Sam's Laser FAQ - Home-Built Helium-Neon (HeNe) Laser (original) (raw)


Sam's Laser FAQ, Copyright © 1994-2022, Samuel M. Goldwasser, All Rights Reserved. I may be contacted via theSci.Electronics.Repair FAQ Email Links Page.


Sub-Table of Contents


Basic Home-Built HeNe Laser Information

Introduction to Home-Built HeNe Laser

The HeNe laser was the first one presented in the Scientific American Amateur Scientist columns only a couple of years after the invention of the laser and less than this after the invention of the HeNe laser! At least this one is designed to operate at the common visible 632.8 nm (orange-red) wavelength like that of common HeNe lasers found in high school physics labs and barcode scanners. (The original HeNe laser's output was in the IR portion of the E/M spectrum and quite invisible.) It is a very basic design as gas lasers go but due to the need for extremely low amounts of contaminants in the gas fill does require a decent vacuum system and some use of nasty chemicals (at least as described) including fuming nitric acid for cleaning the glass laser tube before evacuation and dry ice/acetone slurry for the cold trap!
Although one of the simplest in basic structure, given these requirements, the HeNe laser may not be the best home-built laser for the novice. In fact, it is deceptively simple and yet one of the most difficult gas lasers to construct from scratch. However, later in this chapter, we present a number of alternatives to the HeNe laser fully built from the ground up using beach sand and copper ore. Therefore, it is still possible to experiment with partially home-built HeNe lasers (beyond just wiring together a HeNe tube and power supply) using various proportions of your own ingredients without doing everything from scratch. :)
### Home-Built HeNe Laser Safety
There are two areas of safety considerations for the home-built HeNe laser (and other similar lasers, for that matter):
* Laser output: The home-built HeNe laser may be capable of producing a beam of up to 1 mW or more at several wavelengths. While 1 mW doesn't sound like much compared to, say, a CO2 laser, since there doesn't seem to be any hard information on the actual power obtainable with this or similar HeNe laser designs, it is important to take precautions assuming a higher power until determined otherwise. In addition, while the red (632.8 nm) wavelength is the one you are likely aiming for, HeNe lasers like to operate at several IR wavelengths including 1,152.3 nm, 1,523.1 nm, and 3,391.3 nm which are totally invisible but the first at least, is NOT eye-safe. Depending on the type of mirrors you use, accidental generation of the IR wavelengths, while not likely, may still be possible.
Take precautions to avoid eye contact with the direct or reflected beam, whether or not it is visible. This includes the 4 pairs of beams reflecting off the Brewster windows which may be quite strong.
* Electrical: The power supplies can be lethal. Neon sign transformer based power supplies have enough voltage and current to stop a heart, Even if you aren't killed, the shock may startle you into doing something you might regret. Make sure you read and follow the Safety Guidelines for High Voltage and/or Line Powered Equipment. Insulate all connections and install barriers to prevent contact with the high voltage.
Provide proper warning signs for both the laser radiation and high voltage. Keep pets and small children out of the area and make sure everyone present is instructed as to the dangers. The use of proper laser safety goggles for the specific wavelength(s) of your laser are highly recommended.
See the section: HeNe Laser Safetyfor more info. However, the home-built HeNe laser uses a different sort of power supply than CW commercial types (unless you are attempting something similar to one of these) so some of the specific details may not apply,)
For more information, see the chapter: Laser Safety and the more specific information in the section:HeNe Laser Safety. Sample safety labels which can be edited for this laser can be found in the section:Laser Safety Labels and Signs.
### HeNe Laser Construction References and Links
Finally, I have an excellent description with photos of a successful home-built HeNe laser constructed by John S. Rubacha while at Purdue University Calumet. This short paper covers the technical aspects as well as trials and tribulations of undertaking this project:
* Local Copy of J and K Laser Productions One Meter Helium-Neon Laser Tube. This used to be on the Lasershows 101 Web site, but are currently emphasizing their laser light show business and are no longer offering support to the hobbyist community. :( This would appear to be quite short-sighted given how many laser show enthusiasts and professional laserists began as hobbyists.
If anyone reading this has built (or even attempted) a HeNe laser from scratch, please send me mail via theSci.Electronics.Repair FAQ Email Links Page!
* The only other actual example of a successful home-built HeNe laser (beyond those described in the Scientific American articles) that I am personally aware of, was constructed by Mark Wilson:
(From: Mark Wilson (wilson_mark@htc.honeywell.com).)
> "When I saw the Scientific American article on building your own HeNe laser, I decided that I wanted to build it. The Scientific American HeNe laser was extremely difficult to build and I could not have done it without a lot of help. I got Spectra-Physics to donate a set of laser mirrors to me, a glass shop in my home town to help me cut and grind the Brewster window angles on the tube. The tube was made from lead glass from a sign company, and I also used neon sign electrodes. The optical rail was a 3 foot long piece of 2"x6" extruded aluminum that I got from a glass company which used this material to make doors for commercial buildings.
>
> I followed the directions in the Scientific American article to the letter. I sealed the microscope slides to the glass tube using flexible colodian that I got from a pharmacy. I filled the tube at a sign company which had He, Ne, Ar and other gases on a glass manifold. I assembled the laser and made the power supply using a mercury rectifier tube and a neon sign transformer. I got the tube to lase for a brief time, but since it was not a hard-sealed tube it quickly died probably due to helium diffusion. The tube would light up but not lase for a while then that too stopped."
* There were a few commercial HeNe lasers in the late 1960s and early 1970s that were constructed along the lines of the typical home-built HeNe laser. See Laser Equipment Gallery (Version 2.08 or higher) under "Assorted Helium-Neon Lasers" for the American Optical 3100 and Flavio's Antique HeNe Laser Photos Page.
* Also see the section: K. L. Vander Sluis et. al. HeNe Laser. His original research paper is: K. L. Vaner Sluis, G. K. Werner, P. M. Griffin, H. w. Morgan, O. B. Rudolph, and P. A. Staats, "A Simplified Construction of A Helium-Neon Laser", American Journal of Physics, Volume 33, Issue 3, pp. 225-240 (1965).
* K. G. Hernqvist and A. H. Firester, "Prealignment of Gas Laser Cavities" Rev. Sci. Instrum. 46, 1040 (1975) describes a technique for aligning sealed HeNe lasers where no adjustment is possible after completion.
* See the chapter: Laser and Parts Sources as some companies will sell laser mirrors and external cavity HeNe tubes (should you decide to only go half way!) but expect them to be pricey! I have several one-Brewster HeNe laser tubes for sale. These have an internal HR mirror with a Brewster window at the other end. I also have some two-Brewster HeNe laser tubes for sale. See the sections starting with: Sam's Instant External Mirror Laser Using a One-Brewster HeNe Tube.
* PHTN1432 Vacuum Systems and Thin Film Technology Lab #3: Reprocessing Laser Tubes is an example of a college course that includes this type of material, believe it or not.
* Also see the section: General Resources for Amateur Laser Construction.
* And, of course, before attempting to build your own laser, see the relevant chapters on basic principles and commercial systems starting with:Helium-Neon Lasers.
### Home-Built HeNe Laser Description
Although the helium-neon laser is one of the simpler gas lasers in existence, it is probably in the middle of the range of difficulty of home-built lasers discussed in this document and "Light and its Uses".
Refer to Typical Home-Built Helium-Neon Laser Assembly for a simplified diagram of the overall glasswork and power supply electronics.
* Level of difficulty (rated L=low, M=medium, H=high):
* Overall - M to H.
* Glass work - M.
* Fabrication (other than glass work) - M.
* Vacuum/gas handling - H.
* Power supply - L.
* Additional apparatus (optical mirror alignment jig) - M.
* Risks (high voltage, toxic chemicals, etc.) - M.
* Lasing wavelength(s) - 632.8 nm (red). There is also another line at 640.1 nm (red) which has a fair amount of gain and may work with the same mirrors. Operation at other visible HeNe laser wavelengths including 611.9 nm (orange), 594.1 nm (yellow), and 543.5 nm (green), may be possible but the gain at these wavelengths is much lower so almost *any* losses will kill oscillation (especially green - a functioning green home-built HeNe laser would be quite an achievement). IR output at 1,152.3 nm, 1,523.1 nm, or 3,391.3 nm should also be possible. The last in particular has the highest gain of any HeNe transition and in fact will lase without mirrors (superradiantly) in a moderately long tube. However, electronic detection of this wavelength isn't possible using common photodiodes and it's kind of boring unless you're doing research in mid-IR phenomena.
Operation at wavelengths more than a few nm away from 632.8 nm (except possibly for 640.1 nm) would likely require changing the mirrors to have their reflectivity peak at that wavelength (unless they are very high reflectivity broadband coated), and using the appropriate angle for the Brewster windows (or implementing an adjustable Brewster angle as described in conjunction with the Home-Built Pulsed Argon and/or Krypton (Ar/Kr) Ion Laser Laser).
* Resonator:
* Type/lasing medium - Low pressure mixture of He and Ne gas.
* Bore diameter - 2 mm; bore length - 34 cm.
* Total tube length (to center of the Brewster windows) - 45 cm.
* Tube material - Glass, type not stated.
* Electrodes - Cold cathode type using neon sign electrodes or small aluminum cylinders. These are mounted in side-arms or in side-side-arms. The use a of larger side-side arm with a large can style aluminum cathode might permit the laser to be run on a normal HeNe laser power supply.
* Gas fill - 7:1 ratio of He:Ne at about 2.5 Torr.
* Cooling - Convection air. Increased cooling is of little value.
* Coupling - Corning 7940 glass. The authors also mention the use of quartz to minimize heat losses and the Brewster angle they specify of 32.8 degrees from the axis is consistent with quartz (crystalline, not fused). I don't know whether these materials are the same. However, see below for a possible reason to use borosilicate glass instead of quartz.
* Mirrors - Dielectric, concave, RoC = 60 cm. Three-screwAdjustable Mirror Mount at each end. Reflection coefficient not stated for either mirror. Alignment using flash light bulb and beamsplitter apparatus (described in article).
* Total resonator length (mirror face to mirror face) - 57.5 cm.
* Vacuum system:
* Requirements - medium. Article calls for 10-5 Torr which would be nice but perhaps not essential.
* Sealed tube operation but limited life (perhaps 50 hours) before regassing is required.
* Special chemicals/supplies required - Fuming nitric acid to clean laser tube glass parts before evacuation/baking/backfill.
* Excitation/Pumping:
* Type - Electrical discharge.
* Power supply - 9,000 VRMS, 18 mA neon sign transformer and Variac. The maximum optical output power was at 85 percent of full voltage.
H o----------+ T1 T2 +---------o HV AC
)|| ||=||(
Variac )<--------------+ || ||(
0-115V )|| )|| ||(
5A )|| Neon Sign )|| ||( Well insulated
)|| Transformer )|| || +---+ HV wires to HeNe
+--+ 9kV,18mA )|| ||( | tube electrodes
| )|| ||( |
N o-------+-------------------+ || ||( |
||=||( |
| | +---|-----o HV AC
| | |
G o-----------------------------+---+-----+
|_
////
### Guidelines to Assure a Successful Home-Built HeNe Laser
These set of guidelines should be followed during construction of your first home-built HeNe laser. The factors below will greatly influence the ultimate output power, beam quality, and whether it produces any coherent light at all! Once you have a working laser, feel free to make modifications - one at a time. Thanks to George Werner (glwerner@sprynet.com) for his comments.
* Use the proper diameter thick wall capillary and assure that it is straight. A smaller diameter than used in the SciAm HeNe laser may be beneficial, say between 1 and 1.5 mm. This will both increase the gain (which is inversely proportional to bore diameter) as well as help to assure a TEM00 beam profile. A larger bore will tend to operate with multiple longitudinal modes (which you may find interesting as well). Slight warp or sag of the capillary can be adjusted with intermediate bore supports. Avoid the temptation to just use a narrow thin wall tube which would make the entire assembly very fragile.
However, there are two disadvantages to using a narrow bore:
1. It will result in a higher operating and starting voltage which should be taken into account in your power supply design. (Or, cheat and use a commercial HeNe power supply compatible with a tube of similar length while testing your laser.)
2. Alignment using the card method will be more difficult.
* The small capillary in the larger tube approach as presented in the SciAm article may be a bad idea for two reasons:
1. Any gap between the inner and outer tubes will result in structural instability.
2. The discharge may bypass the inner capillary entirely (particularly with a narrower bore) which would be bad news indeed.
I would recommend a one piece approach instead, with a thick-walled capillary fused directly to glass extensions (as used in the Vander Sluis et. al. paper) if your glass working skills and/or budget are up to it (or glued to metal extensions if using the no glass working approach).
* Obtain good quality glass optical flats for the Brewster windows. They should be at least 1 mm thick to minimize distortion from the vacuum (not microscope cover slips!). These don't have to be expensive - plenty of low cost surplus optics is available. While some microscope slides might work, there is no real way to be sure before your entire laser is assembled and then it is too late to change. Any candidate Brewster window should pass the following tests:
1. When viewed edgewise, it must NOT have a greenish (or other color) tint.
2. When you hold it at arm's length and view something across the room through it, there should be no detectable magnification or minification.
3. When viewed against a black background in a concentrated light beam (such as sunlight passing through an f/4 concentrating lens) it should show very little scattering of light (from incomplete cleaning or incomplete polishing).
No other aspect of the laser tube assembly itself is as important as the quality of the Brewster windows to the ultimate outcome of this project! While, certain types of distortion won't prevent lasing (some may even make it more exciting with complex mode structures), this is a complicating factor your first laser can do without.
The author of the SciAm article suggests the use of quartz instead of glass to minimize heat losses but that material has a high transmittance at the 3.391 um IR wavelength which interferes with operation at 632.8 nm (and other visible wavelengths). If you insist on quartz (perhaps to have the option of 3.391 um operation in the future), also obtain a pair of glass flats to add outside the tube to kill that line. If you do try lasing at 3.391 um, aluminum mirrors should be fine. This line will even lase with no mirrors (superradiantly) in a long enough tube.
* Cut the ends of the laser tube to accept the Brewster windows only_>after
all glass working (including annealing) has been performed as these steps may affect the angles enough to increase losses. Take care that the angle is close to the correct value for your window material (33.3 to 34.2 degrees from the beam axis for most window materials) with their perpendiculars as close to parallel as possible. (An error of up to 1/2 degree is acceptable in both cases. The ball-and-socket approach of the SciAm pulsed Ar/Kr ion laser can be used instead to provide some adjustment range but this really isn't needed.) Use the /===\ arrangement, not /===/ (which will shift the optical axis). Make sure the inside surfaces of the windows are immaculately clean before installation! They can't really be cleaned properly once attached to the tube.
* Mount the electrodes in side-arms well away from and with no line-of-sight to the Brewster windows. This will minimize the deposit of a metallic film on the Brewster windows due to sputtering (particularly at the negative electrode).
* Don't skip the essential cleaning step before final assembly of the Brewster windows to the laser tube. This will greatly reduce the amount of bake-out required once you are under vacuum. It will still be necessary to pass a high current through the tube in both directions for some time as well as running a low temperature torch over areas that aren't heated enough by the discharge. However, the amount of outgassing and required time will be greatly reduced.
CAUTION: Apparently, it is possible for an electron beam to be produced from the positive electrode during the high current bake-out step which can quickly melt a hole through the tube wall opposite the side-arm if left running for more than a few seconds. The visual effect will first be a spot of bright yellow sodium light from the point of impact. Use lower current and/or make that area of the tube (the outside of the turn) much thicker.
* Obtain proper laser resonator mirrors. Sorry, you can't make these in your basement. Don't even bother to try silvered or aluminized mirrors (e.g., from barcode scanners), at least not until you have the laser working with real mirrors.
* The HR should have as high a reflectivity as possible and the OC should have about 99 percent reflectivity (assuming the 34 cm or so active bore length), both at 632.8 nm. If your laser is longer, the OC reflectivity can be reduced slightly but starting with 99 percent will work well, if not being quite optimal. Or, if you would like to have beams from both ends or identical mirrors are much cheaper, they can both be 99.5 percent. For initial testing, the use of a pair of HR mirrors will result in the lowest threshold and the highest likelihood of lasing if something else is marginal. Once you see the (coherent) light, a proper OC can be installed.
* Their Radius of Curvature (RoC) should be between L and 2*L, where L is the distance between mirrors. An RoC of L will result in a confocal cavity which has a number of attributes including being relatively easy to align. An alternative which may be desirable is to implement a folded confocal cavity with an RoC of 2*L for the HR and infinity (planar) for the OC. But note that using a value of exactly L or 2*L, respectively, results in an marginally stable resonator, so the RoC(s) should be a few percent shorter or longer. See the sections: Mirrors used for Lasers and Laser Applications andMirrors for Home-Built Lasers for more info.
* Mirrors salvaged from commercial HeNe laser tubes will be satisfactory if their RoC and reflectivities are as described above. Those from short tubes will have RoCs that are too small and won't do anything useful. The OC from a long tube may have a reflectivity that is too low. Mirrors from a large-frame HeNe laser would probably be suitable though their RoCs will be long making alignment more critical.
* Mount everything on a stable base and make sure your mirror mounts have adequate precision! No amount of fiddling will compensate for mirrors that change position on their own. Yes, it may be possible to assemble a working laser mounted on wobbly stands but this isn't recommended!
* Unless you want to be faithful to the era when the first HeNe laser was built (and there were no other lasers handy), I'd recommend using another HeNe or collimated diode laser to perform the mirror alignment. Mount the alignment laser to the baseplate so that it will be there whenever you need it. Do the initial alignment once everything is assembled but before actually evacuating the system and filling it with the HeNe gas mixture. Then, you'll be ready to lase, or at least very close. The card method of alignment can also be used but may be a bit tougher with the recommended narrower bore.
* Use spectroscopic grade premixed HeNe gas with a 7:1 to 10:1 ratio (partial pressure/molar). Party balloon helium won't work due to gross amounts of contamination. The purity of the gas fill is extremely critical as the HeNe laser's performance drops off like a rock with even small amounts of N2, O2, H2, and other non-He and non-Ne constituents. As little as .01 Torr of H2 in your 1 or 2 Torr tube will kill lasing entirely.
* If you are determined to seal off the tube after the laser is functional, run it for several hours while still connected to the vacuum system and continue to monitor and adjust the pressure during this time. The electrodes will act as getters of sorts and will remove unwanted non-inert gases as well as some of the helium and neon, necessitating refilling. Then, perform the seal-off without powering down - this will insure that conditions are correct at the normal operating temperature. Don't forget the very critical act of offering the proper chants and incantations to the "gods of newly born lasers" - though I don't know how much this really helps! :)
* Make sure you read, understand, and follow ALL the safety guidelines found in the section: Home-Built HeNe Laser Safety.

Other Examples of Home-Built HeNe Lasers

K. L. Vander Sluis et. al. HeNe Laser

The following isn't quite a home-built laser but would be the equivalent in the early 1960s - one of the first visible HeNe lasers on the planet:
(From: George Werner (glwerner@sprynet.com).)
> "I have read with interest your wealth of information on home-built HeNe laser because every problem you dealt with was one that we grappled with about forty years ago. I was a member of a group here in Oak Ridge that built the first HeNe laser in Tennessee about six months after Bell Labs announced the construction of theirs.
>
> Back in the 1960's we had a laser development group that decided that before we came out with a new kind of laser we should get laser experience by building one (HeNe) like Bell Labs. Ken Van der Sluis was the principal investigator. His prior experience with resonators was with the Fabry-Perot (FP) interferometer, so much of our construction was adapted from FP construction. The reflectors were 5 cm diameter in mountings that used 1/4 - 80 threads on the adjusting screws and Invar rods to maintain spacing, a case of overkill on every turn.
>
> The finest window material we had were quartz FP flats 5 cm diameter x 1 cm thick, and these were cemented onto the Brewster-cut tube ends. Ken was measuring gain with a spectrometer, adjusting mirror angles, gas mix, gas pressure, and discharge current, trying to find the magic combination but with no luck. Then Ken realized that it was possible that the infrared transition at 3.391 um was depopulating the upper level of the transition we wanted to use. After adding a borosilicate crown glass (BSC) flat (which blocks 3.391 um) to one of the windows with masking tape, and some realignment of the mirrors, it wasn't long before he got the first spark of red light - the first HeNe laser light in Tennessee! Soon word got around and for the next day or two we had dozens of visitors to see this fascinating red sparkling light. (It was our opinion that Bell Labs did not know about the 3.39 um trap and that they were lucky to have tried BSC first.)
>
> The lasers we made were made to get that sparkly red light and we were not concerned about the mode structure (except for our theoretical physicist who was fascinated by all the different multi-mode patterns we could get with our wide bore tube and he had names for them all). In fact, we soon abandoned using thick Brewster windows with optically flat surfaces, and sometimes used ordinary microscope slides.
>
> This work led to our development of a demonstration laser which we took to universities and a few high schools mostly over the eastern United States, and also to South America and Hungary.
>
> Everything can be found in the paper: "A Simplified Construction of a Helium-Neon Visible Laser", by K. L. Vander Sluis, G. K. Werner, P. M. Griffin, H. W. Morgan, O. B. Rudolph, and P. A. Staats in the American Journal of Physics, vol. 33(3), pp. 225-240, March 1965.
>
> (Here is another paper from the same group at Oak Ridge National Lab that should probably be in another chapter but I put it here: "Conversion of a Simplified HeNe Gas Laser to Pulsed Operation with Ar, Kr, and Xe", H. W. Morgan, P. A. Staats, P. M. Griffin, G. K. Werner, and K. L. Vander Sluis, American Journal of Physics, vol. 37(9), pp. 938-939, September 1969. --- Sam.)
>
> My most important contribution to the effort was that I was the inventor of the Laser Alignment Card, which you allude to later in this chapter. I could go on for several pages talking about lasers. We old-timers love to talk and reminisce!"
(George has since gone on for several pages talking about lasers and has contributed several sections relating to the home-built HeNe laser, amateur laser construction in general, and other laser topics.)
The HeNe laser presented in the paper is very similar to the SciAm design which isn't terribly surprising given that it was published in the same time frame. A photo in the paper shows the minimalist approach to laser design - the laser tube as well as the resonator mirrors supported by chemist's burette clamps on wobbly ring-stands with a Tesla-type leak tester for excitation! Well, maybe. Some of may partially home-built laser test rigs were a lot less stable. :) OK, this isn't what they recommend building (or what is described more fully in the paper and below) but it was included to drive home the point that you don't need a lot of sophistication to construct a working laser.
I really liked the suggested supplier list (with 1965 prices!) which was thoughtfully included with my copy of the reprint of the paper. Optical windows for 25 cents; 1 liter flasks of He:Ne gas mixture for 6.50,and(small)neonsigntransformersfor6.50, and (small) neon sign transformers for 6.50,and(small)neonsigntransformersfor9.95. If only these companies were still n business today (using those same prices)! What I would give for a working time machine. :) One interesting thing is that while some items were quite inexpensive (if inflation wasn't taken into account), the dielectric mirrors were priced quite high - after all, this was new technology! And similarly, semiconductor rectifiers, which are dirt cheap today, were 10 or 20 times as expensive in 1965 dollars - much much more if inflation is included.
There is one piece of information that can be inferred from the paper that is lacking from all of the SciAm articles: The actual optical power output. Based on their use of a silicon photodiode detector, I expect that it peaked in the .5 to 1.25 mW range depending on gas fill ratio and pressure. This assumes a photodiode current sensitivity of .4 to .5 mA/mW. Note that this was with mirrors that were about half as efficient as modern ones (they had significant absorption losses) and they were both OCs so an equal mount of power exited both ends. Thus, it would appear that up to about 5 mW may have been possible by using a modern HR/OC pair. Maybe I could use that time machine to take them a set. :)
Here is a description of the HeNe laser presented in the paper summarized in my standard format. Some of the dimensions below were estimated as there is no dimensioned drawing in the paper. The authors suggest a variety of possible modifications as well. While the title of the paper implies a simplified approach, the authors did have access to a decent machine shop (including lathe and diamond cutoff wheel) and glass working shop (the glass fabrication looked perfect). However, like the SciAm lasers, this really isn't essential.
* Level of difficulty (rated L=low, M=medium, H=high):
* Overall - M to H.
* Glass work - M.
* Fabrication (other than glass work) - M.
* Vacuum/gas handling - H.
* Power supply - L.
* Additional apparatus (optical mirror alignment jig) - M.
* Risks (high voltage, toxic chemicals, etc.) - M.
* Lasing wavelength(s) - 632.8 nm (red). The authors mention other visible wavelengths but don't elaborate on these. They do suggest the IR wavelengths as well as superradiant operation at 3,391 nm.
* Resonator:
* Type/lasing medium - Low pressure mixture of He and Ne gas.
* Bore diameter - 2-1/4 to 2-3/4 mm ID, 7 mm OD; bore length - 36 cm.
* Total tube length (to center of the Brewster windows) - 44 cm.
* Tube material - Borosilicate (Pyrex) glass.
* Electrodes - Cold cathode type using neon sign electrodes. These are mounted in side-arms.
* Gas fill - 5:1 to 10:1 ratio of He:Ne at about 1 to 3 Torr. A 1" x 6" test tube is fused into a side-arm to act as a gas ballast (expansion chamber and gas reserve).
* Cooling - Convection air.
* Coupling - Borosilicate windows, Brewster angle = 33.7 degrees from axis. Authors specifically warn against using quartz as it passes the (generally) unwanted 3,391 nm wavelength with little attenuation.
* Mirrors - Dielectric, concave, RoC = 1 m. Reflectivity: 99.5% (0.2% transmission and 0.3% absorption - yikes! - for their specific samples). Their mirror mounts are higher precision versions of the SciAm design or the ones shown in Adjustable Mirror Mount Alignment using the "card with pinhole" approach described in the section: Comments on Alignment Procedure in "Light and its Uses" (invented by one of the authors of this paper, George Werner).
* Total resonator length (mirror face to mirror face) - 60 cm.
* Vacuum system:
* Requirements - medium. Paper suggests that 10-3 Torr. A well maintained two stage mechanical pump may be capable of this and will certainly do better than 5*10-3 Torr which should be close enough. However, their system also had a diffusion pump and was capable of 10-6 Torr.
* Sealed tube operation but limited life (perhaps 50 hours) before regassing is required. The authors suggest filling the tube at a somewhat higher pressure (which reduces output slightly) to extend life.
* Special chemicals/supplies required - Weak hydrochloric acid and alcohol to clean laser tube glass parts before evacuation/baking/backfill.
* Excitation/Pumping:
* Type - Electrical discharge.
* Power supply - Variac and three, 3,000 VRMS, 18 mA neon sign transformers in parallel (for higher current) feeding voltage doubler/filter and adjustable ballast resistance. The diagram below is simplified with some parts combined into one. Their circuit diagram also included a door interlock activated bleeder resistor!
D1 R2 Rb
H o-------+ T1 T2 +-----+--|>|--+--//--+--//--+--o HV+
)|| ||=||( | 10KV |25K 20W | |
Variac )<--------------+ || ||( | _|_ C1 | |
0-115V )|| )|| ||( | R1 --- .25uF | v Spark gap
5A )|| Neon Sign )|| ||( | 170 | 2KV _|_ C3 ^ 4KV
)|| Transformer )|| ||( +--|-//--+ --- .1uF |
+--+ 3kV,54mA )|| ||( | | 5W | C2 | 5KV \ R7
| )|| ||( | | _|_ .25uF | / 50K
N o----+-------------------+ || ||( | | --- 2KV | \ 10W
||=||( | | D2 | | |
| | +--+ +--|<|--+--------+--------+--o HV-
| | 10KV
G o--------------------------+---+
_|_
////
As noted, T2 is actually three, 3 KV, 18 mA, neon sign transformers wired in parallel to obtain the 54 mA current rating. Rb, the ballast resistor, consists of 4, 25 K, 20 W resistors in series with taps to adjust the tube current.
Note that the voltage ratings of C1 to C3 are marginal at best. Should the spark gap fail, the output voltage could easily climb to nearly 10 KV.
### Andrea's Home-Built Helium Neon Laser
As of Summer, 2012, Andrea Verniani (verniax@gmail.com) has successfully completed a HeNe laser from scratch. This is only one of fewer than a half dozen that I've actually heard of. Here are the vital specifications/description:
* Laser tube material: Borosilicate hard glass
* Brewster window material: Fused silica.
* Electrodes: Borosilicate neon sign electrodes.
* Tube length: (window to window): 50 cm.
* Active zone length: 27 cm.
* Active zone inside diameter: 2 mm.
* Laser gas mix: High purity Helium and Neon at a ratio of 9:1.
* Laser gas pressure: 2.5 Torr.
* Vacuum system: Two stage roughing pump and air-cooled diffusion pump.
* Mechanical: Home-built glass lathe, home-built 70 cm bake-out oven.
* Induction heater for electrode activation treatment.
* Operating voltage 3.2 to 4.0 kV.
* Operating current 4.0 to 13.0 mA, 7.0 mA is best.
* Estimated maximum power: 1.5 mW (Hemispherical cavity).
* Mode of operation: Multimode or TEM00 depending on optics.
And some photos:
* Andrea's Home-Built HeNe Laser Tube after fabrication but before gas fill and sealing.
* Andrea's Home-Built HeNe Laser in Operation.
* Closeup of Intra-Cavity Beam in Andrea's Home-Built HeNe Laser.
See Andrea's Home-Built HeNe Laser Video 1 (MP4) andAndrea's Home-Built HeNe Laser Video 2 for all the exciting action! OK, so they may not be_that_ exciting beyond knowing this was built from scratch. :)
### Terry Michaels' Home-Built HeNe Lasers
(From: Terry Michaels.)
Unfortunately I don't think that I have any photos of the lasers that I built, which in retrospect I now regret. I guess that I just didn't think of taking photos of them or didn't think that what I was doing was noteworthy enough to do so. I started out by going to the Milwaukee Public Library and looking through as many gas laser patents as I could find so that I could get an idea on what had been done already. I bought some lengths of glass capillary tubing from a local supplier, Pope Scientific, along with some Pyrex to Kovar pre-made tubular transitions. I cut the Kovar at the Brewster angle and fused the glass-end of the transition piece to the end of the capillary tubing, then epoxied a window onto the Brewster angle-cut Kovar which formed the anode-end of the tube. For the cathode I cut a piece of heavy wall aluminum tubing about 1-3/4" in diameter and a foot long, and cut two aluminum discs to fit the ends with a hole drilled in each one the size of the outside of the capillary. I had a local welder weld the two end-caps onto the tubing. I found some very high strength, one part, temperature curing Epoxy, pushed the capillary into one end of the cathode, pushed a piece of glass tubing that was cut at one end at the Brewster angle into the other end of the cathode and sealed both joints with the Epoxy. I don't exactly remember how I did the connection to the vacuum system, it might have been through another glass tube going into another hole drilled in the cathode. The tube was mounted in a heavy length of aluminum angle stock. I fabricated end-plates with adjustable 3-point adjustment screws with tensioning springs for alignment. I was fortunate to be in Milwaukee doing this because after visiting several scrapyards I found many of the needed items. Milwaukee is home to GE Medical which was ultimately the source of some things I needed, including an oil diffusion pump which they had thrown in the scrap. The main part of the vacuum system was a '30s vintage single stage, belt driven mechanical pump called a "Rollator" which was originally used in a refrigeration system, and the oil diffusion pump. I used an HR mirror from a dead HeNe tube and I bought an output coupler and two windows from Spectra Physics. I bought a spherical flask of premixed helium and neon from someplace that I don't remember now, you had to glass-in the stem of the flask into your vacuum system and then break a small tipoff inside with a steel rod that you would manipulate from the outside of the glass with a magnet. After putting all of this together over many weeks of work, one night I got it to put out some red light. I remember being very surprised after many hours of tinkering with the gas fill and the alignment to see it actually working.
A year or two later I built a larger laser, a split discharge version. By this point I was attending the University of Wisconsin for an E.E. degree had got to know someone on the staff there who was an amateur glass blower. He had a reasonable assortment of glass blowing equipment in his basement and was kind enough to allow me to visit a few times to put together the larger tube, and he also provided some assistance. He was mainly into doing decorative and artistic glass work but he same basic methods applied to what I was doing. The larger tube did somewhere around 60 mW but that was a guess as I didn't have a calibrated meter at the time.
That tube and the previous tube both had the problem of a gas fill that wouldn't stay clean enough to be useful for more than a few weeks at best. This was because the tubes had a number of epoxy joints and the vacuum was maintained by a lab type glass valve sealed with high vacuum grease, the valve was needed so I could disconnect the laser from the vacuum system and move it around. I actually used the laser at some laser shows. So I commissioned Don Gillespie at Eldon Engineering to make a professionally manufactured and well sealed tube which was essentially a clone of what was used in a S/P 125. I now had access to some better shop equipment and machining tools and equipment at my current job so I was able to make a lightweight resonator frame using 3 Invar rods. The laser tube plus IR suppression magnets were mounted to an aluminum angle which was mounted inside the Invar resonator with bearings in a 3 point kinematic configuration. It put out more than 90 mW. This was the last laser I built, I probably have some photos of it because unlike the earlier lasers that I built which I just gave away or tossed out after I had move on to something bigger, the last HeNe I sold on eBay when I disposed of the rest of my laser business in the year 2000.
Hope this wasn't too long of a narrative to read through but I never had a reason to write any of this out before and this was a good opportunity to do so.
### Cristiano Perrucci's Home-Built HeNe Lasers
Now these are what one would call home-built lasers. Even some of the support equipment is built from scratch! And not just one working tube, but two working ubes so far. ;-)
Many photos of the HeNe laser construction effort can be found atCristiano Perrucci's Home-Built HeNe Laser 1. This opens in a new window or tab depending on your browser's settings.
(From: Cristiano Perrucci.)
The construction of a HeNe laser requires good manual skills and good knowledge of glass processing, both for the realization of the tube and for the realization of the electrodes and their relative tungsten feed-throughs. For those interested in starting glass work I suggest the book "Laboratory Scientific Glassblowing - A Practical Training Method" Paul Le Pinnet (sold by Amazon).
In addition to skills, a variety of equipment and tools are also required to achieve the goal. Most of the more expensive and difficult to find equipment concern the vacuum and gas supply system.
Finally, the sharing of information and knowledge is crucial as in all human challenges. When in 2012 I started my project of a home-built laser from scratch, my knowledge of vacuum production and glassblowing was absent. Fortunately, I had already had experience in making a home-built ruby laser and I was aware of the difficulties that awaited me.
I have divided the overall project into three sub-projects that are certainly more manageable both from an economic and a temporal point of view:
1. Collection of information, books and publications.
2. Acquisition of skills in glassblowing including glass-to-metal seals, construction of specific tools for fabricating the laser tube.
3. Acquisition of minimal skills and knowledge in vacuum production and management including construction of equipment and measurement systems such as butterfly valves, vacuum gauges, etc.
From my point of view the most difficult, expensive and demanding part of the whole project is the realization of an efficient and reliable vacuum system. In my specific case, for the vacuum production I used a diaphragm pump followed by an Alcatel 5011 turbo-molecular pump, this system is able to reach a pressure of about 10-6 mbar, low enough to process a HeNe laser.
The rest of the vacuum system was made with copper pipes and machined brass pieces to make the connection flanges and valves
Now we come to the actual construction of the laser
After several attempts, I decided to divide the tube construction into four steps:
1. Construction of the plasma tube with both ends cut at the Brewster angle.
2. Construction and testing of the electrodes.
3. Final assembly and leak test.
4. Vacuum processing and introduction of the gas charge.
This approach proved to be successful since in case of failure in the realization of each single part, it could be replaced without compromising the rest of the structure. In particular, the realization of working electrodes required several attempts, so the choice to test them in the vacuum system before integration into the plasma tube was an excellent strategy.
The main tube was made using a 7 mm capillary with a 3 mm bore (7x3mm), about 40 cm in length. Two 8x5mm lengths of glass tube, each about 10cm in length were fused to the ends.
The cathode was made using a 0.3 mm thick aluminum sheet to which a 0.5mm diameter tungsten wire was connected and worked to create vacuum-proof feed-through. The anode is a standard electrode for neon signs welded to a tungsten vacuum-proof feed-through.
Once the electrodes were made, they were tested in the vacuum system with a Tesla coil to verify their tightness.
Now that all the components were ready they were assembled to make the laser.
A very important, maybe essential, practice is to anneal the tube before cutting its ends. The annealing procedure allows the glass to release the mechanical stresses created during cooling after glassworking, these stresses could create micro fractures and therefore air leaks.
The ends were then cut at the Brewster's angle.
Before installing the windows, the whole assembly was washed several times with clean acetone to remove traces of grease and glass residues and finally "roasted" for a few hours at about 330 °C in an oven. This process has two functions: To burn all the organic residues that have been deposited during glassblowing as well as dust, and to release the moisture adsorbed by the internal glass walls.
As soon as the tube had cooled down, the windows were glued using UV glue and immediately evacuated to check for leaks.
The tube was then ready the final stage.
Since the UV glue does not withstand the high temperatures required by the vacuum procedure, a dedicated oven was built for this operation. This oven, shorter than the entire tube length, allows the electrical discharge area to be brought to a high temperature but to keep the windows at room temperature.
The laser was then processed mixing the indications provided by the Russian patent: RU2713915C1 "Method of producing oxide film of cold cathode of gas laser in glow discharge of direct current", by the US patent US3860310 "Method for Fabricating Gas Laser", the book "Gas Laser Technology" by Douglas C. Sinclair and W. Earl Bell and of course "Light and its Uses" edited by Scientific American.
Essentially the cathode is oxidized as well described in the patents and subsequently it is evacuated and the vacuum is maintained for several hours before filling with the final gas mixture.
Here is a quick description of my homemade vacuum system parts:
**Technical data:**
* **Glass type:** Borosilicate (Pyrex).
* **Discharge length:**400 mm.
* **Bore diameter:** 3 mm.
* **Plasma tube overall length:** ~55 cm.
* **Anode:** Modified standard nickel neon sign electrode.
* **Cathode:** Hollow homemade aluminum cathode.
* **Brewster windows:** Fused silica.
* **Mirrors:** HR >99.9%R, planar; OC 1%T, 1,250 mm RoC.
* Resonant cavity length: 670 mm.
* Operating current: 4 to 12 mA (>5.5 mW at 7.5 mA).
* Output Power: 5 mW multimode.
* Wavelength: 632.8 nm.
* Testing time: Greater than 200 hrs over 15 days so far.
Laser Construction Description Here are the detailed steps of the construction of the laser as well as the refurbishment of the glassworking torch, fabrication of the gauges.
The following pictures are of the torch used for blowing all glass parts. It is a professional home-refurbished German glass-blowing torch made in the 1960s by the Arnold Company.
* Glassworking Torch: This was the Arnold torch in its original condition.
* Torch Parts and Accessories: Torch disassembled for cleaning.
* Torch Idling: Looks nice after refurbishment.
The following pictures are of a home-made McLeod Vacuum Gauge for calibrating a home-made Penning gauge and a home-made oil-filled U-Tube manometer I made for filling the plasma tube with rare gas.
* McLeod Gauge Glasswork:
* McLeod Gauge Ready:
* McLeod Gauge Plaque: ;-)
* Penning U Tube:
The following pictures relate to the construction of the actual laser tube.
* Preparation of Glass Tubes and Electrodes:
* Finished Electrodes:
* Annealed Glass Strain Check with Polariscope: Note that glass MUST be annealed to avoid cracks due to thermal stress.
* Glass Tube Assembly in Progress:
* Hand-Cutting the Brewster Angle: Both ends are hand cut at Brewster angle calculated for fused silica windows (34.5 degrees).
* Fused Quartz Window Attached to Tube End: Windows are now mounted on the tube ends.
* Leak Test on Vacuum System: The assembled tube is connected to the vacuum system to check the presence of leaks.
* Tube being Baked: The tube is baked for several hours in order to eliminate any trace of organic impurities/contaminants.
* Cathode Processing: Aluminium cathode is processed to create a thin layer of oxide on its surface. This is crucial for tube lifetime.
* Tube Processing: Glow discharge helps to remove contaminants such as water vapor and organic residues.
* Anode Induction Heating 1: Induction heater is used to degassing anode before rare gas filling.
* Anode Induction Heating 2:
* Tube Filling with HeNe Gas Mixture: Tube is filled with proper gas mixure.
The following pictures relate to the assembly of the overall laser.
* Overall Laser Assembly: The plasma tube is mounted on the resonant cavity. This is a standard optical configuration with a planar HR and 125 cm RoC OC. The distance between the mirrors is 65 cm. fine tuning of mirror alignment allows for the selection of various transverse modes.
* Laser Powered 1: This is the second (working) tube I made. Note that the window on the right is perpendicular to the tube axis. Here I used a BK7 AR-coated window instead of a fused silica one. Although losses are greater compared to a Brewster angle window cut, the tube still produce laser radiation.
* Laser Powered 2: Tube during aging tests.
* Laser with Output Beam 1: Laser beam produced during very first mirrors alignment.
* Laser Powered 3: This is the first working tube right after its first minutes of life. Note the two Brewster windows.
* Brewster Scatter 1: Close-up of the window near the OC.
* Brewster Scatter 2: Another close-up of the same window.
* Brewster Window and Mirror 1: Close-up of the window, OC and homemade mirror mount.
* Brewster Window and Mirror 2: Another close-up of the window, OC and homemade mirror mount.
* TEM00 Mode: By putting a piece of cardboard with a 1.5 mm diam hole between the OC and the respective window, it is possible to get a nice TEM00 profile.
* TEM20 Mode: By tuning the mirror alignment it is also possible to select a variety of transverse modes.
* TEM10 Mode: Another one.
* TEM*10 Mode: And a doughnut mode.
* Plasma Tube with Perpendicular instead of Brewster-angle Window: This tube is a successful attempt to use an AR coated perpendicular optical glass in place of a Brewster end.
* Microscope Slides near Brewster Angle: This is a stack of three microscope slides angled at quasi-brewster angle. This experiment shows that losses introduced by the three slides (plus the two embedded fused silica windows) are so little to induce me to use them as Brewster windows for the next tube I'll make. A pair of good fused silica optical flats costs about 60,twogoodqualitymicroscopeslidescostslessthan60, two good quality microscope slides costs less than 60,twogoodqualitymicroscopeslidescostslessthan1. For everyday experiments, microscope slides could be a good deal.
Here is a short YouTube video of lighting of the laser:Cristiano Perrucci's Homemade HeNe laser (all from scratch, not commercial tube) - YouTube.
Details of One-Brewster Laser Tube:
* Glass envelope: Hard glass (Pyrex).
* Bore diameter: 1.9mm.
* Output window: high quality 15mm diam, 2mm thick UV Fused Silica cod.WFS-152 (*)
* Output (Brewster) window angle: 55.5 degrees.
* Feed-throughs: 0,5mm pure tungsten wire.
* Anode: 0,15mm x 8mm pure nickel sheet (**).
* Cathode: 0,5mm oxidized aluminum sheet (**).
* HR mirror: Pre-aligned 6mm diameter HR Planar.
* He-Ne ratio: 7:1.
* Pressure at 30°r;C: 3.5 Torr.
Both Output Window and HR Mirror are glued to the plasma tube ends using a UV curable cyanoacrylate glue (***). The ends are then strengthened with Hysol-1C glue.
Notes:
1. The Storage/Operating temperature is -40/+35 Celsius.
2. NEVER exceed +40C or permanent damage will occur due to glue outgas
3. Clean the Output Window with acetone or IPA, be very careful not to wet the glue.
4. This specific plasma tube worked for 300+hrs before shipping. Using a 120 cm ROC 1% OC I've got 2 mW. multimode @4,5mA DC current. Output power is very sensitive to window/OC cleaness
(*) UV-Fused Silica Windows.
(**) Avaliable on Amazon.
(***) Almost Worldwide available (BLUFIXX in the USA)

