dbo:abstract |
Les synchronverters ou générateurs synchrones virtuels sont des onduleurs qui imitent les générateurs synchrones pour fournir une «inertie synthétique» aux services auxiliaires dans les systèmes électriques. (fr) Synchronverters or virtual synchronous generators are inverters which mimic synchronous generators (SG) to provide "synthetic inertia" for ancillary services in electric power systems. Inertia is a property of standard synchronous generators associated with the rotating physical mass of the system spinning at a frequency proportional to the electricity being generated. Inertia has implications towards grid stability as work is required to alter the kinetic energy of the spinning physical mass and therefore opposes changes in grid frequency. Inverter-based generation inherently lacks this property as the waveform is being created artificially via power electronics. (en) 仮想同期発電機(enːSynchronverters or virtual synchronous generators)は、同期発電機(SG) の動作をシミュレーションすることで、電力系統に「慣性」を持たせるインバーターである。 同期発電機の回転エネルギー・慣性によって電力系統は負荷の急変が生じても急に止まったり加速したりはせず発電機はある程度一定の周波数で電力を供給し、安定した交流電流を供給する。 一方インバーター(半導体)による変電を行う太陽光発電などはこうした慣性力を持たない。そのため同期発電機をコンピューター上でシミュレーション、これを模倣した動作をインバーターに行わせ、慣性力を持たせる。 (ja) |
dbo:thumbnail |
wiki-commons:Special:FilePath/Synchronverter.png?width=300 |
dbo:wikiPageID |
52847079 (xsd:integer) |
dbo:wikiPageLength |
12988 (xsd:nonNegativeInteger) |
dbo:wikiPageRevisionID |
1109899025 (xsd:integer) |
dbo:wikiPageWikiLink |
dbr:Hydro-Québec dbr:Inertia dbr:Inertial_response dbr:Power_inverter dbr:Ancillary_services_(electric_power) dbr:Low_voltage_ride_through dbr:Load_following_power_plant dbr:Hornsdale_Power_Reserve dbr:Photovoltaics dbc:Power_electronics dbr:Reliability_engineering dbr:Wind_turbine_design dbc:Electric_power_systems_components dbr:Synchronize dbr:Digital_signal_processor dbc:Inverters dbr:Moment_of_inertia dbr:Microgrid dbr:Intelligent_hybrid_inverter dbr:Utility_frequency dbr:Synchronous_motor dbr:Inverter dbr:Synchronous_generator dbr:Power_system dbr:Dq-axes dbr:File:Synchronverter.png dbr:File:Synchronverter_PV.png dbr:File:Synchronverter_compact_control.png dbr:File:Synchronverter_control.png dbr:File:Synchronverter_grid.png dbr:File:Synchronverter_power_part.png |
dbp:wikiPageUsesTemplate |
dbt:Nbsp dbt:Reflist dbt:Short_description |
dct:subject |
dbc:Power_electronics dbc:Electric_power_systems_components dbc:Inverters |
rdfs:comment |
Les synchronverters ou générateurs synchrones virtuels sont des onduleurs qui imitent les générateurs synchrones pour fournir une «inertie synthétique» aux services auxiliaires dans les systèmes électriques. (fr) Synchronverters or virtual synchronous generators are inverters which mimic synchronous generators (SG) to provide "synthetic inertia" for ancillary services in electric power systems. Inertia is a property of standard synchronous generators associated with the rotating physical mass of the system spinning at a frequency proportional to the electricity being generated. Inertia has implications towards grid stability as work is required to alter the kinetic energy of the spinning physical mass and therefore opposes changes in grid frequency. Inverter-based generation inherently lacks this property as the waveform is being created artificially via power electronics. (en) 仮想同期発電機(enːSynchronverters or virtual synchronous generators)は、同期発電機(SG) の動作をシミュレーションすることで、電力系統に「慣性」を持たせるインバーターである。 同期発電機の回転エネルギー・慣性によって電力系統は負荷の急変が生じても急に止まったり加速したりはせず発電機はある程度一定の周波数で電力を供給し、安定した交流電流を供給する。 一方インバーター(半導体)による変電を行う太陽光発電などはこうした慣性力を持たない。そのため同期発電機をコンピューター上でシミュレーション、これを模倣した動作をインバーターに行わせ、慣性力を持たせる。 (ja) |
rdfs:label |
Synchronverter (fr) 仮想同期発電機 (ja) Synchronverter (en) |
owl:sameAs |
yago-res:Synchronverter wikidata:Synchronverter dbpedia-fr:Synchronverter dbpedia-ja:Synchronverter https://global.dbpedia.org/id/2eUPa |
prov:wasDerivedFrom |
wikipedia-en:Synchronverter?oldid=1109899025&ns=0 |
foaf:depiction |
wiki-commons:Special:FilePath/Synchronverter.png wiki-commons:Special:FilePath/Synchronverter_PV.png wiki-commons:Special:FilePath/Synchronverter_compact_control.png wiki-commons:Special:FilePath/Synchronverter_control.png wiki-commons:Special:FilePath/Synchronverter_grid.png wiki-commons:Special:FilePath/Synchronverter_power_part.png |
foaf:isPrimaryTopicOf |
wikipedia-en:Synchronverter |
is dbo:wikiPageRedirects of |
dbr:Synchronous_converter dbr:Synthetic_inertia dbr:Virtual_synchronous_generator |
is dbo:wikiPageWikiLink of |
dbr:Energy_in_South_Australia dbr:Neutral_Point_Clamped dbr:Hornsdale_Wind_Farm dbr:Power_inverter dbr:Ancillary_services_(electric_power) dbr:Mount_Tom_Price_mine dbr:Battery_storage_power_station dbr:Hornsdale_Power_Reserve dbr:Wind_power_in_California dbr:Hawaii_Public_Utilities_Commission dbr:Black_start dbr:Solar_inverter dbr:Microgrid dbr:Rooftop_solar_power dbr:Synchronous_converter dbr:Synthetic_inertia dbr:Virtual_synchronous_generator |
is owl:differentFrom of |
dbr:Grid-tie_inverter |
is foaf:primaryTopic of |
wikipedia-en:Synchronverter |