Biomechanical analysis of three different types of fixators for anterior cruciate ligament reconstruction via finite element method: a patient-specific study (original) (raw)
Basu B, Katti DS, Kumar A (2010) Advanced biomaterials: fundamentals, processing, and applications. Technology & Engineering. John Wiley & Sons, Hoboken, New Jersey
Cinque ME, Chahla J, Moatshe G, DePhillipo NN, Kennedy NI, Godin JA, LaPrade RF (2017) Outcomes and complication rates after primary anterior cruciate ligament reconstruction are similar in younger and older patients. Orthop J Sports Med 5:2325967117729659. https://doi.org/10.1177/2325967117729659 ArticlePubMedPubMed Central Google Scholar
Samitier G, Marcano AI, Alentorn-Geli E, Cugat R, Farmer KW, Moser MW (2015) Failure of anterior cruciate ligament reconstruction. Arch Bone Jt Surg 3:220–240 PubMedPubMed Central Google Scholar
Studler U, White LM, Naraghi AM, Tomlinson G, Kunz M, Kahn G, Marks P (2010) Anterior cruciate ligament reconstruction by using bioabsorbable femoral cross pins: MR imaging findings at follow-up and comparison with clinical findings. Radiology 255:108–116. https://doi.org/10.1148/radiol.09091119 ArticlePubMed Google Scholar
Papastergiou SG, Koukoulias NE, Ziogas E, Dimitriadis T, Voulgaropoulos H (2009) Broken bioabsorbable femoral cross-pin as a cause of a chondral lesion after anterior cruciate ligament reconstruction. BMJ case reports. https://doi.org/10.1136/bcr.09.2008.0883
Shen HC, Chang JH, Lee CH, Shen PH, Yeh TT, Wu CC, Kuo CL (2010) Biomechanical comparison of cross-pin and Endobutton-CL femoral fixation of a flexor tendon graft for anterior cruciate ligament reconstruction–a porcine femur-graft-tibia complex study. J Surg Res 161:282–287. https://doi.org/10.1016/j.jss.2009.01.015 ArticlePubMed Google Scholar
Rodeo SA, Kawamura S, Kim HJ, Dynybil C, Ying L (2006) Tendon healing in a bone tunnel differs at the tunnel entrance versus the tunnel exit: an effect of graft-tunnel motion?. Am J Sports Med 34:1790–1800. https://doi.org/10.1177/0363546506290059 ArticlePubMed Google Scholar
Hung C-C, Chen W-C, Yang C-T, Cheng C-K, Chen C-H, Lai Y-S (2014) Interference screw versus Endoscrew fixation for anterior cruciate ligament reconstruction: a biomechanical comparative study in sawbones and porcine knees. J Orthopaedic Transl 2:82–90. https://doi.org/10.1016/j.jot.2014.02.001 Article Google Scholar
Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I. Femoral site. Am J Sports Med 31:174–181. https://doi.org/10.1177/03635465030310020401 ArticlePubMed Google Scholar
Espejo-Baena A, Ezquerro F, Blanca APDI, Serrano-Fernandez J, Nadal F, Montañez-Heredia E (2006) Comparison of initial mechanical properties of 4 hamstring graft femoral fixation systems using nonpermanent hardware for anterior cruciate ligament reconstruction: an in vitro animal study. Arthroscopy 22:433–440. https://doi.org/10.1016/j.arthro.2005.09.021 ArticlePubMed Google Scholar
Ezechieli M, Meyer H, Lucas A, Helmecke P, Becher C, Calliess T, Windhagen H, Ettinger M (2016) Biomechanical properties of a novel biodegradable magnesium-based interference screw. Orthopaedic Reviews (Pavia) 8:6445. https://doi.org/10.4081/or.2016.6445 Article Google Scholar
Yan L, Lim JL, Lee JW, Tia CSH, O’Neill GK, Chong DYR (2020) Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation. Med Biol Eng Compu. https://doi.org/10.1007/s11517-019-02104-9 Article Google Scholar
Ma CB, Francis K, Towers J, Irrgang J, Fu FH, Harner CH (2004) Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and Endobutton-post fixation. Arthroscopy 20:122–128. https://doi.org/10.1016/j.arthro.2003.11.007 ArticlePubMed Google Scholar
