Free Testosterone Measurement by the Analog Displacement Direct Assay: Old Concerns and New Evidence (original) (raw)

Journal Article

,

Address correspondence to this author at:, Chief, Division of Endocrinology, Harbor-UCLA Medical Center, Los Angeles Biomedical Research Institute, 1000 West Carson Street Box 446, Torrance, CA 90509-2910, Fax (310) 533-0627, E-mail swerdloff@labiomed.org

Search for other works by this author on:

Division of Endocrinology

, Department of Medicine, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, Torrance CA

Search for other works by this author on:

Cite

Ronald S Swerdloff, Christina Wang, Free Testosterone Measurement by the Analog Displacement Direct Assay: Old Concerns and New Evidence, Clinical Chemistry, Volume 54, Issue 3, 1 March 2008, Pages 458–460, https://doi.org/10.1373/clinchem.2007.101303
Close

Navbar Search Filter Mobile Enter search term Search

Fritz and coworkers (1) have provided data arguing against the validity of a popular analog-based direct assay for free testosterone (T). Their rigorous dissection of characteristics of the assay and use of carefully defined solutions demonstrates that the assay correlates generally with total T but does not measure dialyzable T; this observation is consistent with prior reservations about this class of assay by reported by the Endocrine Society (2)(3) and of other investigators (4)(5)(6).

why worry about free t?

Testosterone circulates in the blood of men and women in several forms. It is bound tightly to sex-hormone binding globulin (SHBG), loosely to albumin, and unbound to proteins (free) (7). In most, but not all, clinical conditions, a measurement of total T is adequate for the evaluation of a patient. It is widely believed that the SHBG-bound T is not readily available to most tissues, whereas albumin-bound and free T are bioavailable. Because SHBG concentrations can be influenced by many factors (e.g., decreased by obesity, testosterone treatment, and hyperandrogenic female conditions such as polycystic ovary syndrome and increased by aging, pregnancy, and estrogen therapy), there are clinical situations in which measured concentrations of total T may not reflect the bioavailable concentrations or the clinical status of the patient (3)(7)(8). In these circumstances a supplemental test assessing bioavailable or free T will be helpful in clinical decision-making.

how is free t or bioavailable t determined?

Free T has been estimated for some time by dialyzing serum across a semipermeable membrane under selected conditions. The T in the serum that crosses the membrane is believed to be unbound or free. Because free T accounts for only about 2%–3% of the total T in men and even less in women, direct measurement of T in the dialysate has been reported (9) but is technically difficult with most assays. To overcome this limitation of T assay sensitivity, most dialysis assays for free T use tracer amounts of radiolabeled T added to the serum, and the isotope is measured in the dialysate. The percentage of dialyzable tracer is determined and multiplied by the total T to calculate the free T (7). This method, although sensitive and reproducible, is cumbersome and not easily adaptable to automated methods. An alternative method is to estimate free T by measuring total T and SHBG and calculate a free T with an algorithm based on the law of mass action or by empirical equations (7)(10). This calculated free T gives excellent correlations with the free T measured with the dialysis method (5). A third approach is to measure bioavailable T as a free T surrogate by precipitating SHBG with ammonium sulfate and measuring the albumin-bound and free T in the supernatant (11). Although the latter approach is technically simple, care must be taken to assure the correct concentration of ammonium sulfate for complete precipitation of the SHBG-T complex. The fourth method is that studied by Fritz et al. (1). Although this method is used widely, the analog-based assay described in their report is an automated black-box package with a proprietary radioactive buffer provided by the manufacturer; this class of assay has been criticized as having poor accuracy, sensitivity, and between-assay comparability and being influenced by the dilution of serum (2)(3)(4)(5)(6). It is of note that the reference interval for free T by analog-based assay is much lower (concentrations about one-fifth as high) than that for the equilibrium dialysis assay (2). This calibration difference between assays is a major problem.

what did fritz and coworkers find in their studies?

