical treatment of shielding problems, the comput... more If thin walls have to be discretized in the numerical treatment of shielding problems, the computation tends to be become cumbersome since the fine discretization needed in the thin shielding walls will enforce an overall mesh with a great number of nodes. To overcome this difficulty, a jump condition, approximately valid at thin shielding walls, is introduced. The error induced
21st European Microwave Conference, 1991, 1991
An efficient technique for calculating the electromagnetic fields of metal-insulator-semiconducto... more An efficient technique for calculating the electromagnetic fields of metal-insulator-semiconductor (MIS) transmission lines is presented. MIS transmission lines with typical dimensions of integrated circuits are analysed. In dependence to the conductivity of the semiconductor layer, the propagation constant is evaluated and three distinct modes of propagation are discussed. In order to illustrate the mechanism of propagation the complete electromagnetic field
Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402), 2000
IEEE Transactions on Magnetics, 1998
Electrical Engineering (Archiv fur Elektrotechnik), 2001
Electrical Engineering, 1998
Archiv f�r Elektrotechnik, 1977
Übersicht In früheren Abhandlungen einiger Autoren wurde das räumliche Feld eines Turbogenerators... more Übersicht In früheren Abhandlungen einiger Autoren wurde das räumliche Feld eines Turbogenerators mit supraleitender Erregerwicklung mit Hilfe des Vektorpotentials berechnet, das in den verwendeten Zylinderkoordinaten notwendigerweise aus allen drei Komponenten besteht. In der vorliegenden Arbeit wird zur Feldbeschreibung das magnetische Skalarpotential verwendet, das das vorliegende Feld als eine einzige Ortsfunktion wesentlich einfacher zu beschreiben vermag. Allgemeine Feldbeziehungen werden zunächst für den Fall einer Flachspule beliebiger Fläche abgeleitet und auf eine räumliche Spule erweitert. Die Konstanten, die man in den Ausdrücken für das magnetische Skalarpotential benötigt, werden aus der Stromfunktion der erregenden Spule berechnet. Für den Fall einer Erregerspule, die aus Rechteckwindungen besteht, werden allgemeine Beziehungen für die Konstanten angegeben. Abschließend wird durch Einführung eines skalaren Polarisationspotentials der Einfluß zylindrischer magnetischer Schirme erfaßt.
Archiv f�r Elektrotechnik, 1987
Übersicht Einer leitenden, massiven Kugel wird aus einer Leiterschleife beliebiger Kontur im umge... more Übersicht Einer leitenden, massiven Kugel wird aus einer Leiterschleife beliebiger Kontur im umgebenden nichteleitenden Raum an zwei beliebigen Punkten auf der Kugeloberfläche ein Strom cosinusförmiger Zeitabhängigkeit zugeführt bzw. entnommen. Die räumliche Stromdichteverteilung wird durch Superposition zweier Tellösungen dargestellt. Eine der Lösungen stellt eine Stromdichteverteilung mit verschwindender radialer Komponente in der Kugel dar, die von einer Leiterschleife erregt wird, deren Kontur
SIGLETechnische Informationsbibliothek Hannover: AC 5791. / FIZ - Fachinformationszzentrum Karlsr... more SIGLETechnische Informationsbibliothek Hannover: AC 5791. / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman
1986 IEEE International Symposium on Electromagnetic Compatibility, 1986
1985 IEEE International Symposium on Electromagnetic Compatibility, 1985
In the literature the magnetic shielding effect of a screen has been u s u a l ly treated in a ... more In the literature the magnetic shielding effect of a screen has been u s u a l ly treated in a simplified manner. In this paper, however, we show that the problem is more complicated. The object of investiga tion consists of a perturbing and a pertur bed line, both separated by a conducting screen, where the perturbing line carries an impressed current while the perturbed line is used to connect a load with a source of impressed voltage. The eddy currents in duced by the two lines in the screen as well as in the perturbed line depend on the load and on the geometry of the shielding system. For the description of the transient shield ing problem we use an integral equation, where the domain of integration extends over the cross-sections of the screen and of the perturbed line. The investigation of the system's shielding properties requires a solution to the eigenvalue problem of the integral equation which leads to a non-line ar matrix eigenvalue problem. In the case of alternating currents we replace the shielding system by an equivalent network model having frequency-dependent components. The paper contains the derivation of the general theory. Its results can be directly applied to the. treatment of special screens.