Additional Information on Home-Built HeNe Lasers

Estimate of Home-Built HeNe Laser Output Power

Given our knowledge of the construction of a modern HeNe laser tube and the type of power supply used, it isn't surprising that the available output power from this 35+ year old design will be less than optimal - probably a lot less!
A modern tube with a 34 cm discharge length would be rated about 5 mW when run from a normal HeNe laser power supply (DC, constant current).
* The actual bore of the HeNe laser from "Light and its Uses" is 34 cm in length with an ID of 2 mm. For its ID, this is rather short for a modern HeNe tube even if it is a multi-mode (non-TEM00) type. This is certainly going to affect efficiency but I have no way of really estimating by how much.
For an HeNe tube, a wider bore doesn't necessarily permit higher power since the walls of the capillary apparently are important in depopulating higher energy levels. Gain actually decreases (inversely) with increasing bore diameter. I will assume that this is really equivalent to a 1 mm bore in a modern tube (and this may be optimistic).
Loss factor: .5.
* The power supply for the home-built HeNe laser is AC from a 9,000 V, 18 mA (current limited) neon sign transformer run at about 85 percent input so it would probably be outputting about 7.65 kVRMS (10.8 kV peak, no load). On each cycle, the discharge will occur once the voltage across the tube exceeds a several kV, possibly 5 kV or more. Thus, a large percentage of each cycle is wasted.
Loss factor: .5.
* Once the tube starts conducting, the current will be limited to 18 mA but may not actually be anywhere near constant. The characteristics of the typical neon sign or oil burner ignition transformer is NOT a particularly good constant current source (though better than would be expected from a 'normal' transformer. The actual current in the tube will be varying quite a bit during the period when it is conducting. There is no way to know (without testing) over what portion of this variation the current is optimal or if the laser is even outputting at all! HeNe lasers only produce an output beam over about a range of current of 2:1 or 3:1 and the portion of this range where output is optimal (with minimal detectable change in intensity) may be much smaller. In fact, an output may be occurring mostly on some short portion of the rising and falling edges of the AC waveform!
Loss factor: .5.
* Losses due to the Brewster windows, impure gas fill, quality (or lack thereof) of the mirrors, and so forth, will reduce output still further.
Loss factor: .5.
Funny how all the 'loss factors' are the same, huh? Can you spell: WILD GUESSES?
Based on these considerations, I would be surprised if the original design produced more than .5 mW. But the good news is that it might be possible to approach 2 or 3 mW without too much effort using a narrower bore, large can style cathode, and modern HeNe laser power supply.
The very similar design described in the Verder Sluis et. al. paper (see the section: K. L. Vander Sluis et. al. HeNe Laser), had a maximum power on the order of 1 mW under optimal conditions based on their measurement of power using a silicon photodiode. So the wild guesses aren't all that far off. :) (However, it may have been capable of as much as 4 or 5 mW using a modern HR/OC pair.)
### Why Not to use Quartz Windows for a Visible HeNe Laser
(From: George Werner (glwerner@sprynet.com).)
The SciAm article recommends using quartz windows because they have the lowest losses. We thought the same thing back in 1963 when we were trying to build a laser like the one that had been demonstrated by the Bell Labs people a few months earlier. Ken Vander Sluis had built our laser with two of our best quartz Fabry-Perot interferometer plates and was trying for days to make it run, with no luck.
Ken is a spectroscopist and understands how energy levels work, so he thought about it, and reasoned that the 3.391 um transition might be depopulating the upper level so that the visible transition wouldn't lase. For the 3.391 um wavelength, quartz transmits well, but borosilicate and other glasses do not. He got another pair of interferometer plates, made of borosilicate crown glass, and put them over the quartz plates, fastening them in place with masking tape. After realignment he found an increase in gain and before long he got that first sparkle of light, the first HeNe laser in Tennessee!
So the moral of the story is: Don't count on quartz windows giving you the best performance. "But", you may ask, "What about those lasers with no Brewster windows?" I have never measured their reflectance, but my guess is that the mirrors must have a multilayer surface that was designed with two criteria: high reflectance at 632.8 nm and low reflectance at 3.391 um.
Even with glass Brewsters, the 3.391 um effect rears its ugly head in long lasers, those with length of one meter or more. In these the path length in the plasma before encountering a window is long enough that the 3.391 um density has a chance to build up to undesirable levels before meeting a window. It's called "superradiance" and can be suppressed with magnets (preferential Zeeman splitting of the IR lines) and/or by grinding the inner surface of the tube to scatter low-angle reflected light. But, tubing with a roughened interior is not as strong as standard tubing.
(From: Sam.)
Yes, that is exactly how they are designed. With sufficiently high transmittance at 3.391 um and possibly the frosted bore as well, the need for magnets to split the energy levels via the Zeeman effect has also been reduced or eliminated. For example, even the Melles Griot 35 mW HeNe laser (their largest model) does not need magnets even though the tube is almost a meter long.
### Comments on Alignment Procedure in "Light and its Uses"
The second of the two articles on the HeNe laser: "More on the Helium-Neon Laser" provides an alternative procedure for mirror alignment which may be potentially hazardous (though realistically, the risk is probably minimal).
The alignment is performed with the laser powered but presumably not lasing since a 'spoiler glass' - a glass microscope slide - is placed in the optical path. While this probably is fairly reliable with minimal risk for the low gain HeNe laser described in the article, many other lasers - or even a longer HeNe laser - may have high enough gain that the losses introduced by the spoiler would NOT prevent lasing and a beam could appear without warning (once the mirrors are aligned well enough) as the adjustment screws are being tweaked! I would NOT recommend the procedure as described for any laser unless a more reliable method were used of preventing accidental lasing (like the use of a 50 percent neutral density filter) or you were absolutely sure of the maximum possible output power of your laser to be less than a couple of mW. Note that even with a spoiler, there is still a slight chance that a HeNe laser will lase if the glass is nearly perpendicular to the optical axis (due to constructive interference of the reflections from its surfaces). A neutral density filter would totally eliminate even this small possibility.
The description as presented is also somewhat ambiguous (but this is clarified below).
Note that if you don't have 20/20 (corrected) or better vision, this procedure may not be appropriate in any case since for the fine alignment, it's necessary to view the reflection from the mirror at the far end of the laser through its narrow bore - not easy with less than perfect eyes.
I would recommend using one of the other alignment techniques described in "Light and its Uses" or in the chapters of this document on HeNe and Ar/Kr lasers.
Having said all that, I am honored to have George Werner, the inventor of the this alignment technique while at Oak Ridge around 1963, address the safety issues and provide a clearer description of the procedure:
(From: George Werner (glwerner@sprynet.com).)
(The alignment card technique may have been independently invented elsewhere.)
First, the matter of safety. If you are looking through the alignment card at the time the laser starts to oscillate you will see a very bright light, but it won't be the last light you ever see. Have you ever looked at a camera flash bulb when it went off? Have you ever looked at the sun? These sources are too bright for normal viewing so nature gives us a defense for it - - we close our eyes immediately. As for the laser's brightness, the first burst of light, if adjustments are made slowly, is much less than the maximum output. Even this exposure can be avoided, as I will discuss later.
The alignment card I have used most recently has a hole about 2.5 mm in diameter. If you're worried about exposure you can make it smaller but that makes precise seeing more difficult. (In our report by Vander Sluis et al, we used .5 mm) The card stock is preferably heavier than normal filing cards, but they will do. The hole is made by drilling to ensure a round shape, but this leaves paper fibers protruding into the hole, which can be made to lay down by polishing the inner edge of the hole with wax or maybe glue. On the front side carefully rule a horizontal and a vertical black line across the hole. It is important that the intersection of these lines be on the hole, and sometimes I think that is easier to rule the lines first and make the hole afterward. A piece of a red gelatin filter, Wratten #29, is mounted on the back side of the hole. I have stuck it in place with a 1/2 inch circle of black masking tape with a 1/8 inch hole in it. Having an area of black around the hole as viewed from the back makes it easier to find and look through. In the deluxe model of card I use a fluorescent red surface on the front instead of white.
The card is used in this way: Position the card at one end of the laser, viewing through the near reflector, so that you can sight through the card hole and through the capillary to the far end. (To facilitate this it may help to place a strongly illuminated target beyond the end of the laser. The fine print on the back of a credit card is good for this purpose.) Holding the alignment card in this position, observe the crosslines as reflected from the back side of the reflector and adjust the reflector so that the pinhole image lies on the capillary axis. Now the adjustment at the near end is complete (we hope).
Next, take the card to the other end and repeat the operation. Note that at no time up to now has the laser been turned on so your eyes should be perfectly safe. NOW turn the laser on and it will shine with all its brilliance (it says here). :)
If, however, the laser doesn't lase, make another inspection of the adjustments. This is where the red filter is needed. If you try to sight down the capillary while the laser is turned on, all you see is a cloud of blue light if you don't have a red filter. One experimenter reported the red filter was ineffective. I suspect that he wasn't using a Wratten #29. The red cellophane from a box of Valentine candy won't work. It passes too much yellow. With a proper filter you can easily see to the far end of the tube through the luminous plasma. With the laser turned on, look through the card and plan your next adjustment of the mirror but don't make it. Then move your eye away from the pinhole and make the adjustment you planned. If it doesn't lase, you can look through the pinhole and repeat the motion to see what is happening at the far end of the tube. If your system is geometrically correct but still not lasing, you will see a brighter (but not brilliant) disc of light coming into position at the far end as the final adjustment is made. This is what is commonly called the "full moon" effect. If that bright spot is well centered when viewed from either end, then you can be assured that no further mirror tweaking is called for and you can turn your attention to gas pressure, current level and all those other problems.
I mentioned the use of a red fluorescent alignment card. What is the advantage of that? The only useful light reflected from a white card with red filter is the red component of the illuminating light. A fluorescent red card reflects the same red light but it also converts the blue, green and yellow light to red, giving us a brighter image.
I haven't found a laser where it was not possible to see the far end of the tube looking through the card. Maybe the sighting hole was too small (like 1 mm or less) or maybe there was fuzz in the hole, or maybe as I have said before the filter wasn't red enough.
In a very long narrow tube it is sometimes hard to determine straightness because internal reflections of a curved tube can give false images of the end opening. The curvature of the tube focuses the light in one plane, while at the same time in the other plane the strong focusing power of the bore radius is decreased at grazing angles, so that there is a curvature for which the reflected image has no astigmatism. Once I made a little light box to use as a target for this test. In front of a 15w light bulb I placed a wire screen mounted on a motor shaft to turn 6 rpm. I set it so that the target was moving left to right. Then if I looked at it through the capillary and saw an image moving right to left I knew that I was looking at a reflection.
### Visually Checking the He:Ne Ratio to Test for Gas Fill Problems
(From: George Werner (glwerner@sprynet.com).)
When you have confirmed good alignment and the windows are clean, you may wonder if the gas mixture is right. In lasers that have been sealed a long time there is sometimes a noticeable loss of helium by diffusion through the glass and through the Epoxy of soft-seals. A good way to check the He:Ne ratio is to view the discharge spectroscopicly. I used to use a transmission grating (600 lines/mm) for this. In the yellow region you will find two lines close together. These are neon, 585.25 nm, and helium, 587.56 nm. If the mix is right these two lines should appear approximately equal in brightness.
For a sealed tube, the helium lost by diffusion can be restored by putting the laser in an atmosphere of 100% helium (at 1 atm) for a day or two. 24 hours of inward diffusion this way is about equal to the outward diffusion of a year. (See the section: Rejuvenating HeNe Tubes.)
### So You Want to Build a Green HeNe Laser?
Recall that green (543.5 nm) is one of the lowest gain of all the common HeNe lasers. So, getting any sort of green laser to work will be quite a challenge.
I do have a working green HeNe laser using a special one-Brewster HeNe tube with an HR optimized for green and a matching HR mirror. OK, so the output isn't anything to write home about - maybe a µW - but the circulating green photon flux is fairly impressive. However, this setup is just about perfect in every way with an optically contacted fused silica Brewster window and super high reflectivity mirrors for both HRs. See the section: A Green One-Brewster HeNe Laserfor details. But it's amazing that such a short (26.5 cm) one-Brewster tube will lase green at all!
Also see the section: More on Other Color HeNe Lasers.
(From: Steve Roberts.)
The green HeNe lasing line was first observed by D. L. Perry. See: "CW laser oscillation at 5433 Å in neon", D. L. Perry, IEEE Journal of Quantum Electronics, vol. 7, no. 2, Feb 1971, pp. 102.
Summary: CW laser oscillation at 5433 Å has been observed in the He-Ne laser. The transition is from the 3S_{2} to 2p_{10} level and is the 9th in this group of nine allowed transitions to exhibit laser oscillation....
> "Green #1 used a 65 cm long, 4 mm ID tube with a 7:1 fill ratio of He:Ne. Both optics had a 1% transmission at 594.1 (yellow) to kill that line. The current range was 16 to 40 mA (!!).
>
> The 611.8 nm (orange) line was used to align the laser (using red/orange optics). Then the green HR mirror was installed in the beam to align it and then the red/orange optics were removed."
He obtained a power of 50 µWatts with this setup.
(From: Sam.)
Hey, but that's still much greater than the output power of that green one-Brewster HeNe laser and also greater than the output power of my red two-Brewster HeNe laser described in the sections starting with:Sam's DIY External Mirror HeNe Laser - Some Assembly Required!.
### A Home-Built HeNe Laser Requiring No Glassworking?
(From: George Werner (glwerner@sprynet.com).)
Yes, it's possible because I have done it. The trick is to mill or saw a 1/2 inch aluminum plate to hold the window at 56 degrees to the axis of a hole you drill through it to receive the small bore laser tube. A side hole connects with this hole into which is glued a nipple for attachment to a vacuum system. Drill and tap a 6-32 hole somewhere for a screw to attach a wire because this piece is also an electrode. The one I made had a few extra square inches extending below so that I could put it in a beaker of water to dissipate the heat from the electrode. The allowable temperature of the aluminum is limited by the heat tolerance of the Epoxy you use to glue it together. Mine was a DC laser so only one end (the cathode) needed to be this large.
A photo of that part of the tube is shown inCathode-End of Home-Built HeNe Laser Requiring No Glassworking. The aluminum block cathode and negative power supply lead can be seen with the Brewster window glued to its angled surface. The glowing bore of the tube extends toward the upper left corner. For scale, the platform is 3 inch aluminum channel and that's one of my early (white) alignment cards in the lower right.
The anode was similar but without the heat sink and vacuum attachment. Keep the kids away from it and/or make arrangements to insulate the high voltage electrode electrically but not thermally.
(From: Sam.)
Sputtering at the negative electrode would be my other concern. If it is near the Brewster window or internal OC mirror, a metal coating could form quite quickly, rendering the laser useless. I would recommend locating the cathode a few inches away - perhaps it could be a second aluminum block or an aluminum tube attached to the end of a glass side-arm glued into the block described above. The advantage of this geometry is that there is no direct line-of-sight path to the optics and thus sputtered material is much less likely to land there. Putting a few heat sink fins on this should provide adequate cooling if it becomes more than warm to the touch.
Even simpler: Use common pipe fittings at each end, one being a "T" for a side-arm mounted glass extension to which the aluminum cathode is attached.
### How about a 100 METER Long HeNe Laser?
This one is probably for the fantasy department but, hey, perhaps that unused LINAC tunnel you have in your basement left over from the defunct SSC project could be put to good use. :)
(From: George Werner (glwerner@sprynet.com).)
Here is a laser design that I planned 35 years ago but never built. If you want to try it out you are welcome to it.
If one wanted to make a really long laser, one way to keep the 3.391 um radiation suppressed would be to stick a glass (not quartz, remember?) Brewster window in the optical path every 50 to 100 centimeters. Also, if we want to maintain the conditions of a conventional laser, we need to refocus the light rays periodically along the length. So the Brewster thing needs to be a lens rather than just a window. But a lens tilted to 57 degrees would have terrific astigmatism. OK, then have the window start with a reverse astigmatism such that when tilted to 57 degrees the astigmatism vanishes. Or, use a normal lens that is AR coated. If the AR coatings are really good then tilt should be unnecessary. (Note that the standard formulas for reflectivity won't work at an AR coated surface - I don't know if there is a Brewster angle for an AR coated surface.)
The change in focal length from tilt is a relatively simple matter for concave reflectors (cosine for one direction, 1/cosine for the other), but for lenses it is more complex. I did a rough check on focus of a tilted lens at 0, 30, and 60 degrees and it showed that the focal distance (can we still call it focal length?) is the original focal length times the square of the cosine of the tilt angle for focus in the plane of the tilt and times the square root of the cosine of the tilt angle in the orthogonal plane. Then I did some more exact ray measurements on the computer and instead of cos2. I found it was closer to cos2.55. (Close, but not exact). I contemplated computing the focus in the other plane but decided that was too much bother since I don't even know if anyone is going to read this. (Well, read?, yes; build?, hmmm. --- Sam.)
Therefore the lens/window, if it is to have a tilted focal length of 50 cm, should have a conventionally-measured focal length of 220 cm in one plane. and 67 cm the other way. The practical way to get such a lens is to deal with a manufacturer of spectacle lenses, so we have to translate to diopters and round to the nearest 1/8 diopter. Thus we end up with a refractive power of 0.50 diopters in one direction and 1.5 diopters in the other direction yielding tilted focal lengths of 45 cm and 50 cm (close enough). I guess the optometrist would call for "sph. +.50 , cyl +1.00". Make sure your lens maker understands that these curvatures are relative to a flat surface on both sides, or you may find you are given a lens that is strongly concave on one side as in standard spectacles. Perhaps each surface should be described as sph +.25 , cyl +.50. Check with the lens man.
After having one made and checking it out, order as many as you want for your laser. Each section has its own power supply and glass system (with a shared window) and they can be tested and added one section at a time. The completed design as I see it is a multiple confocal system with end mirrors of 100 cm radius and intermediate lens/windows with 50 cm focal lengths every 100 cm. The windows nearest the mirrors are flat. When testing an incomplete assembly the second concave mirror should be 100 cm away from the last lens/window.
In my imaginary design of this laser, each section has a glass ball joint near a window so that each section can be adjusted to be collinear with the rest, but I can also see it running as one huge glued-together contraption. After enough sections are added, it should lase without a terminating mirror, and this suggests that by that time it would have lost coherence. Who'd like to predict how much power it will produce? Who'd like to predict what limits the power?

Alternatives to Constructing an HeNe Laser from Scratch

OK, so you really want to play with an external mirror HeNe laser but don't have access to the resources, a suitable work area, or more likely, the determination to deal with the glassworking, vacuum, gas fill, and other requirements of a totally home-built HeNe tube.
The following sections describe various ways of ending up with a working HeNe laser that don't require quite as much in the way of support equipment and supplies as building one from the ground up. These include morphing a commercial HeNe tube into a home-built HeNe laser, using commercial one and two-Brewster HeNe laser tubes with your own resonator, and even a way of converting a cheap barcode scanner HeNe tube into a precision frequency stabilized laser. While perhaps not quite as rewarding as doing everything from scratch, the likelihood of success, particularly with the latter approaches, is much much greater.
Taking an existing HeNe tube and using it as the foundation for an external mirror laser would eliminate some of the hassle of constructing everything from scratch. Specifically, most glass work would be eliminated and by doing things in stages, the risks are somewhat reduced.
If you don't want to even think about vacuum systems and gas supplies, HeNe (and Ar ion) plasma tubes with Brewster windows for use with an external cavity ARE available from various sources. With one of these in-hand, and a matching conventional power supply (commercial or home-built), you can still experience the joy and frustration of constructing and aligning an external mirror laser head. I've even gotten lasing from a HeNe tube with a damaged OC mirror using an external mirror though I doubt there is another similar tube in the entire Universe so perhaps that isn't quite fair. :)
It then is *just* a matter of fabricating the laser platform and mirror mounts, and obtaining a pair of suitable mirrors. There would be NO excuse for failure!
However, the problem is that since such tubes are a lot less common - and mostly used as replacements in expensive high quality research lasers, their cost is considerable. Figure 600to600 to 600to1,000 or more depending on quality, size, and supplier. Check out the large well known HeNe laser manufacturers. Perhaps, if you can convince them it is for an educational project, they might let you have one that doesn't quite meet their specs for free or at cost.
Perhaps, after successfully constructing a laser head in this manner, you will have the confidence to proceed with a totally home-built design. The continuing saga of my (so far less than entirely successful) experience with this approach follows in the section:Sam's DIY External Mirror HeNe Laser - Some Assembly Required!.
The opposite situation is also a possibility: Build your own HeNe plasma tube but mount it in a used resonator. Depending on your resources, this might be an easier task (though I find that hard to imagine!). External cavity HeNe laser heads with dead tubes seem to turn up much more frequently than the other way around (for obvious reasons) and can often be obtained at attractive prices. In fact, the dead tube one of these contains might be a candidate for regassing!

Sam's Three Part Process for Getting Your Feet Wet in Gas Lasers

Sam's DIY External Mirror HeNe Laser - Some Assembly Required!