These investigators dissected one analog-based free T assay by measuring total T and free T by analog methods both in the retentate and dialysate fractions of serum after equilibrium dialysis. Free T was also measured using the standard equilibrium assay method on the dialysate. The analog free T assay correlated with total T in the retentate but neither the total T assay nor analog free T assay measured any T in the dialysate, although the concentrations were in the reference range by equilibrium dialysis. Fritz et al. then used the same method on the sample while covarying concentrations of SHBG, protein-bound T, and total T through dilution of serum. The results showed that the analog-based assay tracked total T more closely than free T by the dialysis method. In the third experiment they diluted the serum while adding increased amounts of protein-free T to keep the total T in the serum constant. The results showed that the total T and free T by the analog method remained constant while the free T by the dialysis method increased as expected. Thus their studies showed that free T measurement with the analog-based free T assay has no advantage over total T measurements and does not measure unbound T. Fritz et al. conclude that the assay is not properly calibrated, lacks specificity, and does not measure free T.

what does the analog assay measure?

It is not entirely clear what constituent(s) are being measured, but free T measured by the analog-based assay correlates with total T. Fritz et al. (1) speculated that the assay nonspecificity may be due to protein-T complexes binding to the T antibody, leading to a 3-way competition between free testosterone, testosterone complexes, and testosterone conjugates (analogs) for binding to the same antibody. This explanation should be testable using liquid chromatography–tandem mass spectrometry (12).

do the findings of fritz and coworkers apply to other branded analog-based free t assays?

The authors are cautious, but given the information provided, other free T analog assays probably show similar characteristics of tracking total T and not free T; thus providing no advantage over total T measurements.

why are these analog-based free t assays so widely used?

The wide use of these assays is based in part on their ease of performance, automated nature, and lower cost than free T measurement by dialysis. The popularity of these assays may also be a result of lack of specific knowledge of physicians regarding the limitations of the assay methodology. Because the free T by analog method tracks total T, and because most men with total T concentrations that are very low do not require a free T to confirm the diagnosis of male hypogonadism, the results seem to fit the clinical impression. Because the experts in the field recommend free T measurements in equivocal cases of hypogonadism, the practicing physician often orders the correct test but the wrong assay.

should the analog-based free t assay be used in clinical practice?

Because the analog-based assay does not measure free T, it makes no sense to label it as such. Because it tracks total T but has not been shown to add to the values of total T results, we do not recommend its use.

are the current methods of total t assays adequate?

It is important to note that free T measured by equilibrium dialysis requires a sensitive, specific, precise, and accurate assay for total T. Recent studies have shown that the current methods of measurement of total T lacked the required sensitivity for samples with very low concentrations, as occur in severely testosterone deficient men, normal or T-deficient women, and children; this sensitivity limitation can be corrected by newer methods based on mass spectrometry (12)(13)(14). Furthermore, the free T analog–based assay may be only one of a number of widely used but poorly assessed and quality controlled hormone assays (2)(15). The CDC has provided quality control services for several analytes, including recent efforts to do so for total T by liquid chromatography–tandem mass spectrometry. It is time that physicians, investigators, clinical chemists, pathologists, and editors of medical journals insist on better surveillance of assays used in research and patient care.

References

1

Fritz KS, McKean AJS, Nelson JC, Wilcox RB. Analog-based free testosterone test results linked to total testosterone concentrations, not free testosterone concentrations.

Clin Chem

2008

;

54

:

512

-516.

2

Rosner W, Auchus RJ, Azziz R, Sluss PM, Raff H. Utility, limitations, and pitfalls in measuring testosterone: an Endocrine Society Position Statement.

J Clin Endocrinol Metab

2007

;

92

:

405

-413.

3

Bhasin S, Cunningham GR, Hayes FJ, Matsumoto AM, Snyder PJ, Swerdloff RS, Montori VM. Testosterone therapy in adult men with androgen deficiency syndromes: an Endocrine Society Clinical Practice Guideline.

J Clin Endocrinol Metab

2006

;

91

:

1995

-2010.

4

Van UK, Stockl D, Kaufman JM, Fiers T, De LA, Thienpont LM. Validation of 5 routine assays for serum free testosterone with a candidate reference measurement procedure based on ultrafiltration and isotope dilution-gas chromatography-mass spectrometry.