Zainal Abidin NA, Abdul Wahab A, Ramlee MH, Abdul Kadir M A mini review on graft fixation devices for anterior cruciate ligament reconstruction - techniques, materials and complications. In: 2018 2nd International Conference on BioSignal Analysis, Processing and Systems (ICBAPS), Kuching, Sarawak, 2018. IEEE, pp 93–98. https://doi.org/10.1109/ICBAPS.2018.8527418
Persson A, Gifstad T, Lind M, Engebretsen L, Fjeldsgaard K, Drogset JO, Forssblad M, Espehaug B, Kjellsen AB, Fevang JM (2018) Graft fixation influences revision risk after ACL reconstruction with hamstring tendon autografts. Acta Orthop 89:204–210. https://doi.org/10.1080/17453674.2017.1406243 ArticlePubMed Google Scholar
Zeng C, Lei G, Gao S, Luo W (2018) Methods and devices for graft fixation in anterior cruciate ligament reconstruction. Cochrane Database Syst Rev 2018:CD010730. https://doi.org/10.1002/14651858.CD010730.pub2
Mahnik A, Mahnik S, Dimnjakovic D, Curic S, Smoljanovic T, Bojanic I (2013) Current practice variations in the management of anterior cruciate ligament injuries in Croatia. World J orthopedics 4:309–315. https://doi.org/10.5312/wjo.v4.i4.309 Article Google Scholar
Ebert JR, Annear PT (2019) ACL reconstruction using autologous hamstrings augmented with the ligament augmentation and reconstruction system provides good clinical scores, high levels of satisfaction and return to sport, and a low retear rate at 2 years. Orthop J Sports Med 7:2325967119879079. https://doi.org/10.1177/2325967119879079 ArticlePubMedPubMed Central Google Scholar
Mirzatolooei F (2012) Comparison of short term clinical outcomes between transtibial and transportal TransFix(R) femoral fixation in hamstring ACL reconstruction. Acta Orthop Traumatol Turc 46:361–366. https://doi.org/10.3944/aott.2012.2679 ArticlePubMed Google Scholar
Aga C, Rasmussen M, Smith S, Jansson K, LaPrade R, Engebretsen L, Wijdicks C (2013) Biomechanical comparison of 8 soft tissue devices for tibial fixation of anterior cruciate ligament reconstruction grafts. Arthroscopy 29:e126. https://doi.org/10.1016/j.arthro.2013.07.156 Article Google Scholar
Monaco E, Fabbri M, Lanzetti RM, Del Duca A, Labianca L, Ferretti A (2017) Biomechanical comparison of four coupled fixation systems for ACL reconstruction with bone socket or full-tunnel on the tibial side. Knee 24:705–710. https://doi.org/10.1016/j.knee.2017.05.003 ArticlePubMed Google Scholar
Schumacher TC, Tushtev K, Wagner U, Becker C, großeHolthaus M, Hein SB, Haack J, Heiss C, Engelhardt M, El Khassawna T, Rezwan K (2017) A novel, hydroxyapatite-based screw-like device for anterior cruciate ligament (ACL) reconstructions. Knee 24:933–939. https://doi.org/10.1016/j.knee.2017.07.005 ArticlePubMed Google Scholar
Shen H-C, Chang J-H, Lee C-H, Shen P-H, Yeh T-T, Wu C-C, Kuo C-L (2010) Biomechanical comparison of cross-pin and Endobutton-CL femoral fixation of a flexor tendon graft for anterior cruciate ligament reconstruction—a porcine femur-graft-tibia complex study. J Surg Res 161:282–287. https://doi.org/10.1016/j.jss.2009.01.015 ArticlePubMed Google Scholar
Zantop T, Herbort M, Raschke MJ, Fu FH, Petersen W (2007) The role of the anteromedial and posterolateral bundles of the anterior cruciate ligament in anterior tibial translation and internal rotation. Am J Sports Med 35:223–227. https://doi.org/10.1177/0363546506294571 ArticlePubMed Google Scholar
Wan C, Hao Z, Li Z, Lin J (2017) Finite element simulations of different hamstring tendon graft lengths and related fixations in anterior cruciate ligament reconstruction. Medical & biological engineering & computing 55. https://doi.org/10.1007/s11517-017-1637-7
Robert W, Westermann BRW, Elkins JM (2013) Effect of ACL reconstruction graft size on simulated Lachman testing: a finite element analysis. Iowa Orthop J 33:70–77 Google Scholar