If you aren't really into glasswork and vacuum systems, it is still possible to experience much of the challenge and feeling of accomplishment by building a laser using a commercial tube and external resonator.
I acquired an external mirror HeNe tube for this exact purpose. Physically, the body of the tube looks like a Melles Griot internal mirror type (but no manufacturer label). Probably the closest current model would be the 05-LHR-120 HeNe tube used in the 05-LHR-121 laser head which is rated at 2 mW. Additional info can be found in the section:Typical HeNe Tube Specifications.
However, instead of the normal mirror mounts and internal mirrors, it has a pair of Brewster windows. Although such HeNe tubes are manufactured for use in research lasers, I suspect this was a one-of-a-kind for another reason: In Magic Marker on the side is printed: He3, Ne22, 2.8, which I assume refers to the isotope of helium and neon used in the gas fill and the gas fill pressure (2.8 Torr). Ordinary HeNe tubes may use normal He4 and Ne20 so my guess is that this was manufactured for someone's thesis project with a title like: "Determination of How Lasing Spectral Characteristics are Affected by Gas Isotope". The consensus is that isotope differences will have only minimal effect - and this is supported by my measurements. See the section: Performing the Single Pass Gain Test.
Actually, having said that before I know what I was talking about (assuming I do now!), the upper energy state of He3 is slightly closer to that of Ne20 so energy transfer is more efficient and thus gain will be modestly higher for a given tube length. This is particularly critical for "other-color" HeNe lasers where every bit of gain is critical. But apparently, virtually all modern HeNe lasers, regardless of color, are now filled with He3. See the additional comments below.
Tubes with Brewster windows are available from several companies includingMelles Griot andJodon. Sizes from 10 cm to over 100 cm (between the centers of the Brester windows) are available which will operate at the 632.8 nm (red) HeNe wavelength. My funny tube has a length of about 25 cm so it is well within this range. This tube appears to be similar to a Melles Griot 05-LHB-290 Brewster tube except for the strange gas fill. Thus, if manufactured properly (e.g., with the proper Brewster angle and properly aligned windows), it should work!
### Description of the Home-Built Resonator
To make use of this tube, I needed to construct a resonator and mirror mounts and provide mirrors. This is shown in HeNe Laser Tube with Two-Brewster Windows Mounted in Home-Built Resonator (not to scale) and Photo of Home-Built Two-Brewster HeNe Laser.
For the resonator frame, I used some aluminum scrap from an old chart recorder and 9 track tape drive (Like the perverbial cow, I use nearly everything!). Low expansion InVar or something else equally exotic and expensive would be better, but given my machine shop or lack thereof, I would much rather deal with aluminum!
* The baseplate is 13(L) x 2-3/4(W) x 5/16 inches.
* The end-plates are 2-3/4(W) x 3(H) x 5/16 inches.
* There are also a pair of stabilizing rods 13(L) x 1/2 x 3/8 inches
Once drilled, tapped, and screwed together, this assembly is VERY rigid.
The mirror mount assembly consists of three parts: a fine adjustment plate, a coarse adjustment plate, and a small slotted adapter to which the mirror optic itself is attached.
1. On each end is an adjustable mirror plate similar to the design shown in:Adjustable Mirror Mount 2 except that instead of thumbscrews and springs, it uses cap screws (hex wrench adjustment) and split washers, respectively. This is similar to the scheme used with the ALC-60X argon ion laser head. The total adjustment range is only about 1 degree but this should be more than enough once the coarse adjustment is done.
2. The coarse adjustment is similar to the fine adjustment but is smaller and attaches on to it with three smaller cap screws again using lock washers instead of springs.
3. The optics are mounted on a plate with oversize holes to permit some adjustment in X and Y to line up the center of the mirror with the bore of the tube.
The tube itself (henceforth called the 'Tube Under Test' or TUT) is mounted by a couple of aluminum brackets and Plexiglas plates with the anode-end on ceramic insulators. The ballast resistor is also mounted on the frame with a Plexiglas cover to prevent accidental contact with the high voltage terminals. There is even a HV Warning sticker - what a concept! Power is provided via a 4 foot HV coax terminated in a male Alden connector.
Once this was all constructed, I checked that it would power up and then evaluated the TUT for gain. See the section:Performing the Single Pass Gain Test.
### Salvaging Some Mirrors
To get it to actually lase, I of course, need mirrors. My intention is to initially select mirrors that will give me the greatest chance of getting some coherent output - even if it is weak. Ideally, this means high reflectance for the OC to minimize gain requirements and some curvature to ease alignment. In the end, what I selected were mirrors from a certifiably dead-dead Melles Griot 05-LHR-002-246, a 5 inch long .5 to 1 mW internal mirror tube, a type used in HeNe laser based hand-held barcode scanners.
This one in particular must have been dropped since the capillary had broken completely off of its attachment at the anode-end of the tube and was rattling around inside. Given this state of affairs, I would expect the "gods of dead lasers" to understand the need for the sacrifice since I could think of absolutely no way it could ever be made to lase again (but I did provide the appropriate chants and so forth just to be sure!).
After evaluating several options on exactly how to remove the mirrors (retaining various amounts of the rest of the tube), I decided to cut them off at the narrow section of the mirror mount. This would minimize the possibility of damage to the optics while at the same time providing a convenient metal collar to attach to my mirror mount plate. To minimize contamination, rather than using a hacksaw or file, I scored a line with a sharp pair of wire cutters and then snapped them off. Then, I cleaned up the rough edges with a file after stuffing the hole to prevent the entrance of metal particles.
Well, since I pulled those mirrors off the little dead tube, I haven't heard of any global disasters so I guess the "gods of dead lasers" (GODLs) are satisfied with my chants. :) I did break a set of wire cutters trying to score a line (maybe that was my payment to the GODLs).
To mount the mirrors, I drilled a hole in each of my plates so they would retain their position by a press-fit. Then, with all the mirror mount screws tightened down, the plates with the mirrors were attached. To confirm that the mirrors were seated approximately correctly, I used my alignment HeNe laser to check for a return beam down the bore of the TUT. It didn't have to be exact (the coarse and fine adjustments will take care of that), but I wanted to be sure it wasn't really far off. A bead of Epoxy then assured that each mirror would stay in the proper position.
However, now I have 3 unknowns:
1. Mirror alignment - This will be a real !@#$. My frame is about 15 inches long and they are planar mirrors. :( It was enough of a pain in the you-know-what aligning my ALC-60X which is (1) shorter, (2) has a curved OC, and (3) passes HeNe red for alignment. I really don't want to fire up an argon ion laser for this.
2. Absolute single pass gain of funny tube. I really can't measure that as noted previously beyond saying that it looks close. So while I believe it to be positive, unable to confirm or quantify.
3. Reflectance/transmission, quality, and cleanliness of mirrors. With less than 2 percent gain, it doesn't take much to kill lasing.
### Attempting Alignment 1
I already knew that alignment would be quite difficult, especially with planar mirrors. What I really need is a set of mirrors with a radius of curvature about equal to the length of my resonator to form a confocal cavity. this would be much easier to align than a planar-planar configuration. Until then, I am stuck with what I have. I played with alignment for a few hours but without any flashes. So, I decided to measure the transmission of each of the mirrors I had available.
* Transmission of OC from 5 inch HeNe tube: .7 percent.
* Transmission of OC from large-frame Spectra-Physics HeNe laser: .6 percent.
All the HRs tested at less than .1 percent transmission.
I know that I only have 2 percent to play with excluding losses through the Brewsters! So, these mirrors at least should be acceptable as long as the losses through the Brewsters are less than 1.3 percent or so. However, to have the best chance, I can just use an HR from another little tube (already have it so no need for sacrifices as someone else already went through that ritual) to see if I can get it lasing at all, then worry about the OC to get some power out at one end. Or, use Sam's special means of extracting power - a plate inside the cavity at almost the Brewster angle - 2 beams for the price of one! :)
(From: Daniel Ames)
Maybe my BEFIA (Beam Expansion for Interference Alignment Method) might come in handy with this one. (I guess that title sure could use some rewording, as the abbreviation sounds like a "beef processors union". :)
Important note: Be sure to offer the HeNe alignment chant, FIRST!
1. Secure the reference laser (R-Laser).
2. Mark the exact spot of the beam on the (stationary) viewing card with a cross.
3. Add to the beam (past where the TUT will be), your best lens and center so you get the most concentric looking pattern, centered on the cross and secure the lens (with tape).
4. Insert the TUT into the beam and by monitoring the (new) position of the beam's spot and the interference patterns, produced by reflection off the TUT's cavity walls, try to get the spot back to the "center" of the cross. Then fine tune the TUT's alignment to make the interference patterns concentrically on axis with the cross's center.
5. The TUT must be secured (without moving it). I found that Steve Roberts' idea of using tape, preferably the 2" wide packaging tape, works pretty well for this.
6. Now align the mirror that is closest to the R-Laser, so that you get more interference - from the reflected beam from the R-Laser's OC and back through the TUT and lens, when viewed against the cross.
7. Fine tune the first mirror to get the new interference more centered with the cross and the interference rings to look as symmetrical as possible.
8. Now, repeat steps (6) and (7) on the 2nd mirror without moving anything.
NOTE: This can be done with the same color HeNe, but the reflections will be substantially reduced in intensity. So, if using the same color R-Laser, (HeNe) use a bright fluorescent sticker or card for the viewing screen and dim the lights.
This procedure should only take a minute or two of your time, or forever. Your mileage my vary. :)
On your alignment jig, have you thought of any way other than the manual (slip and slide) method for lateral adjustment?
Geometrically speaking, it is much easier to move the TUT for aligning, than the reference laser. It works out to be a much less critical movement. The distance of movement of say 1/100th of a degree times the distance between the two lasers, is much greater than 1/100th of a degree times the length of just the TUT. It makes dialing in the alignment much easier, especially if the distance between the two lasers is more than the absolute minimum.
My (unorthodox) method:
It's reversed from the norm. I put the TUT on the alignment jig, and the reference laser was just positioned and secured at the approximate center of the jig's vertical and horizontal travel.
Although with my (unorthodox) method, the TUT still needs to somehow secured to the Jig.
Either way, what about putting a piece of metal, maybe aluminum, under the TUT for a smoother lateral positioning? Just a thought, maybe you already thought of this. :)
But I'm sure that you have a plan. :)
(From: Sam)
Right... I am quite convinced that alignment of the A-Laser relative to the TUT's bore really isn't a problem at this point.
### Attempting Alignment 2
After a few weeks, off and on, of attempting to obtain output from this laser, I am wondering if I need to go back and seriously attempt to determine whether the tube has a net greater than unity absolute single pass gain.
* I have tried several different sets of HeNe mirrors including a pair of HRs from some unknown model internal mirror HeNe tubes donated to the cause (no sacrifices required), the OC from the 20 inch resonator of an ancient HeNe laboratory laser, and combinations of these with the mirrors from my 5 inch HeNe tube.
I would have expected the reflectivity of the OC from that old laser to be similar to what was required for my funny tube because although its tube was (past tense, no longer intact) much longer, the bore was about twice as wide resulting in lower gain/inch. That OC is also curved which should ease alignment requirements. Unfortunately, I couldn't try the HR because it had been damaged. See the section: A Really Old HeNe Laser for a description of that laser.
* My home-built resonator frame is quite stable - more so than I had at first expected. It is possible to set the mirrors very precisely and they stay put.
* I am quite sure that I am getting the far-mirror (from the A-Laser) aligned well enough that adjustment of the near-mirror should result in lasing if conditions support it. The HR mirrors all seem to have some 'wedge' which complicates the alignment of the near-mirror somewhat (using the reflected beam method) but I don't believe this to be the problem as I've rocked it enough to cover the slight offset that results from the wedge.
However, there have as yet been no confirmed sightings of any flashes regardless of which optics were used, the phase of the moon, or wishful thinking. :(
At this point I am therefore left with 2 of the 3 unknowns: Absolute single pass gain of the funny tube and the curvature, quality, and cleanliness of the mirrors. Or....
I just noticed that there is some possibility that the funny gas fill with the non-standard isotopes of helium and neon might have been used to make this HeNe tube producing a green beam at 543.5 nm. See the section:More on Other Color HeNe Lasers. However, for all my tests, I have used red probe beams and mirrors designed to reflect red at 632.8 nm. Perhaps my problem all along is that I should have gone green!
### Finally, Success (More or Less)!
Drum-roll please! Is the crowd ready?? :)
After a pleasant interlude of getting a HeNe tube with a single Brewster window to work (see the section: A One-Brewster HeNe Laser Tube), I returned to this effort. I suspected that part of the problem was that I hadn't paid enough attention to the cleanliness of the Brewster windows. With the one-Brewster tube, even a single spec of dust or fine coating of who-knows-what could drastically reduce the output power. With two Brewsters, such effects would be much worse.
So, I went back to optics from the large-frame Spectra-Physics laser (and are what are shown in the photo, above). I hoped these would have the best chance of lasing short of a pair of long focal length HRs which I currently don't have. (The OC from the old lab laser might be even better if it has higher reflectivity - I may try that in the future.)
I discovered that by watching the scatter from the Brewster window closest to the alignment laser (A-Laser), it was possible to tweak the mirrors so that the spot caused by the beam from A-Laser and the return from the HR mirror at the other end of the tube could be superimposed. If this was done with the OC's reflection smack in the middle of the A-Laser's output aperture, there would be an increase in intensity and fluctuations in intensity due to mode cycling of the A-Laser and light bouncing back and forth between the A-Laser's OC and the OC of my resonator. At this point, alignment was really very close.
While gently rocking the mirrors I got what were unmistakable flashes for the first time. More cleaning and blowing off of dust and I was finally able to get a few photons of coherent 632.8 nm light coming from the funny tube.
Actually, a grand total of about 19 µW. (That's 19 whole microwatts - not milliwatts or megawatts!) It's a nice TEM00 beam - just not very bright! :)
Part of the problem may be that the inside of the Brewster on the cathode-end of the funny tube seems to have a lot of scatter - about as much as I get from the Brewster window of the one-Brewster tube with perhaps 100 times as much circulating light flux between the Brewster and the OC. How do you clean the inner surface of a Brewster window on a sealed tube? :(
Another and perhaps more significant characteristic is that when first turned on, the output power may be more than 2-1/2 times greater (more than 50 µW!!) and then decays to the lower value over the course of a minute or two. If it is turned off for a minute or two, the behavior will repeat. This could indicate a gas fill problem as I've seen similar behavior with an old Spectra-Physics 084-1 soft-seal HeNe tube. The mechanism would be that discharge current is causing the gases to be redistributed to the detriment of lasing gain or the optical power that can be extracted from the population inversion (sounds impressive at least!). The color of the discharge isn't obviously incorrect but could be a bit more pink than normal, though the spectrum appears normal. However, I may attempt to reactivate the getter in any case but this will have to wait until I get my induction heater working - there is no way to do this easily with my solar heater or by loading the entire laser into the microwave! However, I have tried the RF exciter test for gas fill problems and the results would seem to indicate that there is no detectable contamination.
I do believe at present that my OC reflectivity is marginal and I should be able to get a bit more power out of this tube by locating a mirror with 99.6% or greater reflectivity. As noted, I have tried a couple of HRs (which would certainly satisfy the reflectivity criteria) without even a single pair of coherent photons being ejected from the laser but since they originated from small internal mirror HeNe tubes, their focal lengths may have been too short.
Anyhow, this is success! I don't know how much more I can squeeze out of it regardless of optics but at least the entire effort resulted in a working laser - even if you do need to have someone point out the location of the beam!
I have left the two-Brewster laser as well as the A-Laser (just in case) set up against the back wall of my laser lab bench and turn it on from time-to-time just to be sure I wasn't imagining things. It continues to work at about the same power (or lack thereof) level, generally without requiring any mirror tweaking to peak it, only brushing off the Brewster windows.
Epilogue: Awhile later, I acquired a similar tube on eBay or somewhere which wasn't from some funky research project but also didn't behave much better for similar reasons - scatter on the inside on one of the B-windows. Healthy samples of these same tube are capable of 2 to 3 mW using optimal mirrors. This has subsequently been confirmed with new mirrors and a somewhat shorter cavity. Yes, I cheated and used a proper optical rail with green alignment laser, somewhat shorter cavity length, kinematic mirror mounts, and new/NOW mirrors. With sick tubes and salvaged mirrors, what should one expect? ;-) I don't believe the high quality expensive parts made a significant difference.
### Comments on the Funny Two-Brewster HeNe Tube
I finally got around to asking Steve Roberts if he had any additional info on this thing:
(From Steve Roberts.)
You've got a research tube. And, being as short as it it, probably one designed for a single longitudinal mode. The foggyness on a hene is bad news... Do you get chaotic fluctuations as the mirror is moved slightly or if you put your finger on the tube? If so you have dirt in the path.
I suspect your tube was designed for spectroscopy games, or perhaps to be locked to a iodine or methane cell as a standards laser for metrology. Or maybe somebody was redoing the isotope work to see if anybody missed something.
Your best bet on the isotope thing is to contactSpectra Gases and ask them what isotopes they sell in the hot HeNe mix.
The following excerpts is from: "Laser Fundamentals" by William Silfast, ISBN: 0-521-55617-1:
> "and a single isotope of neon (Ne20) is used to keep the gain bandwidth to a minimum and thereby increase the gain."
>
> "Using a natural mixture of neon will reduce the gain by approximately 10%. Additional modes will then only develop from the Ne22 isotope if the much smaller gain in the frequency range of that isotope exceeds the losses within the laser cavity."
>
> "The shift between Ne20 and Ne22 is approximately 1 GHz, whereas the bandwidth due to doppler broadening is on the order of 1.5 GHz".
From what I can tell, Ne22 has a difference in gain of -9.8% in the mix (best guess on the sign, as the graph in the text is ambiguous. Naturally occurring neon is: 90.8% Ne20, (10 neutrons), .26% Ne21(11 Neutrons), and 8.9% Ne22 (12 neutrons).
Naturally occurring helium is 99.9998% He4 and .00013% He3, so somebody wanted a real shift in the hyperfine spectrum of a HeNe laser, I would suggest asking why on the USENET newsgroupscl.physics.research.
I don't know about the chance of the other color lines lasing on a short tube like that, but I'd get two pieces of Newport BD-1 coated mirror and find out. It's 99.99% reflectivity across the visible spectrum and well into the IR. I doubt you'll see green in less then a 1 meter tube with brewsters but yellow is a strong candidate.
(From: Sam.)
I see that Spectra Gases does list He3 and Ne22 on theirVisible and Infrared Laser Gases Page but you have to call for more info.
As suggested, I posted to the USENET newsgroup sci.physics.research (as well as alt.lasers). Here is the one reply so far:
(From: Excimer (species8672@email.com).)
My good friend Chris Leubner - laser expert extraordinaire - was very interested in your laser:
> "I think you have found a very unique HeNe laser tube. Helium 3 comes from tritium. He3 also has a higher energy state than normal He4. So the laser is quite efficient at operating at an otherwise weak line. It is most likely designed to operate at a wavelength of 1.523 um. This wavelength is used for infrared spectroscopy and fiber analysis. It most likely came from some sort of spectrometer or fiber optic analyzer. Definitely hold on to this laser! It is a very rare find!"
PS: Try and see if it would work with other types of mirrors... You never know...
(From: Sam.)
OK, so now I need a set of mirrors good for 1.523 um.... :)
But now, perhaps the final word:
(From: Lynn Strickland (stricks760@earthlink.net).)
Most HeNe lasers are filled with He3 and an equal mixture of Ne20 and Ne22. This broadens the gain curve and provides a little more power. Some want just Ne20 or just Ne22, usually for frequency references.
The center of the gain curve for Ne20 and Ne22 are (can't remember for sure) about 500 MHz apart. If you want a precise frequency reference, you wouldn't want the mixed neon isotopes because the center frequency could vary anywhere in that 500 MHz range.
As for the He, no one really uses He4 in HeNe lasers any more - only He3.

Sam's Instant External Mirror Laser Using a One-Brewster HeNe Tube

So even the only partially home-built HeNe laser described in the section:Sam's DIY External Mirror HeNe Laser - Some Assembly Required! is still too complex? How about one that can be put together in an hour or so and be made to lase with almost anything better than a shaving mirror? Such a laser can be built easily using a commercial HeNe laser tube with an internal HR mirror and Brewster window in place of the OC mirror. While such tubes are very expensive if purchased new, they are available surplus from various sources at reasonable prices. In fact, a few linearly polarized HeNe tubes (like some Hughes models) may actually be one-Brewster tubes with the OC mirror mount fastened to the end of the tube externally with Epoxy. Thus, if you have one of these, it may be possible to remove the mirror without damaging the rest of the assembly to use just the one-Brewster tube alone.
This should be the experimenters' dream laser combining low cost, ease of use, safety, simplicity, flexibility, and a visible beam while still providing convenient access to the inside of the resonator. With only very modest metal working skills and a hacksaw, file, drill, and tap, a one-Brewster HeNe laser tube and compatible power supply can be turned into a an external mirror (well, one mirror at least - which is really all you probably need in most cases) laser for experimentation with the high photon flux inside the resonator; effects of mirror reflectivity, curvature, and location; or just the thrill of seeing several hundred mW to several WATTs of HeNe laser light bouncing off specs of dust - along with the frustration of knowing that you can't really get at it! :)
The safety aspect in particular of this design makes it an ideal laser for experiments requiring access to the cavity. There are no high voltages near the Brewster window and mirror mount assembly, the tube is fully enclosed in a robust aluminum cylinder, and the output beam power will generally be well below the Class IIIb threshold. Even though there is Class IIIb power inside the cavity, it is in a sense 'virtual' - if anything interrupts that beam, including an unsuspecting eyeball, it simply disappears as lasing stops.
And, unlike most commercial external mirror HeNe lasers which locate the mirrors as close to the ends of the tube as possible, you can mount the mirror for your one-Brewster HeNe tube at almost any distance to provide either easy access to the circulating photons or to just show off with a several hundred or more mW beam visible in the air. For example, with the 60 cm radius of the HR typically found in these one-Brewster HeNe tubes, a planar mirror will work as far away as about 30 cm (~1 foot) from the Brewster window; another 60 cm mirror could in principle be mounted up to 90 cm (~3 feet!) away though adjusting its alignment would be quite a treat. :) In the design described below, we'll be a bit less ambitious, but see the section:Mirror/Optics Test Jig Using One-Brewster HeNe Laser Tube.
### One-Brewster HeNe Laser Parts and Assembly
A drawing of a typical one-Brewster HeNe tube is shown inHeNe Laser Tube with Internal HR and Brewster Window with External OC mounted in its laser head along with the external mirror mount detailed below. This is the CLIMET 9048 laser head which uses the Melles Griot 05-LHB-570 one-Brewster HeNe tube.
I have a limited quantity of Brewster and Window laser tubes and heads (with or without power supplies) available for sale. See the section: Sam's Stuff for Sale or Trade and Items Wanted.
The parts list and mirror mount drawing is provided below:
* 1 - CLIMET 9048 (or equivalent) one-Brewster HeNe laser head.
* 1 - HeNe laser power supply with Alden Connector, 1.5 kV, 6.5 mA.
* 1 - Dielectric (or first surface aluminum in a pinch) mirror (see text).
* 4 - 1/4" x 2" threaded standoffs tapped 6-32, at least 5/8" deep both ends.
* 2 - Aluminum plates 1-7/8" x 1-7/8" x 1/8" (mirror mount, see diagram).
* 1 - Aluminum plate 3/4" x 1-1/2" x 1/8" (mirror retainer, see diagram).
* 16 - #6 flat washers.
* 4 - #6 lock washers.
* 5 - 6-32 x 3/4" screws (any type head for mounting).
* 3 - 6-32 x 3/4" screws with hex or Torx slots (mirror adjusters).
* 2 - 4-40 screws for the mirror retainer (length depends on mirror thickness).
(Not listed is any hardware required to mount the laser head and mirror mount assembly to a baseplate or enclosure.)
The left photo in Sam's External Mirror Laser Using One Brewster HeNe Laser Head shows the complete system with mirror mount and an SP-084-1 OC mirror installed in the Simple Mounting Cell for Salvaged HeNe Laser Tube Mirrors. A Melles Griot 05-LPM-379 power supply brick set for 6.5 mA provides the excitation. The middle photo shows the adjustable mirror mount and support standoffs. This assembly can be easily swapped to another similar one-Brewster HeNe head requiring at most a touch-up of the mirror alignment. For the right photo, an SP-084-1 HR mirror has been installed in place of the OC to maximize the internal circulating power. The scatter of the 500+ mW circulating photons from the random dust particles (in a relatively dust-free office environment) is quite visible.
Note that this HeNe tube operates reliably from a small HeNe laser power supply like the Melles Griot 05-LPM-379 because it has a wide bore and thus a low operating voltage (1,470 V from the power supply at 6.5 mA assuming a 68K ballast resistance). However, the 05-LPM-379 would appear to be a bit marginal for starting (8 kV instead of the 10 kV listed for the tube) and one recommendeded Melles Griot power supply is actually the 05-LPM-939 which has a somewhat higher maximum starting (and operating) voltage. While these tubes will work on either supply, starting is very quick with an 05-LPM-939 even for a tube that might (on a bad day) take a minute or more to start using an 05-LPM-379.
Mirror Mount Plates for One-Brewster HeNe Laserhas the mechanical details for compatibility with the CLIMET 9084. The only critical dimensions are the locations of the 4 corner holes and center hole. Everything else can be modified for use with your particular mirror(s). If you don't have some aluminum scrap, even Plexiglas or other rigid plastic can be used in a pinch. The hardware should be readily available from any electronics distributor or your junk box. :). The fixed aluminum plate and 4th standoff can be eliminated with a slight reduction in stability as shown in Anode-End One-Brewster HeNe Laser Tube Mounted in Test Fixture. (This also happens to be one of the less common tubes with the Brewster window connected to the high voltage.)
If your junkbox is bare and you don't want to 'invest' in standoffs, 6-32 threaded rods or long screws and some extra nuts and washers could be substituted instead with slightly lower rigidity and ease of set up, but the standoffs are really much better. In any case, don't be tempted to use too thin a material for the mirror mount plate (not less than 1/8" for aluminum) as the adjusting screws may warp it enough to really confuse things. :(One-Brewster HeNe Laser Head with Very Simple Mirror Mount shows such a setup with a piece of a barcode scanner spinner mirror for the OC (though it actually is more of an HR in terms of reflectivity). This arrangement isn't fancy or elegant but is quite stable and relatively easy to align.
Here is the parts list for the simplified setup:
* 1 - CLIMET 9048 (or equivalent) one-Brewster HeNe laser head.
* 1 - HeNe laser power supply with Alden Connector, 1.5 kV, 6.5 mA.
* 1 - Dielectric barcode scanner spinner mirror chip glued to 1/2" diameter washer.
* 3 - 6-32 x 2" threaded machine screws.
* 9 - 6-32 nuts.
* 1 - Aluminum plate 2 x 2 x 1/16" (or thicker).
* 2 - 4-40 x 1/4" screws for the mirror retainer.
Or go a bit less basic as shown in Enhanced Simple Mirror Mount for One-Brewster HeNe Laser Head, built by Dave (Ws407c@aol.com) for one of these (purchased from me). He added springs and wing nuts which allow for easy adjustment (possibly too easy though as bumping one will mess it up!). Actually, the photo makes the mirror mount look much spiffier than it does in person. :)
Almost any planar or high Radius of Curvature (RoC=r, more than about 12 inches) high reflectivity (R, more than about 94 to 96 percent at 632.8 nm) good quality first surface mirror will result in lasing action if mounted next to the Brewster window. However, the range of positions beyond this for the resonator to be stable will depend on the actual RoC as noted above. Here are the rules:
* The resonator is stable if L is less than the smaller of (60 cm,r).
* The resonator is stable if L is between the larger of (60 cm,r) and (60 cm + r).
Where:
* L = the distance from the internal HR mirror to the external mirror.
* r = the RoC of the external mirror.
* 60 cm = the RoC of the internal HR mirror.
In practice, lasing may not continue quite to the limits but should come close.
While OC mirrors from 5 or 6 inch barcode scanner HeNe tubes have adequate reflectivity, their RoC may be so short (typically 26 cm for the OC) that no lasing is possible until the mirror is more than 60 cm from the internal HR (more than a foot from the Brewster window). And, some longer HeNe tubes like the Siemens LGR-7641S use the same 26 cm radii for the OC mirror so tube length alone is no guarantee of a suitable OC curvature.
Some examples of the approximate range of positions (*) where an external mirror (e.g., OC) of a particular RoC should work with the internal HR having an RoC of 60 cm:
Distance to HR: 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 cm
| | | | | | | | | | | | | | |
26 cm OC: ( =\ *********
45 cm OC: ( =******* *****************
60 cm OC: ( =*************************************
80 cm OC: ( =************* ***********************
Planar OC: ( =*************
Dielectric mirrors are much better than aluminized mirrors but the latter may work in a pinch (though not that well, and some just don't have the required reflectivity even though they may look identical). I've gotten several mirrors from HeNe laser based barcode scanners and an old HeNe laser based laser printer to work with these HeNe tubes. A high quality dielectric mirror with very high reflectivity (e.g., greater than 99.9 percent such as a HeNe laser HR) and low losses should result in a great deal of circulating power inside the resonator - possibly up to a WATT or more and a very visible beam in there unless you are in a clean-room, but only a weak output beam. The OC from a typical medium length HeNe tube will result in a more modest 300 or 400 mW inside the resonator but a useful output beam of 1.5 to 5 mW. A mirror from that laser printer produced 750 mW inside the cavity with a 0.9 mW output. And those barcode scanner spinner mirror chips result in very high circulating power with only a few hundred mW of output. As a matter of fact, it is likely that these non-laser dielectric mirrors are actually probably better quality than the laser-quality mirrors of the 1970s.
Even with just a bare tube or laser head without the external mirror mount, it is quite easy to test a mirror by holding it about 2 to 3 inches away from the Brewster window positioned so that the reflection of the light of the discharge from the bore is centered around the Brewster mount. Then, rocking the mirror about this position should yield flashes quite quickly if the mirror has adequate reflectivity and is of high enough quality. Thus the lasing ability of a newly acquired one-Brewster tube or head can be easily determined without constructing the mirror mount as long as a suitable mirror is available. Or, evaluating a newly acquired mirror using a known good one-Brewster tube.
These HeNe tubes usually can produce a beam which is TEM00 or multimode depending on the mirror and a stop inserted inside the cavity. (This should happen on a red HeNe laser when the ratio of the aperture diameter to mode radius is about 3.5:1.) The higher order mode structure is quite interesting (not just a rectangular array). Higher quality mirrors will result in a more well defined mode structure. There is enough gain that additional Brewster angle optics (even a cheap microscope slide) can be introduced inside the resonator to act as an etalon, and possibly optics that are just AR coated as well.
Note that there should generally be no need to touch the alignment of the internal mirror to get these to lase unless someone before you had mucked with it. I don't particularly recommend attempting this alignment though since unless the output beam is obviously non-circular (oval or cut off) even with the external mirror aligned for maximum output power, any benefit will be minimal. However, where there is a locking collar present, some careful tweaking (basically walking this mirror and your external mirror) is relatively low risk and may result in some additional output power by centering the intracavity beam in the bore. Only attempt this while the tube is lasing (unless you enjoy going through the entire alignment procedure using an external alignment laser) and take care with the high voltage! Where there is no locking collar, a standard Melles Griot locking collar from a dead HeNe laser tube can be installed.
However, with a mirror and lens for the external mirror, it can be even easier to get these things lasing with basically no alignment. The mirror and lens are rather special though. See the section:Cat's Eye Mirror for Hassle-Free Alignment. I need to scrounge something along these lines. :)
### Initial Tests and Mirror Evaluation
The one-Brewster HeNe tube I have is part of a CLIMET 9048 laser head, original application unknown (but likely particle counting or something like that). The actual HeNe tube is a Melles Griot 05-LHB-570 rated at 4 mW output with a matched OC mirror. (Since there are previously owned tubes, getting that much output power may be optimistic but the ones I've tried will all do at least 2 mW with sub-optimal mirrors, see below.) In order to test it, I constructed a mirror mount similar to the one described in the previous section. This enabled various mirrors to be easily installed and aligned and provided access to the inside of the laser cavity. Small mirrors could be 'quick checked' for lasing ability by positioning them inside the cavity (in front of any mirror that is already in place) and then attached to permit fine alignment.
First, I fired the unit up on a Melles Griot 05-LPM-379 power supply brick to confirm that the tube was intact and had the correct discharge color. It did, though I figured this power supply might be a bit marginal. From the bore diameter of at least 1.4 mm, it would appear to be a tube which would tend to produce a beam with multiple transverse modes and would require a higher current than typical for narrow bore TEM00 HeNe tubes for maximum power output. During the subsequent tests, I used an adjustable HeNe laser power supply (the one described in the section: Aerotech Model PS2B HeNe Laser Power Supply (AT-PS2B) with a Variac (and its internal regulator disabled). A tube current of about 7.5 mA resulted in maximum power output. Note, however, that Melles Griot actually recommends 6.5 mA for the tube current and it turns out that the 05-LPM-379 power supply brick will provide this with no problem.) I don't know how life expectancy will be affected by runnnig at the higher current and the ballast resistor supplied with the CLIMET 9048 laser head may overheat after awhile.
The OC-end of the laser head has a flange with conveniently located holes to attach the external optics. I used 4, 2-1/4" x 1/4 threaded spacers to mount a pair of 2"x2"x1/8" plates, the second of which is adjustable via using a hex wrench via cap-head screws and split washers used as springs. My mirror mount. :) See the HeNe Laser Tube with Internal HR and Single Brewster Window and External OC.
Based on the geometry (assuming that the HR mirror has a radius of curvature of 60 cm as I had been told and later verified), a stable resonator should result for an external mirror at a 30 cm distance from the HR as long as its radius is between +30 cm and planar (concave) or -30 cm and planar (convex). This means that except for some short radius barcode scanner HeNe tube mirrors, almost anything else with enough reflectivity at 632.8 nm should work. At this point, I didn't really know the value of the required reflectivity to achieve threshold.
I had several possible mirrors to try both from deceased internal mirror HeNe tubes as well as from a couple of external mirror HeNe lasers. Initially, for rough alignment, I used another HeNe laser (the A-Laser) firing down the bore of the 9048 without the OC in place. The returned a strong nicely focused reflection which (indicating a curved/concave OC) and centered in the A-Laser's output aperture. Then, without disturbing anything, the candidate OC-mirror was installed and the mirror mount adjusted to center its reflection in the A-Laser's output aperture.
I first tried the OC from a dismembered tiny barcode scanner HeNe tube - a Melles Griot 05-LHR-002-246. No amount of fiddling resulted in any output beam. Nor did the use of its companion HR. (Using an HR mirror in place of the normal OC to test a laser results in the lowest lasing threshold since it maximizes round trip gain. Thus, it should be easiest to get going where losses are unknown. For a high power laser, this can be risky since the oscillations in the resonator could build up to a sufficient level to actually damage the optics. However, for a low power (at least) HeNe laser, such effects are unlikely.) I assume that these mirrors were unsuitable either because the reflectance was too low (for the OC) and/or they were curved with a radius of curvature that was too small (almost certainly the latter). (Later I did achieve lasing with that same HR. I don't really know what caused it to fail the first time.)
Next, I tried the HR mirror from an unidentified (but probably Hughes) internal mirror HeNe tube, using the same alignment technique. And, almost as soon as I touched the adjustment screws to center the its reflection, a beam appeared! I almost missed it shining back into the A-Laser but then noticed the really bright scatter off of the Brewster window. With the a bit of tweaking and HR mirror adjusted for maximum output, the beam was weak (maybe 10 µW, just the minimal transmission through the HR that is normally considered waste!) but this was success! While not exactly strong, it was stable. Of course between the OC and the Brewster window, there was probably several hundred mW bouncing back and forth as evidenced by the dancing illuminated specs of dust. :)
As expected, the laser produced a beam with multiple transverse modes - perhaps TEM44 though somewhat jumbled (not a nice rectangular or hexagonal array).
Well, a 10 µW beam isn't anything to write home about (unless it is the first one you ever got from a semi-home-built laser of this type!), so as much as I didn't want to disassemble a working setup, I decided to try the one remaining good mirror from the small external mirror HeNe lab laser described in the section: A Really Old HeNe Laser (the other mirror was damaged due to a cleaning attempt since they were soft-coated as I found out the hard way). I really didn't know whether it was the OC or HR.
With the wide bore of the 9048's tube, I discovered that if a mirror candidate was going to work, I could pretty much dispense with the rough alignment. Just holding the OC in my hand next to the mirror plate and rocking it would result in flashes! And, for this mirror, the beam was definitely much stronger than the previous attempt so I assume it was the OC of the lab laser. When mounted as shown in the diagram, the result was a TEM77 (or thereabouts - again not like would be shown in a textbook!) beam of about 1 mW output power.
Next, I tried the OC from a large frame Spectra-Physics HeNe laser, possibly an SP-125 (I don't really know for sure where it came from). This proved to be the best so far. A similar or perhaps even more complex and wonderful mode structure but with over 2 mW of output power.
The acquisition of this head represented a pleasant interlude to my otherwise frustrating experience (so far at least) with the funny two-Brewster tube I had been attempting to get to lase. (See the section:Sam's DIY External Mirror HeNe Laser - Some Assembly Required!. Knowing that the CLIMET 9048 had been a commercial product and thus known to work in some application gave me confidence that only minimal fiddling would be needed to get it to produce a beam. And, as it turned out, it was even easier than I had expected.
Watching the beam between the OC and Brewster window is entertaining in itself knowing that more than 350 mW is circulating there but not being able to tap it! (2.25 mW out for a mirror with 99.4% reflectivity.) The amount of power is evident from the visibility of light scattered from the specs of dust as noted above. Of course, moving anything (including a finger - since the power can't be extracted, you won't feel anything - trust me!) in to block any portion of the circulating beam results in a reduction in the output power and the number of transverse modes present (reducing the diameter of the beam).
As an experiment, I introduced a microscope slide as a second Brewster window between the OC and the tube's Brewster window. This also resulted in a significant reduction in output power and the number of transverse modes but not to the point of killing lasing entirely (at least as long as the slide was immaculate and arranged close to the optimal angle). (When doing this, some very slight mirror adjustment will be needed if the OC is curved since the refraction inside the second Brewster shifts the location of the beam slightly).
I later dug up an etalon from a large frame ion laser and tried that - I could get reasonably strong lasing when held very carefully with its optical axis nearly parallel to the tube's axis. I don't currently have a suitable mount for the etalon so further experiments with this will have to wait.
And, even a single spec of dust may reduce power by 10 percent or more. Just sitting in my not-so-sterile basement lab resulted in a steady decrease in power over the course of a few minutes (after cleaning) as dust collected on the optics. In fact, I suspect that a proper cleaning of both the Brewster window and OC with spectroscopic grade methanol in a dust free environment would result in substantially more output power. I was just using using 90% isopropyl alcohol and cotton swabs! (With enough work, the scatter off of the outer surface can be made less intense than the scatter from the supposedly pristine inner surface inside the tube of the Brewster window.) I have not done any cleaning of the OCs themselves beyond blowing off dust with an air-bulb since I don't have the proper cleaning supplies and they are a lot less robust than the Brewster window.
I then positioned the OC from a poor old deceased Spectra-Physics 084-1 HeNe laser tube (it didn't survive baking in the microwave oven! :) See the section: An Older HeNe Laser Tube) in my hand between the Brewster window and OC mounting plate to see if it would work - and got flashes immediately. So I installed it. With full alignment and optimization requiring somewhat less than 1 minute, I'm getting spoiled by the eagerness of this setup to lase! This mirror performed at least as well as the large-frame OC peaking at more than 3.0 mW with a well dusted Brewster window:
* Output beam power after 10 minute warmup with clean optics: 3.2 mW.
* Power lost from Brewster window reflections: .06 mW x 2 (up and down) = .12 mW.
* Circulating power: 300+ mW (based on known OC mirror reflectivity of 1%).
The OC from a deceased 20 mW internal mirror HeNe tube produced an output beam of about the same power level despite its reflectivity being only 97.7 percent.
As noted, testing and aligning these mirrors is very easy with this wide bore HeNe tube. The 'holding the mirror in your hand and rocking it trick' doesn't work nearly as well with a narrow bore 05-LHB-270 one-Brewster HeNe tube. That tube has a bore that is less than 1 mm and produces a TEM00 beam using the same SP-084-1 OC but mirror alignment is definitely more challenging!
And a note about cleaning the Brewster windows: Many *years* later, I found that common kitchen grade paper towels - even the generic variety - can act as excellent lint-free wipes. A single swipe of a piece of new dry towel will often result in achieving that objective of the scatter on the outside of the window being lower than inside, though a few swipes may be needed for stubborn deposits. And a drop of methanol or isopropyl alcohol or acetone may be required in extreme cases. Just take care with soft-seal B-windows as it may soften the adhesive. (Most modern Brewster windows are either frit-sealed or optically contacted so this should not be an issue.)
### Lasing Using Non-Laser Mirrors
A few weeks later, on a hunch, I decided to try a couple of other mirrors that were never intended to be used inside a laser resonator. Someone had sent me several cartons of supermarket checkout barcode scanners and parts (most HeNe laser based) which naturally include many mirrors, all first surface. Some dielectric coated but most are just aluminized. I couldn't resist trying a couple of the smaller mirrors from an IBM 4687 just to see what would happen using the "hold the mirror approximately in front of the HeNe tube" approach. :) The IBM 4687 is the full size (often with electronic scale) scanner used at many supermarkets (at least until they are replaced with something more modern).
* Dielectric mirror: - This is used in the beam return path and is thus quite large compared to what is needed here - approximately 1.5" x 2" - so you could get many laser mirrors from one of these with the use of a glass cutter! It is dielectric coated for the 632.8 nm wavelength and appears to be of very high quality. First, I tested it to determine approximate reflectivity using another HeNe laser. Result: At least 99.3 percent. After removing that wonderful SP-084-1 OC and setting it aside, it took all of 5 seconds, to obtain a nice beam and dancing dust particles inside the resonator. Its intensity appeared to be stronger than that using the OC from the large-frame HeNe laser or SP084 tube - possibly as much as 1 W by eyeball. The output beam was somewhat weak - perhaps .2 mW. At some point, I will determine these more precisely. So, this mirror would make a nice HR for experiments requiring a high photon flux inside the resonator.
* Aluminized mirror: - This is the 'first turn mirror' - used to fold the beam path from the scanner's HeNe laser. Being aluminized, it really has no business working as a resonator mirror at all in a low gain HeNe laser - but it did, with almost the same ease. However, the performance was not nearly as good as with the dielectric mirrors. The internal circulating power might have peaked at (just guessing) 10 or 20 mW (compared to the several hundred mW for the SP084 and possibly much more for the 4687 dielectric mirror, above. (Of course, with the aluminized coating, there was no output beam at all.) Just the fact that it worked testifies to eagerness with which this tube likes to lase!
Both these mirrors are, of course, planar. They are also quite old but in pristine condition. I just used some rubbing (isopropyl) alcohol for cleaning.
I then tried a dielectric mirror ripped from a little somewhat bedraggled multifaceted motorized scanner, origin and purpose unknown. I mounted this one properly so I could actually tweak the alignment and expect it to stay put. It also had very high reflectivity, similar to the dielectric barcode scanner mirror:
* Output beam power after 10 minute warmup with not particularly clean optics: .5 mW.
* Power lost from Brewster window reflections: .1 mW x 2 (up and down) = .2 mW.
* Circulating power: 500+ mW (based on Brewster reflection power relative to SP084-1 OC, above).
In fact, this mirror would work even when mounted with its back (glass) side facing the HeNe tube! Not as well - output of about .15 mW but that it did anything is still kind of amazing!
Next, I installed the dielectric turning mirror from an old large HeNe laser-based laser printer, manufacturer and model unknown:
* Output beam power after 10 minute warmup with relatively clean optics: .9 mW.
* Power lost from Brewster window reflections: .15 mW x 2 (up and down) = .3 mW.
* Circulating power: 750+ mW (based on Brewster reflection power relative to SP084-1 OC, above).
This printer yielded a number of mirrors that with adequate reflectivity but some of the others had a frosted back surface so they wouldn't make very good OCs but would be fine for HRs and inside-the-cavity experiments.
Some time later, I acquired a cosmetic reject HR mirror for a 1,000 W (!!) copper vapor laser made by Coherent for Lawrence Livermore National Laboratory (sent to me courtesy of Sterling Resale Optics). This mirror was just a bit of overkill in the diameter department: 76 mm (3 inches)! It must have cost the U.S. Government more than you would care to imagine. :) While designed for the wavelength range 511 to 578 nm at 45 degree incidence (better than 99.996 percent, 1/20 wave surface finish), since the reflectivity wavelength function shifts up about 50 nm when going to 0 degree incidence, I expected it to work well at 632.8 nm - and the results were most impressive. Although it was somewhat difficult to tell by just holding the mirror in my hand (heck, I don't have a mount for a 3 inch diameter mirror!), the circulating power appeared to be higher than anything tested previously with only a small fraction of a mW of output. I was unable to measure its reflectivity. My 2 mW HeNe laser's beam could barely be detected visually (on a piece of paper) after passing though the mirror and didn't register on my laser power meter. It's reflectivity is certainly better than 99.95 percent.
I then remembered that I had a nice new Nd:YAG 45 degree HR mirror someone else had sent me and tried this, also with great success. Its reflectivity is about 99.4 percent for 632.8 nm at 0 degree incidence - more appropriate for an OC, and produced 1 to 2 mW of output power (not measured).
Later, I did build a universal mount of sorts for the mongo mirror so I could stabilize the beam. I didn't measure either the intra-cavity or output power but they were as high and as low, respectively, as I've seen with this one Brewster head. The beam, all 10 or 20 µW of it, was multimode as expected, but a sort of doughnut in this case.
Perhaps, I will have to try a shaving mirror next. :) However, this probably won't work. Some other first surface aluminized mirrors (from an Orion 300 barcode scanner) were just on the hairy edge of the lasing threshold resulting in a very weak beam even when optimally aligned. In all fairness to the physics, an HeNe tube of this size would have a single pass gain of about 2 to 3 percent and thus a round trip gain of about 4 to 6 percent (based on my measurements of the single pass gain of a two-Brewster HeNe tube of slightly shorter length. See the sections starting with:The Single Pass Gain Test). With a high quality HR and Brewster window (to be expected on a tube of this type), those would result in minimal losses so nearly the entire 4 to 6 percent would be available to squander on the external mirror!
### Demonstration One-Brewster HeNe Laser
I acquired a 3 mW HeNe laser that was built into a wonderful Plexiglas box with an output fiber-coupler. This was the aiming laser for some sort of big dye or YAG laser. Since 3 mW HeNe lasers are somewhat boring, even with exposed innards, I decided to replace the tube with one of the bare 05-LHB-570s and the fiber-coupler with an adjustable OC mirror. The result is shown in Demonstration One-Brewster HeNe Laser. The adjustable OC mirror mount is just the platter stack hold-down plate from a defunct harddrive seated on an O-ring with 4 screws. The OC mirror itself, installed in one of my standard mirror cells, is from an SP-084 HeNe laser tube. (I saved the fiber-coupler and fiber for future use - it has the standard hole pattern for mounting on most Melles Griot cylindrical laser heads.) Although not perfectly sealed, the Plexiglas cover provides enough protection so the Brewster window doesn't seem to require cleaning even after months of sitting on a shelf in my dusty basement, err, laser lab. :)
### A Green One-Brewster HeNe Laser
A few months after constructing my one-Brewster HeNe tube test fixture (see the section: HeNe Laser Tube Test Fixture), I was given an 05-LGB-580, a tube identical to the very high quality 05-LHB-580 but with an HR mirror optimized for green (543.5 nm). Popping this tube into the test fixture along with a matching green external HR mirror, it took only about 5 minutes and there were piles of green photons bouncing back and forth between the mirrors! However, having previously gotten a HeNe tube with an obliterated mirror coating to lase (see the section: External Mirror Laser Using HeNe Tube with Missing Mirror Coating), I figured I could even make a carrot lase (orange!), so this green tube really wasn't much of a challenge at all!
The setup is shown in Hughes Style One-Brewster HeNe Laser Tube Mounted in Test Fixture and a photo of a few green photons in Melles Griot 05-LGB-580 Green (543.5 nm) One-Brewster HeNe Laser Tube Lasing in Test Fixture. All the illumination for the photo is from the HeNe bore light and green spots on the B-window, mirror, and wood base. The intra-cavity beam is clearly visible as well as scatter from some hapless dust particles from what may be order of 1 W of circulating power. It has been suggested that the relatively intense reflections off the Brewster window are the result of stress birefringence in the fused silica affecting the polarization through it, but it's not clear how that could arise in the optically contacted seal without it popping apart. And this tube is now (in 2012) at least 12 years old.
To align the mirror, I first set the mirror adjustment screws so the mount was just snug. Then, while gradually tightening the Y adjustment screw, I rocked the mount in X by (pressing and releasing the plate near the X adjustment screw) until there were flashes of green light reflecting off the Brewster window, and then tightened the X adjustment screw to obtain a stable beam. Fine tuning of X and Y peaked circulating power by maximizing the size of the beam scatter on the Brewster window's surface (and thus the number of transverse modes).
Note that since this tube has a glass Brewster stem (the part that holds the Brewster window), it isn't possible (or at least easy) to view the reflection of the bore light back from the mirror (the glow from inside the tube is too bright.) One option is to put a shroud over all but the central area to block this light. However, an alternative way to align the mirror is to view the reflection of the bore light from the mirror off of the Brewster window (from the direction shown in the diagram for "Reflections from Brewster Window"). When this lines up with the reflection of the center of the mirror itself, alignment should be close enough for lasing - you will see flashes. Then, fine tune. CAUTION: For a low power laser like this, viewing the reflection is safe even if it is lasing at full power as what comes off the Brewster window is much less than a mW. However, don't even think about looking at any such reflection for higher power lasers!
The biggest unknown with low gain lasers like this is the cleanliness of the Brewster window(s). One can fiddle with the mirrors all day and not get a single coherent photon if they are even they aren't nearly perfectly clean.
Since both mirrors are very high quality HRs, not much comes out the ends (perhaps a µW or so) but the 4 reflections off the Brewster must total 0.1 mW. This thing came right up with difficulty (or lack thereof) of alignment and mode structure similar to the red one-Brewster tubes but lases green! There is probably several hundre mW, perhaps more than a 1 watt of circulating power based on the brightness of the green photons bouncing back and forth in there. It's nice and stable except that dust just loves to collect on the Brewster windows. Now, what can I do with high green photon flux?
I tried inserting a microscope slide at the Brewster angle as well as nearly perpendicular but all variations killed lasing entirely - not surprising given the gain (or lack thereof) for the green line. And, as confirmation of how low the gain really is, while I can leave a red one-Brewster laser out for a week and have it come right up with nearly full power (at least by eyeball), I usually have to dust off the the Brewster window on this green one to get anything after only a few minutes (or less depending on conditions in my 'lab'). But then I'm still amazed that such a short tube can do green at all! :)
I wonder what the reflectance of a OC would need to be for optimum output (rather than maximum intra-cavity flux)? I've obtained the mirrors from a physically broken 05-LGP-170, a large green internal mirror HeNe tube. (Don't ask but not mine, courtesy of "Dr. Destroyer of Lasers"!) These should make for some interesting experiments. :) The OC probably won't be optimal, having originated from a 16 inch long tube. But since the 05-LGP-170 was a polarized tube, it did have a Brewster plate inside so that at least will be similar in terms of losses. Hopefully, the OC will still have a high enough reflectivity to lase. If it does, almost any output beam would be stronger than what I have now!
But, so far, it doesn't look too promising. I can barely get flashes from the salvaged HR and only with a super clean Brewster window - after 30 seconds to a minute of just sitting, enough dust (or something) collects on its surface to kill lasing totally. And, I can't get anything from the OC. Now, I haven't yet mounted them solidly - I'm just holding the mirrors (in their mounts) in my hand so this hasn't been exactly what you'd call a highly controlled experiment. However, with the high gain (relatively speaking) red one-Brewster tubes, it would be more than adequate to test out a candidate mirror. And, I was able to evaluate the matching green HR that came with the one-Brewster tube without difficulty in this manner. So, it must be a super high quality high reflector even compared to what goes inside green internal mirror HeNe tubes. Assuming a circulating power of over 100 mW and an output of 1 µW, its reflectivity must be greater than 99.999%! Since the gain for green is only a small fraction of the gain for red - much less than 1/10th its value, the reflectivity of the mirrors is super critical, even more so with the not absolutely sterile Brewster window inside the cavity. That last decimal point of reflectivity is significant as there just isn't much headroom and even a very small difference between the two HR mirrors can determine whether any lasing occurs at all.
There is a very slight possibility that the salvaged 05-LGP-170 mirrors are damaged (say from running with reverse polarity) or defective ("Oops, Joe, you know that batch of dud green tubes, we installed the wrong mirrors!") as they did come from a tube that didn't lase and may have been a manufacturing reject to begin with. I could understand the OC not having high enough reflectivity since it was supposed to be for a much longer bore tube but I'm rather surprised that the HR is causing problems. The next step - to mount the HR and see if I can get sustained lasing without an automatic Brewster window wiper - is thus far proving to be very frustrating and so far my 'by hand' approach isn't working - there is no way to know if the Brewster window is clean enough for lasing without the mirrors being aligned and lasing. So, lack of flashes could be bad alignment or a dirty window - a "catch-22" situation.
Even after setting up a red HeNe alignment laser, I have been unable to get the 05-LGP-170 HR (or even my super LLNL mirror) to do anything. With this rig, I can pop in the matching HR and get green flashes consistently but not at all for the other mirrors. In fact, I can't get any flashes from the 05-LGP-170 HR at all at this point - clean Brewster or not. Apparently, the mirror must have collected a film of crud or dust or something just sitting around and in a bag or from when it was out for testing. It certainly looks pristine but won't cooperate! :)
I have subsequently tested the 05-LGP-170 mirrors for reflectivity of the green and yellow HeNe lines (using working HeNe lasers to provide the probe beams). For green, they appear to be quite good, at least to the extent that they reflect the green wavelength. Both reflect virtually 100 percent of green light - passing too little green to register on my laser power meter. For the HR, it is just barely possible to detect photons leaking out by eye. But I guess this is still inferior to the HR mirror which works with the green one-Brewster tube. However, the salvaged HR passes the yellow wavelength almost as though the mirror isn't there (less than 25 percent reflectivity) while the OC's reflectivity for yellow is about 98 percent. Either is low enough to kill the lasing on the yellow (and any other visible) HeNe lines entirely - which is surely the intent. Unfortunately, the HR inside the one-Brewster tube also reflects less than 99% of yellow so there will be no hope of getting it to lase yellow or any other non-green colors.
### Sam's Tunable HeNe Laser (Hopefully)
This is another works-in-progress since I haven't actually detected anything but 632.8 nm red - yet. Encouraged by confirmation that at least some versions of the Melles Griot 05-LHB-570 One-Brewster HeNe tube incorporate an HR mirror that has a reflectivity of better than 99.9 percent from 590 to 680 nm, I salvaged the wavelength tuning assembly - a Brewster prism and mirror mount - from my discombobulated Carson laser (see the section:The Really Strange Carson Dual Tube Ion Laser. Normally, this is used at the HR-end of the laser but I don't have that option with a One-Brewster HeNe tube so it will be at the OC-end instead (though I will using mirrors with high reflectivity for initial tests at least). One disadvantage of this arrangement, however, is that any output beam will exit at a steep angle (around 50 degrees) and this will change slightly as the tuning prism assembly is adjusted to select wavelength.
I constructed a bracket using my standard 1 inch hole spacing so it could be attached to the optics mount of any of my One-Brewster HeNe lasers. The existing mirror mount allows for movement side-to-side (yaw or X) using its X adjustment screw while the Brewster prism assembly can be moved up-and-down (pitch or Y) on its pivots or by using the Y mirror adjustment screw.
So far, this contraption lases happily at the usual (now quite boring) 632.8 nm red wavelength using both one of my barcode scanner mirror 'chips' and the HR mirror from a Spectra-Physics 084-1 HeNe tube. The first of these isn't the greatest quality and the spectral reflectivity curve of the 084-1 HR isn't known. I hope to dig up a proper broadband HR, perhaps from a diseased Hughes style One-Brewster HeNe tubes.
Unfortunately, the losses from passing through 3 optical surfaces (the tube's Brewster window and the two sides of the Brewster prism) take their toll and cleanliness becomes even more important than before. And, the surfaces collect a noticeable power reducing coating in my not so pristine lab (or lack thereof) conditions quite quickly. However, it still seems to produce a circulating and output power which are at least of the same order of magnitude as without the tuning prism. :)
With the Brewster prism itself mounted about 6 inches from the Brewster window, adjusting its vertical angle (pitch) causes the mode structure to change as the mode volume shifts position in an attempt to continue lasing. This may be part of the difficulty in getting other wavelengths to lase - the dominant 632.8 nm line is sucking all the power even when the mirror/prism assembly isn't well aligned with the bore and internal HR mirror. It may also be the due to reflectivity characteristics of the external mirror I'm using in conjunction with cruddy optical surfaces.
I then moved the wavelength tuning assembly to the laser described in the section: Mirror/Optics Test Jig Using One-Brewster HeNe Laser Tube since it could be mounted more than 18 inches from the tube's Brewster window which should restrict the mode options. Even with a pair of .040" diameter stops in the internal beam path (one at the Brewster window and the other just before the wavelength tuning assembly) - which makes alignment much more of a pain - I still cannot obtain any confirmed sightings of non-632.8 nm wavelengths.
Part of the problem is that I don't know if I'd really recognize something that was just another shade of red like 640.1 nm and certainly not 629.4 or 635.2 nm as different colors so I would really have to use a spectroscope to be sure - which I don't have. A simple diffraction grating won't work (at least not easily) since adjusting the tuning prism also moves the beam (that gets through the HR mirror) with this arrangement. This would confuse any measurements of angle or position. Only if I were to have two wavelengths lasing simultaneously would I see it with a diffraction grating - and that hasn't happened as far as I can tell. Orange at 611.9 nm would be easily seen as a different color but the gain of that line is quite low - about 1/7th of 632.8 nm and 1/3rd of 640.1 nm. That one has the highest gain of any visible line except 632.8 nm and is thus my best hope.
One option would be to attempt to use a diffraction grating on the reflection off the tube's Brewster window but even that will move around somewhat as the mode structure changes.
So, I still have the following unknowns:
* One-Brewster HeNe tube HR spectral reflectivity curve - I am still not sure that this mirror has the needed broadband response. The data I have are for newer versions of the 05-LHB-570 and may not apply to the tube in my surplus head. A quick test with a yellow (594.1 nm) HeNe laser indicates a high reflectivity at 594.1 nm - perhaps 99.9% - but that could be off by an order of magnitude. So an inadequate internal HR is still a possibility. And, of course, there is absolutely no chance of green (543.5 nm) lasing since the HR reflectivity at 543.5 nm will be way down and green gain may be even lower than that of yellow.
* External mirror spectral reflectivity curve - The SP084-1 HR mirror I am using may be designed to kill non-632.8 nm wavelengths. I have now tested the SP084-1 mirrors using that yellow probe beam: The HR and OC are 99% and 98.5% reflective at 594.1 nm, respectively. The HR's 99 percent is much too low to permit yellow lasing. I haven't tested the orange (611.9 nm) and other red (640.1 nm) wavelengths but suspect that the reflectivity for orange will also be inadequate though 640.1 nm may have a chance. In any case, I need to find myself a decent broadband HR.
* Wavelength tuning assembly selectivity - This includes the dispersion of the prism in conjunction with the mode volume of the HeNe tube and mode structure accommodation that is taking place. I don't have the option (at least not easily) with the one-Brewster tube of also tweaking its HR mirror alignment in an attempt to suppress the unwanted 632.8 nm wavelength as would be possible with a two-Brewster tube.
* Overall system losses - The three uncoated external surfaces (the tube's Brewster window and the two sides of the Brewster prism), external mirror and inside of Brewster window. Contributing factors include not quite perfect Brewster angle, dust, and gunk on the optics.
* Use of Mark-I eyeballs as wavelength measuring instrument. :) This would only apply to other red lines. 629.4 is not likely present. But, 640.1 nm may have high enough gain to lase and be close enough to 632.8 nm that I'd miss it. I'd certainly detect orange or yellow.
Well, I have yet to see a single photon of non-632.8 nm coherent light (though I guess I wouldn't recognize 629.4 nm), even using my LLNL 99.996 percent broadband HR mirror, two one-Brewster tubes in tandem, as well as using the HR from another high quality one-Brewster tube (all without the tuning prism). If anything should produce other color photons, it would be the tandem arrangement since that should be about equivalent to a single one-Brewster tube with an ideal (perfect broadband reflector) external HR mirror. I though I'd at least see 640 nm since that should be a strong line. With the Brewster prism tuner, I get a decently strong red beam, but nothing else even with a stop in the beam to restrict the modes and the tuner located a foot and a half away from the B-window to give it more sensitivity. I can see the reflection of the bore light of the tube come back and hit the stop and its color changes nicely without affecting alignment as the tuner is adjusted, just no lasing except at 632.8 nm.
I wonder if the older 1-B tubes had significantly crappier mirrors or the gain of that relatively short (10") tube is just too low. I did try to determine the reflectivity of the 1-B tube's HR at 594.1 nm from a yellow HeNe laser but the results were inconclusive - high enough to possibly be satisfactory but not nearly perfect. There are also a bunch of other variables which I may not have gotten all just right yet.
(From: Lynn Strickland (stricks760@earthlink.net).)
> "On the multiline experiment, any idea on the order of magnitude losses on your optics? I.e., scatter and absorption? Not that the actual number is that important, but it can kill you in a hurry when you're looking for non-red light. Make sure that puppy is ultra clean, too. I'd tend toward lasing massively multimode red (make it scream), then bounce the output beam off of a grating. The other lines should be in there - you almost can't escape getting 640 nm, and 612 nm isn't that tough.
>
> I've also got multiline lasing by stacking two HRs together (one behind the other). Actually, get it lasing with one HR, then put the second behind it and tweak appropriately. It's not stable by any means, but you can get it to lase. Finally, when you are tuning (I assume tilting) the prism, are you sure you're not walking-off, out of alignment as you tune? Bottom line, try to get multiline lasing first, worry about tuning to a single line later. A wavelength tunable HeNe is a bitch!
>
> Anyway, the older B-tubes definitely had crappier mirrors."
From data acquired from my multiline HeNe laser experiments (see the section:Getting Other Wavelengths from Internal Mirror HeNe Laser Tubes), I now believe that the SP084-1 mirrors are quite selective for the 632.8 nm line and their reflectivity drops off enough to suppress other wavelengths. I also know that even a Climet 1-B tube with a Hughes 1-B HR or another Climet 1-B tube in tandem will not produce a single non-633 nm coherent photon. If none of these configurations result in even unstable lasing at other wavelengths, there will be little hope of doing so with the tuning prism assembly.
More to follow.
### One-Brewster HeNe Laser Resonator Considerations
Here are some guidelines for construction of a resonator and for experimentation with the Melles Griot 05-LHB-570 one-Brewster HeNe laser tube like the type inside the CLIMET 9048 laser head. Other models may differ somewhat but this should be a good starting point.
* Minimum mirror reflectivity: The round trip gain of this HeNe tube is between 4 and 6 percent). Therefore, R must be greater than 96 to 94 percent respectively, for any lasing to occur. As noted in the previous sections, there are a wide variety of readily available mirrors that meet this requirement.
* Mirror reflectivity for maximum output power: This will be in the range where R is 98 to 99.5 percent. I don't know exactly where the peak is but R = 99% works quite well.
* Mirror reflectivity for maximum intra-cavity power: Obviously, this will be where R is as close to 100% as possible. However, above about 99.99 percent, it probably doesn't make that much difference and mirror quality and Brewster window cleanliness dominate.
* Acceptable mirror types: High quality dielectric mirrors with the desired reflectivity at 632.8 nm are by far the best. However, some metal coated mirrors will also work - barely. I have confirmed this with what appear to be either protected aluminum or enhanced aluminum mirrors from barcode scanners but no other types. I rather suspect the latter because the peak reflectance would be around 95 percent, compared to 90 percent for typical protected aluminum. This based on a chart from Melles Griot. (There will, of course, be no output beam with any of these since aluminum is quite opaque.) However, aluminum mirrors are not all created equal and many won't work at all due to low reflectivity or poor quality or both.
* Mirror radius of curvature: The radius of curvature (r) of the HR mirror in the Melles Griot 05-LHB-570 HeNe tube inside the CLIMET 9048 laser head is 60 cm. Based on the g1*g2 parameters (see the section:Resonator Stability) and experiments, a planar mirror will work almost up to L = 60 cm and a mirror with r = 60 cm (concave) will work almost up to L = 120 cm. I leave it as an exercise for the reader to determine the usable range for a convex mirror. :)
* Transverse mode structure: This HeNe tube will operate multimode unless forced to do otherwise (with a stop inside the cavity). The actual mode structure will depend on a variety of factors, the most important being the radius of curvature (r) of the external mirror and the distance between mirrors (L). Shorter radii result in more complex mode patterns and in general, none of them look much like what you will find in a laser text! You can use a short focal length positive lens to expand the beam to view the mode pattern on a screen.
* Wavelengths: So far, I've only been able to obtain lasing at 632.8 nm, the common 'red' HeNe color. I suspect that 640.2 nm should also be possible since this may have 1/2 the gain of the 632.8 nm line and the HR mirror should still have decent reflectivity but it may take the combination of a line selecting prism and a special OC mirror which suppresses the 632.8 nm line. I have no idea about other colors but suspect the HR mirror isn't broadband enough. Too bad. :(
* Resonator construction: With its wide bore, resonator rigidity and precision isn't as critical as with a similar length TEM00 laser. To get something built quickly, a thick base made of high quality laminated hardwood will even suffice. This can be reinforced with a couple of metal strips like those used to hang shelving.
### Alignment of Open Cavity HeNe Lasers
The general case of a one or two Brewster or perpendicular window setup is covered in Assembly and Operating Instructions for Open Cavity HeNe Laser Kits. For the special case of a one-Brewster tube, the summary in the next section may be all that's needed.
### Alignment of One-Brewster Open Cavity Laser
The following assumes the internal mirror is reasonably well aligned, that the distance from the internal to external mirror forms a stable cavity, and that the Brewster (B) window and external mirror are clean.
The external mirror should be adjusted (X,Y) so that it is centered on the optical axis of the tube. A piece of transparent plastic (like clear packing tape) should be placed between the mirror and tube while doing this to prevent accidental lasing and protect your remaining good eye. :)
Here are several techniques that are simple and generally successful:
1. External mirror reflection: The external mirror will reflect the bore light back to the tube. For cathode-end Brewster windows, it will be readily visible if the external mirror is within a few inches of the Brewster window, or even further if in a darkened room especially for cathode-end B-windows where there is not a lot of spillover of bore light. For anode-end B-windows, a shield can be fashioned from cardboard or something similar to block the bore light outside the tube.
As the reflected bore light and bore approach coincidence, there should be lasing.
2. B-window reflection: The external mirror will be visible when looking at the B-window. When the bore of the plasma tube appears centered within the mirror, lasing should occur.
WARNING: When laser starts, there will be a beam reflected off the B-window into your eye. For typical short 1-B tubes, this will be a few hundred µW at most but be ready for it. For high power HeNes, it could be over 1 mW.
3. Exhaustive search: Using the reflected bore light of (1) as a guide, detune the mirror alignment so the reflection is off to one side in both axes. The while rocking the mirror in X, incrementally rotate the adjustment screw in Y until a beam appears. (Or vice-versa.)
4. Use of alignment laser: If all else fails, by using a second laser (preferably green) reflected off the mirrors, the alignment can adjusted so that the reflected beam is coincident with the output going beam. Much more on this in the chapter:HeNe Laser Testing, Adjustment, Repair. That is mostly for internal mirror lasers but the same basic approaches apply.