New technologies will give the chance to integrate a variety of servicesihto one system. This wil... more New technologies will give the chance to integrate a variety of servicesihto one system. This will lead to traffic flows with different bandwidth, different busy hours, and different local traffic distributions. As it will become more difficult to forecast traffic parameters reliably the flexibility of networks to traffic variations will become more and more important. The paper introduces a performance index D describing the degradation of grade of service in case of overload caused by a changing traffic matrix. Some simple examples show in which way D can be applied to describe the performance of a network.
IEEE Transactions on Electromagnetic Compatibility, 1999
International Journal of Applied Electromagnetics and Mechanics
Electrical Engineering, 1985
Electrical Engineering, 1986
Übersicht Der Beitrag beschreibt ein Verfahren zur Berechnung der Stromdichteverteilung in Kontak... more Übersicht Der Beitrag beschreibt ein Verfahren zur Berechnung der Stromdichteverteilung in Kontakten, wenn der vorgegebene Gesamtstrom einen beliebigen zeitlichen Verlauf hat. Die Erfüllung der Randbedingungen an den Bereichsgrenzen von Leitern unterschiedlicher Geometrie führt auf ein lineares Gleichungssystem mit im Grenzfall unendlich vielen Konstanten. Um den damit verbundenen Rechenaufwand zu vermeiden, wurde ein Näherungsverfahren entwickelt. Dabei wird der Feldverlauf durch Integration
Electrical Engineering, 1980
1999 IEEE International Symposium on Electromagnetic Compatability. Symposium Record (Cat. No.99CH36261), 2000
1999 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.99EX147), 2000
If thin walls have to be discretized in the numerical treatment of shielding problems, the comput... more If thin walls have to be discretized in the numerical treatment of shielding problems, the computation tends to be become cumbersome since the fine discretization needed in the thin shielding walls will enforce an overall mesh with a great number of nodes. To overcome this difficulty, a jump condition, approximately valid at thin shielding walls, is introduced. The error induced
21st European Microwave Conference, 1991, 1991
An efficient technique for calculating the electromagnetic fields of metal-insulator-semiconducto... more An efficient technique for calculating the electromagnetic fields of metal-insulator-semiconductor (MIS) transmission lines is presented. MIS transmission lines with typical dimensions of integrated circuits are analysed. In dependence to the conductivity of the semiconductor layer, the propagation constant is evaluated and three distinct modes of propagation are discussed. In order to illustrate the mechanism of propagation the complete electromagnetic field
Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402), 2000
IEEE Transactions on Magnetics, 1998
Electrical Engineering (Archiv fur Elektrotechnik), 2001
Electrical Engineering, 1998
Archiv f�r Elektrotechnik, 1977
Übersicht In früheren Abhandlungen einiger Autoren wurde das räumliche Feld eines Turbogenerators... more Übersicht In früheren Abhandlungen einiger Autoren wurde das räumliche Feld eines Turbogenerators mit supraleitender Erregerwicklung mit Hilfe des Vektorpotentials berechnet, das in den verwendeten Zylinderkoordinaten notwendigerweise aus allen drei Komponenten besteht. In der vorliegenden Arbeit wird zur Feldbeschreibung das magnetische Skalarpotential verwendet, das das vorliegende Feld als eine einzige Ortsfunktion wesentlich einfacher zu beschreiben vermag. Allgemeine Feldbeziehungen werden zunächst für den Fall einer Flachspule beliebiger Fläche abgeleitet und auf eine räumliche Spule erweitert. Die Konstanten, die man in den Ausdrücken für das magnetische Skalarpotential benötigt, werden aus der Stromfunktion der erregenden Spule berechnet. Für den Fall einer Erregerspule, die aus Rechteckwindungen besteht, werden allgemeine Beziehungen für die Konstanten angegeben. Abschließend wird durch Einführung eines skalaren Polarisationspotentials der Einfluß zylindrischer magnetischer Schirme erfaßt.
Archiv f�r Elektrotechnik, 1987
Übersicht Einer leitenden, massiven Kugel wird aus einer Leiterschleife beliebiger Kontur im umge... more Übersicht Einer leitenden, massiven Kugel wird aus einer Leiterschleife beliebiger Kontur im umgebenden nichteleitenden Raum an zwei beliebigen Punkten auf der Kugeloberfläche ein Strom cosinusförmiger Zeitabhängigkeit zugeführt bzw. entnommen. Die räumliche Stromdichteverteilung wird durch Superposition zweier Tellösungen dargestellt. Eine der Lösungen stellt eine Stromdichteverteilung mit verschwindender radialer Komponente in der Kugel dar, die von einer Leiterschleife erregt wird, deren Kontur