Wan C, Hao Z, Wen S (2011) The finite element analysis of three grafts in the anterior cruciate ligament reconstruction. In: 2011 4th International Conference on Biomedical Engineering and Informatics (BMEI), 15–17 Oct. 2011 2011. pp 1338–1342. https://doi.org/10.1109/BMEI.2011.6098519
Ramlee MH, Sulong MA, Garcia-Nieto E, Penaranda DA, Felip AR, Kadir MRA (2018) Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study. Med Biol Eng Comput 56:1925–1938. https://doi.org/10.1007/s11517-018-1830-3 ArticlePubMed Google Scholar
Wolf EM, Whelan J (2017) Bio-Transfix ACL reconstruction. Surgical Technique. Arthrex Inc., United State Google Scholar
Synthes D (2015) Milagro advance interference screw. Anteromedial ACL Reconstruction for bone-tendon-bone grafts. Johnson & Johnson Medical Limited, United Kingdom
Nephew S (2012) ENDOBUTTONTM family of fixation devices. Knee Arthroscopy. Smith & Nephew Inc, USA Google Scholar
Pianigiani S, Croce D, D’Aiuto M, Pascale W, Innocenti B (2018) Sensitivity analysis of the material properties of different soft-tissues: implications for a subject-specific knee arthroplasty. Muscles Ligaments Tendons J 7:546–557. https://doi.org/10.11138/mltj/2017.7.4.546
Ramaniraka NA, Saunier P, Siegrist O, Pioletti DP (2007) Biomechanical evaluation of intra-articular and extra-articular procedures in anterior cruciate ligament reconstruction: a finite element analysis. Clin Biomech 22:336–343. https://doi.org/10.1016/j.clinbiomech.2006.10.006 ArticleCAS Google Scholar
Wan C, Hao Z, Li Z, Lin J (2017) Finite element simulations of different hamstring tendon graft lengths and related fixations in anterior cruciate ligament reconstruction. Med Biol Eng Compu 55:2097–2106. https://doi.org/10.1007/s11517-017-1637-7 Article Google Scholar
Shalom H, Sui X, Elianov O, Brumfeld V, Rosentsveig R, Pinkas I, Feldman Y, Kampf N, Wagner HD, Lachman N, Tenne R (2019) Nanocomposite of poly(l-lactic acid) with inorganic nanotubes of WS2. Lubricants 7. https://doi.org/10.3390/lubricants7030028
Fangueiro R, Pereira CG, De AraÚJo M (2008) 18 - Applications of polyesters and polyamides in civil engineering. In: Deopura BL, Alagirusamy R, Joshi M, Gupta B (eds) Polyesters and polyamides. Woodhead Publishing, pp 542–592. https://doi.org/10.1533/9781845694609.3.542
Germain F, Rohan PY, Rochcongar G, Rouch P, Thoreux P, Pillet H, Skalli W Role of ligaments in the knee joint kinematic behavior: development and validation of a finite element model. In: Joldes GR, Doyle B, Wittek A, Nielsen PMF, Miller K (eds) Computational biomechanics for medicine, 2016// 2016. Springer International Publishing, pp 15–26. https://doi.org/10.1007/978-3-319-28329-6_2
Duraisamy S, Yamako G, Chosa E, Subburaj K (2019) Biomechanical evaluation of isotropic and shell-core composite meniscal implants for total meniscus replacement: a nonlinear finite element study. IEEE Access 7:140084–140101. https://doi.org/10.1109/ACCESS.2019.2943689 Article Google Scholar
van der Esch M, Steultjens M, Harlaar J, Wolterbeek N, Knol DL, Dekker J (2008) Knee varus–valgus motion during gait – a measure of joint stability in patients with osteoarthritis?. Osteoarthritis Cartilage 16:522–525. https://doi.org/10.1016/j.joca.2007.08.008 ArticlePubMed Google Scholar
Aragón-Sánchez J, Quintana-Marrero Y, Aragón-Hernández C, Hernández-Herero MJ (2017) ImageJ: a free, easy, and reliable method to measure leg ulcers using digital pictures. Int J Low Extrem Wounds 16:269–273. https://doi.org/10.1177/1534734617744951 ArticlePubMed Google Scholar