Other Things to Build with One-Brewster Laser Tubes or Heads

One-Brewster HeNe Laser Heads in Tandem

For my next strange experiment, I decided to attach a pair of these one Brewster HeNe laser heads together - Brewster windows to Brewster window to see how high the circulating power could go. As long as the radium of curvature of the internal HR is greater than the distance between the two HRs, the resonator should be stable. A way to confirm this is to try a flat mirror as the external OC/HR. If the tube lases and can be aligned to a stable peak output power, the HR radius should be at least double the distance to the that flat mirror. Although there will be double the losses through the pair of Brewster windows, the gain will be more than double that of a single tube. The net effect should be nearly equivalent to a one-Brewster HeNe tube of twice the length with an optimum (super reflectivity) external HR.
With only one HeNe tube powered, the round trip gain is about 4 to 6 percent and with the additional Brewster loss, the beam won't be quite as strong as with just an external HR mirror. However, with both tubes powered, there will be a total 8 to 12 percent gain. This will result in a stronger photon flux inside the resonator and also provide enough gain margin to allow a variety of optics like etalons to be inserted into the cavity.
I attached the two tubes using 3 inch threaded standoffs with lockwashers between these and the flange of one of the tubes - a sort of oversize mirror mount where one of the tubes in its entirety is the mirror! The orientation is with the Brewster windows both facing the same way so hopefully, any offset of the bore will cancel. Lateral alignment is a challenge but with the large (1.4 mm) bore, it should be close enough to lase initially. Then, tweaking can be done once the basic alignment has been achieved. The configuration looked similar to High Photon Flux Laser Using a Pair of One-Brewster HeNe Laser Tubes in Tandem though perhaps not quite as polished. At least, that is what I thought originally.
However, this scheme will only work if the Brewster windows on the two tubes are oriented exactly the same way. On these laser heads, this is not always the case since it didn't matter for the original particle counting application. Thus an adapter would need to be added between them to allow for their relative angle to be adjusted precisely. Otherwise, the planes of polarization won't line up and there will be additional losses.
What I didn't realize initially was that the Brewster window alignment on my pair of one-Brewster heads was off by 15 or 20 degrees using the existing bolt holes. Since I wasn't that determined to construct additional parts for this initial test, I ended up just holding the tubes in position using the treaded spacers attached to one of them for guidance. Needless to say, this wasn't very stable. But, I did manage to get the combination to lase, if erratically. It looked like the potential was there for a high photon flux but without precise adjustment of the 5 degrees of freedom (X and Y between the bores; relative pitch, yaw, and roll) - plus cleaning the Brewster windows - there was no way to do anything consistent to optimize circulating power.
So, I constructed an adapter plate to correct for the difference in Brewster orientations. Instead of using a set of 4, full length threaded spacers, I used 2 sets of shorter spacers. They are attached using an aluminum plate with offset holes. With this contraption, I am able to obtain stable output. Apparently, the bore of the HeNe tube in each of these laser heads is aligned quite precisely with the axis of the cylindrical case - alignment is optimized when all the adjustment screws are tight. So, the only variables are X and Y position to center one bore relative to the other.
Given the distance between the two HR mirrors - about 60 cm, this turns out to be close to a confocal cavity. The beam waist is in the center and quite narrow - perhaps 0.75 mm - considering the large diameter bores. The assembly will lase with either tube energized but circulating power increases substantially when both are powered as expected. However, I was somewhat disappointed in that the circulating power and reflections from the Brewster windows doesn't seem to be that much more, if any, than with a single laser head and decent external HR mirror. But, I guess this is what should be expected: There will be double the available (real) power but also double the total losses so the circulating power remains about the same as with one tube and an external HR. What it does permit, though, is the placement of optics with much greater losses inside the cavity without causing lasing to cease entirely. For example, a high quality clean microscope slide can be inserted almost perpendicular to the laser axis and then tilted gradually resulting in periodic angles where there is lasing, thus acting as a sort of mode filter or etalon. For an explanation of this phenomenon (which shouldn't work at all just based on reflection losses), see the section:Perpendicular Uncoated Windows in a Low Gain Laser. Too bad there isn't any way to extract useful beam power - the only outputs at present are the 2 pairs of reflections from the Brewster windows.
I then decided to see what would happen if the area of the circulating flux was shielded from air currents by wrapping the tubes with some clear plastic. Without the wrap, any dust particles in the air would just cross the beam almost instantly without being affected in any detectable way. Now, however, if not actually being attracted to the beam, the dust particles were at least lingering there for a very long time. Perhaps it was may imagination or inspired wishful thinking or just a manifestation of the internal convection currents set up by the warm tube-ends, but it appeared as though some of the individual bright specks would tend to travel along the beam, occasionally as far as the Brewster windows, before disappearing. Perhaps this is a poor-man's version of optical tweezers where high photon flux can be used to capture and manipulate small objects like biological cells or aerosol particles. (Such a scheme would also work, of course, with any other sufficiently high power beam but the tandem dual tube setup allowed the area of the beam to be easily enclosed.)
### Mirror/Optics Test Jig Using One-Brewster HeNe Laser Tube
If the internal HR mirror of a one-Brewster HeNe (or other) laser tube has a long enough radius (RoC = 2 times the focal length), it should be possible to extend the resonator quite a distance out from the Brewster window. With a flat external mirror, this would be to R distance from the HR, longer with a curved mirror external mirror.
So, I built a jig that would allow a mirror (or other optic) to be fastened in position and aligned, and then moved along the axis of the tube, from just beyond the Brewster window to about 30 cm further away while maintaining alignment (more or less). See Mirror/Optics Test Jig Using a One-Brewster HeNe Laser Tube. For the optical rail, I salvaged the ball bearing slides and pen carriage from a defunct strip chart recorder (the same one that yielded the metal stock for my two-Brewster laser and other projects, very useful!). This isn't quite the equivalent of a $2,000 Newport slide but scroungers can't be too selective. :) I mounted a mirror/optics mount similar to others I've used for laser resonators (a fixed and movable plate fastened at 3 corners using cap screws and lockwashers for the springs) rigidly to the carriage. The mounting surface will accomodate both the endplates of HeNe tubes like the SP-084-1 as well as theSimple Mounting Cell for Salvaged HeNe Laser Tube Mirrors.
To align the entire rig, I installed a planar mirror for an OC on the carriage and aligned it for maximum output. Then, using the beam spot visible on the OC, I adjusted the height of the one-Brewster laser head at both ends (just using the slop in the bolt holes) and the side-to-side position of the rails so that the spot was centered at both ends of the carriage's travel. It isn't perfect but I can pretty much maintain lasing from end-to-end with only minor fluctuations due to imperfect alignment. The simple mirror mount is quite precise and quite adequate for fine adjustment even at the far end of the rails.
This test jig permits various mirrors to be installed in an adjustable length resonator and provides easy access to an extended space inside the cavity. And with an external HR mirror and resulting high photon flux, this setup should work reasonably well as a high-tech insect attractor (with unknown consequences at present) though I bet insects are blind to 632.8 nm light. :)
Some initial experiments:
* Using a planar mirror, lasing could be maintained with almost 30 cm between the Brewster window and the mirror (greater than 55 cm between mirrors). Assuming the HR mirror is curved, the cavity will be stable until r = L (thus forming a hemispherical resonator configuration) where r is the radius of curvature of the HR and L is the distance between the HR and OC). These results would be consistent with an HR that has a radius of curvature of 60 cm as I've been informed for these one-Brewster HeNe tubes.
* The mode structure changes as the distance between mirrors is adjusted. At the limit just before lasing ceases at maximum L, the beam is quite narrow and may approach TEM00 though I haven't actually confirmed this. In between, the number and configuration of the mode spots varies dramatically. But why should I spoil all the fun! You will have to do the experiments yourself. :)
* With the OC from another deceased SP084-1 HeNe tube, lasing would continue over the full extent of travel of my test rig. Since this mirror is curved, the cavity could be stable until L = r(HR) + r(OC) at which point it will form a spherical cavity. I guess I need a longer setup.
But something absolutely fascinating happens when L equals exactly 60 cm. :)
An alternative to the ball bearing slide which should really be just about as good and can be made almost any length desired is to use 1"x1" right angle aluminum stock for the rail (with the corner up) and a similar short piece positioned on top of it holding the mirror mount. Or, find a defunct printer and salvage the tracks and head mounting. Or, better yet, a pen plotter: The pen assembly is mounted on a ball bearing carriage which moves on tracks that are very precise and may be quite long (e.g., greater than 34 inches for an E size plotter!). And, no one wants those beasts nowadays having replaced them with faster lower hassle ink jet technology.
And here's an interesting experiment: It's possible to determine the speed of light fairly precisely by making measurements of the longitudinal mode spacing as the cavity length is varied. Implementation and calculations are left as en exercise for the student. :-)
For some more ideas of what can be done with this rig, see the section: Experiments With the Mirror/Optics Test Jig Using One-Brewster HeNe Laser Tube.
### HeNe Laser Tube Test Fixture
I have also built a setup similar to the basic one-Brewster tube laser using the salvaged aluminum tube from a different (deceased) one-Brewster laser head which originally housed a Hughes style one-Brewster HeNe tube that had been broken in half. As far as I can tell, it may have been in a fire as two other laser heads were destroyed in a similar manner and one of them had a very melted Alden connector! I got them from a laser surplus place (free along with some other stuff), who of course, didn't have any idea what happened. The label on the head (which also appeared to be heat damaged) said LHB-568 which probably meant it was the Melles Griot model 05-LHB-568 (surplus places may drop the '-05'). The tube looks similar to my 05-LGB-580 (green, see below) but with a normal (red) HR - a high Q (and no doubt very expensive) design with an optically contacted fused silica Brewster window (I saved that at least!).
The head is of slightly different construction than the CLIMET 9048 and includes two sets of Nylon screws (4 each) about 6 inches apart to support and fine adjust the position of the actual HeNe tube. After removing the remains of the old tube and a thorough cleaning the aluminum cylinder turned out to be ideal for use in testing one-Brewster and 0 degree window HeNe tubes. Bare tubes can be easily installed and then fine adjusted with four degrees of freedom (front X,Y and rear X,Y) to precisely center and align the bore to the mirror or other optics.
* Melles Griot Style One-Brewster HeNe Laser Tube Mounted in Test Fixture shows a Melles Griot 05-LHB-570 configured with the OC mirror from a Spectra-Physics model 084-1 barcode scanner HeNe tube.
* Anode-End One-Brewster HeNe Laser Tube Mounted in Test Fixture shows a Melles Griot 05-LHB-270 configured with the OC mirror from a Spectra-Physics model 084-1 barcode scanner HeNe tube installed in a mirror cell. (This also happens to be one of the less common tubes with the Brewster window connected to the high voltage.)
* Hughes Style One-Brewster HeNe Laser Tube Mounted in Test Fixture shows a Melles Griot 05-LGB-580 (green!) configured with a matching external HR mirror (see below for details).
* Window HeNe Laser Tube Mounted in Test Fixture shows a Melles Griot 05-LHP-120 which had lost its OC mirror coating similarly configured. (For details on this tube, see the section:Damage to Mirror Coatings of Internal Mirror Laser Tubes.)
Both Melles Griot and Hughes style tubes can be easily installed. Initially, I used this setup to test several bare 05-LHB-570s (one from a disassembled CLIMET 9084, a pair of similar tubes from another source, and another pair of similar size tubes that had the Brewster window at the anode-end (stay clear of the high voltage!).
A very similar setup can be built using the aluminum cylinder from a defunct HeNe laser head or other sort of pipe and 8 nylon thumbscrews with blunt ends. Carefully drill and tap sets of 4 holes equally spaced around the perimeter of the cylinder at 2 locations selected to hold your tube(s) securely. As with the commercial laser head described above, 4 rather than 3 screws allow for more intuitive adjustment of tube position for fine alignment. The entire assembly can be secured with clamps or (via additional holes) with screws and brackets.