Clin Biochem

2005

;

38

:

253

-261.

5

Miller KK, Rosner W, Lee H, Hier J, Sesmilo G, Schoenfeld D, et al. Measurement of free testosterone in normal women and women with androgen deficiency: comparison of methods.

J Clin Endocrinol Metab

2004

;

89

:

525

-533.

6

Winters SJ, Kelley DE, Goodpaster B. The analog free testosterone assay: are the results in men clinically useful?.

Clin Chem

1998

;

44

:

2178

-2182.

7

Vermeulen A, Verdonck L, Kaufman JM. A critical evaluation of simple methods for the estimation of free testosterone in serum.

J Clin Endocrinol Metab

1999

;

84

:

3666

-3672.

8

Chang WY, Knochenhauer ES, Bartolucci AA, Azziz R. Phenotypic spectrum of polycystic ovary syndrome: clinical and biochemical characterization of the three major clinical subgroups.

Fertil Steril

2005

;

83

:

1717

-1723.

9

Sinha-Hikim I, Arver S, Beall G, Shen R, Guerrero M, Sattler F, et al. The use of a sensitive equilibrium dialysis method for the measurement of free testosterone levels in healthy, cycling women and in human immunodeficiency virus-infected women.

J Clin Endocrinol Metab

1998

;

83

:

1312

-1318.

10

Sodergard R, Backstrom T, Shanbhag V, Carstensen H. Calculation of free and bound fractions of testosterone and estradiol-17 beta to human plasma proteins at body temperature.

J Steroid Biochem

1982

;

16

:

801

-810.

11

Morley JE, Patrick P, Perry HM. III. Evaluation of assays available to measure free testosterone.

Metabolism

2002

;

51

:

554

-559.

12

Wang C, Catlin DH, Demers LM, Starcevic B, Swerdloff RS. Measurement of total serum testosterone in adult men: comparison of current laboratory methods versus liquid chromatography-tandem mass spectrometry.

J Clin Endocrinol Metab

2004

;

89

:

534

-543.

13

Sikaris K, McLachlan RI, Kazlauskas R, de KD, Holden CA, Handelsman DJ. Reproductive hormone reference intervals for healthy fertile young men: evaluation of automated platform assays.

J Clin Endocrinol Metab

2005

;

90

:

5928

-5936.

14

Taieb J, Mathian B, Millot F, Patricot MC, Mathieu E, Queyrel N, et al. Testosterone measured by 10 immunoassays and by isotope-dilution gas chromatography-mass spectrometry in sera from 116 men, women, and children.

Clin Chem

2003

;

49

:

1381

-1395.

15

Matsumoto AM, Bremner WJ. Serum testosterone assays: accuracy matters.

J Clin Endocrinol Metab

2004

;

89

:

520

-524.

© 2008 The American Association for Clinical Chemistry

Citations

Views

Altmetric

Metrics

Total Views 403

277 Pageviews

126 PDF Downloads

Since 1/1/2020

Month: Total Views:
January 2020 3
February 2020 5
March 2020 2
April 2020 4
May 2020 2
June 2020 1
July 2020 5
August 2020 11
September 2020 22
October 2020 2
November 2020 7
December 2020 8
January 2021 3
February 2021 9
March 2021 3
April 2021 6
May 2021 12
June 2021 7
July 2021 4
September 2021 2
October 2021 2
November 2021 12
December 2021 7
January 2022 9
February 2022 6
March 2022 5
April 2022 7
May 2022 7
June 2022 8
July 2022 11
August 2022 17
September 2022 18
October 2022 7
November 2022 6
December 2022 8
January 2023 13
February 2023 10
March 2023 8
April 2023 7
May 2023 8
June 2023 2
July 2023 4
August 2023 7
September 2023 11
October 2023 6
November 2023 3
December 2023 9
January 2024 10
February 2024 9
March 2024 8
April 2024 5
May 2024 7
June 2024 8
July 2024 1
August 2024 8
September 2024 7
October 2024 4

Citations

43 Web of Science

×

Email alerts

Citing articles via

More from Oxford Academic