Noh J, Lee J (2017) One-year serial follow-up magnetic resonance imaging study of RigidFix for femoral fixation in anterior cruciate ligament reconstruction. Knee Surgery & Related Research 29:209–215. https://doi.org/10.5792/ksrr.16.073 Article Google Scholar
Fogel H, Golz A, Burleson A, Muriuki M, Havey R, Carandang G, Patwardhan A, Tonino P (2019) A biomechanical analysis of tibial fixation methods in hamstring-graft anterior cruciate ligament reconstruction. Iowa Orthop J 39:141–147 PubMedPubMed CentralCAS Google Scholar
Kim J-T, Jung C-H, Shen QH, Cha Y-H, Park CH, Yoo J-I, Song HK, Jeon Y, Won Y-Y (2019) Mechanical effect of different implant caput-collum-diaphyseal angles on the fracture surface after fixation of an unstable intertrochanteric fracture: a finite element analysis. Asian J Surg 42:947–956. https://doi.org/10.1016/j.asjsur.2019.01.008 ArticlePubMed Google Scholar
Longzhen Wang JT, Pengfei Dong, David L. Wilson, Hiram G. Bezerra, Linxia Gu Mechanical performance of PLLA Stent. In: 2018 Design of Medical Devices Conference, Minneapolis, MN, USA, 2018. p 7. https://doi.org/10.1115/DMD2018-6957
Gorsse SMD (2003) Mechanical properties of Ti–6Al–4V/TiB composites with randomly oriented and aligned TiB reinforcement. Acta Mater 51:2427–2442 ArticleCAS Google Scholar
A. EW. A. Hadi MRAK, M. N. Harun, A. Syahrom The influence of PEG designs on glenoid component: a finite element study. In: Malaysian INternational Tribology Conference, 2015. Malaysian Tribology Society, pp 52–53
Brandon P, Lucke-Wold PCB, Jacob G (2017) Re-fracture of distal radius and hardware repair in the setting of trauma. Medical Student Research Journal 5:2–7 Google Scholar
Garg AK (2009) Implant dentistry - E-Book. Elsevier Health Sciences,
Askeland DR, Fulay PP, Wright WJ (2011) The science and engineering of materials, SI edition. Cengage Learning,
Milano G, Mulas PD, Ziranu F, Piras S, Manunta A, Fabbriciani C (2006) Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: a biomechanical analysis. Arthroscopy: The Journal of Arthroscopic & Related Surgery 22:660–668. https://doi.org/10.1016/j.arthro.2006.04.082 Article Google Scholar
Frost HM (2001) The anatomical record: an official publication of the American Association of Anatomists. From Wolff’s law to the Utah paradigm: insights about bone physiology and its clinical applications, vol 4. Wiley Online Library. https://doi.org/10.1002/ar.1049.
Zhang X, Gong HE (2015) Simulation on tissue differentiations for different architecture designs in bone tissue engineering scaffold based on cellular structure model. Journal of Mechanics in Medicine and Biology 15:1550028. https://doi.org/10.1142/S0219519415500281 Article Google Scholar
Finn E, Donaldson PP, Hamish A, Simpson RW (2012) Bone properties affect loosening of half-pin external fixators at the pin-bone interface. Injury, Int J Care Injured 43:1764–1770 Article Google Scholar
Rodríguez C, Maestro A, García TE, Montes S (2011) Static load biomechanical behaviour of different femoral fixation systems for anterior cruciate ligament reconstruction. Revista Española de Cirugía Ortopédica y Traumatología (English Edition) 55:428–436. https://doi.org/10.1016/j.recote.2011.07.001 Article Google Scholar
Chen C-H, Hung C, Hsu Y-C, Chen C-S, Chiang C-C (2017) Biomechanical evaluation of reconstruction plates with locking, nonlocking, and hybrid screws configurations in calcaneal fracture: a finite element model study. Med Biol Eng Compu 55:1799–1807. https://doi.org/10.1007/s11517-017-1623-0 Article Google Scholar
Zainal Abidin NA, Abdul Kadir MR, Ramlee MH (2020) Biomechanical effects of different lengths of cross-pins in anterior cruciate ligament reconstruction: a finite element analysis. J Mechanics Medicine Biol 20:2050047. https://doi.org/10.1142/S0219519420500475