External Mirror Laser Using HeNe Tube with Missing Mirror Coating

I was given a Melles Griot 05-LHP-120 HeNe laser tube which had a most unique problem - the coating on the inner surface of the OC mirror had vanished, probably due to the discharge taking place at times to the mirror mount instead of the cathode can due to a bad internal connection. See the section:Mirror Coating Vanishes for more information on this tube. Except for the residual annular ring of good mirror coating on the OC (see Melles Griot 05-LHP-120 HeNe Laser Tube with Missing OC Mirror Coating), this tube could be mistaken for something like a Melles Griot 05-WHR-570, a real window HeNe tube.
Although everyone including my inside contact at a major HeNe laser company said it would be impossible to get anything out of the damaged tube, I refused to give up even though none of my initial tests resulted in any coherent photons. However, the appearance of the window (formerly, the OC mirror) was just soooo perfect that I couldn't give up. :)
### Persuading the Tube to Lase
I can now report some success in getting this tube to lase with an external mirror - though just barely at first. Using the setup shown inWindow HeNe Laser Tube Mounted in Test Fixture, I was able to get perhaps two to three whole microwatts (that's 2 to 3 µW - count 'em all!) of output power at 632.8 nm - just detectable on my laser power meter - with the HR mirror from a deceased Spectra-Physics 084-1 HeNe tube. I used a 1 mW HeNe laser to confirm that the internal HR mirror was correctly adjusted by lining its beam up with the window tube's bore and checking that the reflected spot was centered in its output aperture. Then, without moving anything, I installed that SP-084-1 HR mirror and tweaked it so that the spot reflected from it was also centered. After powering up the window tube and a bit of jiggling, I got the weakest imaginable flashes - evidence of lasing - erratically while the discharge was going to the mirror mount. At first I thought it needed the extra gain of the discharge inside the mirror mount to kick it over the threshold but later I got it to lase when the discharge reverted back to its proper home in the cathode, though possibly with lower power (if that is possible!). In both cases, everything must be extremely borderline because even after fine tuning the HR and external mirror alignment, the output never quite settles down but varies in intensity and comes and goes seemingly at random. Even a slight change in the alignment of the window (by adjusting the locking collar) affects output power (what of it there is!). Oh well, an interesting exercise if nothing else but perhaps not worth writing home about. But I think I could get a carrot to lase at this point. :)
### Obtaining Respectable Output Power
A few days later, I tried the OC mirror from one of those SP-084-1 tubes. To my surprise, that worked much better in the output power department - up to .15 mW (yes folks, that's milliwatts!). Then I moved the OC mirror about an inch closer to the end of the tube - now about 1 inch away - and that boosted the peak power to about .3 mW! But it still appeared to be very erratic - flickering and coming and going at random even when the discharge was perfectly stable. And, even just blowing past the end of the tube changed output power noticeably! Had it been operating just at threshold with the HR mirror, I would not have expected any output at all with the additional loss of close to 1 percent of the OC mirror (which has around 99 percent reflectivity). What this suggests is that the losses from the original OC glass are low enough that the laser is operating well above threshold for the tube's gain but between the reflections from the front and back surface of the OC mirror glass and, several longitudinal modes are competing for attention.
### Analysis of the Strange Behavior
Here is the configuration:
Internal Original OC External
HR X1 X2 SP-084-1 OC
99.9% Bore 1-4% .25% 99%
| =============== ) ) )
<-------- L1 -------->
<---------------- L2 ---------------->
In fact, it appears that the contribution of the slight reflection from the inner surface of the OC glass (X1) is actually necessary for lasing. But, this forms a dual Fabry-Perot resonator with 3 reflective surfaces. Ignoring the AR coated outer surface of the original OC glass (X2), these are the internal HR mirror, the inner surface of the original OC (X1), and external SP-084-1 OC mirror. With such a configuration, the alignment and even length of each half of the cavity becomes extremely critical. As confirmation, pressing on the mirror mount toward the tube (not changing alignment) resulted in the beam coming and going as the length of the overall resonator (between the tube's HR and external OC) changed ever so slightly and the permitted modes shift compared to those inside the HeNe tube (between its HR and X1). In essence, what is created is an interferometer which includes the inside of the HeNe tube. Each cycle represents a shift in position of the order of a wavelength of 632.8 nm light - gentle pressure on the supposedly rigid mirror mount would cause it to go through a dozen such cycles!
(A fully accurate mathematical treatment of the topic of multiple cavity effects is way beyond the scope of this document but should be present in a comprehensive laser text. What follows is more along the lines of hand-waving to just give the general idea.)
The combination of the critical alignment of the intermediate and external mirrors, and the continuously changing lengths of the parts of the resonator made any determination of causes of the erratic behavior very confusing. Observing the fluctuating output power in this new light (no pun....), a cycle of about 20 seconds to a minute became apparent - almost certainly due to the heating and expansion of the tube cavity length (L1) relative to the total resonator length (L2). So, if I were to wait until the temperature of the tube stabilized, much of the erratic behavior should disappear.
The general resonator arrangement is shown in HeNe Laser Resonator with Intermediate Mirror (not to scale). The L1 and L2 modes drift past each other as the tube expands and the distances change. When a peak of the weak L1 mode function coincides with an L2 mode at a portion of the HeNe gain curve with a sufficiently high gain, output power is at a maximum. For the setup above, the overall gain is sufficient for lasing only about 20 percent of the time. However, that cycle isn't sinusoidal since the L1 and L2 modes are moving with respect to the HeNe gain curve and each-other. In the center of the gain curve, there is a smooth from 0 output to maximum power and back again. However, where two L1 modes are approximately balanced on either side, lasing could start with one and jump to the other resulting in the more random behavior described above.
And as if that's not enough, the curvatures of the middle surfaces (X1 and X2) complicate matters! There should be an optimal distance from the external (also curved) OC to the tube where the wavefronts will have the same shape for best constructive reinforcement. However, given that the curvature of the original OC was designed to produce a parallel output beam, it may be that a flat external OC would match the wavefront best, though I've yet to get a flat external mirror to work at all.
Assuming the reflection from X2 can be ignored, the change in L1 relative to L2 is the major cause of the instability and fluctuating output power with contributions from wavefront shape due to the (curved reflective surfaces) as well as the presence of an internal Brewster plate (not shown) in this linearly polarized HeNe tube. What a mess! :)
I later noticed that this analysis is somewhat incomplete. There is also reflection from the OC to X1 which needs to be in phase with the other two. This will happen automagically when an integer number of wavelengths fit between the HR and OC AND HR and X1. However, given this additional condition, I believe the response function will be more peaked with narrower areas of lasing with respect to X1 position - which would appear to agree with the observed behavior. How's that for hand waving? :)
It has been suggested that this power fluctuations are simply due to normal model cycling with a low gain resonator. I don't believe this to be the case for two reasons:
1. The original OC mirror glass of the 05-LHP-120 must be properly aligned to get the most output power, perhaps to get any output power. If it weren't involved in the lasing process, shifting it slightly off axis should have had no significant effect.
2. The general behavior is very similar whether an HR or OC (about 1 percent transmission) are used for the external mirror. If simple modes cycling were to blame, I would have expected a much higher percentage of on-time with the HR than the OC since the overall losses would be much lower. I later tried an OC with over 2 pecent transmission (from a 20 mW HeNe tube). While output power was a tad less than with the 1 percent OC, everything else was similar.
It is well known that an optical flat or etalon with two uncoated surfaces can be inserted into a low gain laser cavity like this with minimal losses if positioned at an angle close to the perpendicular such that destructive interference takes place for the lasing wavelength at its surfaces resulting in almost no reflections. The mechanism for this is explained in the section:Perpendicular Uncoated Windows in a Low Gain Laser. Perhaps what I should do is find a plate with one AR coated surface and attach this to the OC - which should be equivalent to a pair of non-AR coated surfaces. Then, just maybe, the combination would permit this laser to operate more normally. :)

Inexpensive Home-Built Frequency or Intensity Stabilized HeNe Laser

So you need a frequency stabilized HeNe laser? Or, maybe you'd just like to be able to impress your friends by saying you have a laser with a frequency of exactly 473.61254 THz! Here's how to do it cheap with similar performance to systems costing thousands of dollars. In fact, a perfectly usable stabilized HeNe laser can be built with less than 10 parts in addition to the laser tube and its power supply!
First, some of the issues involved in stabilizing a HeNe laser are addressed.
After that, its on to stabilization using a single photodiode and very short HeNe laser tube. This is the simplest approach since only a single photodiode and no polarizing beamsplitter is needed, it requires a very short HeNe laser tube.
Then, several sections deal with the more common and only marginally more complex two mode stabilization techniques that provide better performance and allow for greater flexibility in selecting a suitable HeNe laser tube.
There is also information on two-frequency Zeeman split HeNe lasers and intensity stabilization without regard to frequency.
### Single Mode or Dual Mode Stabilized HeNe Laser
It might seem intuitively obvious that building a single frequency stabilized laser using a tube that operates on only a single longitudinal mode would be easier, better, or perhaps even essential. But this isn't true at all.
The issue here isn't necessarily whether a HeNe laser tube operates on a single longitudinal mode, or more than one. But, rather whether the feedback circuitry uses a single photodiode to monitor the amplitude of 1 mode, or two photodiodes to monitor the amplitudes of 2 orthogonal modes.
Starting with a tube that supports 2 or 3 (or sometimes even 4) modes as long as there is a way of extracting a single mode so single frequency operation is guaranteed when the laser has stabilized has advantages:
1. Using the ratio of the power in two adjacent modes, rather than the power of a single mode, provides superior frequency stability. The ratio - usually set to be 1:1 - will remain quite constant with respect to absolute frequency but the power in each mode may vary as the tube warms up and over the tube's lifetime as it ages with use. However. The exception is when the laser is to be intensity stabilized. Then, a single mode (rather than the ratio of two modes) is compared to a reference in the feedback loop. Since adjacent modes are generally orthogonally polarized in a random polarized HeNe laser, it is a simple matter to use a polarizing beamsplitter to provide two photodiode channels which will then represent adjacent mode signals. The overall approach is shown inDual-Mode Single-Frequency Stabilized HeNe Laser.
2. Likewise, separating out a single mode for the single frequency output is easily done using a polarizing filter or polarizing beamsplitter. Even a 9 inch (225 mm) tube will only oscillate on at most 3 modes when one of them is nearly centered on the gain curve. When these lasers are frequency stabilized with 2 adjacent modes of equal power (ratio of 1:1), this prevents any other modes from oscillating. For intensity stabilization, the dominant mode is locked closer to the center of the gain curve and there may be 2 other modes lasing, but they won't appear in the final output since they are orthogonally polarized relative to the dominant mode and blocked by the polarizing optics. Single-Mode Single-Frequency Stabilized HeNe Laser.
3. HeNe laser tubes supporting 2 or 3 modes are much more common than true single mode tubes. In fact, true single mode tubes are virtually non-existent. Even tubes as short as 4 inches (about 100 mm), produce two modes during part of the mode sweep, though they are probably single mode much of the time. And the longer tubes can be designed to have much higher output power.
As general guidelines assuming the doppler-broadened neon gain curve is about 1.5 GHz FWHM and gain is insufficient for lasing beyond the FWHM:
* Maximum of 1 mode: The tube would need to be under 4 inches (100 mm) between mirrors so that the modes are more than about 1.5 GHz apart. Such tubes do not exist commercially. The reason is that aside from the low power that would be available from such tubes, the mode sweep would be 100 percent - the output would vary periodically from nothing to full power as the tube warmed up!
If such a tube did exist, it could be stabilized but would still require a polarizer between the tube and the photodiode to guarantee that the output was always polarized the same way when it stabilized.
* Maximum of 2 modes: The tube would need to be under 8 inches (200 mm) between mirrors so the modes are more than 750 MHz apart and three modes would not fit.
This tube could be stabilized using either the 2 mode ratio or 1 mode amplitude technique almost anywhere desired on the gain curve.
* Maximum of 3 modes: The tube would need to be under 12 inches. (300 mm) between mirrors so the modes are more than 500 MHz apart and four modes would not fit.
This tube could be stabilized using the 2 mode ratio technique with a ratio near 1:1. It could also be stabilized using the 1 mode amplitude technique if the dominant mode were positioned near the center of the gain curve and the output polarizer only passed that mode.
* Maximum of 4 modes: The tube would need to be under 16 inches. (400 mm) so the modes are more than 375 MHz apart and five modes would not fit.
This tube could be stabilized using the 1 mode amplitude technique if the dominant mode were positioned near the center of the gain curve. However, attempting to stabilize 2 modes with a 1:1 ratio would allow all 4 modes to oscillate, which would be unacceptable. However, such a tube could still be used with more sophisticated frequency stabilization techniques such as Lamb-dip or Pound-Drever-Hall locking. This is for the advanced course. :)
Now in reality, the gain may be sufficient beyond the FWHM of 1.5 GHz so that additional low amplitude modes could be present. Thus, the maximum lengths given above may be overly generous. A 9 inch (225 mm) such as used in commercial stabilized lasers like the SP-117A, will generally have a rather strong presence of a 3rd mode popping up at times.
It should be noted that when the stabilization is optimized for frequency, the intensity will still be maintained nearly constant, and vice-versa, but not quite as good as when it's the primary feedback variable. In principle, both frequency and intensity could be stabilized at the same time by adding a feedback loop for laser tube current to output power independent of mode position, but I don't know of any commercial HeNe lasers that provide that.
Beam sampling can be done using the waste beam from the HR-end of the tube if it is of adequate power and the power relative to the output beam doesn't change significantly with a change in tube temperature. The advantage of waste beam sampling is that it doesn't reduce the available output power and the sampling optics don't affect the main beam. However, some tubes produce a very low power waste beam or one that changes relative to the output beam as the tube warms up. (This is generally due to etalon effects inside the mirror glass between the mirror coating and uncoated outer surface modulating HR reflectivity as a function of temperature.) The main beam out the front can also be used but will result in some reduction in output power, and the sampling optics have to be of high quality and very clean so as not to degrade the output beam. Any technique that obtains the desired polarization components will work. These include polarizing beamsplitters, non-polarizing beamsplitters followed by polarizers, and Brewster-angle plates. One advantage of using the latter is cost since pieces of a decent quality microscope slide or cover slip will work fine to sample the main beam by producing near-zero reflection of one orientation and 10 or 12 percent reflection of the other to the photodiode.
The electronics required for stabilization using 1 mode (1 photodiode with or without polarizer) or 2 modes (2 photodiodes and polarizing beamsplitter) isn't all that much different and as noted above, either technique can be used with a 2 (or 3) mode tube. The two mode approach is better for frequency stabilization while the single mode approach is better for intensity stabilization, though not by a huge amount.
The output beam may consist of only a single mode - the other may be blocked by the beam sampling optics (if on the OC-end) or an optional polarizing filter (if beam sampling is on the HR-end). Other stabilized HeNe lasers may use a special tube with an internal heater or piezo transducer to control cavity length. See the sections:Coherent Model 200 Single Frequency Stabilized HeNe Laser, Melles Griot Stabilized HeNe Lasers, Description of the SP-117 and SP-117A Stabilized Single Frequency HeNe Laser,Teletrac Stabilized HeNe Laser, and Hewlett-Packard/Agilent Stabilized HeNe Lasers.
### Achieving High Performance in a Stabilized HeNe Laser
Specifications of a typical commercial mode-stabilized HeNe laser system (the SP-117A or 05-STP-901) are:
Stabilization Frequency Output Power
Technique Variation Variation

