Grating-coupled interferometry (original) (raw)
Grating-coupled interferometry (GCI) is a biophysical characterization method mainly used in biochemistry and drug discovery for label-free analysis of molecular interactions. Similar to other optical methods such as surface plasmon resonance (SPR) or bio-layer interferometry (BLI), it is based on measuring refractive index changes within an evanescent field near a sensor surface. After immobilizing a target to the sensor surface, analyte molecules in solution which bind to that target cause a small increase in local refractive index. By monitoring these refractive changes over time characteristics such as kinetic rates and affinity constants of the analyte-target binding, or analyte concentrations, can be determined.
Property | Value |
---|---|
dbo:abstract | Die Gitter-gekoppelte Interferometrie (englisch grating-coupled interferometry) ist eine biophysikalische Charakterisierungsmethode, die hauptsächlich in der Biochemie und zur markierungsfreien Analyse molekularer Wechselwirkungen verwendet wird. Ähnlich wie andere optische Verfahren wie die Oberflächenplasmonenresonanzspektroskopie oder die Bio-Layer-Interferometrie basiert sie auf der Messung von Brechungsindexänderungen innerhalb eines evaneszenten Feldes in der Nähe einer Sensoroberfläche. Nach der Immobilisierung eines Targets auf der Sensoroberfläche verursachen Analytmoleküle in Lösung, die an dieses Target binden, eine geringe Erhöhung des lokalen Brechungsindex. Durch das Überwachen dieser refraktiven Veränderungen über die Zeit können Eigenschaften wie kinetische Geschwindigkeiten und Affinitätskonstanten der Analyt-Target-Bindung oder Analytkonzentrationen bestimmt werden. (de) Grating-coupled interferometry (GCI) is a biophysical characterization method mainly used in biochemistry and drug discovery for label-free analysis of molecular interactions. Similar to other optical methods such as surface plasmon resonance (SPR) or bio-layer interferometry (BLI), it is based on measuring refractive index changes within an evanescent field near a sensor surface. After immobilizing a target to the sensor surface, analyte molecules in solution which bind to that target cause a small increase in local refractive index. By monitoring these refractive changes over time characteristics such as kinetic rates and affinity constants of the analyte-target binding, or analyte concentrations, can be determined. (en) |
dbo:thumbnail | wiki-commons:Special:FilePath/Grating-coupled_interferometry.png?width=300 |
dbo:wikiPageID | 68446173 (xsd:integer) |
dbo:wikiPageLength | 3803 (xsd:nonNegativeInteger) |
dbo:wikiPageRevisionID | 1098010481 (xsd:integer) |
dbo:wikiPageWikiLink | dbr:Biochemistry dbr:Interactome dbr:Interferometry dbr:Ligand_(biochemistry) dbr:Ligand_binding_assay dbc:Biophysics dbr:Label-free_quantification dbc:Plasmonics dbc:Forensic_techniques dbr:Drug_discovery dbc:Biochemistry_methods dbc:Electromagnetism dbc:Nanotechnology dbc:Spectroscopy dbc:Optical_phenomena dbc:Protein–protein_interaction_assays dbr:Bio-layer_interferometry dbr:Biophysics dbr:Refractive_index dbr:Surface_plasmon_resonance dbr:Immunoassay dbr:Receptor–ligand_kinetics dbr:Evanescent_field dbr:File:Grating-coupled_interferometry.png |
dbp:wikiPageUsesTemplate | dbt:Citation_needed dbt:Reflist dbt:Biophysics-stub |
dcterms:subject | dbc:Biophysics dbc:Plasmonics dbc:Forensic_techniques dbc:Biochemistry_methods dbc:Electromagnetism dbc:Nanotechnology dbc:Spectroscopy dbc:Optical_phenomena dbc:Protein–protein_interaction_assays |
rdfs:comment | Grating-coupled interferometry (GCI) is a biophysical characterization method mainly used in biochemistry and drug discovery for label-free analysis of molecular interactions. Similar to other optical methods such as surface plasmon resonance (SPR) or bio-layer interferometry (BLI), it is based on measuring refractive index changes within an evanescent field near a sensor surface. After immobilizing a target to the sensor surface, analyte molecules in solution which bind to that target cause a small increase in local refractive index. By monitoring these refractive changes over time characteristics such as kinetic rates and affinity constants of the analyte-target binding, or analyte concentrations, can be determined. (en) Die Gitter-gekoppelte Interferometrie (englisch grating-coupled interferometry) ist eine biophysikalische Charakterisierungsmethode, die hauptsächlich in der Biochemie und zur markierungsfreien Analyse molekularer Wechselwirkungen verwendet wird. Ähnlich wie andere optische Verfahren wie die Oberflächenplasmonenresonanzspektroskopie oder die Bio-Layer-Interferometrie basiert sie auf der Messung von Brechungsindexänderungen innerhalb eines evaneszenten Feldes in der Nähe einer Sensoroberfläche. Nach der Immobilisierung eines Targets auf der Sensoroberfläche verursachen Analytmoleküle in Lösung, die an dieses Target binden, eine geringe Erhöhung des lokalen Brechungsindex. Durch das Überwachen dieser refraktiven Veränderungen über die Zeit können Eigenschaften wie kinetische Geschwindigkeit (de) |
rdfs:label | Gitter-gekoppelte Interferometrie (de) Grating-coupled interferometry (en) |
owl:sameAs | wikidata:Grating-coupled interferometry dbpedia-de:Grating-coupled interferometry https://global.dbpedia.org/id/FsM94 |
prov:wasDerivedFrom | wikipedia-en:Grating-coupled_interferometry?oldid=1098010481&ns=0 |
foaf:depiction | wiki-commons:Special:FilePath/Grating-coupled_interferometry.png |
foaf:isPrimaryTopicOf | wikipedia-en:Grating-coupled_interferometry |
is dbo:wikiPageRedirects of | dbr:Grating-Coupled_Interferometry |
is dbo:wikiPageWikiLink of | dbr:Grating-Coupled_Interferometry |
is foaf:primaryTopic of | wikipedia-en:Grating-coupled_interferometry |