Frequency        +/-2 MHz      +/-1%  
Intensity        +/-5 MHz      +/-0.2%  

For complete specifications, see theMelles Griot Web site or the section: Melles Griot Stabilized HeNe Lasers.
While it is very easy to construct a laser that locks to one or two modes keeping them generally stationary as described in subsequent sections, providing performance comparable to commercial systems - order of 1 part in 108 - requires careful attention to design and implementation:
* Take time in selecting the HeNe laser tube:
* Where output power is important, a tube up to 9 or 10 inches will result in at most 2 lasing modes and an even longer tube may still have few enough modes when stabilized. See the previous section.
* Check for a "wedged" HR mirror by looking for a ghost beam along with the waste beam out the back of the laser tube. If a ghost beam is NOT present, there is no wedge, and the backreflections from the outer surface of the HR mirror will both tend to destabilize the laser as well as cause the waste beam power to vary due to the temperature of the tube and thus not track output beam power (important if the waste beam is to be used for mode sampling). Minimal power variation is particularly critical if intensity (one mode) stabilization is to be implemented. Most high quality HeNe laser tubes are at least supposed to have a wedged HR mirror (though mistakes have been known to happen!). But many barcode scanner tubes have the problem of varying waste beam power with respect to output beam power due to lack of wedge in the HR mirror. The Spectra-Physics 088s I've tested don't have this problem. But LGR-7641s and 098s - which are often used interchangeably in barcode applications - do. Indeed, many if not the majority of 6 inch barcode scanner tubes have variable waste beam power.
So whatever waste beam peculiarities may be present with one sample of any model tube doesn't necessarily mean they all will behave similarly since what happens at the back of the tube or even the slight output beam ripples would not impact the laser's important specifications. Checking for wedge and then testing the tube is the only sure approach.
Adding a wedge to a problem tube is theoretically possible, but the index matching has to be near perfect - even a 0.001% residual reflection at the parallel surface boundary will result in more than a 1 percent waste beam power variation. Where the HR mirror is frosted, rippled, or fine ground (non of these are common but may be present in rare cases), adding index matching cement and a wedge will still be desirable to minimize backreflections, though the effects uncorrected won't be anywhere as severe as with a plane parallel HR mirror glass.
More on this issue including an analysis and plots showing the waste beam behavior of otherwise normal red laser heads, as well as possible remedies, can be found in the section:Power Variations Due to Lack of HR Wedge.
* Monitor the mode sweep as the tube warms up. The most desirable tubes will be those that are not "flippers" (they have smooth mode sweep), and there must be no erratic behavior. Testing can be done with a polarizer of some sort to select one of the polarized modes, a simple photodiode, and a multimeter on the mA range. Enclose the tube in some sort of thermal insulation so it will get at least as hot as when installed with a heater in your stabilized laser. The mode(s) should change smoothly from close to zero to maximum and back in a periodic but slowing cycle with no jumps either way. The use of a data acquisition system would make this much less of a hassle than watching a meter readout for an hour! :)
However, note that a flipper that always flips on the same slope of the mode sweep regardless of temperature or the presence of small magnetic fields, will also work fine. A tube that switches from flipping to non-flipping behavior, or vice-versa depending on temperature may also be suitable. All that's required is to be able to select the feedback polarity to lock on the slowly varying (non-flipping) slope of the mode sweep. This can be done in the electronics or by using the appropriate polarization(s) in the beam sampler. But some flippers are inherently unstable and extremely sensitive to environmental conditions and back-reflections, so this would need to be checked. The only downside would seem to be that the option to lock on the "blue" side (upper frequency) or "red" side (lower frequency) of the gain curve won't be available for each mode, so the desired one (should this matter to anyone!) will have to be selected optically with a polarizer.
Unfortunately, I don't know of any way to select a tube by make, model, or length to guarantee acceptable performance in this applcation. Where a particular characteristic like variable waste beam power is irrelevant for the intended application, even tubes with identical model numbers may differ dramatically in waste beam behavior and stability. Spending some time to identify the best available tube will avoid loads of frustration later. The tubes used in many commercial stabilized HeNe lasers are common models that have been specially selected for good behavior.
* Provide adequate optical power to the photodiode(s) from the waste beam if possible, or from a beam sampler in the output beam. A minimum of 10 µW to each photodiode is probably comfortable. But, sampling the output beam, while more complex and reducing the usable output power by 5 to 10 percent, may be less trouble in the long run since there are no issues of inconsistent waste beam and output beam power. Non-polarized beamsplitters can also be used with polarizing filters in front of each photodiode. You don't need to buy polarizing filter stock - every LCD panel has a polarizing film pasted to the front and back surfaces. Their extinction ratio is typically only about 30:1 but that's adequate for this purpose. And I bet there are plenty of dead gadgets around your place with LCDs! :) Careful use of a razer blade will free the film and WD-40 will clean up the adhesive residue.
* Prevent back-reflections into the laser tube from the photodiode(s), polarizer(s), or output optics. Angle all optics and the photodiode(s). Block room light from hitting the photodiode(s). Include apertures to only allow the waste or sampled beam to pass, not the bore light.
* Provide thermal isolation of the tube assembly from rapid environmental changes such as air currents. An aluminum head cylinder or Plexiglas case will work. But don't insulate the laser to the point where heat can't excape - that is needed to enable the feedback loop to be closed!
* Provide mechanical isolation of the tube assembly using resilient mounting techniques (springs, RTV silicone, etc.).
* Use a regulated HeNe laser power supply for the tube. Although some commercial systems use special low noise power supplies, not all do. But one of those would be even better. A high quailty supply that runs on low voltage DC may be almost as good.
* Use regulated linear DC power supplies for the controller.
* Use proper analog design and construction techniques to minimize noise pickup. These include a single point ground and shielding, twisted pairs, and/or filtering of low level signals.
In fact, typical commercial stabilized HeNe lasers are really quite simple despite their high price, burying a common HeNe laser tube inside their expensive laser head with not much more electronics in their main feedback loop than a couple of op-amps. For example, the Coherent model 200 uses a standard Melles Griot HeNe laser tube but it has been selected to be a non-flipper and so forth based on criteria similar to those presented above. It produces two longitudinal modes, an external heater, and orthogonally polarized beam sampling. (Yes, the tube is from Melles Griot, not Coherent!) The Spectra-Physics models 117 and 117A (and identical Melles Griot 05-STP-901) use an SP-088-2 or the equivalent Melles Griot 05-LHR-088 tube, similar to those in barcode scanners, but higher power. Using both polarizations provides better frequency stability since their ratio can be easily maintained to be equal, independent of output power, which can vary as the tube warms up and as it ages with use. The 117A and 05-STP-901 also can be intensity stabilized which maintains the output constant based on feedback from a single mode. Many other companies have sold or still sell these types of stabilized HeNe lasers including Newport before they merged with Spectra-Physics (and probably acquired the technology from a long defunct company called Laseangle), Zygo, Teletrac, Nikon, Micro-g Solutions, SIOS, NEOARK, Nikon, Mark Tech, and many more.
### Stabilizing a HeNe Laser Tube Using a Single Mode
By using a short HeNe laser tube with a large mode sweep percentage (or with the addition of a polarizer to isolate a single mode), the laser can be locked to a specific power of the waste beam (or sampled output beam) with minimal circuitry. This results in the simplest implementation. But if you want to build a stabilized laser, consider one of the two mode approaches described later in this chapter. They are only slightly more complex but potentially can provide better performance.
The following description was inspired by the paper: "A Very Simple Stabilized Single Mode HeNe Laser for Student Laboratories and Wave Meters", B. Stahlberg, P. Jungner, and T, Fellman, American Journal of Physics 58(9), September 1990, pp. 878-881. Copyright American Association of Physics Teachers. I have edited the description just a bit and extended it to allow the use of a wider variety of tubes.
(Portions from: Steve Roberts.)
1. Find a 0.5 to 1.5 mW (actual output power) random polarized HeNe tube in the range of 4 to 9 inches (100 to 225 mm) from mirror to mirror. Barcode scanner tubes work just fine. These are readily available from surplus dealers and on eBay.
2. Test the HeNe tube by installing it in a steady mount with no drafts or air currents around it. Apply power and check the following as it warms up for at least 20 minutes. Check for the following:
* Adequate output power: If the main beam isn't strong enough for your needs, then there's little point on using the tube. However, simply for an experimental stabilized laser, this is generally of little consequence. However, a tube longer than 9 or 10 inches may have too many longitudinal modes to allow stabilization with a single mode output.
* Well behaved mode sweep: Slowly rotate a polarizer (e.g., Polaroid sheet) in the output to locate the axis of the polarization for the modes. Most random polarized HeNe laser tubes will have adjacent modes which are othogonally polarized with a fixed orientation. As the modes sweep through the neon gain curve, the output power from the polarizer should vary smoothly from a minimum to a maximum with a cycle that gets longer as the tube gets warmer and the rate of expansion slows. At 4 orientations 90 degrees apart, the output power will vary the most and for a short tube, will likely go to zero and stay there periodically. This is good. Mark these orientations on the tube for future reference. But if the output power changes erratically, abruptly, very little, or not at all, the tube should NOT be considered suitable for the stabilized laser project.
* Consistent waste beam and output beam power: If the waste beam will be used for sampling, this is important for your sanity. It also has implications for stability even the waste beam is not being used for anything. Monitor the power in the waste beam and output beam simultaneously to assure that they track each-other fairly closely. With some mirrors, the temperature of the mirror has a strong effect on reflectivity due to etalon effects inside the mirror glass between the mirror coating and uncoated outer surface resulting in a periodic variation in effective HR reflectivity as a function of temperature. As an example, for a 1 mW tube with an HR mirror reflectivity of 99.97 percent producing 30 µW in the waste beam a change of even 0.01 percent (from 99.97 to 99.96 percent) would result in an increase of 10 µW in the waste beam. If the waste beam was used for intensity stabilization, that would be a 33 percent change in the amplitude! But, it may be difficult to find a tube that is really perfect in this regard since it's not something that most applications care much about. An even simpler initial test is to shine the waste beam on a white card in a dark room and look for a ghost beam off to the side. If one is present, then the HR mirror was ground with wedge and is less likely to suffer from this problem. If there is no wedge, it will be necessary to add an angled plate to the HR mirror using an index matching cement (5 minute Epoxy may be satisfactory if care is taken not to trap bubbles in it during mixing.)
The best way to do these tests is to use use a data acquisition system or laser power meter with a graphing display capability to monitor the output of one of the polarization orientations (through a polarizing filter) for the main beam and waste beam. The power should appear along the lines of either the red or blue plot ofPlot of Melles Griot 05-LHR-640 HeNe Laser Tube During Warmup (Polarized). The 05-LHR-640 is a very short tube so the valleys of the plot may not be as flat or even go to zero power on yours. But the power should always vary smoothly with no abrupt changes. Compare this toPlot of "Flipper" Aerotech OEM1R HeNe Laser Head During Warmup and the closeup of flipping behavior inPlot of "Flipper" Aerotech OEM1R HeNe Laser Head During First Part of Warmup, which are the mode power variations of an otherwise healthy 1 mW HeNe laser head with a chronic case of flipperitis for much of the warmup period. :) The flips are virtually instantaneous, probably order of a few hundred photon round trips in the laser resonator. Also note that the frequency of the mode cycles for a flipper is double that of a normal tube - each mode would normally be what resulted from tracing the continuous curve and not taking the discontinuities as is evident inPlot of "Flipper" Aerotech OEM1R HeNe Laser Head During First Part of Warmup (Combined). So following red-blue-red, etc., ignoring the green lines.
However, at some point in the warmup period something very interesting occurs: The tube seems to revert to being well behaved! This only happens within a half dozen or so mode sweep cycles of thermal equilibrium and is consistent from run to run. The cause is unknown, nor is it known whether the tube would continue to behave if stabilization was attempted. It may indeed behave since the temperature at which it would run is well above the transition point.Plot of "Flipper" Aerotech OEM1R HeNe Laser Head at Transition to Normal Behavior (Combined) shows the abrupt change from flipper to non-flipper in stark detail. Note that the "envelope" of the mode plot is virtually unchanged at this point but the green transitions have disappeared. There are at most 3 or 4 additional complete mode cycles beyond what is shown and then the temperature of the tube is in equilibrium with its surroundings with only small slow fluctuations remaining.
3. Obtain a metal film type lab heater that will run off of your power supply, or wind a bifilar heating element using resistance wire or even fine magnet wire. A bifilar winding is desirable to cancel the magnetic field from the heater and is made by carefully wrapping a pair of wires side-by-side for the length of the winding. Short them at one end and drive the coil via the two wires at the opposite end. Since equal and opposite current is flowing along the pair of wires, virtually no external magnetic field is generated. However, an even better arrangement (but one very difficult to do by hand) is longitudinal back and forth glued to the tube. This results in a much higher bandwidth and more predictable response. But that's for the advanced course. :)
As a guideline, the maximum heater power should be about the same or a bit more than that of the HeNe laser tube. So, for example, if the laser tube is 4.5 mA at 1,400 V (6.3 W) like the SP-117A, a 7 or 8 W heater should work. For a 12 V power supply, this would have a resistance of around 20 ohms. The paper actually suggests double this - about 15 W - which is fine as well and would provide a wider operating temperature range and faster warmup, but also results in higher power dissipation in the driver.
A home-built heater can be made from magnet wire salvaged from a relay, solenoid, or other similar device. Magnet wire can also be purchased from an electronics distributor. Or, thin film heaters can be purchased from suppliers like Minco. Home-built heaters are less expensive and easily customized to the desired dimensions and resistance/power, but commercial heaters are more convenient since they can be moved from one tube to another without unwinding a hundred turns or more. :) But if your time isn't factored in, they are also much more expensive - $30 or more for a single heater!
4. Mount the tube at its center with a long aluminum ring and RTV Silicone, or two rings near the ends as long as the tube is free to expand slightly (it doesn't need much - about 0.1 mm!). However, the center ring mound may better isolate the tube from the environment.
5. Install this assembly in a tight metal box that keeps out stray light and lets the tube reach thermal equilibrium. Painting the box black inside might help to minimize stray reflections causing instability but really isn't necessary as long as the sampling optics/photodiode are enclosed. You can even put the entire thing in a box with a Plexiglas cover.
6. Poke a hole for the output beam in the box. Use the waste beam off the rear mirror to illuminate a broad area photodiode. Using such a photodiode eliminates the effects of beam wander on the sensor surface. It is very important to arrange the photodiode so there are no back-reflections into the laser tube. Even a very small amount of power back into the laser cavity can destabilize it. At the very least, it will increase the noise level, but might also cause the modes to flip polarization at random times even for an otherwise well-behaved tube. To prevent back-reflections, angle the photodiode (and polarizer) and don't mount them too close to the mirror. To help this, as well as to minimize bore light shining on the photodiode, attach something opaque to the mirror that has a hole only large enough for the waste beam to pass. A red filter to block out most of the bore light would also be desirable.
7. Although a short tube may have up to a 20 percent output power variation with mode sweep, most are lower and may make reliable and stable locking rather finicky. More importantly, without some means of locking to a specific mode polarization, the polarization of the output when stabilized will randomly be one of the two orthogonal modes. Therefore, I (Sam) recommend adding a polarizer between the tube and photodiode, oriented based on the mark placed on the tube, which will result in a much larger signal swing and fixed polarization orientation when stabilized. The paper mentions the use of a polarizer, but sort of as an afterthought. The polarizer can just be a tiny piece of a Polaroid sheet.
8. Any garbage op-amps can be used - 741s, LM358, etc. Use regulated +/-15 VDC power supplies.
The photodiode has its anode grounded and its cathode feeds the negative input of the first op-amp and the positive input is grounded. The value of the feedback resistor will depend on the actual amount of power in the waste beam or sampled beam. The paper used 330K ohms for a BPW34 photodiode and their specific tube, with a 47 pF shunted across the 330K ohms to assure stability. (This may not be needed but won't hurt.) For typical short Uniphase tubes, 1M or even higher may be desirable to obtain a nice large signal swing.
The differential amp is a second 741 with a 1M ten turn pot as its feedback resistor, and two 10K resistors as its inputs, one on the - terminal and one on the +. The plus terminal is fed off the ten turn 50K pot which has a 1M trim pot on its high side, to set the upper limit. The high side is fed to +15 V through the 1M trimmer, and the low side is of course grounded. The negative terminal goes straight to the trans-impedance converter's output via the second 10K input resistor.
The second op-amp then feeds a Darlington transistor pair made with a small signal NPN and a 2N3055 that has the heater in its collector circuit. Use a 1K between the opamp output and the Darlington base. Put an ammeter on the heater.
And, of course, shield everything.
Principle of operation: When the tube contracts the mode tens to drift to a higher frequency and thus the intensity of the output beam decreases, provided you start with a mode on the high side of the gain profile. As the converter voltage falls it approaches the set point of the pot and the heater is energized more (set quiescent heat for about 4 watts) the tube expands, forcing the mode frequency to decrease and sliding the beam to a higher gain point of the curve. To ensure your single mode, run the polarizer test again, adjust the set point so you only have 1 mode with no drift. (For the longer tubes, getting a single mode may not be possible at a reasonable set-point. So, just add a polarizer in the output.)
The authors of the original paper achieved a stability of 50 MHz with this method, over long periods of time, as compared to a commercial polarization stabilized HeNe using a beat frequency method. This will get you a better then 1% amplitude (or intensity) stability. God only knows what it does to the coherence length, as I have no way to measure that.
I (Steve) didn't come up with this, I just built it, and have seen similar methods used on a surplus measuring interferometer. The nice variation is to run this beam through a 40 MHz AOM, and beat the frequency shifted beam against a non-modulated sample, then phase lock it to a 40 MHz crystal, but thats time consuming and needs a critically designed RF amp and photodiode circuit as the second order correction. I used a short aerotech tube that is no longer made.
The original article gives full theory. They showed a drift as little as 2 MHz over 15 minute time spans, and as little as +/-6 MHz over an hour compared to the reference laser, and the locking frequency is repeatable to 50 MHz if you switch the unit on and off.
(From: Sam.)
That 50 MHz uncertainty could probably be reduced greatly if the temperature of the tube was monitored during preheat and then the feedback loop was enabled at the same temperature every time.
Note that the feedback loop described above is for all intents and purposes, pure gain or proportional control. The paper does suggest using an integrator and more sophisticated techniques but I suppose since the intent was to do the simplest possible implementation, there were no details.
I would expect the coherence length of this laser (or of any other home-built thermally stabilized HeNe laser) to be quite long at any given instant - possibly hundreds of meters or in the same league as a commercial stabilized HeNe laser - if the tube is isolated from vibration and AC magnetic fields, and the power supply is well filtered. What is not available with this scheme, which may be used in some commercial models, is high bandwidth piezo control of mirror spacing so there's no way to deal with short term fluctuations. However, the commercial stabilized HeNe lasers I've seen just use the heater approach. I do think that you could do better than the authors of the paper have achieved and match or exceed the performance of typical commercial systems with enough care in construction, particularly with respect to these factors above, as well as feedback for thermal control, and providing adequate thermal insulation (but not total isolation).
By using two longitudinal modes and straddling them on either side of the gain curve (see the next section), it should even be possible to spec an absolute wavelength/frequency to 9 or 10 significant figures. What other device can you build at home that can claim such precision?! :)
Here are some additional references that may be of interest:
* Frequency Stabilization of Internal Mirror Helium-Neon Lasers, R. Balhorn, H. Kunzmann, and F. Lebowsky, Applied Optics 11, p. 742, 1972.
* Stabilization of Multimode HeNe Laser: A Vivid Demonstration of Thermal Feedback, F. Stanek, R. G. Tobin, and C. L. Foiles, Americal Journal of Physics 61 (10), p. 932, 1993.
* Frequency Stability Measurements on Polarization-Stabilized HeNe Lasers, T. M. Niebauer, J. E. Faller, H. M. Godwim, J. L. Hall, and R. L. Barger, Applied Optics 27 (7), p. 1285, 1988.
I am considering making a kit of parts available to construct a basic one or two mode stabilized HeNe laser. This would be suitable for an advanced hobbyist or an university undergraduate course project. It would use a preselected non-flipper 6 inch (150 mm) tube with 12 VDC input HeNe laser power supply, microscope slides used as Brewster plate polarizing beamsplitters for the main beam, photodiodes, and a wrap-around heater for the tube (type to be determined). I may also include the required electronic components. The electrical schematic from which to start would be the same as that given in the next section, but could be enhanced if desired to provide separate s and p polarization signals, for example. Mounting would be up to the ingenuity of the student. Most of the parts are not very expensive but having them all from one source would simplify things. And starting with a HeNe laser tube that is known to be well behaved would eliminate a lot of potential frustration. I welcome comments on whether there would be any interest in such a kit.
The parts list would go something like: * Tested HeNe laser tube guaranteed NOT to be a flipper. 0.8 to 1.5 mW, 150 mm length, mode spacing of 1,063 MHz typical. * Beam sampler plates (2), to be used at the Brewster angle to provide approximately 10 percent of the output power to each polarization from the output-end of the tube. * Silicon photodiodes (2), relatively large area, 0.4 A/W typical sensitivity. * Wire to construct a heater or thin film heater for the tube with approximately 25 ohm resistance. * Quad op-amp, MJE3055T heater driver, assorted resistors and capacitors.
### Sam's Stabilized Two-Frequency Helium-Neon Laser
The approach above can be extended to use a somewhat longer HeNe laser tube, one having a longidtudinal mode spacing as low as 600 to 700 MHz or one with a magnet to perform Zeeman splitting, to build a two-frequency stabilized HeNe laser similar to commercial models. Before you get too excited about maybe having a HeNe laser that outputs red and green light, the two frequencies I'm talking about will differ by 600 MHz to 1 GHz (less than 0.0015 nm at 632.8 nm) for the laser described in this section and up to only 2 MHz or so (less than 0.000003 nm) for the two-frequency laser based on Zeeman splitting, below. Looking at a 600 MHz signal may be stretching it for a home lab but a 2 MHz beat signal can easily be seen with very modest equipment.
A two-frequency laser can be built by using a HeNe tube that will support a pair of longitudinal modes (maybe the same tube as the one used above or one that is slightly longer) and monitor the two polarization orientations of the waste beam (from the HR) with with a pair of photodiodes. A suitable servo system would then control the heater temperature to equalize the intensity of the two outputs. This would result in operation with a pair of adjacent longitudinal modes of orthogonal polarization separated by a frequency of c/(2*L). Whether an 'even' mode and next higher 'odd' one or an 'odd' mode and next higher 'even' one is stable would depend on the sign of the feedback equation. Such a feedback system would not be much more complex than the one to maintain a single frequency output. I have thrown together a very simple and preliminary design which can be found at Sam's Stabilized Helium-Neon Laser 1. I was intending to construct it at some point but ended up building the even simpler one described in the next section instead. :)
The HeNe laser tube should be one that's random polarized and between 5 to 9 inches in length, rated about 0.5 to 2 mW with a mode spacing of between 1.2 GHz and 600 MHz. From some quick tests, the shorter tubes seem to have very pronounced cycling of polarization with almost perfect nulls, but 3:1 or 4:1 even with the 9 inch tube. Having the nulls is fine but the tube has to be able to support two modes simultaneously which means that there should be some times at which there will be little or no evidence of polarization of the beam indicating that more than one mode but hopefully only two modes are oscillating. Even if up to 3 modes oscillating at timnes is acceptable if one of them is near the center of the gain curve. Keeping the tube length below 9 inches should guarantee this. The tube will be enclosed in a thermal control system consisting of a bifilar wound heating element, aluminum heat distribution layer, and outer isolating layer. Note that this mustnot be a totally insulated (adiabatic) system since there is no way to cool the tube actively. Thus, thermal conduction to the ambient is a requirement. The purpose of the outer layer is to isolate the tube from air currents and other disturbances that would produce frequency fluctuations that would occur too quickly to be handled by the thermal control system.
The mode sweep behavior of any candidate tube should be tested by monitoring its output through a polarizer, oriented to produce maximum change from minimum to maximum signal during mode cycling as the tube warms up. The power should vary more or less smoothly without any abrupt jumps or dips which would indicate that the tube is a "flipper" - one where the modes suddenly swap polarization states as described above.
The beam from the HR-end of the tube is passed through a polarizing beam splitter to create the S and P oriented beams for their respective photodiodes. The TL072 op-amp implements a differential integrator feeding a darlington heater driver. At first, I was going to use an SG3524 PWM controller chip but then realized that the AC switching frequency would result in both electrical noise and some residual magnetic fields even with the bifilar wound heater coil. Thus, I changed it to a linear regulator. Depending on the heater power (and thus the maximum power dissipated in the regulator, a large or forced air-cooled heat sink and/or multiple pass transistors may be required.
The heater would be driven during initial warmup at a constant current around half of what it can safely handle. At this power level, the warmup time is not critical as long as it is long enough, allowing the temperature to stabilize to the point of near equilibrium. The feedback loop would be off until the tube is close to a steady state condition due to the balance between its discharge current heating, thermal input from the heater, and thermal leakage to the environment. This point could be determined by detecting when mode cycles take more than 20 to 30 seconds. Then, the heater will have to run at around the same power to maintain lock. Using a higher heater power would get to this point faster, but if you wait too long, the heater will have to run near full power to maintain it - or may not be able to at all even at full power. Switching over when the heater can run below half its maximum current (1/4 power) is probably better.
After preheating, the control system would be enabled and will seek a stable point equalizing two adjacent modes. If by chance, it started with a pair of modes which resulted in increased imbalance with higher temperature (greater distance between mirrors), it would stabilize at the next pair. If the feedback loop was switched on too early (even from a cold start!), the behavior would be dominated by the warmup-expansion due to the discharge current heating, but even then, it would probably stabilize eventually. Experimentation is welcomed. :)
See How to Build a Frequency-Stabilized HeNe Laser for information on a pair of lasers built based on these techniques.
### Sam's Home-Built SP-117 Compatible HeNe Laser
The Spectra-Physics model 117 (SP-117) was one of the classic commercial stabilized HeNe lasers with its successor, the SP-117A (and OEM SP-117C) in production until around 2007. For more info on this laser, see the section:Description of the SP-117A Stabilized Single Frequency HeNe Laser. (The SP-117 and SP-117A are functionally similar except that the latter can operate with intensity stabilization or frequency stabilization, and also has a low speed modulation input.) I have constructed a frequency stabilized HeNe laser from junk parts that consists of a laser head and bare-bones controller. The laser head will also operate from an SP-117 or SP-117A controller, and my controller will also run a stock SP-117 or SP-117A laser head, with at most minor adjustments to the premap gain settings. (This also applies to the Melles Griot 05-STP-901 which is identical to the SP-117A except for the color of the case and front panel layout.)
The special - and no doubt very expensive SP-117 (or 117A or 05-STP-901) laser head, should you need to replace yours - is of the typical design described above - a common random polarized HeNe laser tube (probably a Spectra-Physics 088-2 or Melles Griot 05-LHR-088) surrounded by a heater with polarizing optics and photodiodes to generate feedback signals for two orthogonal longitudinal modes.
I used a common barcode scanner HeNe laser tube, a Spectra-Physics model 088 (about 1.4 mW). This is about half the power of the 088-2 but it was available. :) Almost any other random polarized tube would work as long as it was 9 inches or less between mirrors.
The heater is about 50 feet of #36 AWG copper magnet wire wound bifilar-style around the tube on top of the original aluminum wrap after adding a layer of clear packing tape as insulation insurance. The bifilar winding is used to minimize the magnetic field of the heater that would result in Zeeman splitting - not desirable for this version of the stabilized laser. The length of wire was chosen to result in approximately the same resistance as the heater in the SP-117 laser head - about 20 ohms.
The photodiodes are common types found in barcode scanners and similar equipment (similar to thePhotonics Detectors PDB-107.) A Polarizing BeamSplitter (PBS) is used to separate the two modes of the waste beam from the HR mirror. The photodiodes are set at an angle to prevent reflections back into the laser.
The SP-117 controller's HeNe laser power supply runs at 1,700 V at 4.5 mA for the 088-2 tube. Therefore, the ballast resistance for the 088 tube was made 160K so that the power supply in the SP-117 controller would see about the same operating voltage. The 4.5 mA is nearly optimal for this tube as well.
One concern was that the waste beam may not have enough power for the photodiode preamps inside the SP-117 controller. About 25 microwatts for each of the two polarizations after the beamsplitter is the minimum that will work reliably with unmodified Spectra-Physics or Melles Griot controllers. This is because the feedback resistors are 500K ohm pots in the preamps. With 25 µW and the typical 0.4 A/W sensitivity of silicon photodiodes, this will result in a voltage swing of 5 V. If the power is much less than this, additional amplification will be needed. Or, sample the output beam instead. The power of the waste beam from the 088-2 is about 3 times that of the 088, so this was a concern.
Final assembly went very smoothly and the completed unit is shown inPhoto of Sam's SP-117 Compatible Stabilized HeNe Laser Head. Some windings of the heater are visible under the plastic covering. The small black cylinder on the left is the polarizing beamsplitter, borrowed from an SP-117 laser head. The photodiodes are attached at the rear and underneath. Awhile after the photo was taken, I found a half dead very small PBS in a Hewlett Packard 5500C interferometer laser head and substituted that, freeing up the SP-117 PBS to go back to its original home or for other purposes. (Part of the coating on the critical diagonal surface had rotted but there was enough remaining for beam sampling.) Yes, that's a piece of quad twisted pair blue Ethernet cable and the highly stable base is laminated hardwood with a suger maple stain. Who says optical systems can't be built on real breadboards. :)
The system powered up just fine. Even the polarities of the photodiodes were correct. The voltage swing of the photodiodes was much better than I had feared, about 2.5 V end-to-end (more on this later). The behavior during warmup was about the same as with the genuine SP-117 laser heads. And, after approximately the normal warmup time, it was quite clear from the photodiode voltages no longer changing, and the modes no longer changing (as determined by a polarizing filter), that the tube had locked. However, the Stabilized indicator never came on but for a momentary flash or two. The lock seemed quite solid with the laser remaining stable as long as it wasn't disturbed. Blowing on the tube might cause it to lose lock but it would regain it in at most a few mode cycles. (The only protection over the heater is several layers of thick plastic.) But the stable point was very near one extreme with one of the two modes nearly centered on the gain curve and dominating. This might be desirable to maximize the output power in the single mode, but is not as stable a location as with both modes on the slope of the gain curve and of approximately equal power.
As far as the Stabilized indicator, I think that what was happening is that although the voltage swing of the two photodiode channels is not that much worse than with the SP-117 laser head, the actual voltages on each of the photodiode channels is much lower. While for the 088-2 tube, a typical voltage swing is from 2 or 3 V to 5 or 6 V, for the 088, it is from 0.1 or 0.2 V to 2 or 3 V. Since the 088 is a lower power tube, there are probably only 2 modes maximum and the polarization extinction ratio is much higher than for the 088-2. So, the controller may be looking for the signals to be within a specific absolute voltage range, or may not like the lock being at one extreme of the range. This, too, is almost certainly something that an adjustment would remedy. But, installing a 1.5K ohm resistor across each of the photodiodes added an offset of about 2.5 V so that the voltage swing became 2.5 to 5 V. This was sufficient to keep the system happy. After the normal warmup period, the Stabilized indicator flashed a couple of times and my mode meter stopped nearly abruptly at dead-center. The laser was stabilized with the two modes of nearly equal amplitude, which is the desired outcome. In fact, there was less flashing of the Stabilized indicator before lock than with either of the genuine SP-117 laser heads, and it then stayed lit continuously. That's a good thing. Else, I would have had to just tape a Day-Glow red dot over the Stabilized indicator. :-)
I don't know for sure why the 1.5K ohm resistors produced the desired effect. Based on the design of the SP-117 photodiode preamps, it probably the result of the offset voltage of the two op-amps, and thus might not work in general. However, it would be simple to introduce the needed current in some other way if needed.
Next, I decided to build a very simple controller. In fact, the initial version constructed on a protoboard consisted of literally five (5) parts - 1 op-amp, 2 resistors, 1 zener diode, and 1 MJE3055T transistor. SeeSam's Stabilized HeNe Laser 1 (SG-HS1). The power input is 12 VDC. And, if a dual power supply (e.g., +/-6 VDC) were used, the zener and 1 resistor could have been eliminated, so 3 parts. :) OK, these simple implementations won't switch from constant heat mode to feedback mode automatically - there's a switch for that but the switch doesn't count as an essential part since it could be done by moving a wire! :) Locking was very stable with minimal overshoot. Grab the tube or block the waste beam to the photodiodes to force it to lose lock and when restored to normal, it will stabilize very quickly. In fact, the first time I completed the feedback loop, I thought that something was wrong when it settled down almost immediately.
The soldered refined version has a few more parts to implement PI (Proportional-Integral) control. It is shown inSam's Stabilized HeNe Laser 2 (SG-HS2). The "I" in PI control eliminates the offset error of the stable point resulting from the finite gain of the error amplifier which would change depending on the temperature of the tube and thus heater current. A pot to move the stable point over about 90 percent of the gain curve, a tuning input, and LEDs to show the relative intensities of the modes were also added. The LEDs also serve to show when the laser has locked, and roughly where on the gain curve it is sitting. There are now a grand total of 29 parts, but more than two thirds of them are for the non-essential bells and whistles. :) The only change that may needed to allow it to be used with any SP-117 compatible laser head would be to make the gain of the error amp adjustable but I didn't have any suitable pots handy.
SG-HS2 seems to work every bit as well as the SP-117 controller and perhaps better, at least based on general behavior. Admittedly, I haven't measured the frequency stability. Certainly, additional filtering and shielding would be needed to truly achieve similar noise specifications. But for now, this will have to do And, the entire circuit fits on a little piece of perf. board (overall dimensions less than 2x3 inches). See Photo of Sam's SP-117 Compatible Stabilized HeNe Laser Head and Controller. Yes, it's that little thing in the lower left corner! The power supply for the HeNe laser and the 12 VDC power supply for the controller are not shown, but that's all. Really! :) After the photo was taken, I couldn't resist adding a green LED for power, a yellow LED showing the approximate heater voltage (by its intensity), and a test connector with the mode difference signal (U1-1), the output of the PI amp (U1-7), the heater voltage, and ground.
Determining when to switch to "Lock" is generally no problem. Just set it on "Preheat" and wait until a full mode cycle takes at least 20 seconds or so. It should then stabilize in less than one additional mode cycle and remain at a fixed locking point, with the heater voltage nowhere near its extremes (0 V: too cold, 12 V: too hot, that LED is a good enough measure). For example, if the tube isn't hot enough, the modes will continue to slowly drift away with the heater totally off, and incapable of keeping the temperature from increasing due to the power in the HeNe discharge. In that case, switch back to "Preheat" and give it a couple more minutes. Another simple test is to switch to "Off" from "Preheat" and watch the mode LEDs. If it's hot enough, the mode display will immediately change direction as the tube cools. If the modes don't do much of anything or continue in the same direction, more heating is needed. As a practical matter, once an optimal minimum mode cycle time for switchover has been determined for a particular laser head, waiting until it occurs should be sufficient, and is basically what the "real" stabilized laser controllers do. For the rig shown above, it takes about 12 minutes in my approximately 65 °F seasonally adjusted lab. Or, count full mode cycles - about 72 after 12 minutes. You're welcome to add the logic if desired. :) Or, just wait a looooong time. :) Then the tube will reach thermal equilibrium but the heater is only driven at about 1/2 power in Preheat, so there will be ample head and foot room once switched to Lock
I have tested SG-HS2 with a genuine SP-117 laser head. The required warmup time is even shorter - less than 10 minutes. I'm not quite sure why that should be the case since the heater resistance (and thus power disspation) is similar). Possibly, it's due to the tube being enclosed by the head cylinder which provide thermal insulation. It would certainly be beneficial to enclose the tube in such a cylinder or other semi-insulating jacket to isolate it from air currents and other thermal disturbances.
SG-HS2 should drive a Melles Griot 05-STP-901 laser head with no changes (except maybe for gain as discussed above) since that stabilized laser is the same as an SP-117A. Adapting it to a Coherent 200 laser head may require minor changes (aside from connectors and such). I have not measured the maximum heater voltage required for that laser but suspect it is higher than 12 V because the laser head cylinder heats up more quickly and stabililizes at a much higher case temperature than the SP-117 even though the heater resistance is similar. The integrator time constant may also need tweaking.
So, who needs to pay $5,000 for a stablized HeNe laser. Aside from the cost of the HeNe laser tube, its power supply, and some sort of polarizing beamsplitter, this entire rig would cost nothing to build for anyone with a reasonably well stocked electronics junk drawer. And, for a laser jock, those other items will be in their junk drawer as well. :)
In additional to the stabilized HeNe laser, this basic circuit and ones like it have many other potential applications. For example, it could used as a fringe locker with a pair of photodiodes in quadrature sensing the interference pattern from a laser diode and using thermal control to adjust its wavelength.
Blank PCBs as well as a complete kit of parts are now available for SGHS2. The PCB is just under 2x1.8 inches as shown inPhoto of Sam's Stabilized HeNe Laser Controller 2It has a DB9F for the laser head (SP-117/A compatible), 3 pin header for power, and 2 pin header for modulation. Power requirements are regulated +12 VDC at 1 A. SGHS2 may be used as shown, or built into a project box with front panel controls in place of the switch and trimpots. For more info, please go toSam's Classified Page or contact me via the Sci.Electronics.Repair FAQ Email Links Page.
### Sam's Very Simple Stabilized HeNe Laser
I have now built a minimalist laser head using the single mode approach that runs from my SP-117 compatible controller. It uses a 6 inch barcode scanner tube with a single photodiode behind a polarizing filter stuck on the HR mirror mount. An adhesive dot painted black with a hole was stuck on the HR mirror to block bore light. The heater is approximately 50 feet of #36 AWG magnet wire wound bifilar-style over an aluminum wrap. The tuning pot on the controller is used to set the locking amplitude.
While locking was successful on the initial attempt after preheat, it only remained stable for a minute or so and then fliped polarizations and cycling through one set of modes before reacquiring lock. And then this cycle repeated continuously. So, this tube has turned into a flipper. Perhaps, I didn't test it thoroughly enough. I thought that perhaps, there were still some back-reflections that needed to be tamed given that the photodiode is so close to the HR mirrir. But even when the tube was allowed to warm up on its own without anything near the HR mirror, it still occasionally flipped, though not as consistently as is the case when the feedback loop is enabled.
I have now checked out several other 6 inch tubes both for non-flipping mode behavior and acceptable power in the waste beam. I found another tube that flips *all the time*. The power in one mode climbs smoothly until about two thirds of the maximum and then abruptly drops to zero. That mode looks like a sawtooth. :) But most tubes seem well behaved. Of the dozen or so tested, I've identified 5 that seem to be flip-free and have enough power in the waste beam to be usable without needing to increase the photodiode gain on my controller.
Installing a heater on one of the well behaved tubes eliminated the flipping problem. The laser now stabilizes easily and remains locked continuously, though the feedback loop is a bit underdamped if disturbed, possibly since the same wattage heater was used on a much smaller tube. This would be unimportant if the tube were installed inside some sort of enclosure to provide isolation from air currents - to which is is very sensitive. I may mount it in the cylinder from an 05-LHR-911 laser head, inside of which it should fit easily. I'll keep the original tube and heater assembly intact as an example of one not to use.
Then I discovered another issue: This tube has waste beam power that varies by almost 2:1 depending on the temperature. Once everything reaches equilibrium, this may not be that critical. But as it warms up even after locking, the output power can be seen to drift significantly even though the photodiode voltage is rock solid. Based on tests of other tubes with similar behavior, my conclusion is that the HR mirror was ground without wedge and is suffering from etalon effects. A change in effective reflectivity of only 0.03 percent would change the waste beam power by about 30 µW. For more on this phenomenon, see the sections starting with: Melles Griot Yellow Laser Head With Variable Output. Such variation wouldn't be quite as critical for two mode ratio stabilization, but for one mode intensity stabilization, the output power ends up inversely tracking the changes in waste beam power. So, it would be better to sample the output beam for the feedback.
So, I checked out the remaining tubes that had a well behaved mode sweep and found two others that had a minimal change in relative waste beam and output beam power from cold to hot (beyond that during normal operation). (I only checked those two, so it's possible I just got really unlucky with the bad one.) There is probably still some change but it is down near the limit of detectability watching a pair of laser power meters with the tube doing its mode sweep thing and the readings varying. (Recording the power of both beams as a plot would have been better.) Instead of almost a 2:1 change, it's more like +/-1 percent. But, this is still much greater than I would have expected before undertaking this exercise, since it never occurred to me to even check for such a problem, um, "feature", in a normal red HeNe laser. Using this tube results in much better performance with only a small drift after locking until thermal equilization is complete. When stuffed into the cylinder from an 05-LHR-911 laser head without end-caps, the short term stability is about +/-0.5 percent. If carefully packaged, it would probably be much better.
But, locking to a specific amplitude is more finicky all around than locking to a 1:1 ratio, which can be set and forgotten. :) So, this further suggests that the additional complexity of a polarizing beamsplitter and two photodiodes is well worth it unless the goal is intensity stabilization. And, sampling the output beam is also probably a better idea unless the tube is known to have very consistent waste beam and output beam power.
### Sam's Simplest Stabilized Laser Controllers
Would you believe two (2) electronic components in addition to the mode sampling photodiode and heater? Yes, it's true. This controller consists of a high value resistor and BUZ71 or similar N-channel MOSFET, and runs on 8 to 12 VDC. That's it! This is so simple that a diagram is almost not worth drawing:
V+ o--------+----------+
| |
| /
| \ HTR1
PD1 /_\ / 10 ohms
| \
| |
| |-+ Q1
+-------||-, BUZ71
| |-+
/ Gain |
R1 <--+ |
5M / | |
\ | |
| | |
GND o--------+---+------+
Or a nicer (but tiny, sorry) diagram: Sam's Simplest Single Mode Intensity Stabilized HeNe Laser.
A silicon photodiode is reverse biased from the positive power supply to the resistor. Adjust R1 so that the voltage to the MOSFET varies near ground to near V+. The exact value will depend on the power in the waste beam from the laser tube and the details of the polarizing beam sampler. The junction of the PD and resistor is attached to the gate of the MOSFET. The heater (10 to 20 ohms recommended) sits between the drain of the MOSFET and positive power; the source is grounded.
To operate, run the laser tube from its power supply and run the heater from the controller power supply direct until the tube is hot enough such that removing heater power causes the modes to reverse direction. As usual, this takes 10 to 20 minutes. Then allow the MOSFET to take control. :)
Of course, since this uses only one of the two polarized modes, it is an intensity, not frequency stabilized laser, and only for the mode that is sampled. There are no guarantees on performance other than that it will lock and remain locked to a specific mode. Since the feedback loop is proportional only (no integrator) with the gain provided by the resistor value and MOSFET transconductance, don't expect quite the same specifications as the SP-117A. However, it will still be a couple orders of magnitude more stable than a common HeNe laser, and will be single frequency like the others.
Victor Zhao, a high school student working at theLaser Teaching Center at Stony Brook University, Stony Brook, NY during the summer of 2008, and I actually built a stabilized laser based on this circuit in about 1 hour total. Most of that time was spent in Victor practicing his soldering skills and scrounging up a suitable MOSFET from another lab. But despite the MOSFET simply dangling in mid-air by its wires, the thing locked on the first attempt! I would have liked to include that photo. It's a classic! :) (I did later explain about the importance of heatsinks, but MOSFETS are tough.) Victor went on to achieve semifinalist status in the Intel Talent Search competition based on his subsequent work with stabilized HeNe lasers. More on Victor including the Intel paper atVictor Zhao's Homepage at the Stony Brook Laser Teaching Center. I've used an almost as simple "controller" for a proof of concept demonstration. See the section: Sam's Stabilized IR (1,523 nm) HeNe Laser. Since the original photo of Victor's laser seems to have been lost, the one there of a kludged prototyping board will have to do. :)
For better performance, use both polarizations with 2 photodiodes and 2 resistors. (That's 3 parts instead of 2 parts!) And perhaps make one of the resistors adjustable to set the stable point on the neon gain curve. The PDs should be in series reverse biased from the positive supply to ground and the resistors should also be in series to ground. The center taps of the PDs and resistors should be connected together and to the gate of the MOSFET as shown below:
V+ o--------+------+------+
| | |
| / /
_|_ R1 \ \ HTR1
PD1 /_\ 5M / / 10 ohms
| \ \
| | |
| | |-+ Q1
+------+---||-, BUZ71
| | |-+
| / |
_|_ R2 <-+ |
PD2 /_\ 5M / | |
| \ | |
| | | |
GND o--------+------+--+---+
Getting this scheme to work is left as an exercise for the student! :)
### Micro Stabilized Laser Controller 1 (µSLC1)
If you aren't sure which end of a soldering to grab, this one is for you. ;) It uses a 2Atmega328Nano3.0Arduino−compatibleboardshouldbeusablewithatmostminimalchanges.Onlyahand−fullofadditionaldirtcheappartsarerequired,primarilyfortheabsolutelyessentialuserindicatorLEDs.;−)See[Sam′sDigitalStabilizedHeNeLaserController1](sghs3p1.jpg).ItisprogrammedviaUSBbutdoesn′trequireacomputertorunthelaser.However,theµSLC1WindowsAppprovidesformonitoringoflaseroperationandpermitslaserjocktypestototallymessupthelaserbychanginglockingparameters.;−)Thetotalpartscostforwhat′sinthephotoislessthan2 Atmega 328 Nano 3.0 Arduino-compatible board should be usable with at most minimal changes. Only a hand-full of additional dirt cheap parts are required, primarily for the absolutely essential user indicator LEDs. ;-) See Sam's Digital Stabilized HeNe Laser Controller 1. It is programmed via USB but doesn't require a computer to run the laser. However, the µSLC1 Windows App provides for monitoring of laser operation and permits laser jock types to totally mess up the laser by changing locking parameters. ;-) The total parts cost for what's in the photo is less than 2Atmega328Nano3.0Arduinocompatibleboardshouldbeusablewithatmostminimalchanges.Onlyahandfullofadditionaldirtcheappartsarerequired,primarilyfortheabsolutelyessentialuserindicatorLEDs.;)See[SamsDigitalStabilizedHeNeLaserController1](sghs3p1.jpg).ItisprogrammedviaUSBbutdoesntrequireacomputertorunthelaser.However,theµSLC1WindowsAppprovidesformonitoringoflaseroperationandpermitslaserjocktypestototallymessupthelaserbychanginglockingparameters.;)Thetotalpartscostforwhatsinthephotoislessthan5. You add the optional PC. Like those above, it is designed to plug in to any SP-117/A/B/C or equivalent laser head, but could also be used with minor modifications with almost any other thermally tuned single or dual mode laser, as well as axial or transverse Zeeman lasers.
For more information, see the µSLC1 Installation and Operation Manual.
### Sam's Complete Two Mode Stabilized HeNe Laser
This is a compact self-contained stabilized HeNe laser built into a JDSU Novette case whose previous occupant has been evicted (dead tube and power supply) as shown in Sam's Compact Self-Contained Stabilized HeNe Laser 1 (SG-CSHL1). The Novette is already among the smallest common (non-stabilied) HeNe lasers, being just barely longer than the 6 inch Melles Griot barcode scanner tube inside. A 9 ohm wire-wound heater covers about two thirds of the glass part of the tube and a dual photodiode beam sampler using a PBS cube is mounted directly on the HR mirror. That makes the fit even tigher. At first I thought the beam-sampler would need to be external, thus the small non-functional hole in the back-panel between the USB connector and LEDs. But by using a 4 mm PBS cube and thin photodiodes, it only adds about 6 mm to the tube length. That much spare room was available. µSLC1 is installed inside the case with all of its LEDs mounted on the rear panel. Digital systems must have switches and lights! :-) (Though the only switch is for power - the microprocessor RESET button is not accessible.) It is powered by a 5 VDC, 2 A wall adapter.
OK, that was the objective.Sam's Compact Self-Contained Stabilized HeNe Laser 1 (SG-CSHL1) and Typical Warmup State Sequence shows the system in action. These are the states from a cold start through being locked (though not all instances of States 2, 3, and 4 are shown). Without the GUI (USB cable not connected), State 6 can never be entered. And there were of course no errors, so it never goes to State 7 with the red LED at the lower left being lit. ;-)
But there are "issues" to be overcome if it were desired to make this into a more polished system. :( :)
Once the HeNe laser tube and power supply brick are installed, there really isn't all that much room remaining. So, without designing a custom PCB, the Atmega 328 NANO 3.0 PCB and µSLC1 controller PCB had to be separated and even then it's a really tight fit. Furthermore the longer wires add noise. That's not surprising. But there is a problem with the USB interface - sometimes. While it's possible to upload firmware, the GUI won't always run - it simply resets the micro into a strange state which is nowhere to be found in the firmware. Then it does nothing. So, that's a mystery, but may be due to power glitches. The only known difference between this and the previous setups are that the +5 VDC input to the NANO is used for power all the time. There is a blocking diode on the NANO board so that it is supposed to take +5 VDC from either USB or external power depending on which is present. I don't know if it's a problem with how that behaves or noise on RESET or something else. It could be poor regulation of the wall adapter. Without the GUI, the modes can't be monitored directly and changes to the firmware require recompiling. The USB serial port runs as confirmed by the Serial Monitor in the Arduino IDE and the data looks reasonable. However, opening the serial port in the GUI caused the board to reset and restart, and it never thinks the laser is present. But miraculously, it seems to behave after warmup and the GUI starts normally, perhaps due to lower power consumption of the heater. :( :)
When the GUI runs, it's possible to do everything required. And with minor tweaks to the locking parameters, the laser will remain very stable for many hours or forever.
Given the difficulty in working inside this thing, I don't anticipate any changes, so consider this a proof of concept. Building ships in bottles is probably less hassle. :-) But for anyone who would like to do something similar, I'd recommend building a custom PCB with the Atmega 328 and everything else in one place using SMT components. ;-)
### Sam's Laseangle RB-1 Stabilized HeNe laser Conversion
Laseangle was a company that built some stabilized HeNe lasers in the early 1980s. I don't know if they ever actually sold anything commercially but there is a reference in a paper to the use of 6 of their systems. Perhaps, the researchers were related to the company founder. :)
I was given what must have been a prototype or testbed - the RB-1. The RB-1 consisted of two pieces as shown in Laseangle RB-1 Stabilized HeNe Laser Head and Controller. The connecting cables were nowhere to be found when these photos were taken. The laser head is S/N 1 and and the controller is S/N 2, so at least two of these systems were built. The thing clearly wouldn't be caught dead going out to a paying customer, though it's likely that the RB-1 or its successor eventually morphed into the Newport NL-1 (maybe "Newport Laseangle 1"?) as a result of a merger or buy-out. However, I've yet to see an actual NL-1 (or production RB-1 if there ever was such a thing).
The RB-1 laser head contained the HeNe laser tube, with wrap-around heater, a beam sampler assembly that diverted all of one polarization to a photodiode and part of the orthogonal polarization to another photodiode, and preamps for the photodiodes. The base is a 3/4 inch thick aluminum slab with a 1/8 inch aluminum cover sealed with foam rubber.
The controller housed what appears to be a standard Laser Drive HeNe laser power supply brick, DC power supply, feedback circuitry, and heater driver. There were controls on the front clearly not for an end-user, like 8 or 10 gain settings and a fine gain control for one of the op-amps, selection of which mode signal to pass to an output, a current meter for the heater, and so forth. People who typically use these things would have no clue of what to do with the knobs and switches. But I've yet to see a user manual!
While the mounting of the HeNe laser tube is somewhat overkill and the beam sampler is a nice solid unit with an adequate number of adjustments, the electronic construction of both the laser head and controller are, to put it politely, a disaster. Everything is on those copper strip prototyping boards, with capacitor upon capacitor added in various places no doubt to tame noise pickup or instability. (Someone must have had stock in a capacitor company!) The designers must have had a goal of using strange and hard to find connectors wherever possible which they did for the separate cables of the photodiode signals (blue multipin) and heater drive (microphone two pin). Power for the HeNe laser tube came from a standard Alden on the controller but at the laser head had both the medium voltage BNC on top for the positive and the normal BNC on the bottom for the negative. Someone must have been toasting marshmallows above the DC power supply voltage regulators since there is a nice brown spot on the ventilation grill there. I have no intention of powering up either the controller or the entire laser since the cables with their strange connectors are nowhere to be found, it's not worth constructing replacements, and the thing would probably explode in any case.
My mission was to convert the laser head alone into a basic self-contained stabilized HeNe laser suitable to use to demonstrate a simple stabilized HeNe laser. It will be donated to a university Physics Demonstration facility.
The original HeNe laser tube was from Uniphase, a garden variety model but was end-of-life - hard start, hard run, white-ish discharge color, and only about 0.4 mW of output (probably should have been around 2 mW). Its length of 8 inches is somewhat unusual - 6 or 9.5 inches being more common, at least today. While a 9.5 inch tube would satisfy the criteria for the number of modes, it would just barely fit, but with marginal clearance for the high voltage on its anode mirror mount. So, I installed one of the 6 inch tubes I'd already selected for well behaved mode sweep behavior. The beam sampler uses the main beam, so any variation in waste beam power is more or less irrelevant.
The original beam sampler included a polarizing beamsplitter cube to extract one of the mode signals and prevent it from reaching the output at all, and a separate angled plate to extract a portion of the orthogonal mode. A pair of EG&G SGD-100A photodiodes (may be similar to the Perkin Elmer FFD-100) fed LF356 op-amps. (EG&G is now part ofEXCELITAS.)
Of all this, only the angled plate and the mounting hardware for all the beam sampler stuff was retained. I wanted the beamsplitter cube for other uses but also needed to roughly equalize the power to the 2 photodiode channels to keep the new controller happy. (Single mode locking would probably have satisfied the design goals but it would only take a bit more effort to use both modes.) So, in place of the beamsplitter cube, I built a little angled mounting post and added a bit of an optical window to act as a plate beamsplitter. In place of the EG&G photodiodes which were too nice to use here, I installed a pair of my normal $2 photodiodes - which also have a larger area making them easier to align with the sampled beams. The red filters glued in the beam path in front of each photodiode to block bore light were left in place. A piece of Polaroid polarizing film was cut to fit in front of each photodiode to select the orthogonal modes. Some experimentation showed that one set of orientations resulted in approximately equal power in the orthogonal polarizations to each photodiode - within 20 percent - which would be good enough. For the other possibility, they differed by perhaps 2:1.
The new controller was constructed on a piece of perf. board to fit in about the same space as the original preamp. The rear panel of the laser head was modified to have a power switch, Preheat/Off/Lock switch, LEDs for the heater (yellow) and the two modes (red and green), the Offset pot, and a Tuning input BNC (more to fill the existing hole than to be something essential!). The original connector on the front of the laser head was left in place just in case someone would want to monitor various signals (though I have no intention of wiring anything to it at the present time). The orignal controller came in handy though. Its rubber feet were transferred to the converted laser head. :-)
The HeNe laser power supply is one of those little copper covered bricks made by Laser Drive for a variety of barcode scanners. It easily fits on the baseplate behind the laser tube. The system runs from 12 VDC at about 1.5 A max. A 2 amp fuse (in a socket) was included for good measure. These little plug-in fuses were about the only thing worth salvaging from the mainboards of Sparc-II workstations. :)
Views of the completed unit are shown in Laseangle RB-1 Stabilized HeNe Laser Conversion Rear Panel andLaseangle RB-1 Stabilized HeNe Laser Conversion Interior. Some labeling of the rear panel will be needed. Inside, the HeNe laser power supply is on the left next to the tube with its heater. The large black object is the modified beam sampler assembly with the red and green dots indicating which section is associated with the vertical (green) and horizontal (red) polarization modes. The controller is on the elongated perf. board with heatsink. The bare blue connector is left as an exercise for the student (or professor) to provide for signal monitoring.
The system now works like the one described in the section:Sam's Home-Built SP-117 Compatible HeNe Laser. After a 10 minute preheat period, it locks easily and will clearly be able to demonstrate the basics of a two mode stabilized HeNe laser. The control loop is a bit underdamped, probably because of the smaller thermal mass of the 6 inch tube. The wrap-around heater, originally used with the RB-1, is also slightly higher power. But if the user wants to play with the gain of the integrator, its proportional feedback resistor is in a socket (no pots in the entire thing). I just picked the first one that seemed reasonable. I make no guarantees on frequency drift or noise, but with the cover in place, the amplitude of either polarized mode settles down after a couple of minutes to a short term variation of less than +/-0.25 percent. Since it's locking on the mode ratio, the frequency variation this corresponds to should be quite respectable, probably less than +/-2 MHz. This is better than 1 part in 108!
I assume that the ugly cover will be replaced with clear Plexiglas. ;-)
Specifications (of sorts) and operating instructions for the SL-1 ("Sam Laseangle 1") can be found atSL-1 Operation Manual. There's a good reason it is under the "humor" directory, but the actual operating instructions are serious. :)
### Sam's Three Mode HeNe Laser Using Second Order Beat Stabilization
A three mode stabilized HeNe uses a longer tube and is capable of higher power in a substantially pure single output mode when it is centered on the neon gain curve. Suitable tubes are typically rated 5 to 6 mW, random polarized, and are around 350 mm in total length. And they must be well behaved in the normal ways - non-flippers with adjacent longitudinal modes being orthogonally polarized.
The only known example of a commercial stabilized HeNe laser using this technique was the Laboratory for Science (LFS) model 260. From their brochure:
> "In a laser with three TEM00 modes, there will be two primary beat frequencies corresponding to the difference frequencies between the central mode and each of the modes on either side of center. These two beat frequencies, typically in the range of 400 to 500 MHz, will in general not be exactly the same because the frequency pulling effects on each mode will vary with the differing slopes at the respective operating points on the Doppler gain curve. The difference between these two beat frequencies will yield a third or inter-combinational beat frequency typically in the range of 100 kHz. In an integral end mirror tube, where the alternate modes are orthogonally polarized, the inter-combinational beat frequency will not be zero even when the central mode is at line center because of the birefringence of the mirrors."
The inter-combinational beat frequency is a strong function of the mode position and can thus be used as the locking variable. Much more information on this technique can be found in the chapter:Stabilized HeNe Lasers (Coming soon).
What LFS calls the "inter-combinational beat", I'm calling the "Second Order Beat" or SOB because it derives from the interaction of the two primary or first order beat signals. More info on the LFS lasers may be found at Vintage Lasers and Accessories Brochures and Manuals.
A diagram of the prototype/testbed SOB stabilized laser is shown inThree Mode HeNe Laser Using Second Order Beat Stabilization. The tube I'm using initially is a Melles Griot 05-LHR-150 rated 5 mW but this sample does over 6 mW after warmup. It actually had to be slightly misaligned to reduce power so that there were no rogue 4th and 5th modes present on the tails of the neon gain curve when a mode is centered. A pair of photodiodes and PBS monitor the waste beam, though the variation in power in these signals is minimal (under 10 percent). An angled glass beam sampler plate directs about 10 percent of the output beam to a modified HP 10780A optical receiver, which generates the TTL beat signal. Eventually, a more sensitive custom optical receiver will be placed behind the tube in place of the PD-P photodiode. This would be preferred to avoid reducing the output power in the main mode. A photo of the hardware is shown in Three Mode HeNe Laser Testbed Using Second Order Beat Stabilization.
The controller will be based on µSLC1 but modified to use the beat signal as the locking variable and thus called µSLC2. ;-) The firmware hooks are already in place as a 16 bit counter was freed up in µSLC1 to monitor the REF signal with Zeeman lasers. The basic state structure will be retained except that locking will be based on the beat frequency instead of mode amplitudes. The GUI will change slightly to be able to monitor and plot the beat frequency along with the modes.
Stay tuned.
### Sam's Stabilized IR (1,523 nm) HeNe Laser
All of the previous examples stabilized HeNe lasers have been at the common 633 nm (red) wavelength. However, HeNe lasers come in multiple colors, both visible and invisible, and various applications may benefit from stabilized lasers at other wavelengths. For example, the IR HeNe laser operating at 1,523 nm is near the long end of the telecom S band and could serve as a very accurate wavelength/frequency reference.
I just happen to have a new random polarized Melles Griot 05-LIR-150 tube with an output power of around 1 mW. Simple calculations confirm that the tube length - about 35 cm (~14 inches) will result in fewer longitudinal modes than would be present in a 633 nm tube of similar length, which would have 4 or 5 modes and be completely useless for simple mode-based stabilization. The gain bandwidth of neon goes down approximately by the inverse ratio of the wavelengths. It's not exact because the constant homogeneous broadening also must be taken into consideration, but that's a difference of less than 5 percent, which is close enough for government work. :) Thus, worst case, a 35 cm 1,523 tube will behave more like a 14.5 cm 633 nm tube. A tube of that equivalent length would make a fine candidate for stabilization because at most 2 modes would ever be oscillating, and over a good portion of the mode sweep cycle, there would only be 1 mode.
The next problem was being able to look at mode sweep. Silicon photodiodes are not sensitive at 1,523, not even a tiny bit. Almost everything I've done to this point used Si detectors. I've got literally a drawer full of them. :) Useless!!! Thermal detectors are too insensitive and too slow. IR photodiodes tend to be pricey - over $100 for a small area bare device. And anyhow, buying something simply violates the spirit of the challenge. :)
This was solved after I recalled the use of cut open transistors as photo-sensors. (See the section:Photodetectors for Low Power Near-IR.) I have several dozen ancient 2N404 and 2N1308 germanium transistors. Preparing them for a new life in sensing takes only a few minutes.
To view the two polarizations would normally be done with a polarizing beam-splitter and a pair of photodiodes. I don't have a Polarizing Beam-Splitter (PBS) cube that works at 1,523 nm, though I do have a pair of IR plate polarizers and an IR non-Polarizing Beam-Splitter (nPBS) cube. However, all 3 optics are HUGE (25 nm polarizers and 20 mm nPBS cube) and I didn't feel like tying them up for these tests. So initially, only one polarized mode can be captured at a time.
The polarization axes were identified by maximizing the differences in mode shape and then oriented so they were horizontal and vertical. At first, the appearance of the modes was rather disappointing with no clear pattern and a major difference in power in the two polarizations. I knew from my transverse Zeeman HeNe laser experiments that magnets could greatly influence both the shape and balance of the modes in a short tube. And this tube is EXTREMELY sensitive to magnetic fields. Placing even something only somewhat stronger than a refrigerator (note sticking) magnet in the vicinity of the tube has a noticeable effect. A single such magnet up against the tube resulted in a mode sweep that was much better behaved, though the power in the two polarizations was still unbalanced. That is typical when operating in the transverse Zeeman regime at moderate field strength. But if it was also single longitudinal mode in one of the polarizations somewhere along the mode sweep, there would be hope of stabilizing the thing. Mode Sweep of Melles Griot 05-LIR-150 HeNe Laser Tube with Weak Transverse Magnetic Field is cobbled together from separate runs for each polarization, so they may not line up perfectly. I do believe they have the same scale factor and little or no offset so that difference in amplitude of the variation is real. But the overall shape wouldn't merit a second glance if it was from a red (633 nm) laser.
Mode sweep can provide information on the power in each polarization, but not the specific longitudinal mode(s) that are present. For that, a Scanning Fabry-Perot Interferometer (SFPI, sometimes called a "laser spectrum analyzer") is required. I have several SFPIs, both home-built and commercial, but none were set up for 1,523 nm. Then I recalled that the mirror set in one I had built was actually originally intended for telecom wavelengths, and "repurposed" for use with green (532 nm) DPSS lasers. (Mirrors that are HR at a wavelength of n, will be decently reflective at a wavelength of n/3, but not the other way around.) See Sam's $2.00 Scanning Fabry-Perot Interferometer. By simply replacing the silicon photodiode with one of the cut-open transistors, it could be converted to 1,523 nm. I have another SFPI that can be used at 532 nm, so the SFPI could be left that way permanently. Alignment was a bit tricky since the IR "PD" (the cut-open transistor) has a very small sensitive area AND has to be mounted at a funny angle so the light can reach it AND 1,523 nm is totally invisible AND the only laser I have that produces it is less than 1 mW AND my IR viewing scope doesn't go past 1,350 nm AND the preamp gain had to be cranked up until any signal was detected increasing the noise as well AND the room lights had to be out or else they would overwhelm the PD. But it turned out not be as terrible as I had feared - a bit of wiggling and jiggling here and there and some choice 4 letter words were all it took.
Once the 05-LIR-150 laser was displayed on the SFPI, it became clear that some work would be required to tame it. Adjacent modes generally didn't have any consistent polarization and were constantly changing. The modes in the two polarization axes had a large difference in average power, but otherwise looked somewhat similar. There would be no way of simply picking a lock point and expecting everything to automagically work out. With the addition of a single magnet in the same location as for the mode sweep test, above, the situation improved slightly, but it still wasn't single mode in either polarization for enough of the mode sweep to be useful. But with two additional magnets spaced along the tube, it looked like there would be a large range of single mode behavior for the polarization. In fact, with this configuration, it is pure SLM for most if the mode sweep cycle in both polarizations. This means that a normal dual-mode stabilization technique should work well. The behavior is consistent with a longitudinal mode spacing where three adjacent modes just fit within the neon gain bandwidth, which should be about 650 to 700 MHz for this IR laser assuming the net gain is the same as for a 633 nm tube. SeeLongitudinal Modes of Typical 1 mW Random Polarized IR (1,523 nm) HeNe Laser Tube with Magnets. But as expected from previous tests, the gain bandwidth appears to be somewhat wider. The mode spacing of the tube is 438 MHz, so the effective width of the neon gain curve (LBW or Lasing BandWidth) is closer to 900 MHz allowing the three modes to oscillate over a small portion of mode sweep. This is similar to the behavior of a 20 cm 633 nm laser as shown in Longitudinal Modes of Typical Random Polarized 3 mW HeNe Laser. (In fact these are the same diagrams with different numbers! :) The amplitude of the two polarizations appears to be similar. One peculiarity though is that the polarization axes are at about 15 and 105 degrees (not 0 and 90 degrees as shown in the diagram). I attribute this to the location of the magnets since he polarization does not change with rotation of the tube. The magnets are all on one side with their centers slightly below the tube bore. But the World (or at least the optical table) might have to be rotated by 15 degrees to line it up. :)
I have implemented the prototype as an intensity-stabilized laser using the (nearly) vertical polarization. This is partially due to the lack of a simple solution to the PBS problem. :) But, intensity stabilization should end up being nearly as good as frequency polarization once the laser tube has reached thermal equilibrium. And with the narrower gain curve at 1,523 nm, should actually be slightly better than at 633 nm due to the steeper slope with respect to frequency.
Now to the nuts and bolts. :) In the following description, refer toSam's IR (1,523 nm) Stabilized HeNe Laser Prototype which is a montage showing the present state of affairs. (As they say, you really don't want to know how sausage is made!), I'm using the case from a Melles Griot 05-LRR-871 self-contained 633 nm HeNe laser with its tube replaced with the 05-LIR-150. The slightly shorter tube conveniently provides space for the required beam sampler assembly. The tube has a Kapton thin-film heater from a defunct Teletrac/Axsys 150 laser loosely wrapped around it and secured with bell wire ties. :) The three (3) magnets can be seen obediently standing at attention on the right side.
The beam sampler is built on a block of wood - there has to be an optical breadboard in here somewhere!. It uses the variable attenuator plate from an Orion barcode scanner HeNe laser tube mount, here simply to act as a beam-splitter, where it is most transparent. This provides a few percent reflected to the cut-open 2N404 transistor used as an IR photodiode that can be seen angled in the background. Originally, I assumed that a polarizer would also be required in front of the photodiode. However, it turned out that the beam-splitter plate must be close enough to the Brewster angle that it already provides a decent amount of polarization selection for the nearly vertical polarization and the signal varies more than 3:1 during mode sweep. A true polarizer at the optimal orientation would probably produce a change of 15:1 or more, but 3:1 is plenty good enough. Murphy is suspected of having taken a millisecond off and allowed this violation to slip through. :)
To obtain enough signal amplitude, the output of the photodiode goes to a general purpose preamp. (See the section:Sam's Photodiode Preamp 1.) It must be set nearly at the highest gain available, but this provides a voltage swing from under 5 V to almost 15 V during mode sweep. The output is being monitored on the dual polarity panel meter with the cracked faceplate visible in the upper left photo.
The locking controller for these tests consists of voltage divider with a pot to conveniently adjust loop gain and a power MOSFET to drive the heater. And that's about it. :) OK, so the term "controller" may be a bit over the top :) but this is basically similar to the one in the section: Sam's Simplest Stabilized Laser Controllers. For "preheat", it is turned on with about 8 V on the heater. (A resistor to the gate of the MOSFET is stuck into the positive supply voltage!) At some arbitrary time when complete mode sweep cycles are taking longer than about 30 seconds, feedback is enabled. Adjusting the pot on the controller can then set the lock-point. The ancient Triplett VOM is monitoring heater voltage. (That fan in the background is not being used for these tests.)
My $2 SFPI is now enclosed in a nice aluminum shroud with end-caps from pill bottles to keep out stray light. It's being driven by a Wavetek function generator but the SP-476 photodiode preamp is being used to boost the signal level to the scope. There is a Melles Griot IR polarizer in the partial third hand between the laser and SFPI. The SFPI display shows a single pure clean peak confirming SLM operation. (The pair of peaks are due to the 7.3 GHz FSR of the SFPI.) When locked with the amplitudes of the orthogonal polarizations being between at less than 1:3 and more than 3:1 of each other, they are pure SLM and remain pure SLM and look similar. Unless disturbed, the laser will remain locked way indefinitely (or at least several hours, the limit of my tests). However, since there is no cover, any breeze, even a wave of a hand, may cause it to lose lock momentarily. But with the cover in place and perhaps an outer wrap over the heater, that should not be an issue.
So what does this prove and could a practical 1,523 nm stabilized HeNe laser actually be built based on this prototype? I believe that *this* tube could be used to create a reliable system. What I don't know is if all instances of the 05-LIR-150 would have similar enough behavior that such a laser could be replicated without rework each time. Unfortunately, Melles Griot no longer manufactures the 05-LIR-150 (and it's possible the one I have was acquired when they shed their remaining inventory). So, that question may be unanswerable. REO still has a 1,523 nm tube though. But their tubes tend to be strange by design.....
Initially, I assumed that the magnets had created a transverse Zeeman HeNe laser since that's what similar magnets may do with a random polarized 633 nm laser. However, the polarized single modes are separated by the longitudinal mode spacing of the laser tube - 438 MHz, so they are not Zeeman modes. Thus what the magnets appear to have done is simply allowed latent capabilities of this tube to excape and allow it to operate like a common 633 nm tube with adjacent modes being orthogonal. Magnet placement is critical though. If even a single magnet is moved too far, behavior reverts to either flipping at a fixed point during mode sweep, random flipping, or something even worse. It is not clear how sensitive this would be to the types of external fields to be expected in a laboratory environment including those from magnetic base optical table mounts! A Mu-Metal enclosure might be required.
### Converting an HP/Agilent 5517 or 5501B Laser to Dual Mode
Many/most HP/Agilent/Keysight two frequency Zeeman lasers eventually show up surplus on eBay and elsewhere often at very affordable prices usually due to the tube being end-of-life and not usable (at least for commercial applications). While "adjustments" can often be performed on the tube to render it acceptable for hobbyists, experimenters, and researchers as a two frequency Zeeman laser, it could also be converted to a conventional two mode stabilized laser. There are two possibilities:
1. The laser tube still has decent power and can be run stably:
1. If two modes are wanted, then it's done. ;-) There are two modes at the output - they are just very close together in optical frequency separated by the split or REF frequency.
2. If that's a problem, by changing the sign of the error signal and modifying the REF ON signal as described below, the two modes can be locked separated by the longitudinal mode spacing of the laser tube of around 1.8 or 1.475 GHz depending on tube type.
3. If a single mode is required, then it's as simple as adding a linear polarizer at the output to block one of them. HP/Agilent/Keysight lasers make excellent optical frequency/wavelength references.
However, "decent power" for these lasers is never very high and for surplus affordable ones, likely to be less than 300 µW TOTAL from both modes when locked.
2. The laser tube is junk - the power is too low or it won't start, stay lit, or sputters even if the operating current is increased slightly: Then it's possible to replace the fancy Zeeman tube assembly with a conventional random polarized HeNe laser tube that can be stabilized on two longitudinal modes using an external heater.
The general requirements are as follows:
* Red (633 nm) HeNe laser tube: Approximately 6 to 9 inches in total length such that a maximum of two longitudinal modes can oscillate when they straddle the neon gain curve. It must also be TEM00, random polarized, and a non-flipper. If the tube will run with an operating current of 3.5 mA, the existing HeNe laser power supply brick may be used. For a different current, a few can have the current adjusted via the trim-pot on the laser's Connector PCB (must have a 3-wire power cable) or the current can be changed by hacking them internally (most VMI PS 217, 373 and others).
* Heater for cavity length control: This can be a thin film (Kapton/polyamide) type or bifilar wound with magnet wire to achieve a cold resistance of between 8 and 16 ohms. It must have a positive temperature coefficient of resistance similar to copper.
* Lack of reference signal: Because these are not Zeeman lasers, there will never be a REF signal detected by the internal optical receiver and the controller would abort and retry when it is supposed to go into the locked state. Therefore, the "REF ON" jumper (J2) must be moved from "NORM" to the "LO" position (second from the right, low is the asserted condition, contrary to what's in the manual). This alone is usually sufficient but sometimes REF ON will need to be actively driven to the LO state only after the laser has reached operating temperature because the controller may get confused and attempt to lock before then.
The tube/heater assembly must be mounted and aligned with the beam expander (if it is to be used) with its polarization axes oriented horizontal and vertical.
Note that even if the original HP/Agilent/Keysight tube is still usable, it CANNOT generally be locked in a two mode laser by itself even if the glass tube is extracted intact. The polarization of these tends to be very unstable without a magnet. However, it could lock as a two mode laser whlie inside the magnet as described above.
Additional details are left as an exercise for the laser hacker. :)

Two-Frequency HeNe Lasers based on Zeeman Splitting

  1.3  mW      1.3 MHz  
  0.9  mW      1.5 MHz   1.6 MHz  
  0.75 mW      1.6 MHz   2.0 MHz  
  0.6  mW      1.7 MHz   2.2 MHz  
  0.5  mW      1.9 MHz   2.4 MHz  
  0.4  mW      2.2 MHz  

The listed Output Power is directly from the tube after appropriate mirror misalignment. The output power of the laser would be about 30 percent lower due to the beam expander, waveplate, and beam sampler losses. The Beat Frequency is the maximum value measured during mode sweep, which generally occurs close to where the laser would lock. So, the tube that had an output with optimal mirror alignment that was lower, produced a higher output power for any given beat frequency. This is the tube I shall use to build my SG-5517B laser. :)
Here are some measurements of output power versus split frequency made by simply turning the screw:
Split Frequency Output Power

    1.68 MHz         685 µW  
    1.76 MHz         600 µW  
    1.84 MHz         500 µW  
    2.01 MHz         400 µW  
    2.12 MHz         300 µW  
    2.30 MHz         250 µW  
    2.50 MHz         150 µW  
    2.60 MHz         100 µW  
Output Power (no magnet)       1.32 mW    1.38 mW  
Output Power (with magnet)     1.38 mW    1.47 mW  
Beat Frequency (with magnet)   1.26 MHz   1.58 MHz  

Without a magnetic field, there is of course no beat frequency. With the tube's active discharge centered within the 5517 magnet, the beat frequency is present for perhaps 50 percent of the mode sweep cycle. both the output power and beat frequency are a minimum around the center of this region. This is where the laser should be when it's locked - centered on the Zeeman-split neon gain curve, but differs from the behavior of the normal 5517 laser tube, where the locked position is with minimum output power and_maximum_ beat frequency. It's also interesting that the output power is more than 6 percent higher in the axial magnetic field. With a minimum output power of over 1.3 mW, this tube should produce more than 1 mW once the optics are installed.
The increased power may be related to both the likely difference in gas-fill isotope ratio and thus shape of the neon gain curve, as well as the profile of the intracavity mode volume, with the long radius hemispherical resonator configuration of this tube, compared to a nearly pure hemispherical resonator in the genuine HP/Agilent tube. Why this might occur is shown inComparison of Normal and Zeemon Modes in a Short HeNe Laser. The total output power in each plot is the sum of the red (F1) and blue (F2) modes. For the particular combination of cavity length and neon gain curve depicted in the diagram, the total output power with a magnetic field is higher than without a magnetic field. Of course, other things affect actual output power to even with this configuration, the difference would not likely be as dramatic. The lasing modes from the split gain curves are offset from the normal longitudinal mode position - one higher and the other lower. The difference between them results in the Zeeman beat frequency. However, the extent of the shift is at most a few MHz, much smaller than how it is depicted here.
I installed the tube in the magnet/optics assembly from a 5517B. The output power was now between 0.9 mW and 1 mW.
What I expected to happen when this tube was that it would lock normally but with perhaps a fuzzy MEAS signal due to rogue modes. However, this was not the case. In fact, it refused to lock at all within a reasonable time and when it finally did, the lock position wasn't at the center of the Zeeman-split gain curve, but rather near one end of the range over which there was any beat frequency, with an output power of around 925 µW. The lasing line location was inferred based on the beat frequency of around 1.46 MHz when locked. (See the chart, above.) At this lock position, the MEAS signal has some modest amount of fuzz likely due to rogue modes when the position of the mirror (my remote "tool") was changing. But the 5508A Measurement Display was happy enough with it and didn't generate any errors. By fiddling with the waveplates, it was possible to achieve a stable lock near the minimum of the beat frequency range, presumably also near the center of the Zeeman-split neon gain curve. However, at this location, any change in mirror position resulted in gargantuan amounts of fuzz with an almost unrecognizable MEAS signal and instant "SL Error" from the 5508A. My home-built measurement display was also hopelessly confused losing huge numbers of counts with any position change. As far as I can tell, there are no orientations of the waveplates that results in a totally clean MEAS signal when the remote mirror is moving though it is quite clean over much of the range when stationary.
The inability to lock at the correct location on the Zeeman-split neon gain curve must mean that the rogue mode amplitudes are so large that they overwhelm the difference of the F1 and F2 modes that should be driving the error amplifier/heater. Even when the lasing mode was nearly stationary at what should have been the correct location, it would eventually drift away from it with the beat frequency increasing until it disappeared. For this reason among others, I don't believe it's a problem with the thermal response of the heater/tube combination but rather based in the fundamental nature of this tube's mode characteristics. My next experiment will be to monitor the output on a Scanning Fabry-Perot Interferometer (SFPI) to actually look at the modes. I won't be able to see the individual F1 and F2 modes since they differ in frequency by such a small amount (less than 1.5 MHz) but should see them as one peak, along with a pair of peaks due to the rogue modes, all spaced around 1.1 GHz apart - the FSR of the tube. With a short tube such as this, there would be at most 2 modes lasing at any given time if there were no magnetic field. As the amplitude of one increases, the amplitude of the other decreases. But with the Zeeman-split neon gain curve, there should be at least 3 modes, and the amplitude of all of them will likely be quite large simultaneously.
I actually looked at the mode structure of both of the last two rebuilt lasers on a Spectra-Physics model 470 SFPI. (The first rebuilt laser one using the 5501A magnet assembly was no longer intact when I got around to doing these tests.) For the adjustable 5517 laser (tube #2) set 5517A mode (minimum REF frequency, maximum power), the mode structure looked similar to that of a normal healthy 5517C. (I don't expect the mode structure to differ by HP/Agilent laser model.) There were at most two modes present at almost all times and they were fairly clean, but there were small blips present on either side in addition to the main mode after the laser had locked. What the SFPI wasn't able to show was whether the split Zeeman mode consists of independent F1 and F2 components,
However, for the high power tube installed in a 5517B magnet (tube #3), the display was....totally confusing. This was in part due to the 2 GHz FSR of the SFPI, which results in aliasing of any modes spanning more than 2 GHz. But when aligned with the SFPI very carefully such that the FSR doubles to 4 GHz, what was happening became obvious: When one mode was at its peak - presumably centered on the Zeeman-split neon gain curve - there were modes on either side of it with greater total power. Since these would be on the opposite slopes of the neon gain curve, the feedback error signal from them would have the opposite polarity compared to the main modes, pushing the lock point away from the center. After many false starts, the laser did finally lock, but with 3 modes present with relative amplitudes of approximately 15, 100, and 70 were 100 was the F1/F2 or Zeeman mode - a rather skewed arrangement to be in a stable configuration! But although it might take 15 minutes to lock from a cold start, this is repeatable.
Such weirdness is much more interesting and entertaining than simply having a higher power two-frequency laser, though perhaps not particularly useful!
Tube #3: Spectra-Physics 007:
Next, I wanted to check out the performance of a Spectra-Physics 007 tube (same as the Melles Griot 05-LHR-007). These have about the shortest cavity of any modern commercial HeNe laser tube, with a distance between mirrors of only about 110 mm for an FSR of 1.36 GHz. This is even shorter than the "Long" tube 5517s and 5501B (126 to 132.5 mm) and close to that of the "Short tube 5517s (101.6 mm). Based on testing with a Scanning Fabry-Perot Interferometer (SFPI) with a typical 5517 magnetic field, the output should be pure two-frequency when locked even though it may not have a fancy isotopically pure gas-fill. The predicted split/REF frequency should be about 1.85 MHz, near the top of the range for the 5517A (1.5 to 2.0 MHz), and nearly up to the 5517B (1.9 to 2.4 MHz). The spec'd output power of these tubes is only 0.4 mW, but they typically do 0.7 to 1.0 mW when new, which should result in decent output power for these Zeeman laser experiments. I've selected one labeled 0.8 mW. By fiddling with mirror aligment (and thus cavity loss), it should be very easy to push it into the range of the 5517B, and probably the 5517C. Achieving useful 5517D performance may still be a challenge though.
Well that was the theory. Winding the heater (approximately 10 ohms), adding a lens to obtain a decent size beam after the HP beam expander, and installing the tube in a 5517 magnet and aligning the tube were no problem. A beat frequency signal was present for most of the the mode sweep cycle, though it is very fuzzy for much of it and kind of fades away, getting even fuzzier before disappearing rather than ceasing abruptly. One initial hypothesis was that since the gas fill is likely not isotopically pure, the gain curve is quite spread out and with the modest magnetic field, allows for two split modes to coexist over a large portion of the mode sweep. But since their split frequencies are not the same, the resulting interaction results in a fuzzy signal. Or something. :)
The laser locks reliably with a REF frequency of between 1.5 and 1.7 MHz. This is a bit lower than I had predicted, but the mirror reflectivity for the very short SP-007 tube may be slightly higher than 0.99, the value I had used in calculating it. Using 0.991 results in a predicted REF of 1.63 MHz, smack in the middle. However, no amount of fiddling with the waveplates results in a clean REF or MEAS signal. But this didn't appear to be due to rogue modes - when in motion, though still not clean, the behavior of the MEAS signal is as expected. One issue may be some sort of ripple a few hundred kHz MHz that is present even when there is no actual Zeeman beat frequency, possibly due to plasma oscillation. However, adding an additional 30K ohms of ballast near the anode and/or adjusting laser tube current have only a small effect - it never goes away. I've tried an adjustable HP-compatible Laser Drive 111-Adj-1, a Melles Griot 05-LPM-379, and a modified (adjustable) Aerotech LS2 (linear) HeNe power supply. As far as I can tell, the additional ballast made absolutely no difference. And this tube, which can normally run down below 3 mA, just barely stays lit at 3.5 mA - touching the anode wire makes it flicker. It's also not possible to obtain totally orthogonal F1 and F2 signals, though they aren't as bad as I first thought only monitoring the test point on the 10780C optical receiver, whose output is a highly non-linear function of the signal amplitude. Using a Thorlabs DET110 (biased photodiode), the crosstalk was found to be less than 5 percent and it's quite possible that more careful adjustments of the waveplates would reduce it further. But the several hundred kHz amplitude ripple is always present at about 10 percent of the total output power, so that may be the main problem. Aside from these anomalies, it behaves the same as an HP laser! :)
It seems that the SP-007 tube (or this sample at least) is very sensitive to current and the value of the ballast resistance. (This might be worse inside the magnet.) With the added ballast moved within an inch of the tube, it would stay lit at 3.0 mA and the amplitude of the oscillation was somewhat lower. So, I then proceeded to determine the optimal ballast based on what resistance value allowed the tube to stay lit at the lowest current. This turned out to be just about 75K ohms, with which it will stay lit almost down to 2.5 mA. Funny about that value. :) Using this ballast with the adjustable linear power supply results in decent performance at up to nearly 3.5 mA. The REF signal is clean and the MEAS signal is clean enough during motion that I would not normally give it a second glance in my usual testing of these lasers, though F1/F2 orthogonality is still not up to HP/Agilent standards with a minimum of about 5 percent crosstalk - the ratio of signal amplitude with a polarizer at 45 degrees compared to 0 or 180 degrees is only about 20:1. At 3.5 mA using the standard HP (VMI) non-adjustable HeNe laser power supply, there may be a bit more fuzz in REF and MEAS than with the optimal current but it's not worth dedicating an adjustable power supply for these tests. The laser locks normally and works without errors using both the HP-5508A and SG-MD1 Measurement Displays. So, the only remaining functional issue is the poor F1/F2 orthogonality. Fiddling with all 4 of the waveplate adjustments is unable to reduce it further. However, I can't rule out the possibility that this particular waveplate asssembly is damaged in some way. That's unlikely but not totally out of the question. But as they say: "It's close enough for Government work", especially given that this is only a proof of concept setup anyhow. It won't be used in a Fab producing nth generation CPUs. :) In addition, I've found somewhat similar behavior when installing a normal 5517B tube in a 5501B laser. The F1/F2 orientation of these tubes differs by 90 degrees but simply rotating the HWP - what would be the expected modification - does not work well. Even with extensive fiddling, the original waveplate assembly is unable to produce decent orthogonality. But a waveplate assembly from a 5501B laser requires only minor adjustments to produce excellent orthogonality even though they should have identical components. So, there is likely something I still don't understand about all this - as hard as that may be to believe! :-)
The SP-007 tube is currently installed in a 5517A magnet with a measured internal magnetic field of 260 G. With the temperature set-point adjusted with a multiplication factor of 1.34, lock is achieved in around 6 minutes and never lost thereafter. The heater voltage starts at about 6.0 V and declines to around 5 V after an hour. REF is approximately 1.1 MHz, which is consistent with an OC reflectivity of 0.991, quite possible for the SP-007. The output power is around 480 µW and the mode orthogonality is better than I had expected - at least 100:1 - which is quite respectable. But that oscillation (or something similar) shows up when there is no Zeeman beat. Using a low ripple VMI PS 373 power supply, the waveform is fairly clean, with a frequency betweem 1.8 and 2.0 MHz, decreasing as the tube temperature increases by about 0.02 MHz/mode sweep cycle. On an adjustable power supply, it's clear that the frequency is a strong function of current and changes instantly when current is varied. The good news is that the p-p amplitude of the oscillation is quite low - well under 1 percent of the total optical power and dwarfed by the Zeeman signal when a polarizer is present. It's simply showing up because the sensitivity of the 10780C optical receiver.
I have seen similar behavior with an HP-5517D laser tube that had been regased as an experiment by a major laser company. When reinstalled in the same magnet with the original ballast, oscillations are present during the first part of warmup, but they go away or became so small as to not be detectable by the 10780C optical receiver long before the temperature set-point is reached. And this seems to be inherent in the use of other short tubes, even brand new ones. (I can't provide specific models due to their intended use in commercial systems, but let's just say one type is almost identical to the -007.) Current and ballast have only minimal effect and it's not possible to eliminate the oscillation entirely. The cause is still a mystery.
Additional tests were done with an SP-007 outputting over 800 µW. (This may be the same sample as above.)
The tube was mounted in a cut-down 1-1/4 inch diameter aluminum cylinder and is fully enclosed except for six ~1/4 inch holes equally spaced around perimeter near center and loose fitting anode and cathode/heater/sensor wire holes. If fully sealed, the stability is very sensitive to operating current.
So as to avoid having to wind the heater, this uses a 16 ohm Minco "Thermofoil" Kapton polyamide heater that is 2 x 3 inches wrapped with the long side around the tube. A 8.5 PTC magnet wire temperature sensor is used with a Type I Control PCB (A3) that has been modified to use a separate sensor. (More on this below.) It locks in around 6 minutes.
By monitoring with an SFPI and tweaking the magnetic field with shims and permanent magnets, the roque mode limit after locking was determined to be approximately 400 gauss. That's the point where a second mode just appears. Other fields were also tried:
* 310 guass: Locked split frequency of ~1.22 MHz. Pure SLM.
* 400 gauss: Locked split frequency of ~1.44 MHz. Pure SLM.
* 450 gauss: Locked split frequency of ~1.65 MHz. Weak rogue mode when locked (10 to 20 percent) but still locks reliably).
* 500 gauss: Split frequency peaks at slightly above 1.70 MHz but will not lock and/or will lose lock. Large rogue modes.
The locked output power at the laser aperture (with feedback beam sampler and beam expander) is approximately 700 µW. The raw output from the tube is around 850 µW.
The magnetic field in all cases was measured centered in the interior of the magnet. However, there can be serious variation near ends, which may explain why the split frequency isn't linear with field.
The operating current was around 3 mA, which is the lower limit of supply, with 10K ohm ballasts close to anode and cathode, and 75K ohm main ballast. There is still amplitude ripple at around 2.3 MHz. The dropout current increases by around 0.4 mA due to the capacitance of the aluminum cylinder, and slightly from the magnetic field. In open air with no magnet, it may be lower than 2.0 mA.
**Tube #4: Melles Griot 05-LHR-640:**Another possible candidate for a replacement tube is the Melles Griot 05-LHR-640. It is a bit longer than the SP-007 or 05-LHR-007 with a 1.272 GHz FSR, but would probably also work. And although the spec'd output power is only slightly higher at 0.5 mW, the output power of these tubes tends to be much greater - over 1.2 mW for some samples. However, the optimal operating current is 4.5 mA and even new ones may not stay lit at the HP/Agilent default of 3.5 mA, so their use would require replacing the HeNe laser power supply. The SP-007s are spec'd at 3.2 mA, but are at least not terribly unhappy at 3.5 mA. Experiments with the 05-LHR-640 may be performed in the future.
But none of these tubes can reach the 5517D spec for REF and maintain high output power. Even the 5517C specs are marginal. Misalignment is still probably not as effective at increasing REF as a lower OC reflectivity. What may be needed is a tube physically similar to the SP-007 with an OC reflectivity of around 0.98, if it has a decently long life expectancy. :)
Finally, instead of winding the heater, a thin-film Kapton stick-on heater can be used if one can be found with a reasonable resistance, which should be between 10 and 20 ohms. However, many/most of these use a heater conductor with a near zero temperature coefficient of resistance, so the voltage drop cannot be used by the HP/Agilent control PCB to determine when the tube has reached operating temperature. The remedy is to create a separate positive temperature coefficient sensor that substitutes for the heater resistance as far as the controller is concerned. This sensor can be an appropriate length of fine magnet wire smooshed (technical term!) into a small space and secured to the tube. My solution used 16 feet of #36 AWG magnet wire bifilar-wound on a 1 inch form and then folded flat so that it wraps around the tube 180 degrees and takes up less than 1/4 inch of space. A piece of bicycle inner tube or tape secures it to the tube over the heater. A single cut on the "lab rat" A3 control PCB in my test 5517/5501B laser isolates the normal feedback path from the tube heater, which is then substituted by the custom sensor between ground and a 160 ohm resistor to +5 VDC with the centertap for the temperature sense signal. The actual heater can be almost anything with a suitable resistance. A 2x3 inch 16 ohm (constant) Minco Kapton heater was used for these tests based on availability. Since the thermal coupling is not as tight with this scheme, the set-point parameter of 1.285 is probably not quite optimal. That can be determined experimentally by fine tuning it so that the heater voltage at thermal equilibrium from a cold start ends up at around 7 V for the 16 ohm heater, 5 V for an 8 ohm heater.
Summary of changes to the Type I Control PCB (A3):
* Cut trace bewteen via and R21 (1K) going to U14. (Top of PCB goes under U15.)
* Add 3 pin jumper block (JB1) near TP11 and 2 pin header (HDR1) for temperature sensor next to it.
* Connect TP11 and its trace to left post of JB1.
* Connect R21 to center pin of JB1.
* Connect right post of JB1 to left post of HDR1 and one end of 160 ohm resistor.
* Connect other end of 160 ohm resistor to +5V TP.
* Connect right post of HDR1 to GND.
Put the Jumper between the left and middle posts of JB1 for normal operation; between the middle and right posts for use with temperature sensor.
Further tests of two samples of an SP-007 were done with Minco heater and separate temperature sensor (though this shouldn't affect the behavior), 10K ohm anode anode and cathode ballast (in addition to HP 100K ohm ballast). This was installed in a ~1.25 inch diameter aluminum cylinder cut to length with HeNe end-caps milled to accomodate anode and cathode ballast resistors and wiring. The magnet had a field strength of around 325 G.
* 0.85 mW max with no magnet: 0.725 mW locked, REF of 1.2 MHz.
* 0.65 mW max with no magnet: 0.450 mW locked, REF of 1.48 MHz.
These were set up with the normal temperature set-point factor of 1.285 times the sensor voltage from a cold start and lock at around 7.5 V. Since the tube voltage - and thus power dissipation - of the SP-007 is lower than than that of HP/Agilent tubes, that can be reduced somewhat. There are no rogue modes confirmed using SFPI with some headroom available to boost REF by at least another 10 percent. The lower power tube is probably higher mileage and much more sensitive to operating current. With the cylinder almost entirely sealed, there could be a runaway condition whereby the temperature continues to increase (and heater voltage decreases) due to internal dissipation alone. Some vent holes may be required.
One other change that may be required in order for a 5517 or 5501B to lock using a tube with a power of more than 1 mW is to replace R17 (316K) with a trim-pot so that its value can be reduced. At somewhat greater than 1 mW, the photodiode op-amp (U11D) may saturate and then the laser will refuse to lock or lose lock. R17 is next to the blue temperature set-point trim-pot, R16.
### Modifying an HP/Agilent Laser for Variable REF Frequency
A typical metrology application will have a specification for the minimum and maximum acceptable REF frequency of a two-frequency Zeeman HeNe laser. The minimum determines the maximum stage velocity in one direction while the maximum is limited by processing electronics. However, For testing purposes where the actual REF frequency of the laser is critical, it's annoying to have to swap lasers among 5517A/B/C/Ds. This became an issue in developing firmware for our Micro Measurement Display (µMD1). (See the section:Micro Measurement Display 1 (µMD1). Certain aspects of performance - in particular the sub-count interpolation using phase estimation - could be significantly affected by the actual REF frequency. Initially, piles of tin can shunt strips and external magnets were added to reduce the effective field, and thus REF frequency. But this was quite unwieldy, especially for a significant reduction. And the Zeeman magnet was slowly but surely losing some of its strength even after the appendages were removed.
Thus, being able to change REF at will without these drawbacks became highly desirable. Using an electromagnet to generate the Zeeman field is simply not viable without a superconducting coil as the required field strength is too great - up to several hundred gauss. Any copper coil would quickly go up in a cloud of smoke. And, no, water cooling was really not an option. :)
However, an electromagnet wound on top of a permanent magnet could be used to buck or boost its field. If the permanent magnet's field was 250 G, then *only* +/-250 G would need to be provided by the electromagnet. That's 25 percent of the power to null out the field entirely or boost it to the maximum required field of 500 G. And in most cases, the required change would be a lot lower. This is something that may be done in the future. However, to be able to do this in situ - inside a laser - may run up against the space required for the coil. There isn't much distance between the magnet and aluminum surround - or Control PCB even if that were cut away. Calculations show that to keep power to a reasonable 10 W at 250 G using copper magnet wire would require a cross sectional area of around 1.8 square inches, or a ~0.5 inch increase in radius. (The area is independent of wire size for a given power and field.) That just won't fit outside the permanent magnet.
Fixed 1 MHz to 3 MHz Split Frequency Laser
But for these experiments, the solution of choice was to be fully mechanical. My first thought was to insert soft iron shunt strips between the magnet and tube that would shield or bypass a portion of the permanent magnet's field. But some tests with tin can stock showed that it would be difficult to achieve enough of a change (3:1!) to be worthwhile. In addition, this approach would still present a risk of permanent demagnetization.
So the mounts for the tube and magnet were modified to allow the entire magnet to be moved axially with respect to the tube. A naked tube (don't ask!) was selected that had decent output power to use for this purpose. (Removing the bare glass tube from the potted magnet assembly is not something one discusses in polite company and requires several hours, so there are very few of these available. And even fewer that are in usable condition.) I would have liked to have the REF frequency range extend from that of the 5517A, 5501A/B, and N1211A (below 1.5 MHz REF to that of the 5517D (up to 4 MHz REF). But the only bare tube I had available with decent output power was from a 5517C. Sometimes these can be boosted to a 5517D REF with a more powerful magnetic field, but a test showed that not to be possible for this one without the creation of rogue modes. It's not worth the effort to extract a proper 5517D tube so this will have to do for now. The tube assembly frame from a 5517B was modified to permit the Alnico magnet itself to slide over a span of about 2 inches. This required removing and remounting the beam expander on spacers and and the waveplates on the aluminum surround. A 5517 magnet was charged to over 500 gauss and then had a socket for a rod with a handle attached to it with not-melt glue. The rod extends through the Connector PCB and Backplate of the laser. Only a single diode had to be relocated for the bypass. Now, the REF frequency can be easily adjusted from outside the laser. See HP-5517 Laser Modified for Variable REF Frequency. For maximum REF, the rod pulled all the way out placing the magnet in approximately the normal position with its coverage coincident with the tube's discharge. For lowest REF, it's pushed all the way in so that only about half of the discharge is covered by the magnet. I should label it "Reactor Control Rod". ;-) The magnet field strength had to be reduced slightly to avoid rogue modes at maximum REF, resulting in a usable range of about 1 to 3 MHz. A Scanning Fabry-Perot Interferometer (SFPI) was used to confirm that the laser is pure single mode (no rogue modes) even at maximum REF, though probably just barely. Unfortunately, REF of this 5517C tube could not be boosted into the 5517D range. Since µMD1 has a built in REF frequency readout, setting the laser to any REF within this range is quite trivial. The laser does not usually lose lock in the process, though locking may not be reliable initially at maximum REF.
Note that stock HP/Agilent lasers never use an effective magnetic field as low as is the case here at minimum REF. While the laser appears to work fine and is happy, there could be long term stability issues attempting to do this in a critical application, though I do not know this with certainty. In addition, moving the magnet to adjust REF is not precisely equivalent to varying the magnetic field as the field distribution within the discharge changes and even reverses polarity beyond the end of the magnet. One unexpected result of this is that rather than the output power declining monotonically as the REF frequency increases as it does when the split gain curves are moved further apart, with this setup, the output power is greater by 10 to 15 percent at the minimum and maximum REF frequency than in between. A detailed theoretical analysis of the effect of these conditions on the lasing process is left as a trivial exercise for the reader. In other words, I have only a partial clue but it appears to work well enough in practice. ;-)
General Purpose Variable Split Frequency Test Bed
A couple years after this stunt, I built a jig with a sliding magnet so any bare "Long" HP/Agilent/Keysight glass HeNe laser tube could be installed in my "lab rat" test 5517 laser (or other 5517 or 5501B laser body) to provide a range from the normal position of the magnet (with its edge lined up with the anode-end of the bore discharge) down to a nearly a 0 gauss field (with the magnet way beyond the cathode-end discharge escape holes). See HP-5517 Laser with Full Range Adjustable Magnet for Variable REF Frequency. The "Long" tube is supported at both ends by a drilled out HeNe cylinder end-cap at the rear and some sort of PVC plumbing fitting at the front. A set of waveplates is part of the assembly so it will lock normally if the split modes are cooperative. :) But there is no beam expander since alignment with that would be too finicky - an external beam expander on an adjustable mount is available for that purpose. (Adapters will be required to innstall a "Short" tube but at the present time there are no plans to create them.) This rig enables a range of split frequency (REF) from the "rogue mode limit" at the high-end (if the magnet is sufficiently powerful) down to well below 100 kHz. A fine line can be seen on the far rod where the maximum locked split frequency occurs for this ~500 G magnet. However, the split frequency at that location is not the maximum possible for the tube. More below. There is also a smudged line where the magnet is in the optimal position, which would be way above the rogue mode limit. The 5508A display tracks down to a REF below 100 kHz, but is eventually limited by the frequency response of the laser's internal REF receiver and the MEAS 10780 optical receiver, and possibly a lower limit in the firmware of the 5508A. The raw signals remain clean well below this. Operating at split frequencies less than 100 kHz is possible with HP/Agilent tubes due to their very small mirror asymmetry. Typical barcode scanner tubes would lose the beat frequency well above this range. Of course, the maximum stage slew rate at 100 kHz in the direction that decreases MEAS is vitually nill. :)
However, to obtain the maximum split frequency, the magnetic field must be trimmed so the rogue mode limit occurs just above when the magnet is in the normal (optimal) position relative to the tube - where it lines up with the anode and cathode discharge escape holes. This is because the field distribution from a cylinder magnet is not uniform and in fact reverses polarity beyond the ends of the cylinder as shown inField Along Central Axis of Ideal Magnet used in HP/Agilent Laser, and more generally for other size magnets inAxial Magnetic Field Distribution On-Axis for Cylindrical Permanent Magnets with Various Length (l) to Diameter (d) Ratios. What this means is that as the magnet is moved away from the optimal position, parts of the bore see the reverse polarity field and thus the split neon gain curves in those regions shift in the opposite direction. When the "positive" and "negative" portions are combined, the net effect is for each of the split gain curves to be wider with a smaller net shift, which reduces the mode pulling responsible for creating the split Zeeman lasing mode. And while waving my arms wildly, strange things happen. :) Specifically, there will be no position of the magnet where the maximum possible split frequency can be obtained in a stable locked manner - not even close. In an extreme case (possibly not with a standard HP/Agilent magnet though), there could be a null point where the two pairs of gain curves are shifted symmetrically and the split frequency goes to 0 Hz even though the tube is in a strong magnetic field. And beyond this point, the loop error term woudl reverse polarity resulting in an inability to lock as a 5517. It would then be necessary to reorient the waveplates or switch from 5517 to 5501B locking.
As a specific example, using the tube from a reasonably healthy 5517A or late model 5501B (which are similar), the maximum split frequency in this rig with a 500 G magnet is limited to around 1.4 MHz with the magnet located at that mark on the mounting rod. Closer in than that, lock is lost due to rogue modes confusing the feedback electronics as the field is increased as the rogue mode limit is exceeded. But if the same magnet has its field reduced to the rogue mode limit - somewhere around 425 G for this tube - locking occurs reliably at a split frequency above 2.2 MHz with the magnet in the optimal position. And it declines smoothly and monotonically as the magnet is moved down the track away from the optimal position, usually without losing lock along the way.
As to why anyone would care about any of this or want to replicate it is another matter. ;-)
### Converting an HP/Agilent Metrology Laser into a Basic Stabilized HeNe Laser
Literally thousands of 5517 and other HP/Agilent lasers are in existence and many of these turn up surplus, usually with bad tubes but good everything else including the HeNe laser power supply and control electronics. Since most applications don't require - or desire - a two-frequency laser, what about turning one of these into a conventional stabilized HeNe laser outputting a single mode? If the tube is good and locks normally, by far the easiest approach is to simply block one of the two orthogonal polarized frequency components (F1 or F2) with a polarizer or polarizing beam-splitter. Job done. :) For a reasonably healthy tube, the resulting optical frequency will likely be within 10 MHz or so of the published specifications for the laser. The disadvantages are that most of these lasers (at least the ones that are affordable) that still work at all have weak tubes so the output power will typically be 100 µW or less. And most have totally dead tubes, or tubes that might be put on life support requiring additional a different HeNe laser power supply or more.
However, the entire tube/magnet/optics assembly can be replaced with a common barcode scanner tube with the addition of a thin film "Kapton" or Bifilar wound (magnet wire) heater. There's ample room for a 9 or 10 inch tube that would produce an output power in a single mode of 0.5 to 1 mW - similar to that of most commercial stabilized HeNe lasers. For more power, a new tube can be purchased from a company like Melles Griot. For example, their 05-LHR-092 has "non-mode flip optics" and will "only" set you back somewhere between 400and400 and 400and1,000. :) But suitable tubes also appear quite frequently on eBay for 1/10th as much or less. Of course, eBay sellers will have no clue about "well behaved non-mode-flip optics, huh?", so you may have to buy a few before getting one that is suitable. Resell the rest. ;-) I also have tubes available.
In fact, there is no benefit to using the original HP/Agilent tube even if it is removed intact. Aside from the low output power even if the tube is healthy, my testing has shown that these tubes are extremely sensitive to stray magnetic fields and do not have well behaved mode sweep behavior under any conditions without the magnet, rendering them useless because it would not be possible to reliably stabilize the mode position. See the section: HP/Agilent 5517 Mode Behavior for more details.
In a nutshell, the general procedure to install a conventional tube is as follows:
1. Locate a suitable HeNe laser tube. One candidate is the Spectra-Physics 088, no longer manufactured but many are still kicking around removed from barcode scanners during preventive maintenance, not when they die, so they are very often in usable condition. These have a typical output power of over 1 mW thus producing around 0.5 mW in a single mode when dual mode stabilization is used. One benefit of an 088 is that a healthy one should run on the existing HeNe laser power supply at 3.5 mA. There is also an 088-2 that produces 2 to 3 mW. In fact, a version of the 088-2 was the tube used in the SP-117 stabilized laser. But the 088-2 requires a higher current power supply (4.5 to 5 mA).
2. Test the tube for well behaved longitudinal mode behavior and identify the polarization axes.
3. Wind the tube heater or obtain a thin film heater with a resistance of around 10 ohms. Wire the cathode/heater connector. When plugged into the laser, the top pin (purple wire) should go directly to the cathode and one terminal of the heater, while the bottom pin (red wire) goes to other terminal of the heater. (Note that any commercial heater must use a material with a positive temperature coefficient of resistivity for the HP/Agilent warmup circuitry to work properly. The copper wire used in a wound heater has this characteristic.)
4. Attach the anode wire and ballast resistor. For a tube using the original HeNe laser power supply (usually 3.5 mA), the original wire/connector and ballast resistor can be used.
5. Remove the existing tube/magnet/optics assembly. The easiest way to mount the new tube is using its feet with the addition of a set of 6 Nylon thumb-screws to secure and center the new tube. Of course, this will mean destroying a work of art so machining something suitable may be a less traumatic plan. :)
There is no need to use the beam expander unless a large beam is desired. And note that since the beam diameter of the typical HeNe laser tube is much smaller than that of the HP/Agilent tube, the output from the beam expander will also be smaller. It may also need to be adjusted for the lower divergence of a non-HP/Agilent tube.
6. The beam sampler (not part of the tube/magnet/optics assembly) is required to provide locking feedback. However, for the Zeeman laser, in addition to sampling the horizontal and vertical modes, it has a photodiode for generating the REF frequency output, which the controller also uses to know that locking has been successful. This must be disabled by moving the "REF" jumper on the Control PCB from the "NORM" to "LO" position (second from the right).
7. Install the new tube, aligning and centering it within the beam sampler, and aligning its polarization with the horizontal and vertical axes.
8. Perform the temperature set-point adjustment for the laser as described in the section: HP/Agilent 5517 Temperature Set-Point Adjustment.
Since the heater is external, it may take longer to lock and remain locked than the normal 4 to 5 minutes, but should end up being quite stable. However, the temperature set-point factor (1.285) may differ for optimal performance depending on ambient temperature.
For more information, particularly with respect to the heater construction, see the previous section.
### Axial Zeeman Experiments Using Variable Magnetic Field
Most of the tests involving HeNe Zeeman lasers described elsewhere in this chapter either use the original magnets from HP/Agilent lasers, or various configurations of permanent magnets, or various means like soft steel shunts or external magnets to modify the field of the original permanent magnet. However, being able to vary the magnetic field provides additional flexibility, and enables much lower fields to be used than are possible with the permanent magnet.
The equation for the field of an air-core solenoid is:
N * i
B = μ0 -------
L
where:
* B = the magnetic field inside the solenoid (T).
* μ0 is the magnetic constant or permeability of free space: 1.2566370614*10-6 H/m.
* N = number of turns.
* i is the current (A).
* L is the length (m).
HP-5517C HeNe Laser Tube Installed in Modified Tube Assembly with Electro-Magnet Solenoidshows the glass laser tube extracted from an HP-5517C laser inside the solenoid, which replaces the normal permanent magnet in a modified HP laser tube assembly. The length of the solenoid is 8.9 cm and the total number of turns of #24 AWG wire (~0.021" diameter, 25.67 ohms per thousand feet) was supposed to be 600 but may be a bit less due to winding "difficulties" :( :), so call it 575. Using these values results in a magnetic field of about 81 G/A. The gap for the Nylon tube mounting screws will result in a slight inhomogeneity in the field but that should have virtually no effect on behavior. The black cylindrical object at the output-end has the standard HP/Agilent Quarter-Wave and Half WavePlates (QWP and HWP) that convert the circularly polarized Zeeman modes to H and V linear polarization. A polarizer oriented at 45 degrees then combines these to generate a difference frequency signal using a Thorlabs DET110 back biased silicon photodiode (shown) or a Thorlabs DET55 amplified photodiode for better signal strength, with an oscilloscope and frequency counter.
Up to about 3 A can be passed through the solenoid for a few seconds without it getting excessively hot. This results in a magnetic field of approximately 243 Gauss, still far from the possible field of an Alnico magnet, which could be as high as 1.5 k Gauss. However, as will be seen below, it is probably under 500 G for most HP/Agilent lasers. 6 A can probably be applied for long enough to capture multiple complete mode sweep cycles if the tube's internal heater is powered to speed up mode sweep.
HP/Agilent HeNe laser tube:
Using a genuine 5517C laser tube, there is a wide variation in beat frequency during mode sweep that is usually opposite of that with the much stronger field where only a small portion of the gain curves overlap. And that variation may be 2:1 or more even at the highest field used with this rig so far, which is much larger as well. Except for one small range of low field, the minimum beat frequency occurs where the split mode is centered on the split gain curve rather than the other way around with the stronger field. The beat waveform is reasaonably sinusoidal under most conditions, especially at higher fields.
Approximate Beat
Magnetic Frequency
Current Field Min Max Additional Comments

0.1 A 8 G 0.058 MHz 0.135 MHz
0.17 A 14 G 0.037 MHz 0.159 MHz
0.2 A 16 G 0.035 MHz 0.140 MHz Bimodal: 0.073 MHz, Dropout low
0.41 A 33 G 0.000 MHz 0.120 MHz Bimodal: 0.085 MHz
0.5 A 41 G 0.000 MHz 0.200 MHz
1.0 A 81 G 0.195 MHz 0.580 MHz
1.5 A 122 G 0.425 MHz 0.890 MHz
2.0 A 162 G 0.690 MHz 1.180 MHz
Note that above 0.5 A, the maximum frequency increases reasonably linearly with current. Except as noted, the beat frequency disappears for a portion of the mode sweep cycle at its maximum. Only around 0.2 A does it drop out at the low end.
There are also some other strange effects at low fields (current less than around 0.5 A) that may be due to the "lumpy" shape of the split gain curves:
* Even with no applied field, there may still be a beat frequency for a portion of the mode sweep cycle. This may be in part due to the 0.5 G of the Earth's magnetic field, but possibly also from residual magnetization of the Kovar feed-through posts for the cathode and heater.
* Up to about 0.17 A, the maximum beat frequency increases.
* Between 0.17 A and 0.41 A, the maximum beat frequency decreases.
* Above 0.41 A, the maximum beat frequency increases and continues to do so beyond at least 2.3 A, the limit of this setup at the present time.
* Over a small range of current, the beat frequency goes smoothly to less than 1 kHz, then to 0 Hz, though it's difficult to determine if it simply disappears or passes through low frequencies.
* And as noted, over an even smaller range of current, the beat disappears at the low extreme while it changes smoothly at the high end.
Thus, at very low fields, something peculiar is going on. I don't believe there are any stray magnetic fields near the setup that might be interacting or getting canceled out at low current. There is a loudspeaker and some strong magnets stuck to a cabinet about 4 feet away - and changing their position does have a very slight effect if the solenoid current is 0 A, but _any_current - even 0.01 A - quickly overwhelms anything they do. These effects may be unique to the HP tube design and not show up with a conventional tube with similar cavity length.
The next experiment was to install this rig in an actual HP laser with waveplates oriented for the 5517 and a controller that could be switched between 5501B or 5517 operation. It does lock with an acceptable F1/F2 mode balance, though somewhat reluctantly as it takes a minute or more longer than normal. The magnetic field can be varied over a wide range without losing lock, producing a REF from below 50 kHz to 500 kHz or more. Using a 10780C optical receiver and 5508A Measurement Display, behavior is normal over this range subject to the expected limitations - low frequency cutoff of the 10780C and the slew rate limit imposed by the REF frequency. However, there are definite peculiarities in this regime which is way below the magnetic field for normal operation:
* The lock point is not at or near either the minimum or maximum of the beat frequency during mode sweep but somewhere in between. It can sometimes find a stable lock point with the controller set for 5501B even though the tube is configured as a 5517. This would not occur with a normal 5517 tube. There may even be more than one location on the mode sweep where locking takes place. For example, with the same magnetic field, it may decide to lock with a difference frequency of 300 kHz or 500 kHz depending on its mood.
* The speed of locking is very slow indicating a low loop gain. Even changing the controller setting from 5517 to 5501B results in a very sluggish drift away from the original lock point, yet this basically inverts the sign of the error signal! At these small magnetic fields, the split gain curves may still be relatively flat and lumpy like those with no magnetic field found for this same tube inHP-5517C HeNe Laser Tube Mode Sweep Behavior. For the 5517C tube in its normal magnet, the one lock point is where the split gain curves intersect with a steep slope - the "X" with the red curve increasing.
Since the effective feedback gain is proportional to the difference between the components from the split gain curves, being relatively flat but lumpy would explain both the slow locking and the ability to lock at multiple locations.
And in fact, this did necessitate further testing. It becomes even stranger. The next experiment was to use a data acquisition system to capture the mode sweep during locking for comparison with a genuine unmodified 5517C. See HP-5517C HeNe Laser Tube Mode Sweep Versus Magnetic Field. The red curves are the horizontal (F1) polarization while the blue curves are the vertical (F2) polarization. The green is total output power. The regions over which a beat frequency is present are denoted as "Beat".
The top plot is how the mode sweep appears with the typical standard cylindrical permanent magnet. The next three also use a similar magnet, but with various methods employed to reduce its field. The remaining plots use my solenoid at various currents from about 2 A down to 0 A. The general appearance of the plots for other HP/Agilent lasers would be generally similar at each of the magnetic fields but the value at which they normally operate may differ. For example, the normal field for the 5501B and 5517A is around 250 g.
My initial impression after capturing the plots using the solenoid was that there's something really weird going on. Did I say that already? :) The normal plot and one with the 120 g field look remarkably similar one was shifted over so the "Xs" where the red and blue modes intersect lined up and red and blue were interchanged. But that turns out to be a conincidence. In fact, originally I did have them nicely aligned. The behavior just didn't make sense that way and it turned out to be wrong as there's one key difference: With the HP magnet, the beat only appears during the area of steep slope within the "X" where the modes cross with the red mode rising. With the much weaker solenoid fields, the beat appears everywhere else BUT there. (Though if it did appear within the X, it would be the maximum (which is consistent with the HP laser behavior.)
This now explains the peculiar locking behavior. When set for 5517, it attempts to find a place where the red and blue curves intersect with the red one increasing and there can also be multiple places where these conditions occur. In fact, if the controller is set for 5517, it will lock at either of two places over a range of magnetic fields from 5 to 120 gauss. If set for 5501B, it will attempt to lock at the Xs but fails because no beat frequency is present there. While locking feedback uses the same modes that are plotted here, even if a stable point is found, the REF signal must be present for it to consider itself locked. Without one, it keeps trying until by chance it happens to be near a ripple between the Xs when it enables feedback. If set for 5517 with the 120 g field, the gain of the error signal at the lock point (where both the red and blue curves are nearly horizontal) that it may never lock, or at best the stability will be poor.
My conclusion now is that because plots for intermediate field strengths were not originally made, it initially appeared as though the behavior was the exact opposite for high and low fields. For example, the general shape of the plots is nearly identical for the normal 5517C laser and the plot made at 40 gauss - simply shift one over and swap red and blue. However, the beat frequency was present in totally different locations! But with the complete set of plots, the continuous progression becomes apparent, though the underlying phenomena which result in the shape of the plots are subtly different for the high field and low field regimes:
* For the unmodified 5517C laser strong magnetic field plot, the Zeeman split neon gain curves are quite far apart - on the order of 900 MHz - such that they overlap only over a small span. That's where a single longitudinal (cavity) mode is split into Right Circularly Polarized (RCP) and Left Circularly Polarized (LCP) components resulting in the generation of a beat frequency only in the region where the red and blue curves intersect with nearly constant minimum output power, at the Xs. Mode competition results in linear slopes with maximum beat frequency at the intersection.
* For the field reduced plots, the neon gain curves are split apart by perhaps 400 to 800 MHz, so behavior is intermediate between that of the low field and normal fields. For the highest of the field reduced plots, the beat frequency is nearly constant during mode sweep. For the lower ones, it is a minimum when the split mode is centered.
* For the low field solenoid plots, the neon gain curves are split apart by a much much smaller amount - order of 60 to 350 MHz - so that they overlap for most of their width. Therefore, a beat frequency is generated over nearly the entire mode sweep. But where the red and blue curves intersect for those cases (and appear similar to the Xs for the strong field case) is actually with a pair of adjacent (unsplit) longitudinal modes. They are also RCP and LCP but separated by the FSR of the cavity, 1.18 GHz. The mode competition still results in nearly linear slopes and relatively constant power in that region but there is no beat at a frequency that will be detected as it's around 1.18 GHz. This also explains why that region increases in width as the field is made stronger. The beat frequency is a minimum at the intersection.
Now how's that for hand waving!? :) Well, I did cheat slightly. The "field reduced" plots use an intact 5517B laser with a combination of steel shims and external permanent magnets used to adjust the magnetic field. Thus (1) the tube characteristics may differ slightly compared to a 5517C and (2) the field may not be perfectly uniform, thus changing the behavior slightly in unknown and unpredictable ways. But this avoided requiring a 100 V 1 kW DC power supply and liquid nitrogen cooling for the electromagnetic solenoid in order to achieve field strengths approaching those of the 5517C laser. ;-)
But a quick test monitoring the output on a Scanning Fabry Perot Interferometer (SFPI, also known as a laser spectrum analyzer) during mode sweep confirms that the scenario above is indeed correct. During a small portion of the mode sweep cycle, a pair of modes are displayed, while everywhere else, only a single mode is present. The SFPI can't resolve the split of this mode to produce the beat frequency, but that is assumed to be present. The timing of when the pair of longitudinal modes (with a spacing of 1.18 GHz) appears matches quite closely with the "dead zone" where there is no beat, and the duration gets longer with increasing magnetic field just as the plots show. Setting everything up to be able to capture output power, F1/F2 modes, beat frequency, and the laser spectrum would have been quite a treat, but this should be sufficient for government work. ;-)
The bottom diagram in Normal and Zeeman-Split HeNe Laser Mode Power Curves shows the envelopes of the lasing mode power curves (or split neon gain curves above threshold) for the two polarizations for a nearly new 5517B. While the normal FWHM of the neon gain curve is generally assumed to be between 1.5 and 1.6 GHz, each of the split gain curves has less gain but something else happens when they are spread apart by a large amount: Mode competition appears to further reduce the Effective Gain Bandwidth (EGB). The diagram shows about 1.28 GHz for the EGB and this has been confirmed by testing other lasers. In the diagram, the total shift between the split lasing output power curves is about 0.9 GHz. Based on the value from the Zeeman split equation (total shift of 2.8 MHz/g), that requires around 321 g (Reference: "Gas Lasers", by Charles Geoffrey Blythe Garrett, McGraw-Hill advanced physics monograph, 1967). The field for a 5517C is on average somewhat higher than for a 5517B even for a new laser, but the diagrams are not necessarily totally to scale. Nonetheless, as shown in the plots, the actual values appear to be fairly close to these.
Here is more detail on the plots. Take with a large grain of optical glass at the present time only taking their quaalitative appearance seriously; the numbers may not be totally accurate but probably are within +/-10 percent. Where an HP permanent magnet was used, it had its field reduced with soft iron shims or small Alnico magnets.HP-5517C HeNe Laser Tube Installed in Modified Tube Assembly with Electro-Magnet Solenoid was used for the lower fields.
1. Normal Cylindrical Permanent Magnet - Approximately 350 Gauss: This is an unmodified 5517C laser (though probably not the one from which the tube was extracted for the solenoid plots, below). The beat frequency appears for about 20 percent of the mode sweep cycle with a maximum of 2.4 to 3.0 MHz (not measured) when the split lasing mode is centered between the split neon gain curves, which is also where the laser locks.
2. Field Reduced Permenant Magnet - Approximately 295 Gauss: This is actually a 5517B laser which had had its field adjusted to lock at around 2.0 MHz. At this field strength, the beat frequency is present for about 33 percent of the mode sweep cycle and is nearly constant. So this represents the transition point between the beat frequency being maximum at center and minimum at center.
3. Field Reduced Permenant Magnet - Approximately 240 Gauss: The 5517B with its field reduced to result in a locked beat frequency of about 1.6 MHz. At this field strength, the beat frequency is present for about 46 percent of the mode sweep cycle and the minimum beat frequency is where the split lasing mode is centered and locked.
4. Field Reduced Permenant Magnet - Approximately 190 Gauss: The 5517B with its field reduced to result in a locked beat frequency of about 1.2 MHz. At this field strength, the beat frequency is present for about 60 percent of the mode sweep cycle and the minimum beat frequency is where the split lasing mode is centered and locked.
5. Solenoid Electromagnet - Approximately 160 Gauss: Bare 5517 tube in solenoid electromagnet at around 2 A. At this field strength, the beat frequency is present for about 68 percent of the mode sweep cycle. The lock point is NOT in the center due to the nearly flat mode slope there, so it's off to the right side with a beat frequency of around 850 kHz.
6. Solenoid Electromagnet - Approximately 125 Gauss: Bare 5517 tube in solenoid electromagnet at around 1 A. At this field strength, the beat frequency is present for about 75 percent of the mode sweep cycle. There are two possible lock points - where the red mode intersects the blue one with a positive slope. One lock point was around 500 kHz.
7. Solenoid Electromagnet - Approximately 85 Gauss: Bare 5517 tube in solenoid electromagnet at around 0.66 A. At this field strength, the beat frequency is present for about 83 percent of the mode sweep cycle. There are two possible lock points - where the red mode intersects the blue one with a positive slope. One lock point was around 266 kHz.
8. Solenoid Electromagnet - Approximately 50 Gauss: Bare 5517 tube in solenoid electromagnet at around 0.33 A. At this field strength, the beat frequency is present for about 90 percent of the mode sweep cycle. There are two possible lock points - where the red mode intersects the blue one with a positive slope. One lock point was around 100 kHz. Note the glitches in the mode sweep plots which show up at this low field, likely due to tube asymmetries.
9. Solenoid Electromagnet - Approximately 32 Gauss: Bare 5517 in solenoid electromagnet at around 0.17 A. At this field strength, the beat frequency is present for about 93 percent of the mode sweep cycle. There are two possible lock points - where the red mode intersects the blue one with a positive slope. One lock point was around 50 kHz. Even more pronounced glitches show up in the mode sweep plots at this low field.
10. No Axial Magnetic Field: Bare 5517 tube in solenoid electromagnet at exactly 0.00 A. The only magnetic field would be due to that of the Earth and possibly a loudspeaker 3 feet away. :) There is no detectable beat during mode sweep, though a very low frequency would not be picked up by the HP 10780C optical receiver. The polarization behavior of most HP/Agilent tubes with no magnetic field is often quite random: With no polarizer in the beam, a display of the longitudinal modes will be stable. But with a polarizer, the amplitudes will be randomly flipping between them.
The value of 160 G for the electromagnetic solenoid is believed to be fairly accurate based both on its construction and actual gauss measurements using the device described in the section:Simple Gauss Meter for Measuring Zeeman Magnet Strength However, for all these magnets, the field is far from uniform, peaking in the center and becoming 0 at the ends. And on some, it's not even remotely symmetric and may be "lumpy". :) For the long HP/Agilent tubes (5501A/B, 5517A/B/C/D), the active discharge extends precisely to the ends of the magnet so it sees a wide variation in field strength. For these measurements, the maximum value was used. The amplitudes are also not necessarily at the same scale for all fields, and as noted, 3 different tubes were used. Use the plots primarily for their qualitative value! :-)
Originally, everything was referenced to what was believed to the magnetic field for a 5517E of 363g which was hand printed on the magnet. :) But this was contradicting both theory and data. Once measurements of the actual magnetic field inside a few HP magnets were made, it was clear that what that 363g referred to was probably the fringe field in the center on the outside of the magnet. This value was confirmed on the 5517E to be 363 g at the mid-point of the cylinder about 6 mm away from its surface. This would be a reasonable distance for a commercial probe, but mine can get as close as 1.5 mm. At that distance, the field is about 440 g. The interior field is almost always significantly greater, though can be quite a bit of variability from one magnet to the next. Using the field outside makes sense for manufacturing purposes since it can be measured even once the tube is installed. Based on my measurements of external field of several 5517C magnets and the internal field of one of them, the ratio is between 1.2 and 1.4 would result in a 5517C field of 362 g to 423 g or an average of 393 g. That the predicted value has come so close is actually quite amazing. ;) (See the section: HP/Agilent 5517 Laser Construction for the magnetic field measurements.)
But I'm actually quite satisfied with the results of this set of experiments. At first it seemed like the Universe was turned upside-down or inside-out (with the beat frequencies appearing in opposite places for the high and low field regimes) but now everything is consistent and it makes reasonably more or less if not perfect sense. :)
Short internal mirror HeNe laser tube
Now here's some data for a Melles Griot 05-LHR-006 tube in the same solenoid. The 05-LHR-006 has a cavity length of about 139 mm, only slightly longer than the HP tubes (127 mm), though the mirrors probably have higher reflectivity. This is also a very lively tube with an output power when warm of over 1.5 mW. A longer cavity, higher reflectivity, and higher power all will result in a decrease in beat frequency compared to the HP tube.
Approximate Beat
Magnetic Frequency
Current Field Min Max Additional Comments

0.0 A 0 G --- --- Instability but no beat
0.2 A 16 G 0.000 MHz 0.200 MHz Stable beat over most of most sweep
0.5 A 40 G --- --- Null point, no beat, only instablity
1.6 A 120 G --- 0.200 MHz Normal regime for HP/Agilent lasers
Somewhat above 120 G, the split frequency starts to increase monotonically with field strength, but obviously it's not linear at that point since almost 800 G would be required to get to 1.5 MHz. :)
What's striking about this is how consistent simply varying the current to the magnet can peak the beat around 0.2 A with 0 Hz on either side. However, the specific behavior varies significantly from one tube to the next. It is speculated that this is the type of Zeeman splitting that is caused by mirror birefringence (and not mode pulling), and what's actually described in many of the scholarly texts, which date from the 1960s when general access to even the relatively modest magnetic fields of Alnico magnets was more limited (though of course there were strong electromagnets).
### Sam's Full Range Variable Zeeman Electromagnet
An electromagnetic solenoid has been constructed capable of achieving the field strength required for testing_any_ HP/Agilent laser tube (Long or Short) without overheating too quickly. See HP/Agilent Test Assembly Providing Wide Range Variable Magnetic Field. It uses around 775 feet of #18 AWG magnet wire (over 3-1/2 POUNDS!) in a dozen or so layers wound on a N1211A magnet. After this photo was taken, additional turns were added to make up for the missing section on the right to improve uniformaty. But it's even uglier now. :( :) The magnet has an I.D. of around 1.65" which is slightly larger than that of most HP/Agilent magnets (1.5") so it will accommodate the extracted tubes from all HP/Agilent/Keysight lasers, as well as most other small tubes used for Zeeman experiments. The tube installed for the photo is an N1211A that retains its rear potting extending about 1" into the magnet. The optics mount also retains the ring at the front so the tube alignment is quite accurate, at least for this sample. A 1 mm N1211A beam collimator is shown for testing of "Long" HP/Agilent tubes. But it could be removed for use with Short or non-HP/Agilent tubes, or if this is installed in a laser. In that case, an external 6 mm HP beam expander on an adjustable mount replaces it, which is easier to align. The magnet itself is charged to around 280 G so that increasing and decreasing the field can be done depending on the polarity of the current. The maximum field the electromagnetic needs to produce is less than -180 G to 220 G for range of 100 to 500 G, requiring under 20 percent of the power if the full 500 G had to be produced by the electromagnet alone. And for most tubes, the rogue mode limit is well below 500 G so the actual power will be even lower and near-continuous operation should be possible. The coil covers around a 3.25" length of the magnet at its start (the portion normally exposed) but successive layers taper somewhat from the manual winding procedure, so the field will decline toward the ends. But in addition, this resulted in fewer larger diameter turns. I was originally targeting around 10 W to change the field by +/-250 G with ideal rectangular packing of the wire, but the final result is closer to 20 W. A room temperature superconductor would have remedied that. ;-)
The electromagnetic field does not affect the permanent magnet's permanent field strength. However, since the field of the permanent magnet is far from text-book in its profile and would not quite match that of the electromagnet solenoid even if it was, perfect cancellation is not possible near zero, so fields below 50 to 100 G or so are problematic. If adjusted for 0 G in one location, the field may be +/-25 G or +/-50 G somewhere else. Thus, Zeeman behavior at low fields is unpredictable. It might be possible to trim its field to get closer using a soft iron rod or small magnet from the inside. But HP and similar Zeeman metrology lasers never operate in the low field regime. For those experiments, I have my pure electromagnet solenoid. :-) Due to the cross sectional area of the copper, the coil, the overall diameter is around 3.5" and the coil will not fit inside an HP/Agilent laser body without modifications, requiring separating the shroud with the control PCB from the chassis and extending its two connectors with male to female headers.
However, should the magnet's permanent field need to be changed, discharging a capacitor through the same coil should be capable of adjusting it in-situ, and perhaps that can be used to make it more uniform someday. :) It will be interesting to see how much voltage and energy will be required. The device I normally use (shown in Sam's Magneto-Matic Dial-A-Field™ Alnico Magnet Charger.) was never optimized but built based on a few quick experiments.
Here is some certifiably high uncertainty not-fudged data:
|<------ Field (G) ------>|
Voltage (V) Current (A) -1" 0" +1" Average

 -12          -2.4         6   -46   -35     -25  
 -11          -2.2        32   -21    -8       1  
 -10          -2.0        58    12    15      28  
  -9          -1.8        73    35    37      48  
  -8          -1.6        94    60    56      70  
  -7          -1.4       125    81    77      94  
  -6          -1.2       144   112    95     117  
  -5          -1.0       161   135   116     137  
  -4          -0.8       183   162   142     162  
  -3          -0.6       210   193   160     188  
  -2          -0.4       228   220   180     209  
  -1          -0.2       253   250   200     234  
   0           0.0       278   275   252     268  
   1           0.2       300   306   278     295  
   2           0.4       323   334   285     314  
   3           0.6       347   360   298     335  
   4           0.8       367   385   323     358  
   5           1.0       386   412   356     385  
   6           1.2       412   430   362     401  
   7           1.4       435   470   390     432  
   8           1.6       462   493   410     455  
   9           1.8       480   515   440     478  
  10           2.0       491   540   470     500  
  11           2.2       517   566   478     520  
  12           2.4       540   593   502     545  

Transverse Zeeman Stabilized HeNe Lasers

Intensity Stabilized HeNe Laser